You are on page 1of 2

DEPTH DETERMINATION OF SLABS

Minimum effective depth is provided by the following formula: (EBCS -2, 1995 Sec.5.2.3)

d=(0.4+0.6fyk/400)Le/ba

Panel Type Case No.= 4 Ly


Fck 20.00 Fcd 11.33 0
Fyk 300.00 Fyd 260.87

COVER 15 BAR DIA. 10 Lx 0 S-1 1

ba for 2:1 ba for 1:1 Ratio calc. ba calc 1


30.00 40.00 1.03 39.69 1 -Continuous
0 -Discontinous
Panel Name S-1
Depth Lx [m] Ly [m] ba calc d [mm] D [mm]
3.20 3.30 39.69 68.54 90.00

Panel Type Case No.= 4


0
ba for 2:1 ba for 1:1 Ratio calc. ba calc

30.00 40.00 1.25 37.50 1 S-2 0

Panel Name S-2 1


Depth Lx [m] Ly [m] ba calc d [mm] D [mm] 1 -Continuous
3.20 4.00 37.50 72.53 100.00 0 -Discontinous

Panel Type Case No.= 2


1
ba for 2:1 ba for 1:1 Ratio calc. ba calc

30.00 40.00 1.82 31.82 1 S-3 0

Panel Name S-3 1


Depth Lx [m] Ly [m] ba calc d [mm] D [mm] 1 -Continuous
2.20 4.00 31.82 58.77 80.00 0 -Discontinous

Panel Type Case No.= 4


1
ba for 2:1 ba for 1:1 Ratio calc. ba calc

30.00 40.00 1.25 37.50 1 S-4 0

Panel Name S-4 0


Depth Lx [m] Ly [m] ba calc d [mm] D [mm] 1 -Continuous
3.20 4.00 37.50 72.53 100.00 0 -Discontinous

Cantilevers
1
Panel Name CS-1

Depth Lx [m] Ly [m] ba calc d [mm] D [mm] 0 CS-1 0


1.21 4.00 10.00 102.85 130.00
0
1 -Continuous
0 -Discontinous

So the maximum of the above calculated values= 130.00 mm


For purposes of different sanitory installation purposes lets use D= 150 mm