You are on page 1of 18

BUILDING MAINTENANCE DIVISION

CONCRETING

 Strength per Class Mixture

REINFORCEMENTS

 Commercial Bar Diameter and Length Sizes


FOOTINGS

REFERENCE: FAJARDO & MSTCONNECT

 CONCRETE WORKS (VOLUME)

*Conc
r ete

spacer – 1:4 (Cement, Sand) ratio, 1000 psi

 METAL WORKS
o REINFORCEMENTS (PCS)
L∨W
 ¿ OF CUT LENGTH = +1
SPACING

TOTAL CUT LENGTH


 ¿ OF BARS = (ROUND UP)
COMMERCIAL LENGTH

o GI TIE WIRE #16 (KG)


2
D
 KG PER METER LENGTH =
162.2
 GI TIE WIRE ¿ 16 (KG)=(TOTAL MASS OF REINFORCEMENT )( 2% )
Note: The 2% factor depends on the estimator

(¿ OF TOTAL JOINTS)(0.30 M LENGTH OF TIES)


 GI TIE WIRE ¿ 16 (KG)=
53
Note: Usual length of ties per joint is 30 cm and 1 kg of GI TIE WIRE #16 = 53 meters

REFERENCE: DPWH-DUPA

 CONCRETE WORKS (VOLUME)


 METAL WORKS

COLUMNS

REFERENCE: FAJARDO & MSTCONNECT

 CONCRETE WORKS (VOLUME)


 METAL WORKS
o REINFORCEMENTS (PCS)
 LONGITUDINAL REINFORCEMENT: REFER TO REBAR CUTTING LIST
 LATERAL TIES: REFER TO NSCP FOR MIN. INSIDE BEND DIAMETERS &
STANDARD HOOKS
 LATERAL TIES ( CUT LENGTH )=P stirrups+ L Hook – L BEND

COMMERCIAL LENGTH
 ¿ OF BARS = ( ROUND UP)
LATERAL TIES(CUT LENGTH )

o GI TIE WIRE #16 (KG)


2
D
 KG PER METER LENGTH =
162.2
 GI TIE WIRE ¿ 16 (KG)=(TOTAL MASS OF REINFORCEMENT )( 2% )
Note: The 2% factor depends on the estimator

(¿ OF TOTAL JOINTS)(0.30 M LENGTH OF TIES)


 GI TIE WIRE ¿ 16 (KG)=
53
Note: Usual length of ties per joint is 30 cm and 1 kg of GI TIE WIRE #16 = 53 meters
REFERENCE: DPWH-DUPA

 CONCRETE WORKS (VOLUME) – same with footing


 METAL WORKS – same with footing

BEAMS, TIE BEAMS, ROOF BEAMS

REFERENCE: FAJARDO & MSTCONNECT

 CONCRETE WORKS (VOLUME)


 METAL WORKS
o REINFORCEMENTS (PCS)
 LONGITUDINAL REINFORCEMENT: REFER TO REBAR CUTTING LIST
 STIRRUPS: REFER TO NSCP FOR MIN. INSIDE BEND DIAMETERS &
STANDARD HOOKS
 STIRRUPS ( CUT LENGTH )=Pstirrups + L Hook – L BEND

COMMERCIAL LENGTH
 ¿ OF BARS = ( ROUND UP)
STIRRUPS(CUT LENGTH )

o GI TIE WIRE #16 (KG)


2
D
 KG PER METER LENGTH =
162.2
 GI TIE WIRE ¿ 16 (KG)=(TOTAL MASS OF REINFORCEMENT )( 2% )
Note: The 2% factor depends on the estimator

(¿ OF TOTAL JOINTS)(0.30 M LENGTH OF TIES)


 GI TIE WIRE ¿ 16 (KG)=
53
Note: Usual length of ties per joint is 30 cm and 1 kg of GI TIE WIRE #16 = 53 meters

REFERENCE: DPWH-DUPA

 CONCRETE WORKS (VOLUME) – same with footing


 METAL WORKS – same with footing
SLABS

REFERENCE: FAJARDO & MSTCONNECT

 CONCRETE WORKS (VOLUME)


 METAL WORKS
o REINFORCEMENTS (PCS)
 BOTTOM BARS, TOP MAIN BARS:
L∨W
 ¿ OF CUT LENGTH = +1
SPACING
TOTAL CUT LENGTH
 ¿ OF BARS = (ROUND UP)
COMMERCIAL LENGTH

o GI TIE WIRE #16 (KG)


D2
 KG PER METER LENGTH =
162.2
 GI TIE WIRE ¿ 16 (KG)=(TOTAL MASS OF REINFORCEMENT )( 2% )
Note: The 2% factor depends on the estimator

(¿ OF TOTAL JOINTS)(0.30 M LENGTH OF TIES)


 GI TIE WIRE ¿ 16 (KG)=
53
Note: Usual length of ties per joint is 30 cm and 1 kg of GI TIE WIRE #16 = 53 meters

REFERENCE: DPWH-DUPA

 CONCRETE WORKS (VOLUME) – same with footing


 METAL WORKS – same with footing
MASONRY WORKS

REFERENCE: FAJARDO & MSTCONNECT, BMD

 CHB (PCS)

Note: 4” x 8” x 16” = 100 mm x 200 mm x 400 mm, 6” x 8” x 16” = 150 mm x 200 mm x 400 mm

