You are on page 1of 1

NOTES: NOTES:

OXYGEN
SCAVENGER 869-U-1009 6. CHEMICAL INJECTION TO BE ONLY TO ONE PLACE AT A TIME. A. FOR STANDARD SYMBOLS/ LEGEND AND TYPICAL DETAIL
DEMAND ADDITIVES MUST BE LINED UP INDIVIDUALLY TO A SINGLE ITEM OF
X BFW CHEMICAL DOSING PACKAGE (OXYGEN SCAVENGER) SEE DRAWINGS TA-249760-001 TO TA-249762-005.
RATIO EQUIPMENT SO THAT THE INJECTION AND QUANTITY TO THAT
FLOW SIGNAL DUTY: 2.7 HP
FY NOTE 2, 4, 5, 7, 18 EQUIPMENT CAN BE CONFIRMED. B. THE SRU FEATURES 3 TRAINS. THIS DRAWING IS FOR TRAIN 1
738 TA-249811-011 C 7. CHEMICAL INJECTION PACKAGE WHICH IS NOT ENCLOSED WITHIN
3400 C ONLY. THE CORRESPONDING TRAIN 2 & 3 CONFIGURATION IS
FROM BFW FLOW C A BUILDING SHALL BE PROVIDED WITH A SHELTER TO MINIMISE THE IDENTICAL WITH THE EXCEPTION THAT THE FIRST DIGIT IN
FC-1070
DUTY/STANDBY DUTY/STANDBY INGRESS OF STORMWATER. (TD-071006 PARA.11.2) THE SEQUENCE NUMBER "1XXX" IS REPLACED WITH "2XXX" OR
OXYGEN HS SELECTOR HS SELECTOR 8. BUND MATERIAL TO BE SUITABLE FOR ALL CHEMICALS. "3XXX" IN THE EQUIPMENT TAG. ALL INSTRUMENT TAG NUMBERS
SCAVENGER 3401 3402 9. DRAINAGE CONNECTION SHALL BE PROVIDED AS PER WASTE WATER ON THIS P&ID SHALL BE PREFIXED WITH '869-100-' (UNLESS
DEMAND DRAINAGE PHILOSOPHY BASED ON THE TYPE OF CHEMICALS USED. OTHERWISE NOTED). TRAIN 2 INSTRUMENT TAG NUMBERS
RATIO X
PACKAGE SUPPLIER SHALL COMBINE THE DRAIN CONNECTIONS FROM SHALL BE PREFIXED WITH '869-200-' AND HAVE SEQUENCE
FLOW SIGNAL
FY C INDIVIDUAL CHEMICALS AS FAR AS POSSIBLE AND ROUTE MINIMUM NO. NUMBERS FROM 1001 ONWARDS. TRAIN 3 INSTRUMENT TAG
983 TA-249813-002 OF DRAIN CONNECTIONS AT THE SKID B/L. (TD-071006 PARA.11.2)
3401 DUTY/STANDBY C NUMBERS SHALL BE PREFIXED WITH '869-300-' AND HAVE
FROM BFW FLOW NOTE 14 10. 2 X 100% (DUTY / STANDBY) PHOSPHATE INJECTION PUMPS (MULTI-HEAD). SEQUENCE NUMBERS FROM 1001 ONWARDS. ZC TAGS SHALL
HS SELECTOR
FC-1321
C NOTE 17 NOTE 17 NOTE 17 NOTE 17 NOTE 17 11. MOTOR DRIVEN MIXER FOR PHOSPHATE SERVICE. HAVE SEQUENCE NUMBERS FROM 001 ONWARDS, THAT REMAIN
3400 12. AIR DRIVEN PUMP.
PI H PI H PI H PI H PI H THE SAME IN EACH TRAIN.
13. MULTI-HEAD PUMP.
3409 3407 3405 3403 3401 14. PUMP STROKE WILL BE ADJUSTABLE TO ALLOW FLOW CONTROL. 1. DISTRIBUTION AND MANIFOLDS TO BE CONFIRMED LATER.
THIS WILL BE AUTOMATIC.
H H H H H NOTE 17 NOTE 17 NOTE 17 NOTE 17 NOTE 17 NOTE 14 NOTE 14 NOTE 14 NOTE 14 NOTE 14 H 15. BUND FOR 869-U-1009 CONTINUES TO DWG TA-249813-021. C 2. TYPE AND NUMBER OF BOILER FEED WATER DOSING CHEMICALS
FI PI FI PI FI PI FI PI FI PI LI C
PI
H
PI
H
PI
H
PI
H
PI
H
HIC HIC HIC HIC HIC HIC HIC HIC HIC HIC
16, NON-SLAM INTERNAL SPRING ASSISTED TYPE CHECK VALVE. TO BE CONFIRMED WITH VENDOR.
3404 3414 3403 3413 3402 3412 3401 3411 3400 3410 3400 17. DIAPHRAGM FAILURE SIGNAL.
L L L L L L L L L L 3408 3406 3404 3402 3400 C 3401 C 3405 3402 3406 3403 3407 3404 3408 3400 3409 L
18. CHEMICAL INJECTION PACAKGE INCLUDES OXYGEN SCAVENGER AND 3. MULTI-POINT INJECTION PUMP.
C C C C C C C C C C C PHOSPHATE.
CONTRACTOR 4. BFW DOSING PACKAGE SHOWN IS TYPICAL. VENDOR TO SUPPLY
VENDOR VENDOR PACKAGE ACTUAL.

