COMPLIANCE SHEET
N CONSULTANT COMMENTS REPLY
MECHANICAL COMMENTS
6 Specify the life time of the UV lamp. 2 years Lifetime. Please refer to pp. 29
7 Declare that the UV system proposal is not harm for human being. Please refer to pp. 28
page 3
DATE : 06-02-2023
REF: MP021/21/MS/004
MATERIAL SUBMITTAL
PROJECT : G+1 CENTRO MALL
CONSULTANT : DSG
SUB - CONTRACTOR :
page 4
DATE : 06-02-2023
REF: MP021/21/MS/004
MATERIAL SUBMITTAL
MATERIALASUBMITTAL
PROJECT : G+1 CENTRO MALL ATTACHMENTS
CATALOGUE
LOCATION : RAWDAT AL HAMMAMA
CALCULATION
CONSULTANT : DSG
SAMPLE
MAIN CONTRACTOR : KHM (KHALED & HAMAD SONS OF M. AL MANA)
MATERIAL
UV System 130 m3 Capacity, Model: Quantum
DESCRIPTION
QUANTITY 2 Nos.
REQUIRED
COUNTRY OF ORIGIN UK
MANUFACTURER Elecro
SUPPLIER
SUBMITTED BY
Mr. Moataz Mekawi Technical Manager 06-02-2023
APPROVED AS
STATUS APPROVED
NOTED
REVISE & RESUBMIT ADDITIONAL INFORMATION REQUIRED
COMMENT:
page 5
IN ENGL
E
Unit 11, Gunnels Wood Park, Stevenage,
AN
• MA
Hertfordshire SG1 2BH
D•
ND
MA
Sales@elecro.co.uk | +44 (0) 1438 749474 E
A
IN E N GL
D
www.elecro.co.uk
QUANTUM
Quantum uses new ceramic Nano Crystal
technology, a prime focus of the science
world today; possessing the power to
sterilise sewage into drinking water without
the use of chemicals.
FEATURES
• Photocatalytic Ti02/Mo oxidiser and clarifier • Optional smart peristaltic dosing system for chlorine
• Combined photocatalytic, hydroxyl radical and hydrogen peroxide
and UV technology • Powerful sterilisation and eliminates the smell
• Eliminates contaminants, leaving water looking of chlorine
fresh and clean • Average lamp life expectancy: 2 years
• Reduces the need for chemicals in the pool • Equipped with intelligent lamp life indicator
• Keeps your family safe from dangerous • Salt and sea water compatible
microorganisms such as cryptosporidium,
adenoviruses and naegleria fowleri
TECHNICAL DRAWINGS
'26,1*81,7
&+(0,&$/
322/
896<67(0
1215(7851
9$/9(
),/7(5
3803
(/(&75,&+($7(5
PRESSURE DROP
PRESSURE DROP PRIMARY CIRCUIT
PRESSURE 0.9
(BAR) 0.8
0.7
0.6
0.5
0.4
0.3 Q-130 & QP-130
0.2
0.1
0 Q-65 & QP-65
0 5 10 15 20 25 30 35
MAX. FLOW RATE Single Tube: 14,000 litres per hour; 14 m³/h
Double Tube: 28,000 litres per hour; 28 m³/h
FREQUENCY 50/60 Hz
WATER CONNECTIONS 2" / 63mm stepped ABS unions + reducers 1½" / 50mm
OXIDISATION PROCESSES Quantum photocatalytic oxidiser (PCO) & hydroxyl radicals (HO)
MODELS
55 WATTS 65 Q-65-UK Q-65-EU Q-65-USA Analogue lamp life indicator 7.1 9.7 0.11
& reset switch
110 WATTS 130 Q-130-UK Q-130-EU Q-130-USA Analogue lamp life indicator 11.6 15.1 0.15
& reset switch
55 WATTS 65 QP-65-UK QP-65-EU QP-65-USA Digital lamp life countdown 7.4 10.1 0.11
with intelligent dosing pump
110 WATTS 130 QP-130-UK QP-130-EU QP-130-USA Digital lamp life countdown 11.9 15.5 0.15
with intelligent dosing pump
3.21
Photo-catalyst Attacking By product
Titanium Dioxide Harmful Pollutants Harmless H2O
and Co2
•OH
•OH
•OH H 2O
•OH
•OH VOCS H 2O
Hydrogen Peroxide
BACTERIA
Hypochlorous Acid
PHOTOCATALYTIC
Hydroxyl Radicals
VIRUSES
Monochloramine
•OH H 2O
Singlet Oxygen
Permanganate
Hypobromous
•OH CO2
OXIDISATION
•OH •OH
•OH CO2 1.07
•OH
Bromide
Chlorine
Fluorine
Oxygen
Ozone
Acid
Oxidant
page 7
QUANTUM PRO
Photocatalytic Pool Sanitiser
Installation & Operating Manual
QP-65 QP-130
page 8
CONTENTS
5. MAINTENANCE ..............................................................................................................................14
5.1 Essential parts to carry out annual maintenance including our reference codes ........................... 15
page 9
Introduction
Thank you for purchasing the Quantum pool sanitising system, the latest sanitisation technology,
manufactured to the highest standards in England.
