Septic Tank Capacity for a 5 Unit Apartment?

(1 Point)

5.7 cu.m

2.8 cu.m

8.5 cu.m

3.8 cu.m
2
minimum distance of watercloset center from side wall for PWD? (1 Point)

450 mm

300mm

350 mm

460mm
3
where is the check valve located from Septic Tank Capacity for a 5 Unit Apartment?
(1 Point)

5.7 cu.m
2.8 cu.m
8.5 cu.m
3.8 cu.m
2
minimum distance of watercloset center from side wall for PWD?
(1 Point)
450 mm
300mm
350 mm
460mm
3
where is the check valve located from the water main supply?
(1 Point)
before the water meter
after the water meter
4
In, plumbing, what does PSI mean?
(1 Point)
Pounds per square inch
Perfect System Instrument
Point system input
Place Setting-In
Pinaka Super Ingat
5
WATERLINE Sizing: What should be the waterline pipe size for a PVC Pipe, considering a velocity of
1.5m/s, 85WSFU equivalent to 2.5L/s or 39.6gpm?
(5 Points)

19mm
25.4mm
44.5mm
38mm
12.7mm
6
waterlines should always be above soil pipes to prevent any possible contamination on leaks
(1 Point)
true
false
7
which among the following is a threaded pipe?
(1 Point)
Polypropylene random Pipe
Polybutylene Pipe
polyvinylchloride Pipe
cast iron Pipe
Polyethylene Pipe
Galvanized Iron Pipe
8
for a private use house, which has 1 flush tank water closet, 1 lavatory, 1 sink/dishwasher, 1 shower
head, WHAT IS ITS TOTAL F.U.?
(3 Points)

15 F.U.
4 F.U.
8 F.U.
30 F.U.
9
which among the following are NOT banned pipe material. select all
(5 Points)
Lead Pipe
Polyethylene Pipe
Polypropylene random Pipe
Galvanized Iron Pipe
Asbestos Pipe
Polybutylene Pipe
polyvinylchloride Pipe
10
the fire hose cabinet is linked/connected to what?
(2 Points)
dry stand pipe
wet stand pipe
11
a good practice is to NOT label the type and direction of flow in the pipes
(1 Point)
wrong
right
12
DWV Sizing: What should be the pipe size for the VENT STACK if the DFU is 200?
(5 Points)

6 inches
4 inches
2 inches
8 inches
3 inches
13
vent pipes connected to the vent stack
(1 Point)
circuit vent
vent stack
loop vent
wet vent
14
DWV Sizing: What should be the pipe size for the WASTE STACK if the DFU is 35?
(5 Points)

8 inches
3 inches
2 inches
6 inches
4 inches
15
how far should the septic tank be from any on-site waterline?
(1 Point)

15.2m
2.4m
3m
1.5m
16
simplify your plumbing design to be easily understood by post-contruction maintenance crew, more
efficient flow in the system and less material cost.
(1 Point)
true
false
17
in order to compute for the pump and/or pipe size, you need to first know how many fixture units you
will be servicing.
(1 Point)
false
true
18
vertical vent line that collects all horizontal vent lines
(1 Point)
vent stack
wet vent
loop vent
circuit vent
19
is the transfer pump/booster pump ALLOWED to directly be connected to the waterline WITHOUT a
CISTERN TANK/ WATER TANK?
(1 Point)
Maybe
Yes
No
20
1.42 psi is needed to lift water by 1 m. How PSI is required to lift the water by 6 meters and add 15psi
more for fixture's working pressure
(3 Points)
23.52 psi
8.52 psi
21 psi
18.52 psi
21
what is this plumbing symbol?
(1 Point)
B&S tee outlet down
B&S tee outlet up
Screwed tee outlet down
Flanged tee outlet down
22
also called leader and leads the rainwater from the gutter to the catch basin
(1 Point)
gutter
catch basin
downspout
p-trap
grease trap
septic tank
23
in Plumbing Design always consider other systems such as architectural, mechanical, especially
structural systems and electrical & electronic systems
(1 Point)
false
true
24
minimum distance of watercloset center from side wall for ordinary person?
(1 Point)
460mm
300mm
350 mm
450 mm
25
DWV Sizing: What should be the pipe size for the VENT BRANCH if the DFU is 20?
(5 Points)