A WALL∗12.5 PCS OF CHB


o CHB= 2
1m

 MORTAR (CEMENT, SAND)


o 4 CHB: {1 BAG OF CEMENT} over {25 PCS OF CHB

o 6 CHB: {1 BAG OF CEMENT} over {30 PCS OF CHB

1 BAG OF CEMENT
o SAND :
6 F T 3 OF SAND

 PLASTERING (CEMENT, SAND)


1 BAG OF CEMENT
o CEMENT :
2 m2 AREA COVERED

1 BAG OF CEMENT
o SAND :
3 FT 3 OF SAND

 METAL WORKS
o REINFORCEMENTS (PCS) – FAJARDO

o REINFORCEMENTS (PCS) –
TAGAYUN
 HORIZONTAL BARS
h net wall
 n= ( ROUND UP)
spacing

 L¯¿=(n)(L overall wall )¿

L¯¿ ( 1.10)
 ¿ OF BARS = (ROUND UP) ¿
COMMERCIAL LENGTH

 VERTICAL BARS
Lnet wall
 n= ( ROUND UP)
spacing

 L¯¿=(n)(h overall wall )¿

L¯¿ ( 1.2 0)
 ¿ OF BARS = (ROUND UP) ¿
COMMERCIAL LENGTH

o GI TIE WIRE #16 (KG)


D2
 KG PER METER LENGTH =
162.2
 GI TIE WIRE ¿ 16 (KG)=(TOTAL MASS OF REINFORCEMENT )( 2% )
Note: The 2% factor depends on the estimator


(¿ OF TOTAL JOINTS)(0.30 M LENGTH OF TIES)
GI TIE WIRE ¿ 16 (KG)=
53

REFERENCE: DPWH-DUPA
FORMWORKS, FALSEWORKS

REFERENCE: FAJARDO, MSTCONNECT

 PLYWOOD & FRAME FOR COLUMNS AND PLYWOOD & FORM FOR BEAMS AND
GIRDER
 HORIZONTAL, VERTICAL AND DIAGONAL BRACINGS FOR COLUMN, BEAM &
FLOORING
REFERENCE: DPWH-DUPA
ROOFING WORKS

REFERENCE: FAJARDO, MSTCONNECT

 G.I. ROOF SHEET (PCS)


o CHECK FOR SIZE OF SIDE LAPPING AND END LAPPING
LGUTTER
o ¿ OF SHEETS=
weff

o CHECK THE LENGTH OF RAFTER, THE LENGTH OF RAFTER WOULD BE THE


BASIS FOR THE COMBINATION OF NUMBER OF SHEETS TO BE ORDERED

o RIVETS/UMBRELLA NAILS (PCS)


 TABLE 6-2 (FOR PCS/SHEET), TABLE 6-3 (FOR PCS/KG)
o LEAD WASHERS
 SAME QUANTITY TO RIVETS, TABLE 6-3 (FOR PCS/KG)
o G.I. WASHER (PCS)
 DOUBLE THE QUANTITY OF RIVETS, TABLE 6-3 (FOR PCS/KG)
o PLAIN G.I. ANCHOR STRAP (PCS)
 SAME QUANTITY TO RIVETS, REFER TO TABLE 6-4 TO DETERMINE THE
NUMBER OF PLAIN GI SHEET TO PRODUCE THE STRAP
o COMMON WIRE NAIL
 3 NAILS PER STRAP (FOR 4d, 32 mm C.W. NAIL, 1 KG = 695 PCS)

 GUTTER, FLASHING, RIDGE, HIPPED & VALLEY ROLL


o GUTTER
 LGUTTER =Perimeter∨Length Covered by the roof gutter

LGUTTER
 ¿ OF GUTTER= Note: 2.35 is the effective length of gutter
2.35

 Determine the total width of gutter depending on the “perimeter” of its cross-section.

COMMERCIAL GUTTER WIDTH =90 CM


 ¿ OF GI GUTTER=
WIDTH OF GUTTER=PERIMETER

¿ OF GUTTER
 ¿ OF GI SHEET =
¿ OF GI GUTTER

o FLASHING
 LFLASHING =Perimeter∨Length Covered by the flashing (back ∨front part )

L FLASHING
 ¿ OF FLASHING= Note: 2.30 is the effective length of flashing
2.3 0

 Determine the total width of flashing depending on the “perimeter” of its cross-
section.

COMMERCIAL GUTTER WIDTH=90 CM


 ¿ OF GI FLASHING=
WIDTH OF FLASHING=PERIMETER

¿ OF FLASHING
 ¿ OF GI SHEET =
¿ OF GI FLASHING

o RIDGE ROLL, VALLEY AND HIPPED ROLL


 LRIDGE =Perimeter∨Length Covered by the ridge roll(back ∨front part )

LFLASHING
 ¿ OF RIDGE ROLL= Note: 2.20 is the effective length of ridge roll
2.20

 Determine the total width of ridge roll depending on the “perimeter” of its cross-
section.
COMMERCIAL GUTTER WIDTH =90 CM
 ¿ OF GI RIDGE ROLL=
WIDTH OF RIDGE=PERIMETER

¿ OF RIDGE ROLL
 ¿ OF GI SHEET =
¿ OF GI RIDGE ROLL

STEEL ROOF FRAMING


o STEEL TUBULAR
 COUNT THE STEEL TUBULAR FOR RAFTER
o C-PURLINS
o GUTTER

REFERENCE: DPWH-DUPA