To ensure years of trouble-free service, please read and follow these instructions for proper installation,
maintenance and use. Incorrect installation will affect your warranty.
WARNINGS:
• Ultraviolet light is damaging to your eyes or skin! Never handle or look directly at an
illuminated UV lamp(s).
• This unit must be earthed.
• Power must be supplied through a Residual Current Device (RCD) with a rated residual
operating current not exceeding 30mA
• Do not run this unit dry
• Do not cover this unit
• The unit must not be submerged in water
• Carefully examine the unit after installation. It should not be powered on if there is water
on any parts not intended to be wet
• If the unit shows any sign of water leakage immediately disconnect power supply
• If the quartz sleeve is cracked, replace it immediately
• To avoid injuries young children should never be allowed near UV steriliser
• Failure to disconnect the power from the UV steriliser and pump before servicing or
maintenance could result in personal injury or property damage.
2. PRODUCT OVERVIEW
The Quantum is available in 55W single tube and 110W double tube formats, supplied complete with flow
switch and either an analogue lamp life indicator and reset switch, or digital lamp life countdown with
intelligent dosing pump.
Fig. 1 Fig. 2
page 10
Dimensions:
The Quantum should be either installed horizontally or vertically allowing enough space for the pipe
connections, wiring and maintenance of lamps/quartz sleeve. It should be firmly secured, using the fixing
kit provided, to a solid wall.
NOTE: When mounting the UV, it is essential to leave a clearance space of at least 1 metre
from one side of the unit to allow access to replace the lamp(s) and/or quartz
sleeve(s) when required. Both the lamps and the quartz sleeve can be replaced
from either end of the unit; if installing vertically the 1m clearance space must be
above or below the unit, if installing horizontally the 1m clearance space must be to
the left or right of the unit.
WARNING: The Quantum must be installed within a dry, permanent weather-proof area. In
any case where water or moisture enters the enclosure the warranty will be void.
Caution: If the Quantum is unused during the winter months, it must be drained to prevent frost
damage. Water must not be allowed to freeze inside the unit as this will cause severe
damage.
page 11
.
Fig.3
The Quantum should be placed downstream (after) of any pumps, filters and heating devices but upstream
(before) of any chemical dosing or similar water treatment (see Figs. 4 and 5).
Fig. 4
page 12
Fig. 5
The Quantum is factory set to accept input water flow entering on the left and exiting on the right, this can
be reversed by rotating the flow switch 180 degrees (i.e. ½ turn - see Fig. 6).
page 13
Fig. 6
WARNING! The flow switch paddle can be damaged when reversing the flow direction if it is
lifted by more than 5mm from its housing and turned with force. If the flow switch
has been rotated it is important to ensure that it is finally locked in the correct
orientation perpendicular (at right angles) to the flow of water.
page 14
3.4 Connection
The unit is supplied with unions to allow connection to 2" or 63-mm rigid pipe. Reducers are also supplied
to allow connection to 50-mm or 1½" rigid pipe - see Fig 7.
Fig.7
All factory unions are made from an ABS plastic, when gluing connections to an ABS pipe, an ABS cement
must be used or when using a PVC pipe, a Transition cement must be used (See Fig. 7).
There is no need to use mastic or PTFE tape to connect unions to the Quantum, use the O-rings provided
to put in the groove on the end of the Manifold Assembly.
page 15
3.5 Electrical connection
4. OPERATING INSTRUCTIONS
This unit is a plug and play device so as long as the minimum flow rate is achieved the unit will work as
soon as the power is switched on.
