09910510021
Arch
SA/072123.1 Dated
To,
Mr.
Mob,
Subject: Technical and commercial specification for Industrial shed for your site.
Dear Sir,
We are thankful to you and your organization for giving us your valuable enquiry for
supply and erection of Industrial Shed.
Based on the information provided by you, we submit our proposal (Enclosed) for
your kind Consideration.
We shall be extremely obliged if your organization extends an opportunity to work with us.
Deep Shikha
9540001107, 9990444520
Design Loads: ( Refer to Section 2 'Applicable Design Live Load (KN/m2) on purline – 0.57
17
Codes' of this offer) Design Live Load ( KM/M2) on frame - 0.57
Wind Speed (kmph) - 169.2
Collateral Load (KN/m2) - 0
Snow Load (KN/m2) - 0
Earthquake Zone - Zone II
Regd. Office : 308, 309 MSX Tower-1, Alpha-1 G.Noida, U.P-201306
Phone : 0120-4250004, 9910510021, 9540001107
E-Mail : S terlingarch@gmail.com , Website :
www.sterlingarch.com
Sterling
Surendra Bansal-
09910510021
Arch
18 Steel Work Finish Primary Steel
All primary steel members will be cleaned by sand blasting and will
be applied with one quote of red oxide at Factory of 35 microns
DFT and two coat of synthetic enamel paint.
Secondary Steel
All other secondary steel members (Wind columns, Base
angles, Angle, Clips, Brace Rod, Gable
Angles, Flange stays and other small misc. items will be
cleaned and applied with one quote of primer at our factory.
Applicable Codes
All buildings included in this proposal are designed in
accordance with following codes.
Arch Deflections
Main Frame Vertical L/180
19 Main Frame Lateral EH/100
Purlins L/180
1 Built-Up Members ASTM A 572M Grade 345 TYPE 1 (or) its Fy= 34.5 Kn/cm2
Equivalent
Hot -Rolled Members
Beams & Columns IS 2062: 2006 Grade A (or) its Equivalent Fy= 25.0 Kn/cm2
Tubes IS 4923: 1997 Fy= 31.0 Kn/cm2
Channels IS 2062: 2006 Grade A Fy= 25.0 Kn/cm2
Pipes/ Handrails IS 1239 (PART(Part) : 2004- Class 1, Fy= 21.0 Kn/cm2
Medium
2 Cold Formed Secondary
Members
Galvanized Steel ASTM A 653 M SS Grade 340 Class 1, Fy= 34.5 Kn/cm2
Coating Z275
3 Sheeting & Liner Panels
Zincalume Steel ASTM A 792M Grade 345 Type B, Coating Fy= 34.5 Kn/cm2
AZM 150
Aluminum ASTM B 209M Alloy 3003 Temper H-26 Fy= 14.5 Kn/cm2
4 Hot Zinc Coating of steel ASTM F2329
IS- 4736 (1986)
5 Valley Gutters
Galvanized Steel ASTM A 653M SS Grade 340 Class 1, Fy= 34.5 Kn/cm2
Coating
Z275
6 Mezzanine Deck Panels
Galvanized Steel ASTM A 653M SS Grade 340 Class 1, Fy= 34.5 Kn/cm2
Coating
Z275
7 X- Bracing Members
Rods IS 2062: 2006 Grade A Fu= 41.0 Kn/cm2
Angles IS 2062: 2006 Grade A Fu= 41.0 Kn/cm2
8 Anchor Bolts ASTM A 325 M (or) its Equivalent, Fu= 25.0 Kn/cm2
Black Bolts Fu= 40.0 Kn/cm2
9 High Strength Bolts ASTM A 325M Class 8.8 Type 1 , Fu= 83.0 Kn/cm2
Electro galvanized
10 Machine Bolts DIN 933 Class 4.6/4.8 Fu= 40.0 Kn/cm2
Electro Plated Yellow Chromate
Other gutter will usually be made from the materials used for
sheeting. FY= Yield Strength, Fu = Ultimate Tensile Strength.
Arch
General Term & Conditions:
1. Clear height of PEB has been considered 25 ft.
2. Steel structure will be pre primer (Red oxide) finished and two quotes of
synthetic enamel paint.
3. Doors, windows and rolling shutters are excluded.
4. Glazing, plumbing, electrical etc. are also excluded.
5. Drawings for client approval will be submitted within 7 days after receipt of valid
work order and advance.
6. Material will be supplied within 6-8 weeks & work will be completed within 8-12 weeks from the
date of the issue of work order
Payment Terms:-
Supply: 45% advance and balance against Performa invoice.