4 inches
6 inches
2 inches
8 inches
3 inches
26
In, plumbing, what does GPM mean?
(1 Point)
PSI
GPM
TDH
DFU
WFU
27
how far should the septic tank be from the water main?
(1 Point)
15.2m
2.4m
1.5m
3m
28
LEADER Sizing: What should be the pipe size for each 6 downspouts on a 600 sqm Roof Area? Rainfall is
102mm/hr 
(5 Points)

2 inches
8 inches
4 inches
3 inches
6 inches
29
Septic Tank Capacity for a 3 Bedroom Residence?
(1 Point)
3.8 cu.m
5.7 cu.m
2.8 cu.m
8.5 cu.m
30
maximum lavatory height mounting
(1 Point)

1000mm
850mm
900mm
500mm
31
Septic Tank Capacity for a 33 DFU bldg?
(1 Point)
8.5 cu.m
5.7 cu.m
3.8 cu.m
2.8 cu.m
32
DWV Sizing: What should be the pipe size for the SOIL STACK if the DFU is 650?
(5 Points)

6 inches
2 inches
3 inches
4 inches
8 inches
33
all fixtures must be _______
(1 Point)
clean out
vented
34
what is this plumbing symbol?
(1 Point)

Screwed tee outlet down


B&S tee outlet down
Flanged tee outlet down
B&S tee outlet up
35
if pipes will pass thru structural elements, use pipe sleeves which are one pipe size larger to the pass
thru pipe
(1 Point)
true
false
36
the diameter of waterline pipe
(1 Point)
x
y
'D' (exterior dimension)
'd' (interior dimension)
37
vent pipes connected to a battery (row) of fixtures; connection is before the first fixture and at the last
fixture.
(1 Point)
loop vent
circuit vent
wet vent
vent stack
38
refrain from embedding pipes on structural systems to preserve structural integrity. Provide a pipe
chase to organize pipes and for easier maintenance
(1 Point)
wrong
right
39
maximum Septic Tank Liquid Depth?
(2 Points)
0.6m
2.0m
1.8m
1.5m
2.4m
40
minimum shower drain pipe size?
(1 Point)
3 inches
4 inches
2 inches
41
many bends in water line may cause
(1 Point)
nothing
cheap
friction loss and pressure loss
broken
42
cold water line symbol
(1 Point)
long short short long
long short long
cont. solid line
hidden line
43
spacing of sprinkler head for light hazard?
(2 Points)
3.7m
4.6m
1.8m
44
how far should the septic tank be from the property line?
(1 Point)

1.5m
15.2m
3m
2.4m
45
the concern of this professional is all piping, tanks and other distribution of liquids 0.6m INSIDE the
building regardless of the building height or number of storeys
(1 Point)
sanitary engineer
electrical engineer
plumbing engineer/master plumber
architect
46
horizonal pipe
(1 Point)
circuit
riser
stack
branch
47
size of a pipe sleeve for a 2" diameter pipe
(1 Point)
2 inches
3 inches
4 inches
6 inches
48
the following has a hub and spigot and is caulked?
(1 Point)

Galvanized Iron Pipe


Polybutylene Pipe
Polypropylene random Pipe
Polyethylene Pipe
cast iron Pipe
49
GPM per sprinkler head?
(2 Points)
20gpm
100 gpm
50gpm
10gpm
50
which among the following is most probable to rust/corrode?
(1 Point)
Polypropylene random Pipe
Polyethylene Pipe
polyvinylchloride Pipe
Galvanized Iron Pipe
Polybutylene Pipe
51
which among the following is a good working pressure for a household
(1 Point)
40psi
100psi
10psi
15psi
52
how far should the septic tank be from water supply wells?
(1 Point)

15.2m
2.4m
3m
1.5m
53
minimum shower head height
(1 Point)
2.7m
1.5m
1.8m
3m
54
A waste pipe that also serves as a vent pipe
(1 Point)
circuit vent
loop vent
wet vent
vent stack
55
how far should the septic tank be from the buildings or structures?
(1 Point)

