SOIL TECH CONSULTANT PW. LTD.

Date: 2079-07-04
New Baneshwor, Kathmandu Sample No: 1
Email: soiltechconsultant@gmail.com Test Standard: NS 163 - 2045
Phone No: 977 -984112289 L, 9823041544 Ref:4060/076/077 (zC)

CABION WIRE TEST RESULT src(!AB)

ect: Construction of R.C.C Bridge over Judi Khola, Bhaudaha -5 & 7, Morang
ient Bridge Division, Sector -1, Dharan, Sunsari
Khampache-Dhulikhel-Himalayan JV, Baneshwor
No SM BCP/WN CB-22 I 06 5 / O 6 6
I Wire Premier (Heary Coated)

A. OBSERVATIONS
Original Zinc Tensile Uniformity of Zinc Coating
S.N Cauge Diameter Coating Strength Required No. of Remarks
Results
(mm) (gm/m2) (kg/mm2) l min l/2 min
1 8 3.943 383.2t 39.12 J I Copper deposition not seen
2 8 3.938 379.98 38.54 J 1 Copper deposition not seen
-) 8 3.929 365.56 38.17 ) i Copper deposition not seen
4 10 3.011 289.54 40.16 J i Copper deposition not seen
5 10 3.021 281.61 40.86 J I Copper deposition not seen
6 i0 3.043 293.32 41.23 J i Copper deposition not seen
7 12 2.652 261.43 42.66 J Copper deposition not seen
8 12 2.665 2s8.66 43.1 8 3 Copper deposition not seen
9 12 2.519 262.23 11
^a J Copper deposition not seen.

Suraj D
htfk
K.B Dhan\a
Checked
NOTE: ABOVE SAMPLES ARE PROVIDED BY THE CONTRACTOR.