Constructor: Polifer . SAL Project: Lycee francaise , canopy Developer time: 10 mins, minimum
Base Metal: Carbon Steel Product brand: Elite Flaw-Findr (Italy) Removal method: Water jet or solvant
PT Method: Visible Dwell time: 20 mins , minimum Ref WPS: APPROVAL Constructor
Acceptance: AWS D1.1 Total Tested: 19.2 linear m
sig.
elongated porosity
agregeate porosity
alligned porosity
pipe prosity
spherical porosity
lack of thikness
crack
Non - Tubular
lack of fusion
Dia (inch) / Length (mm)
crown undercutting
miss allignement
lack of penetration
Retassures
root
Tubular
metallic Inclusion
slag Inclusion
Joint Number
sasundercutting
Constructor
defaut
Final APPROVAL Client
Inspector
End user
Date
ROOT
sig.
F+C
Observations
HEA - J 1 - H N/A N/A 600 15.5 x x x A A Within AWS D1.1 tolerannce
HEA - J 2 - H N/A N/A 600 15.5 x x A A Within AWS D1.1 tolerannce
HEA - J 3 - H N/A N/A 600 15.5 x x R A A Repaired to meet AWS D1.1 / Accepted
HEA - J 4 - H N/A N/A 600 15.5 x x x x A A Within AWS D1.1 tolerannce
HEA - J 5 - L N/A N/A 600 15.5 x x A A Within AWS D1.1 tolerannce
HEA - J 6 - L N/A N/A 600 15.5 x x A A Within AWS D1.1 tolerannce
HEA - J 7 - L N/A N/A 600 15.5 x x A A Within AWS D1.1 tolerannce
HEA - J 8 - L N/A N/A 600 15.5 x x x A A Within AWS D1.1 tolerannce
IPE - 4 - U joint N/A N/A 1800 7.1 x x A A Within AWS D1.1 tolerannce
IPE - 6 - U joint N/A N/A 1800 7.1 x A A Within AWS D1.1 tolerannce
IPE - 9 - U joint N/A N/A 1800 7.1 x x A A Within AWS D1.1 tolerannce
IPE - 10 - U joint L N/A N/A 1800 7.1 x A A Within AWS D1.1 tolerannce
IPE 11 - U joint N/A N/A 1800 7.1 x A A Within AWS D1.1 tolerannce
IPE - 0 - U joint N/A N/A 1800 7.1 x x A A Within AWS D1.1 tolerannce
IPE 19 - U joint N/A N/A 1800 7.1 x A A Within AWS D1.1 tolerannce
IPE 20 - U joint N/A N/A 1800 7.1 x x A A Within AWS D1.1 tolerannce
IPE 11
legend A : Accepted R:A réparer/
REPAIR C:A couper/
CUT