1.5m
3m
2.4m
15.2m
56
in every change in direction, provide a ___ for easy maintenance
(1 Point)
clean out
vented
57
the diameter of sewerline pipe
(1 Point)

x
'D' (exterior dimension)
y
'd' (interior dimension)
58
In, plumbing, what does FU mean?
(1 Point)
Fogi points Unit
Fafa Uod
Fixed Unit
Fixture Unit
59
Drain your kitchen sink wastes directly to the septic tank
(1 Point)
false
true
60
DWV Sizing: What should be the pipe size for the HOUSE DRAIN if the DFU is 2500?
(5 Points)
8 inches
3 inches
2 inches
4 inches
6 inches
61
preferable minimum PSI for a fixture to work properly?
(1 Point)
40psi
30psi
20psi
60psi
62
what fitting should be used if the connection if BRANCH SOIL PIPE drains down to SOIL STACK?
(5 Points)
Elbow
Wye
Tee
Sanitary Tee
63
minimum Septic Tank Width?
(2 Points)
0.9m
1.2m
2m
0.6m
1.5m
64
  Preferred Duration for a Fire Reserve Tank? 
(2 Points)
2 hrs
1.5hrs
60mins
30mins
65
GPM per fire hose cabinet?
(2 Points)
20gpm
100 gpm
10gpm
50gpm
66
for a private use house, which has 1 flush tank water closet, 1 lavatory, 1 sink/dishwasher, 1 shower
head, WHAT IS ITS RESULTING FLOW RATE?
(2 Points)
12.8 gal/min
17.5 gal/min
8 gal/min
19.8 gal/min
67
Plumbing lines should always be away and below any electrical/electronic device or line to prevent
electrocution or any malfunctions.
(1 Point)
false
true
68
what is the HP of the pump if: the total dynamic head that includes for friction loss is 120ft, flow rate is
12.8 gpm specific gravity of water is 1.0
(5 Points)

0.3 HP
0.5 HP
1.0 HP
0.35 HP
69
the difference between a STACK-VENT and a VENT-STACK is that the STACK-VENT is a continuity of a soil
stack while the VENT STACK is purely a vent pipe all through-out.
(1 Point)
true
false
70
what is the HP of the pump if: the total dynamic head that includes for friction loss and desire psi for
fixtures is 120 ft, Reqd flow rate is 50 gpm
(5 Points)

2 HP
1.5 HP
1.0 HP
0.75 HP
71
to preserve structural integrity, always check the location of beams and columns to check if your pipes
may pass below or near them. As much as possible do NOT pass through them, provide a pipe chase
(1 Point)
true
false
72
sprinkler system fire protection lines (wet stand pipes) should be with the electrical and electronic lines
(1 Point)
true
false
73
LEADER Sizing: What should be the pipe size for each 4 downspouts on a 600 sqm Roof Area? Rainfall is
152mm/hr 
(5 Points)

4 inches
6 inches
3 inches
2 inches
8 inches
74
if a community population is 100, and 150L per capita per day is allotted, what should be the capacity of
their water tank for a day?
(1 Point)
150 Cu.m
15 cu.m
15,000 Gallons
150,000 Liters
75
professional in charge for FIRE PUMP and FIRE RESERVOIR
(1 Point)
Architect
Professional Mechanical Engr
Professional Electronics Engr
Plumbing Engr/Master Plumber
76
a lavatory is a
(1 Point)
accessory
fitting
fixture
furniture
77
AVERAGE WATER CONSUMPTION OF A PERSON IN A HOUSE is 4000 Lt a month. A household has 5
members. What should be the capacity of the water tank to have sufficient supply for 3 days?
(4 Points)
1 cu.m
2 cu.m
3 cu.m
4 cu.m
78
which among the following is a fusion welded pipe?
(1 Point)
Polypropylene random Pipe
cast iron Pipe
Galvanized Iron Pipe
polyvinylchloride Pipe
Polyethylene Pipe
Polybutylene Pipe
79
which among the following is flow rate "Q"?
(1 Point)
WFU
TDH
PSI
GPM
DFU
80
a 90degrees elbow is a
(1 Point)
accessory
fitting
furniture
fixture
81
Best Pipe slope for soil pipe branches
(1 Point)
1%
45 degrees
2-3%
82
the vent branch should be at least 6 inches higher than the ______ of the sanitary fixture
(1 Point)
p-trap
waste pipe
gate valve
flood level rim
83
it is best to provide a filter in your waterline before it enters the building
(1 Point)
true
false
84
gray water wastes may contain soap and may kill septic tank bacteria
(1 Point)
false
true
85
professional in charge for FIRE PROTECTION LINES
(1 Point)
Architect
Professional Mechanical Engr
Plumbing Engr/Master Plumber
Professional Electronics Engr
86
Minimum Septic Tank Capacity?
(1 Point)

8.5 cu.m
5.7 cu.m
3.8 cu.m
2.8 cu.m
87
Septic Tank DIGESTIVE CHAMBER Capacity for a 20 DFU bldg?
(2 Points)

