Date :- July 19, 2006

To:- ..................................................

Subject:- Soil Test Request

Site :- Addis Ababa Yeka Sub- City,

Owner:- . Ato Tadess Dori

Dear Sir,

The Exploration of the site shall include Drilling, Sounding and GWT measurements to
be conducted on the boreholes (BH1, BH2 & BH3) as indicated on site plan.

Test Programs

 Conduct drilling of BH1, BH2 & BH3 to a maximum depth of 10mts.


 When Rock strata is Encountered at shallower depth, the drilling shall extend at
least 2mts in to rock and 3mts into weathered rock.
 Conduct SPT test at 2,3,5&7mts for BH1, BH2&BH3.
 Indicate GWT if encountered
 Conduct the following laboratory tests for samples obtained from BH1, BH2 &
BH3 at depth of 2mts and 4mts
o Grain size and atter berge’s limit.
o Free swell for highly plastic clay
 TCR & RQD
 Recommend bearing capacity.

With best regard