WARNING: Failure to meet the water quality limits will void the warranty.
page 16
4.3 Lamp life indicator + intelligent dosing pump (Digital)
STEP ONE
Components required.
STEP TWO
Unscrew securing cap anti-clockwise.
STEP THREE
Thread tube through the securing cap (1)
and component (2), then push the pipe onto
component (3)
page 17
STEP FOUR
Once all components are looped through the tubing
tighten securing cap.
STEP FIVE
Lastly unscrew the retaining gland and insert tube over the connection
point. Tighten the retaining gland Place the Foot Valve Strainer into the
chemical container.
• UV Lamp Life
• Shock Dose
• Dose Chemical
• Set Time
To select a mode, press the / buttons until the desired mode is displayed then press the OK
button to select that mode.
When the unit is powered on the UV lamp is switched on, the UV lamp will switch off under the following
conditions i.e.
• Dosing pump ‘On’ (and for 30 minutes after the dosing pump has completed dosing)
page 18
• No or low water flow (the UV lamp(s) cannot be switched on unless the unit is receiving sufficient
flow) See page 9 for flow requirements.
UV Lamp Life
To set the type of chemical: use the / buttons until “DOSE CHEMICAL” is displayed, press the
O.K. button and then use the / buttons to choose:
A. ‘H2O2’ or
B. ‘CHLORINE’
After selecting ‘H2O2’ in Part 1 the display will now show ‘H2O2 DOSE’ the / buttons select the
correct dosage volume in ml (millilitres) – Refer to Table A for suggested H₂O₂ dosing figures.
Once the correct dosage volume is displayed press the O.K button to confirm, the display will then show
‘H2O2 START’
You now need to enter the time that you would like the dosing to take place.
NOTE:
• The time must be entered in the 24-Hour format and the dosing will take place at
this time every day (24-Hours).
• The time selected must be at a time when the main filtration pump will be running.
page 19
• Once the desired time has been selected press the ‘O.K.’ button and the display will
then show ‘SAVED’.
• If the dosing volume is set to 0.0 (ml) the peristaltic pump will remain off.
• In the event of power loss: the programmed settings (dosing volume and dosing
time) will remain stored. If the power to the controller is switched off for longer than
3-Hours the current time will need to be re-programmed, this is indicated to the
operator by the clock flashing.
35 200
50 320
60 420
80 620
90 700
100 800
130 1040
150 1200
Table A
NOTE:
• The above table is based on dosing Hydrogen Peroxide (H₂O₂) with a 32%
concentration and a water temperature of 28⁰C.
• For a concentration of 12% the above dosing amount should be multiplied by 3 (i.e. the
dose for a 50m³ pool would need to be increased to 960ml/day when the H ₂O₂ strength
is 12%).
• For any other concentration strengths, the dose amount should be adjusted pro-rata as
required. The digital controller will automatically sense the temperature of your water
and adjust the required dose accordingly.
• When dosing with liquid chlorine the daily dosage amount should be halved to enable half the dose
to be delivered in the morning (CL 1 DOSE) and half the dose to be delivered in the afternoon (CL
2 DOSE).
• The controller does not monitor the free chlorine level. The pool free chlorine levels must be
regularly checked, and the dosage volume adjusted if required.
After selecting ‘CHLORINE’ in Part 1 the display will show ‘CL 1 DOSE’ using the / buttons select
the correct dosage volume in ml (millilitres). Once the correct dosage volume is displayed press the O.K
button to confirm, the display will then show ‘CL 1 START’.
You now need to enter the time that you would like the CL 1 dosing to take place. Once the correct time
is selected press the ‘O.K.’ button.
The display will then show ‘CL 2 DOSE’ you now need to repeat the above process to programme the CL
2 DOSE (volume) and CL 2 START (time).
NOTE:
page 20
• The time must be entered in the 24-Hour format and the dosing will take place at this time
every day (24-Hours).
• The time selected must be at a time when the main filtration pump will be running.
• It is recommended to keep the dosage volumes in equal halves, however should you need
to adjust to have a larger proportion during the CL 1 or CL 2 periods then this can be
programmed accordingly, if you only wish to use one of the dosing periods then this is also
possible.
