CLASSIFICATION OF SYSTEMS
TR
IS

ACCORDING TO ISO 12944:2018


D
X
LE
IP
IM
H
C

ZINGAMETALL BV - SRL
Industriepark T. +32 9 385 68 81
Rozenstraat 4 info@zinga.be
9810 Eke (Belgium) www.zinga.eu

v1.7 - 20/10/2021
CLASSIFICATION OF ENVIRONMENT

THE CORROSIVE ENVIRONMENT


Urban and industrial atmospheres, moderate sulphur dioxide pollution.
C3 Coastal areas with low salinity.

C4 lndustrial areas and coastal areas with moderate salinity.

lndustrial areas with high humidity and aggressive atmosphere and coastal areas
C5 with high salinity.

F
Offshore areas with high salinity and industrial areas with extreme humidity and
CX

SI
aggressive atmosphere and subtropical and tropical atmospheres.

LU
lm1

C
River installations, hydro-electric power plants.

lm2 EX
lmmersed structures without cathodic protection (e.g. Harbour areas with
R
structures like sluice gates, locks, jetties; offshore structures).
U
TE

lm3 Buried tanks, steel piles, steel pipes.


U
IB

lmmersed structures with cathodic protection (e.g. Harbour areas with


lm4
TR

structures like sluice gates, locks, jetties; offshore structures).


IS
D
X
LE
IP
IM

CLASSIFICATION OF DURABILITY
H
C

THE REQUIRED LIFETIME

Low up to 7 years

Medium 7 to 15 years

High 15 to 25 years

Very High More than 25 years


SYSTEMS IN A C3 ENVIRONMENT

COAT 1 COAT 2 COAT 3 DURABILITY

DFT DFT DFT Very


Product Product Product Low Medium High
(μm) (μm) (μm) High

ZINGA® 60    
ZINGA® 60 Zingaceram PU 80    
Zingalu 60    

F
SI
Aquazinga 60    

LU
Tested by external laboratoria - Tested internally by Zingametall

C
EX
R
U
TE

SYSTEMS IN A C4 ENVIRONMENT
U
IB
TR
IS

COAT 1 COAT 2 COAT 3 DURABILITY


D
X

DFT DFT DFT Very


LE

Product Product Product Low Medium High


(μm) (μm) (μm) High
IP

ZINGA® 90    
IM

   
H

ZINGA® 60 Alu ZM 30
C

ZINGA® 60 Zingaceram PU 80   
ZINGA® 60 Zingalufer 80    
ZINGA® 60 Zingaceram HS 120    
ZINGA® 60 Zingaceram HS 40 Zingaceram PU 60    
Aquazinga 75    
Zingalu 110    
Tested by external laboratoria - Tested internally by Zingametall
SYSTEMS IN A C5 ENVIRONMENT

COAT 1 COAT 2 COAT 3 DURABILITY

DFT DFT DFT Very


Product Product Product Low Medium High
(μm) (μm) (μm) High

ZINGA® 90   
ZINGA® 120    
ZINGA® 60 Alu ZM 30   

F
ZINGA® 60 Zingalufer 80   

SI
LU
ZINGA® 60 Zingaceram HS 120   

C
EX
ZINGA® 60 Zingaceram HS 40 Zingaceram PU
R 60   
ZINGA® 60 Zingaceram HS 80 Zingaceram PU 60    
U
TE

Zingalu 110   
U
IB

Aquazinga 75   
TR

Aquazinga 60 Zingaceram HS 120    


IS
D

Aquazinga 60 Zingalufer 80    
X
LE

Tested by external laboratoria - Tested internally by Zingametall


IP
IM
H
C
SYSTEMS IN A CX ENVIRONMENT

COAT 1 COAT 2 COAT 3 DURABILITY

DFT DFT DFT Very


Product Product Product Low Medium High
(μm) (μm) (μm) High

ZINGA® 120

ZINGA® 60 Zingalufer 100 Not Applicable

ZINGA® 60 Zingaceram 120 Zingaceram PU 60

F
Tested by external laboratoria - Tested internally by Zingametall

SI
LU
C
SYSTEMS IN IMMERSION
EX
R
U
ENVIRON-
COAT 1 COAT 2 COAT 3 DURABILITY
TE

MENT
U

DFT DFT DFT Very


Product Product Product Low Medium High
(μm) (μm) (μm) High
IB
TR

ZINGA® 120 lm2/3  


IS

ZINGA® 120 lm4 Not Applicable


D
X

ZINGA® 60 Zingatarfree 90 Zingatarfree 90 lm2/3    


LE
IP

Tested by external laboratoria - Tested internally by Zingametall