A[44]01cTypical elevation
CL Scale 1:10
180
50mm dia upright rail/ balusters
out of 4mm thick stainless steel
180
sleeve encasement on 32mm
. dia x 2mm thick corrosion
resistant steel core.
1,000
980
180
50 dia mild steel tube 15mm dia stainless steel tube
handrail to architects approval.
.
180
welded to 5mm ms double plate
to Aarchitect's approval
C
L
150
5mm thick ms double plate
welded to 5mm thick ms plate
10
.
20 20
DISCLAIMER:
20
20
A[44]01d Plan - Typical baluster joint
Scale 1:5
.
A[44]02 c Typical elevation CL
Scale 1:10
DISCLAIMER:
to Architect's approval
.
Paint to cement plaster
5mm thick ms double plate Rc tread
welded to 5mm thick ms plate
12
Staircase soffit to
finishes schedule
A[44]02d Plan - Typical baluster joint A[44]02b Mild steel Hand rail section
Scale 1:5
Scale 1:10
A[44]02a Mild Steel Handrail detail
Scale 1:10
A(44)02-Steel Railing detail
1
1 : 10
NOTES Revisions: Client: Project Title:
rev date description Architect: Drawn: Checked:
1. This drawing is copyright. 7. Walls below 200mm thick to be reinforced with hoop iron at every alternate course. ENTERPRISE UGANDA LIMITED PROPOSED OFFICE BUILDING
JULIUS DDAMULIRA C.G.O R.R
2. Do not scale off this drawing. 8. Depth of foundations to be decided on site.
3. All levels and dimensions to be checked on site before any Reg. No. 196 Date: Scale:
9. pv denotes permanent air vents over doors and windows as shown on drawings. Drawing Title:
building work commences. Location: Prac.No. 3101 MARCH 2020
11. Drain pipes passing under tarmac, driveways, and buildings to be encased in 150mm Steel Railing detail
4. Any discrepancies to be reported to the office of the consultant. thick concrete surround. PLOT 2A,&2-4,BUTABIKA ROAD,
BUTABIKA,KAMPALA DISTRICT Published: 9/9/2021 12:07:02 1 : 10 @ A3
5. All work to be strictly in accordance to with the standard specifications and notes. 12. All reinforced concrete work to Structural Engineer's drawings.
6. This drawing is to be read in conjunction with specifications and all other relevant 13. All sanitary works to the entire satisfaction of MoH.
Job no. Drawing no.
TEL:+256 701-650587 A(44)02
drawings. 14. All roads, storm water drainage and foul sewerage to Civil Engineer's drawings.
Clear silicone
Rubber in Handrail
50 dia stainless steel tube
handrail to Architect's appoval Handrail
Silicone
950
Clear silicone
10mm tempered
glass Silicone
150
150mm high concrete upstand
Washer Aluminium Channel
cement screed
Rubber for glass
Finish Floor Level Rc tread
Counter sunk screw
A[44]03e Plan - Typical channel installation A[44]03a Frameless Glass Railing detail DISCLAIMER:
Scale 1:10 This drawing is only illustrative,
Scale 1:5
The concrator should provide shop drawings before fabrication.
A(44)03-Glass Railing detail All component and assembly samples to Architect's approval
1
1 : 10
NOTES Revisions: Client: Project Title:
rev date description Architect: Drawn: Checked:
1. This drawing is copyright. 7. Walls below 200mm thick to be reinforced with hoop iron at every alternate course. ENTERPRISE UGANDA LIMITED PROPOSED OFFICE BUILDING
JULIUS DDAMULIRA C.G.O R.R
2. Do not scale off this drawing. 8. Depth of foundations to be decided on site.
3. All levels and dimensions to be checked on site before any Reg. No. 196 Date: Scale:
9. pv denotes permanent air vents over doors and windows as shown on drawings. Drawing Title:
building work commences. Location: Prac.No. 3101 MARCH 2020
11. Drain pipes passing under tarmac, driveways, and buildings to be encased in 150mm Glass Railing detail
4. Any discrepancies to be reported to the office of the consultant. thick concrete surround. PLOT 2A,&2-4,BUTABIKA ROAD,
BUTABIKA,KAMPALA DISTRICT Published: 9/9/2021 12:07:08 As indicated @ A3
5. All work to be strictly in accordance to with the standard specifications and notes. 12. All reinforced concrete work to Structural Engineer's drawings.
6. This drawing is to be read in conjunction with specifications and all other relevant 13. All sanitary works to the entire satisfaction of MoH.
Job no. Drawing no.
TEL:+256 701-650587 A(44)03
drawings. 14. All roads, storm water drainage and foul sewerage to Civil Engineer's drawings.
Line of wall finish to finishes
schedules
42
43 21
50 dia stainless steel tube
handrail to architects approval. 50 dia mild steel tube
handrail to architects approval.
50
81° 30
77
90°
R 47
100
30
65mm dia ss plate with 4 no.5mm
35
dia screw holes & screws with
70
35
welded with angle
brackets
68
68
70mm dia ms plate with 3 no.5mm dia
screw holes & screws.
75