• If the dosing volume for both CL 1 and CL 2 periods is set to 0.0 (ml) the peristaltic pump
will remain off.
Table B
NOTE: In the event of power loss: the programmed settings (dosing volume and dosing time)
will remain stored. If the power to the controller is switched off for longer than 3-Hours
the current time will need to be re-programmed, this is indicated to the operator by
the clock flashing.
• To complete the set up you need to programme the current time: Use the / buttons until
‘SET TIME’ is displayed, press the O.K. Button.
• Use the / buttons as required to select the current time
• NOTE: the time must be entered in the 24-Hour format.
• The display will now revert to showing the UV lamp life remaining and the current time.
Shock Dose
The shock dose feature enables the operator to shock dose the pool immediately with a chosen volume
of the dispensing chemical. This may be necessary following heavy use of the pool or a change of water
conditions.
To activate the Shock Dose feature uses the / buttons to scroll until ‘SHOCK DOSE’ is displayed,
press the ‘O.K’ button.
Using the / buttons select the volume (in ml/millilitres) that you would like to shock dose the pool
with. When the correct value is shown, press the ’OK’ button to confirm. The display will show ‘SAVED’
and the shock dose will begin immediately.
NOTE: The shock dose will only begin if the main filtration pump is operational.
5. MAINTENANCE
To avoid any water leaks and optimum performance annual maintenance of the UV steriliser is
essential. Failure to do so could result in damage to the product and significant drop in efficiency.
5.1 Essential parts to carry out annual maintenance including our reference codes
WARNING: Before performing any maintenance isolate from the main power supply, turn off
circulation pump and drain the unit.
SP-UV-LAMP-EL SP-UV-QS
Fig. 8 Fig. 9
SP-UV-ORS SP-UV-LLL-LF
Fig. 10 Fig. 11
page 22
Unclamping the clip from body
Unscrew all the highlighted fasteners 1. Pull the clip in shown direction to
unlock from body
2. Pull the second side after unlocking
the 1st side
Remove Lamp holder Clip from Hard Unmount the Hard cap from Blue lamp Holder
cap
Carefully remove the blue lamp holder Gently slide the lamp out ensuring that no
shroud and white plastic electrical end pressure is applied to the glass quartz sleeve
caps from the lamp end.
page 23
Unscrew the blue quartz sleeve
locking nut anticlockwise. Both ends Slide the O-ring off the quartz sleeve
must be unscrewed before the quartz
sleeve can be removed
Clean the sleeve and polish with a soft cloth or paper towel.
If you live in a hard water area there may be some limescale on the quartz sleeve. This can be easily
removed by soaking the sleeve in a proprietary kettle descaling solution (follow the manufacturer’s
instructions).
NOTE: Failure to remove the limescale will limit the effectiveness of the UV lamp(s).
Assembly process
• Firstly, slide the clean dry quartz glass sleeve into the unit.
• Locate the ’O’ rings carefully on the ends of the quartz sleeve.
• Make sure the threads are clean, wipe a little silicone grease onto the threads. As these threads
are only serviced periodically, this lubrication will help to prevent them binding together.
• Hand tighten the blue quartz sleeve locking nuts onto the unit. Be sure not to overtighten as this
can damage the quartz sleeve.
• Replace the UV lamp(s) with a new one(s) and reconnect blue lamp holders.
NOTE: To avoid bending the lamp pins during the reassembly, pull the plastic fitting out of the
shroud. Connect it to the lamp and push the shroud back in to place.
page 24
NOTE: Pinch the blue lamp holder shroud as you reassemble the unit to release any
trapped air. Failure to release the trapped air may cause the lamp holder to
disconnect from the lamp end. Turn on the water supply to check for leaks before
reconnecting the electric supply.
Important: The plastic body and blue compression fittings have been manufactured from polymers that
have been specifically stabilised to protect them from the effects of the UVC emitted from
the UV lamps. Despite this UV protection they will be eroded by a combination of the UVC
and water flow. As a matter of course they should be inspected whenever a lamp change
is carried out, to ensure they are not showing excessive wear and tear. Replacement parts
are available.
We recommend that the dosing tube is changed every 6-12 months in order to prevent any wear and tear
and keep performance to an optimum. The following steps will guide you how to replace the dosing tube:
STEP ONE
Unscrew the two screws securing the plastic cover
and remove. Rotate the grey connections caps to
release the tubing.
