QUALITY CONTROL OBSERVATIONS

Report No. 14 15/06/2023


S.No. Observations Photographs
1. Academic
block, terrace,
above 90
seater
classrooms
(Part 3)- Poor
finishing of the
parapet wall

Report No. 14 Page 1 of 33


2. Academic
block, terrace,
above 90
seater
classrooms
(Part 3)-
Misaligned
chiller plant
foundation

Report No. 14 Page 2 of 33


3. Academic
block, terrace,
above 90
seater
classrooms
(Part 3)-

Difference in
parapet wall
height along
one stretch of
wall

Report No. 14 Page 3 of 33


4. Academic
block, terrace,
above 90
seater
classrooms
(Part 3)-

Wavy parapet
wall alignment

Report No. 14 Page 4 of 33


5. Academic
Block, near
student
entrance and
auditorium-

Poor finishing
of the exterior
walls and the
column pillars
are not straight
and
misaligned,
need
correction

Report No. 14 Page 5 of 33


6. Academic
Block, near
student
entrance and
auditorium-

Poor finishing
of the exterior
walls and the
column pillars
are not straight
and
misaligned,
need
correction

Report No. 14 Page 6 of 33


7. Academic
Block, near
reception area-

Poor finishing
of the exterior
walls, need
correction

Report No. 14 Page 7 of 33


8. Medical
Centre-

window sills ,
granite stone
joints left
improperly
filled

Report No. 14 Page 8 of 33


9. Medical
Centre-

Bent door
section and
gap between
wall and door
frame not
packed

Report No. 14 Page 9 of 33


10. Medical
Centre-

Unmoulded
edges from
inside of
window sill

Report No. 14 Page 10 of 33


11. Medical
Centre-

Skirting
hollow from
inside

Report No. 14 Page 11 of 33


12. Medical
Centre-

Improperly
finished wall,
not straight

Report No. 14 Page 12 of 33


13. Medical
Centre-

Improper
positioning of
the fan

Report No. 14 Page 13 of 33


14. Medical
Centre-

Misaligned
ceiling lights

Report No. 14 Page 14 of 33


15. Medical
Centre-

Unfinished
joint with gap

Report No. 14 Page 15 of 33


16. Medical
Centre-

Uneven
thickness of
the window sill

Report No. 14 Page 16 of 33


17. Medical
Centre-

Crack
propagating
along the wall

Report No. 14 Page 17 of 33


18. Medical
Centre-

Wall finishing
improperly
done

Report No. 14 Page 18 of 33


19. Medical
Centre-

Uneven gap
between porch
ceiling and
false ceiling

Report No. 14 Page 19 of 33


20. Academic
Block ESS 1;-

Skirting of the
machine
foundation left
hollow

Report No. 14 Page 20 of 33


21. Academic
Block ESS 1;-

Leakage of
water at the
panel room
from the
retaining wall

Report No. 14 Page 21 of 33


22. Academic
Block ESS 1;-

The CC
foundation is
already
wearing out

Report No. 14 Page 22 of 33


23. Academic
Block-

Pillars at
student
entrance are
not straight

Report No. 14 Page 23 of 33


24. Behind
Academic
Block near
MDP building-

The retaining
wall has
developed
cracks

Report No. 14 Page 24 of 33


25. Hostel 1-

Gaps in the
fitting of kota
stone at
staircase,
staircase edges
not finished
properly

Report No. 14 Page 25 of 33


26. Hostel 1-

3rd floor
staircase from
the side,
improperly
finished
surface of wall

Report No. 14 Page 26 of 33


27. Hostel 1-

3rd floor porch


wall requires
proper
finishing

Report No. 14 Page 27 of 33


28. Hostel 1-

Left side and


Right side of
the black
granite stone
are different in
length

Report No. 14 Page 28 of 33


29. Hostel 1-

Front of the
hostel, gaps
between the
kerb stone are
not filled and
the gaps are
bigger

Report No. 14 Page 29 of 33


30. Hostel 1-

Unevenly
finished
sidewalk

Report No. 14 Page 30 of 33


31. Hostel 3-

Side and back


wall of the
hostel is are
not straight

Report No. 14 Page 31 of 33


32. Hostel 3-

Front portion
of the hostel,
the kerb stones
are damaged

Report No. 14 Page 32 of 33


Thank You.

Report No. 14 Page 33 of 33