2.5 cu.m
2.8 cu.m
1.8 cu.m
2.97 cu.m
88
each type of sanitary fixture has a fixture unit, all determined based on the rate of discharge and
frequency of use (either for private or public use).
(1 Point)
true
false
89
AVERAGE WATER CONSUMPTION OF A PERSON IN A HOUSE is 4000 Lt a month. A household has 3
members. What should be the capacity of the water tank to have sufficient supply for 3 days?
(4 Points)
2 cu.m
3 cu.m
1 cu.m
1.5 cu.m
90
In, plumbing, what does TDH mean?
(1 Point)
true direction high
total distance height
time distance head
total dynamic head
91
vertical water line pipe
(1 Point)
stack
riser
upper
vent
92
also called "alulod", a trough along the eaves to catch and carry off rainwater
(1 Point)
downspout
grease trap
p-trap
gutter
septic tank
catch basin
93
How many liters in 1 gallon?
(1 Point)
3.5
3.785 L
3.85 L
4L
94
what fitting should be used if the connection if SOIL STACK drains toward the HOUSE DRAIN?
(5 Points)
Elbow
Wye
Tee
Sanitary Tee
95
collects oil and food wastes from kitchen sinks, this prevents food debris and oil in clogging and
contaminating on the public storm drain
(1 Point)
gutter
grease trap
septic tank
catch basin
downspout
p-trap
96
spacing of sprinkler head for ordinary hazard?
(2 Points)
1.8m
3.7m
4.6m
97
minimum PSI for a fixture to work properly?
(1 Point)
30psi
15psi
40psi
60psi
98
a plumbing fitting designed to create a TRAP SEAL to prevent unwanted sewer gases from escaping the
pipes and leaking the fowl smell in the buildings; while still allowing waste water to pass through.
(1 Point)
downspout8
p-trap
grease trap
catch basin
septic tank
gutter
99
the concern of this professional is all piping, tanks and other distribution of liquids 0.6m OUTSIDE the
building
(1 Point)
sanitary engineer
electrical engineer
architect
plumbing engineer/master plumber
100
1.42 psi is generate if water is elevated by 1 m. How high should the overhead water tank's bottom
should be elevated to achieve 20psi?
(3 Points)
20m
28m
14m
14.3m
101
Minimum Time Duration for a Fire Reserve Tank?
(2 Points)
30mins
1.5hrs
2 hrs
60mins
102
what is this plumbing symbol?
(1 Point)

Flanged elbow outlet up


Screwed elbow outlet down
B&S elbow outlet up
B&S elbow outlet down
103
DWV Sizing: What should be the pipe size for the WASTE BRANCH if the DFU is 35?
(5 Points)
2 inches
4 inches
6 inches
3 inches
8 inches
104
hot water valves is always located on
(1 Point)

right side
left side
center
105
Bends/Elbows for Soil Pipes?
(1 Point)
1/8 bend
1/4 bend
106
how far should the septic tank be from streams?
(1 Point)
1.5m
3m
2.4m
15.2m
107
installed in the structural member to allow the pipe to pass through it. It allows seismic movements,
easier maintenance and also protect the pipe and insulation from chafing as the pipe expands and
contracts in its normal thermal cycle.
(1 Point)
pipe sleeve
hanger
pipe chase
vent
108
what is this plumbing symbol?
(1 Point)

B&S elbow outlet up


B&S elbow outlet down
Flanged elbow outlet up
Screwed elbow outlet down
109
DWV Sizing: What should be the pipe size for the SOIL STACK if the DFU is 53?
(5 Points)
4 inches
8 inches
2 inches
6 inches
3 inches
110
a toilet bowl is a
(1 Point)
fixture
fitting
furniture
accessory
111
how far should the septic tank be from trees?
(1 Point)

15.2m
3m
2.4m
1.5m
112
to minimize the public storm drain from accumulating too much dust from our roofs.
(1 Point)
septic tank
downspout
p-trap
grease trap
gutter
catch basin
113
hot water line symbol
(1 Point)

long short short long


long short long
cont. solid line
hidden line
114
air chamber height
(1 Point)
150mm
300mm
2.7m
3m
115
where is the gate valve located from the water main supply?
(1 Point)
after the water meter
before the water meter
116
why is an air gap maintained and is a concern in waterline installation?
(1 Point)

not true
to prevent backflow and contamination
to prevent splash
to prevent getting wet
117
How many liters in 1 cubic meter?
(1 Point)
100 L
3785 L
1500 L
1000 L