STEP TWO
Remove the connection point on the left-hand side,
and then carefully manually rotate the cam to allow
remove of the dosing tube.
page 25
STEP THREE
Cut the two black securing ties at either end of the
tube. This will then release the tube, which can be
discarded.
STEP FOUR
Take the replacement tube and re-attach
connection points. Loop securing ties in place in
order to seal to the connection points. Once
securely in place cut the excess tie and dispose of.
STEP FIVE
Place dosing tube into position on the left-hand
side. Carefully rotate the cam clockwise, whilst
feeding the pipe back into place.
STEP SIX
Replace the suction and output tubes on to the
connection caps and rotate to secure tubing back
into place. Replace clear cover and screw into
position.
This symbol on the product or on the packaging indicates that this product should not be treated as
household waste. Instead it should be handed over to the applicable collection point for the recycling of
electrical and electronic equipment.
By ensuring this product is disposed of correctly you will help prevent potential
negative consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product. The
recycling of materials will help to conserve natural resources.
For more information please contact your local Civic Office, household waste
disposal service or the retailer where the product was purchased.
page 26
7. CALCULATING POOL VOLUMES
The following pages will show you how to calculate the volume of the pool.
D1 + D2 = Average Depth
2
If your pool has a sloping bottom, then take the deepest measurement (D2) and the shallowest (D1). If
there are different levels, then you need to do several calculations of area for each depth and add them
up at the end.
Circular
Volume = π (3.142) x Radius2 x Depth (D) OR Average Depth
Ellipses
Volume = π (3.142) x A x B x Depth (D) OR Average Depth
Irregular Shapes
For irregular shapes, calculating the area is less accurate. You will need to draw the pool accurately to
scale on graph paper using one square on the graph paper to represent a metre (or foot) square of pool.
When you have completed, count the squares.
For partial squares, count anything over half as one and ignore any under a half. When you have the area
(A) multiply by depth (D) for the Volume in cubic metres. If you have several depths, break up your area
calculation for each depth.
Useful Conversions
Cubic Metres to Litres = Multiply by 1000
Cubic Feet to Cubic Metres = Multiply by 0.0283168
UK Gallons to Litres = Multiply by 4.54609
Litres to Cubic Metres = Multiply by 0.001
Cubic Metres to UK Gallons = Multiply by 219.
page 27
20
QUANTUM
Safest steriliser
available on the
market, more powerful
than chlorine, ozone,
bromine, hydrogen
peroxide or oxygen.
Powerful
Eliminates unsightly contaminants
such as sun creams and
other organics
Dynamic
Operates with: Salt chlorinated
water, sea water and fresh water
page 28
Quantum uses new ceramic Nano Crystal technology,
a prime focus of the science world today;
possessing the power to sterilise sewage into
drinking water without the use of chemicals.
page 29
WHAT IS
PHOTOCATALYTIC
OXIDATION?
ELECRO.CO.UK
ELECRO.CO.UK
page 30
OXIDATION STRENGTH (EV)
OXIDATION
PHOTOCATALYTIC OXIDATION
89
page 31
I VAT E D - P H O T
TA K E T H E Q U A N T U M L E A P T I N UM
ACT
-
R E M E STERILISA
T
OC
AT
AL
P IO
U S D N
YS
A
S T EST
TA N
PL
RO
Quantum harnesses a revolutionary technology, already used by high-profile industries such as LU
T
YE
OL
hospitals, drinking and waste water purification.
D
P
E
LEGIONELLA
.CO
Takes pool hygiene and water clarity to the ultimate level.
LI
PURE
ATER
Pool water that sparkles like diamonds in a way you have never seen.
PROTO
R W
SKI
OIL
Quantum uses new ceramic Nano Crystal technology: a prime focus of the science world today;
HE
RI
NC
ZO
AN
EA
AL
LE
possessing the power to sterilise sewage into drinking water without the use of chemicals. In fact, one LS
EL
NT
A
SU
CL
W
TH
CR
Y UR
of the many benefits of the Quantum is a significant reduction of residual chemicals, such as chlorine ICS
FO
P EA
L-
ORGAN
Y
TO A
RI
A
U SP
or bromine. N LE S
T
PO OR G Y
LL
IDIUM NAE CR
UT G
ED RIN
SHIMME
Built to be installed easily into your existing set-up, the Quantum is completely safe and significantly
more powerful than chlorine, hydrogen peroxide, UV or ozone. Photocatalytic oxidation has an
immensely powerful effect with the ability to instantaneously destroy viruses, bacteria and pathogens, and more astoundingly possessing the
ability to convert sun tan oil, urea and other contaminants back in to their harmless molecular form.
