Type VAPM 31

Fuse Failure Relay


Type VAPM 31
Fuse Failure Relay

VAPM 31 relay
withdrawn from case

Features the appropriate coil(s) is energised Technical data


and the relay operates immediately
l High speed operation. Coil rating
to open the trip circuit.
l Compact and robust construction. 110V, 50 Hz phase to phase, phase
Successful prevention of false
l Positive action. tripping relies on the high speed of to neutral series impedance of the
the VAPM 31 relay, which operates distance or other relays in series
Application faster than most schemes of with the fuse failure relay should not
protection but cannot begin to exceed 1000 ohms i.e. the voltage
Detection of failure or inadvertent circuit burden should be greater
function until the fuse is completely
removal of voltage transformer than 4VA per phase.
blown. In practice, however, most
secondary fuses and prevention of
VT fuse failures are caused by
incorrect tripping of circuit breakers. Operating time
deterioration or accidental removal
and fuse blowing time is not Time between failure or removal of
General description important. voltage transformer secondary fuses
Type VAPM 31 relay consists of a and opening of normally closed
static rectifier circuit with a long core contact is less than 7m seconds.
hinged armature output unit. Three Refer Figure 1 for time/voltage
coils for the three phases are wound curve.
over a single core producing in
effect a common relay for the three Thermal rating
phases. Each coil is connected 110% of rated voltage continuously.
across one of the voltage
transformer secondary fuses and
Burden
under healthy conditions, this coil is
short circuited by the fuse and 3.5VA per phase at rated voltage
cannot be energised. When one or during operation.
more fuses blow or are removed,
Figure 1: Figure 2:
Operating time of normally closed contact Typical external and internal connections
for type VAPM 31 relay

Dimensions and weights Operation indicator


Maximum overall dimensions Approximate Hand reset operation indicator
Relay Case size Height Width Depth* gross weight provided.
mm mm mm Kg.
VAPM 31 1D 233 170 203 3.5 Contacts

* Add 76 mm for maximum length of terminal studs, alternatively, One make, one break self
29 mm for terminal screws. reset contact. Break contact is
faster in operation than make
The approximate gross weights given above are inclusive of cartons,
contact.
mounting appendages and terminal details.
The relays comply fully with the requirements of IS 3231 and are suitable Insulation
for use in normal tropical environments.
The relay meets the requirements of
IS 3231:1965/IEC 255-5 Series C-2
KV for 1 minute.
Contact ratings
Make and carry Make and carry Break External & internal connections
continuously for 3 seconds
Typical external and internal
AC 1250VA with 7500VA with 1250VA with connections are shown in Figure 2.
maxima of 5A maxima of 30 A maxima of 5 A
and 660V and 660V and 660 V
Information required with
order
DC 1250W with 7500W with 100W (resistive) Operation indicator inscription if
maxima of 5A maxima of 30A 50W (inductive) required.
and 660V and 660V with maxima of
5A and 660V
ALSTOM Limited Pallavaram Works: 19/1, GST Road, Pallavaram, Chennai-600 043. India.
Tel: 91-044-2368621 Fax: 91-044-2367276 Email: plw.applications@alstom.sprintrpg.eml.vsnl.net.in.
© 1998 ALSTOM Limited

Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this brochure should
only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it.
ALSTOM Limited cannot be held responsible for any reliance on any decision taken on its contents without specific advice

PR:068:0799:A Printed in India.

You might also like