5. P&ID TO BE UPDATED TO REFLECT / CONVERT VENDOR'S


DRAWINGS. IF ADDITIONAL DRAWINGS ARE NEEDED, THIS P&ID
PZV
+ MUST BE UPDATED TO REFERENCE NEW DRAWINGS.
3400 FP/CSO FREE DRAINING

FF C
FF DETAIL 8
FIT PIT PZV
2"-C-1008-6SD0U01 3400 3410
C +

3401 869-U-1009
FP/CSO FREE DRAINING
INST. NOTE 2, 3, 4, 5 LEGEND
FE C FP/CSO TO SAFE CHEMICAL TRANSFER PUMP
BFW DOSING +
PIPING C PIPING MATERIAL
3400 LOCATION (AIR OPERATED) INSTRUMENT DEFINITION & SYMBOLS SAES-J-003
CHEMICAL C PZV NOTE 6 SPECIFICATION SAES-L-105
LIT AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT

FREE DRAINING
+

NO POCKETS
TA-249811-011 20125 3402 FP/CSO FREE DRAINING (BULK CONTRAINER)
AIR FAILURE OPEN VS -VIBRATION SWITCH
3400 PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
TO SRU WHB STEAM
FF
FP/CSO
C M C UNLOADING
INSTRUMENT FAILURE STEADY XL -PILOT LIGHT
DRUM 869-D-1009 FF 1" D 1" D AIR LINE AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)
FIT PIT C PZV AIR FAILURE CLOSE LS -LIMIT SWITCH
NOTE 12 ELECTRIC SIGNAL

FREE DRAINING
+
ZC -SHUTDOWN LOGIC

NO POCKETS
AO/AFS -AIR TO OPEN/AIR
2"-C-1014-6SD0U01 3401 3411 3403 FP/CSO FREE DRAINING CAPILLARY TUBING FAILURE STEADY ZV -SAFETY SHUTDOWN VALVE
FE INST. 1" ZBV -EMERGENCY BLOWDOWN VALVE
+
C FP/CSO SOFTWARE LINK AOV -ON-OFF VALVE
BFW DOSING 3401 PIPING C WIRELESS SIGNAL AT -ANALYZER TRANSMITTER
D DATA LOGGER POINT
CHEMICAL C PZV ESD -EMER. SHUTDOWN SYSTEM
NOTE 16

HYDRAULIC SIGNAL F-FLOW P-PRESS.

INPUTS
FREE DRAINING

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL, OR IN PART, SHALL BE OBTAINED FROM THIS DRAWING WITHOUT THE WRITTEN CONSENT OF SAUDI ARAMCO.
+
FC - FLOW CONTROLLER

NO POCKETS
TA-249813-002 20349 3404 FP/CSO FICV - FLOW INDICATING REGULATOR
L-LEVEL T-TEMP.
PIPING MATERIAL CLASS X-MISC. A-ALARM
TO THERMAL FP/CSO BREAK FV -FLOW CONTROL VALVE
LOCAL PANEL
OXIDATION PACKAGE C FCV -FLOW CONTROL VALVE MOUNTED INSTR.
FF FREE DRAINING FF FF DETAIL 7 INSULATION BREAK
869-U-1002 FF PIT PIT HOLDS:
(SELF-ACTUATED)
FIT PIT

FREE DRAINING
AG UG ABOVE GROUND / FE -FLOW ELEMENT

NO POCKETS
CONSOLE MOUNTED
C 3403 3401 UNDERGROUND BREAK FG -FLOW SIGHT GLASS INSTRUMENT
2"-C-1013-1SD0U01 3402 3412 1" LG 1. 869-U-1009 PACKAGE DETAIL DESIGN. FHV -FLOW MANUAL CONT. VALVE
FE INST. FP/CSO MAX DESIGN PRESSURE R/G
FM -FLOW METER
3402
+
C PIPING D FF FF FF 3401 AND TEMPERATURE XL STATUS LIGHTS
BFW DOSING FO -RESTRICTION ORIFICE R=RED, G=GREEN
PIT PIT PIT BREAK
NOTE 16