Meticulously designed, Elecro have developed the first cost effective, photocatalytic oxidiser specifically for the swimming pool industry, for toxin
free swimming. It eliminates undesirable side-effects such as sore eyes, itchy dry skin, discoloured hair and strong odour. It also makes water crystal
clear, and most importantly it creates no risk to the lungs or health of bathers and swimming pool attendants.
PRODUCT OVERVIEW
• Safe: Only pure, sterilised water is released from the reaction chamber.
• Clean: Makes the water sparkle like diamonds in a way never seen before.
• Efficient: Consumes no more electricity than a common light bulb, providing continuous savings.
• Effective: The only technology available with the ability to instantly destroy all viruses, bacteria and pathogens, and like no other
device, will break down oil and contaminants.
• Powerful: The sterilising effect of the Quantum photocatalytic oxidiser (PCO) exceeds the effects of boiling water.
• Easy To Use: Comes pre-assembled with all necessary sensors and control components: no complicated parts to piece together.
The bulb replacement indicator will alert after 14,000 hours of use.
• Easy Installation: Corrosion resistant, regardless of any salt or chemical concentrations in the water. As the reaction surface is
truly catalytic and therefore it is never consumed or altered.
WHY QUANTUM?
With a wide range of products available on the market that offer a variety of
technologies to sanitise swimming pool water, how do you decide what
method is best for you? The table on the right identifies some key players
including chlorine, ozone, hydroxyl radicals, and photocatalytic oxidation at the
top as the strongest and most effective sterilising agent in existence.
Chlorine and ozone are also known to release gas that hovers above the swimming pool and can be hazardous to breathing. In contrast the
photocatalytic oxidation reaction is contained within the reaction chamber releasing only pure, fresh water, clean enough to drink.
Quantum’s advanced cleaning technology replicates nature’s own technique for sterilising our planet, making it habitable. A photocatalytic
oxidiser, known by scientists as “Nature’s Silver Bullet,” neutralises what chlorine cannot and achieves exponential reductions in unwanted
bacteria, pathogens and viruses. Chlorine, ozone and UV are ineffective against Naegleria Fowleri and Adenovirus, whereas photocatalytic
oxidation has proved that nothing escapes it. Built for ease of use – simply set and relax! With the Quantum you are in complete control.
90
page 32
HOW DOES IT WORK? THE SCIENCE
Reaction 1: Quantum Photocatalytic Oxidiser (PCO)
Quantum works in a similar way to a cars exhaust system, where a catalyst uses
the combination of heat and Platinum coated baffles to convert the poisonous
gases coming from the engine into carbon dioxide and water.
Quantum uses light as fuel to energise its sophisticated catalyst array, with rare
elements including Anatase, Molybdenum and Platinum ceramic catalyst, the
resulting reaction that takes place inside the quantum has not only the power
to consume any oils or organics present in the water, it also possesses the
power to abundantly and momentarily split the water molecules into what are
called Hydroxyl Radicals. The combination of effects equip quantum with far
more power to purify water than a chemical oxidising agent, such as chlorine
or bromine.
Hydroxyl Radicals are essentially a water molecule with a hydrogen atom removed, highly reactive, unpaired electron, caused by the
PCO reaction, disturbing the electrons and forming holes in the valance brand of the atom.
The exceptionally mobile molecules that fill the reaction chamber are highly volatile and able to destroy everything in their path.
Once the Hydroxyl Radical has reacted with the pollutant it converts itself back into water.
Hydroxyl Radicals can be made in many ways, however instead of using more chemicals that are damaging to health, the Quantum
utilises photocatalytic oxidation. This is the safest and most effective method against pollutants.
It is a misunderstanding that ozone gas in the ozone layer sterilises the earth’s atmosphere. In fact 85% of the
sterilisation effect is actually a result of UV rays from the sun creating Hydroxyl Radicals on the surface of clouds.
