Six (6) New Residential Compounds at East-West Pump Stations 1, 3, 5, 6, 10 & PRS-1

EPC/PMC Weekly Safety Walk-through Report


Date: 14/05/2023 Time: 10:00 AM Location: PS#01 Site
Sn Findings & Recommendations Corrective Actions Responsible Due date Status/Remarks
missing guardrails on the scaffolding in type 3 Guardrails (toprail & midrails) and toeboards was
building/ Guardrail system consisting of toprails, installed.
midrails and support uprights shall be installed.

1 CMD 18/05/2023 

Missing handrail & platforms on the temporary proper access was be provided with handrails.
access provided to the type 3 building./ proper
access shall be provided with complete guardrails.

CMD 18/05/2023
2 
Six (6) New Residential Compounds at East-West Pump Stations 1, 3, 5, 6, 10 & PRS-1

missing guardrails on the scaffolding in type 3 Guardrails (toprail & midrails) and toeboards was
building/ Guardrail system consisting of toprails, installed.
midrails and support uprights shall be installed.

3 CMD 18/05/2023 

missing guardrails on the scaffolding in type 3 Guardrails (toprail & midrails) and toeboards was
building/ Guardrail system consisting of toprails, installed.
midrails and support uprights shall be installed.

4 CMD 18/05/2023 
Six (6) New Residential Compounds at East-West Pump Stations 1, 3, 5, 6, 10 & PRS-1

scaffold platform in type 3 building have gap Housekeeping was done and toeboards was
between the other platform and required to installed.
install toeboard. unnecessary materials shall be
removed.

5 CMD 18/05/2023 

electrical cords found obstructing the access of the room in Electrical cables was removed and housekeeping
type 3 1st floor./electrical cords shall not create trip hazards was done.
on walking and working surfaces. Cables shall be supported
at least 2.4 meters above walkways by non-conductive
materials.

6 CMD 18/05/2023 
Six (6) New Residential Compounds at East-West Pump Stations 1, 3, 5, 6, 10 & PRS-1
unprotected reinforcing steel found at the excavation area Rebar caps was provided.
beside community center./All protruding reinforcing steel
onto which employees could fall shall be guarded to
eliminate the hazard of impalement.

7
CMD 18/05/2023 

Poor housekeeping has been observed in several Good housekeeping was maintained at site.
areas at site./Good housekeeping shall be proper
maintained at site.

8 CMD 18/05/2023 
Six (6) New Residential Compounds at East-West Pump Stations 1, 3, 5, 6, 10 & PRS-1