PIA 777-240 ER/LR/-340ER MINIMUM EQUIPMENT LIST 30-1 (PIA Rev 00)

OPERATIONS MANUAL 30: ICE AND RAIN PROTECTION JULY, 2012

STANDARD EQUIPMENT MINIMUM FOR DISPATCH

ITEM SUPPLEMENTAL PROCEDURES


-11-01 WING ANTI-ICE C 2 0 (M) May be inoperative provided:
SYSTEMS a) Associated valve is locked closed,
b) Wing anti-ice control switch remains OFF,
and
c) Airplane is not operated in known or
forecast icing conditions.

-11-02 WING ANTI-ICE C 1 0 (M) May be inoperative provided:


CONTROL (CARD AND a) Both wing anti-ice valves are locked
SWITCH) closed,
b) Wing anti-ice control switch remains OFF,
and
c) Airplane is not operated in known or
forecast icing conditions.
-11-03 WING ANTI-ICE C 2 0
INDICATIONS (WAI)

-21-01 ENGINE ANTI-ICE C 2 1 (M) One may be inoperative provided:


SYSTEMS a) Valve is locked closed,
b) Associated engine anti-ice control switch
remains OFF,
c) Airplane is not operated in known or
forecast icing conditions, and
d) Flight remains within 120 minutes of
landing at a suitable airport.

-21-01-01 PW & RR NOT APPLICABLE

-21-01-02 GE

-21-01-02A C 2 1 (M)(O) For operations at ambient temperature 38


degrees C or below, one may be inoperative
provided:
a) Valve is deactivated open using
deactivation kit,
b) Engine fan case overheat detection system
operates normally,
c) Turbine case cooling air flow systems
operate normally,
d) Appropriate performance adjustments are
applied, (Refer DDG) and
e) Except for GE90-100 series, EECs must
be operated in the normal mode. (-200ER)

-21-01-02B C 2 1 (M)(O) For operations at ambient temperature 38


degrees C or below, one may be inoperative
provided:
a) Valve is electrically disconnected and
verified open,
b) Engine fan case overheat detection system
operates normally,
(Continued…)