91
page 33
DATE : 06-02-2023
REF: MP021/21/MS/004
MATERIAL SUBMITTAL
PROJECT : G+1 CENTRO MALL
CONSULTANT : DSG
SUB - CONTRACTOR :
CERTIFICATES
page 34
11 Gunnels Wood Park, Stevenage, Herts
SGl 2BH United Kingdom
We, Elecro Engineering Ltd, declare under our own responsibility that the product(s) and
ranges:
Elecro Swimming Pool Heaters; Elecro Aquatic Heaters; E/ecro Heat Exchangers; Elecro
Flow Switches; Quantum, Spectrum Hybrid and H. R UV-C Water Treatment & Thermecro
Solar heating products.
Manufactured by:
CE
Date: 23r� January 2017 Position: Production & Quality Manager
ELEE:RC:J
ENGINEERING
www.elecro.co.uk page 35
Company Reg. No. 03520981 VAT Reg. No. 676 9830 72
EU DECLARATION OF CONFORMITY
ELE8RC:J
ENGINEERING
Declaration No:DOC-001-30-06-2022-V03
The Manufacturer: Elecro Engineering Ltd
Unit 11 Gunnels Wood Park, Stevenage, Hertfordshire, SG1 2BH, UK
Declare that the product{s):
Page 1 of 2
page 36
Low Voltage Directive: 2014/35/EU
IEC 60335-1:2010
IEC 60335-1:201O/AMD1 :2013 Safety of Household and similar electrical appliances-General
IEC60335-1:201O/AMD2:2016 requirements
IEC 60335-2-35:2012
IEC60335-2-35:2012/AMD1 :2016
This declaration of conformity is issued under the sole responsibility of the manufacturer:
Page 2 of 2
page 37
Ref. Certif. No.
GB 8726 Z M1
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB
SCHEME
CB TEST CERTIFICATE
Model / Type Ref. Elecro HR-UV-C, Elecro Quantum, Elecro HR-UVC-SPA, Elecro Quantum Spa
Vulcan Pro Pool, Vulcan Pro Pool Spa
Additional information (if necessary may also be BEAB Ref: IWH 0906
reported on page 2) Revision of National Differences
Original Issue Date: 2022-06-30
Additional information on page 2
A sample of the product was tested and found to be in IEC 60335-1:2010, IEC 60335-1:2010/AMD1:2013, IEC 60335-1:2010/
conformity with AMD2:2016, IEC 60335-2-109:2010, IEC 60335-2-109:2010/AMD1:2013, IEC
60335-2-109:2010/AMD2:2016
National differences:
AE, CN, EU Group Differences, EU Special National Conditions, IL, KR, MX,
SA, TH
As shown in the Test Report Ref. No. which forms part 105214048MKS-002
of this Certificate
page
page 38 1 of 1
DATE : 06-02-2023
REF: MP021/21/MS/004
MATERIAL SUBMITTAL
PROJECT : G+1 CENTRO MALL
CONSULTANT : DSG
SUB - CONTRACTOR :
COUNTRY OF ORIGIN
page 39
E11.GQJ1ibnci:ngineering Limited
Unit 11 Gunnels Wood Park
Stevenage
No. DB 1182856 ORIGINAL
Hertfordshire 49702
SGl 2BH
United Kinadom
Tel No. 01438749414 Fax No. 01438361329
2 Consignee
UNITED KINGDOM
Metro Pools
Building No. 225, Zone 44
Street No. 250, Nuaija
P.O Box: 32163
Doha CERTIFICATE OF ORIGIN
QATAR
5
2 �a'1"f:ts, With black shrink wrap exterior, of
dimensions:
120x80x184cm
120x80x153cm
6 11em number; marks; numbers; number and kind of packages; description of goods 7 Quantity
8 THE UNDERSIGNED AUTHORITY CERTIFIES THAT THE GOODS DESCRIBED ABOVE ORIGINATE IN THE COUNTRY SHOWN IN BOX 3
Hertfordshire Chamber
Of Commerce
CERTIFYING STAMP
•
2 9 APR 2022
� -
Authorised by H.M. Government F HARRIS
l!l:....... . J
�Signeto,y
UK-HER4144-4084114-E
Place and date of issue, name, signature and stamp of competent authority www.ecert.sgs.com
page 40
DTI/XP 13025 LT PRINT GROUP 0151 647 8006 3/2019