Hot bleed-air from the APU bleed-air duct goes through the pressure regulating valve
11HC and the trim-air valve 12HC. It then mixes with air from the cabin before going to the
AFT cargo compartment. This air enters the supply duct upstream of the inlet isolation-
valve 34HN.
Proximity switches are installed at the AFT cargo-compartment door and at the bulk
cargo-compartment door. These switches will inhibit the AFT cargo-compartment heating
system if one of the doors is open. Both doors must be closed to enable the heating
system to function.
The temperature control system ( Aft Cargo Heating Controller 10HC ) regulates the
amount of hot air added, to give the preselected temperature in the AFT cargo
compartment. The heating controller 10HC, which gets information from the temperature
sensors 13HC and 14HC, controls the system. These sensors are installed in the inlet duct
(13HC) and at the extraction duct of the Cargo Compartment (14HC).
The temperature of the air, which enters the supply duct, is controlled to a maximum of 70
DEG.C (158.00 DEG.F) by the trim-air valve 12HC.When the duct temperature goes above
88 DEG.C (190.40 DEG.F), the FAULT light on the HOT AIR switch 16HC comes on and the
pressure regulating-valve 11HC closes. This overheat condition is latched by the heating
controller ( 10HC ). When the duct temperature decreases to 70 DEG.C (158.00 DEG.F) the
system can be reset. To do this you must push the HOT AIR switch 16HC OFF and then ON
again.
The temperature range that the selector can set is between 5 DEG.C (41.00 DEG.F) and 26
DEG.C (78.80 DEG.F) with 15.5 DEG.C (59.90 DEG.F) at the 12 o’clock position. However, if the
temperature is, for example, already 15 DEG.C (59.00 DEG.F), the adjusting range lies
between 15 DEG.C (59.00 DEG.F) and 26 DEG.C (78.80 DEG.F).
A hot trim-air valve 12HC is installed in the trim air supply duct to the AFT cargo
compartment. The valve also has mechanical stops and limit switches. The limit switches
stop the valve opening or closing more than their preset position and the mechanical
stops are a backup. A manual override and a visual position-indicator are installed on the
end of the shaft. The step counter of the controller 10HC counts the steps of the stepper
motor to calculate the position of the valve butterfly for indication on ECAM. A return

https://airbus.work/ata21/cargo-compartment-heating/ 4/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

spring closes the trim-air valve 12HC if the power supply or the controller 10HC do not
operate.

The pressure regulating valve (11HC) is used to control the pressure of the hot trim air
supply to 4 psi above cabin pressure. The secondary function is to provide a shut-off
facility to the aft cargo compartment. This butterfly type valve is under normal conditions
actuated by a pneumatic actuator and controlled by a regulator. The valve is activated
when the solenoid is energized.The valve can be operated manually and includes a visual
position indicator. A limit switch indicates closed/not closed to the ACSC (47HH) and to the
ECAM system.
The ventilation controller 10HN sends a signal to the heating controller 10HC to close the
trim air valve 12HC if there is : a Fan Fault (35HN) or an ISOL valve closed (33HN, 34HN).
The AFT ISOL VALVE switch  36HN is installed on panel 22VU in the cockpit overhead panel. It
controls the isolation valves 33HN, 34HN and the extraction fan 35HN. The cargo
ventilation controller 10HN will only start the fan if a fully open signal is received from both
isolation valves( 33HN & 34HN ). With the isolation valve switch  36HN pressed-in , the
isolation valves 33HN and 34HN open fully and the extraction fan 35HN starts. With the
isolation valve switch pressed-out, OFF light comes on white, the isolation valves close and
the extraction fan stops. The FAULT light comes on amber if either isolation valve is not
fully open or fully closed. If there is an isolation valve disagree (not fully open or not fully
closed) the ventilation controller will also send a signal to the Flight Warning Computer 
(FWC).If there is an extraction fan fault, the ventilation controller gives a signal to the FWC

https://airbus.work/ata21/cargo-compartment-heating/ 5/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

via the ACSC1 47HH which generates the appropriate failure message for the Centralized
Fault-Display System (CFDS) (Ref. 21-63-00 or 31-32-00).

https://airbus.work/ata21/cargo-compartment-heating/ 6/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

https://airbus.work/ata21/cargo-compartment-heating/ 7/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

https://airbus.work/ata21/cargo-compartment-heating/ 8/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

Cargo compartment temperature :14HC


Duct inlet temperature :13HC
TASK 21-43-00-810-817-AAFT Cargo Temperature Sensor Fault

-AFT CARGO DUCT SENSOR (13HC).

-AFT CARGO COMP SENSOR (14HC (http://airnav.vietnamairlines.com:8000/airnavx/search/text?


q=&wc=actype:A318;actype:A319;actype:A320;actype:A321;customization:HVN;fin:14HC&multimsn=true

Job need perform : Cleaning of the Cargo Compartment Duct Temperature Sensors and the
Cargo Compartment-Temperature Sensor

Facebook Comments Box


0 comments

Add a comment...

Facebook Comments Plugin

 Check Starter Duct Rod NEO HP Compressor Airflow Control System 

Leave a Reply

Enter your comment here...

https://airbus.work/ata21/cargo-compartment-heating/ 9/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

Search … Search

Recent Posts

Engine Operation Limits, Guidelines and Special Procedures-CEO ENGINE


(https://airbus.work/engine/engine-operation-limits-guidelines-and-special-
procedures-ceo-engine/)

Aft Cargo Compartment Ventilation (https://airbus.work/ata21/__trashed/)

Pack Flow Control Valve (https://airbus.work/ata21/pack-flow-control-valve/)

 Inert Gas System A321 (https://airbus.work/ata47/inert-gas-system-a321/)

Power Transfer Of Hydraulic System A321 (https://airbus.work/ata29/power-transfer-of-


hydraulic-system-a321/)

Recent Comments

Archives

May 2023 (https://airbus.work/2023/05/)

February 2023 (https://airbus.work/2023/02/)

May 2022 (https://airbus.work/2022/05/)

April 2022 (https://airbus.work/2022/04/)

June 2021 (https://airbus.work/2021/06/)

April 2021 (https://airbus.work/2021/04/)

March 2021 (https://airbus.work/2021/03/)

January 2021 (https://airbus.work/2021/01/)

December 2020 (https://airbus.work/2020/12/) 

https://airbus.work/ata21/cargo-compartment-heating/ 10/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

November 2020 (https://airbus.work/2020/11/)

October 2020 (https://airbus.work/2020/10/)

July 2020 (https://airbus.work/2020/07/)

June 2020 (https://airbus.work/2020/06/)

May 2020 (https://airbus.work/2020/05/)

Categories

ATA21 (https://airbus.work/category/ata21/)

ATA27 (https://airbus.work/category/ata27/)

ATA28 (https://airbus.work/category/ata28/)

ATA29 (https://airbus.work/category/ata29/)

ATA30 (https://airbus.work/category/ata30/)

ATA32 (https://airbus.work/category/ata32/)

ATA33 (https://airbus.work/category/ata33/)

ATA36 (https://airbus.work/category/ata36/)

ATA47 (https://airbus.work/category/ata47/)

ATA49 (https://airbus.work/category/ata49/)

Engine (https://airbus.work/category/engine/)

IAE (https://airbus.work/category/engine/iae/)

Maintenance Tasks (https://airbus.work/category/maintenance-tasks/)

PRACTICAL EXPERIENCES (https://airbus.work/category/practical-experiences/)

PW (https://airbus.work/category/engine/pw/)

https://airbus.work/ata21/cargo-compartment-heating/ 11/12
8/19/23, 8:16 PM Cargo Compartment Heating – My Experience

Meta

Register (https://airbus.work/wp-login.php?action=register)

Log in (https://airbus.work/wp-login.php)

Entries feed (https://airbus.work/feed/)

Comments feed (https://airbus.work/comments/feed/)

WordPress.org (https://wordpress.org/)

My Experience (https://airbus.work/)
 (mailto:)

© Copyrights 2023, My Experience


A theme by MintTM (https://www.minttm.com/)

Proudly powered by WordPress (https://wordpress.org/)

https://airbus.work/ata21/cargo-compartment-heating/ 12/12

You might also like