CHEMICAL C FQI -FLOW TOTALIZER INDICATOR

FREE DRAINING
PILOT LIGHT (DO NOT
TG C MAX OPERATING PRESSURE

NO POCKETS
3404 3402 3400 AND TEMPERATURE
FR -FLOW RECORDER USE FOR MOTOR STATUS)
TA-249811-012 20133 PG
C PULSATION M C
PDI 3400 BREAK
FIT -FLOW TRANSMITTER
MOTOR STATUS
TO FIRST SULFUR 3400 DAMPER FY -FLOW RELAY ML
PILOT LIGHT
INST. 3400 C NOTE 11 SUPPLY
CONDENSER INST. RESPONSIBILITY
GWR -GUIDED WAVE RADAR
869-E-1003 FF FF HC -HAND CONTROLLER
PIPING BREAK LOCAL MOUNTED
FIT PIT PIPING HS -HAND SWITCH INSTRUMENT
C
2"-C-1052-1SD0U01 NOTE 1 3403 3413 1"
END OF LINE LA -LEVEL ALARM
-LEVEL CONTROL VALVE
FE INST. LV MOUNTED BEHIND
+
C PIPING D
LCV -LEVEL CONTROL VALVE LOCAL PANEL
BFW DOSING 3403 PG PULSATION REDUCER (SELF-ACTUATED)
C PDI
NOTE 16

CHEMICAL C 3401 DAMPER NOTE 10, 13 C LG -LEVEL GAUGE RACK MOUNTED


INST. 3401 RING SPACER LC -LEVEL CONTROLLER (OR BACK OF PANEL)
TA-249811-015 20261 INST. LI -LEVEL INDICATOR
PIPING
TO SECOND SULFUR PIPING LR -LEVEL RECORDER INSTRUMENT
CONDENSER BLIND-CLOSED LS -LEVEL SWITCH AIR SUPPLY REQUIRED

869-E-1004 LIT -LEVEL TRANSMITTER


GATE VALVE ML -MOTOR STATUS LIGHT ELECTRICAL
PG PULSATION MOV -MOTOR OPERATED VALVE SUPPLY REQUIRED
1" C C PDI GLOBE VALVE
3402 DAMPER NOTE 10, 13 2" NCR -NON-CONTACT RADAR
H
FF FF INST. 3402 CHECK VALVE PB -PUSHBUTTON HIGH LOW
D INST.
C FIT PIT PIPING PC -PRESSURE CONTROLLER L
C
NOTE 16

PLUG VALVE
PIPING PV -PRESS. CONTROL VALVE
2"-C-1053-1SD0U01 3404 3414 BALL VALVE PCV -PRESS. CONTROL VALVE
FF
FE INST. (SELF ACTUATED)
FOUNDATION
FIELDBUS INSTRUMENT
+
C PIPING
BFW DOSING 3404 DOUBLE DISC PDC -PRESS. DIFF. CONTROLLER
PG C PULSATION GATE VALVE PDI -PRESS. DIFF. INDICATOR
CHEMICAL PDI
NNF 3403 DAMPER NOTE 10, 13 C ANGLE VALVE
PDIS -PRESSURE DIFFERENTIAL
INDICATOR SWITCH
TA-249811-018 20292 INST. 3403
INST. PDIT -PRESS. DIFF. TRANSMITTER
DISTRIBUTED CONTROL/SHARED
TO THIRD SULFUR PIPING PRESS RELIEF PG -PRESSURE GAGE
CONDENSER PIPING VALVE PI -PRESSURE INDICATOR
DISPLAY SYMBOLS

869-E-1005 PR -PRESSURE RECORDER (DCS) DISTRIBUTED CONTROL


VACUUM RELIEF PS -PRESSURE SWITCH SYSTEM, OPERATOR ACCESSIBLE
PIT -PRESSURE TRANSMITTER IN CONTROL ROOM
PG VALVE
1" C PULSATION C PDI PP -PRESSURE POINT (DCS) DISTRIBUTED CONTROL
3404 DAMPER NOTE 10, 13 M MOTOR OPERATED PY -PRESS. COMPUTATION MOD. SYSTEM, OPERATOR INACCESSIBLE
D INST. 3404 VALVE IN CONTROL ROOM
PZE -RUPTURE DISK
INST.
NOTE 16

PIPING PISTON OPERATED


PZV -PRESSURE RELIEF VALVE
(DCS) DISTRIBUTED CONTROL
PIPING VALVE
RTD -RESIST. TEMP. DETECTOR SYSTEM, OPERATOR ACCESSIBLE
SC -SPEED CONTROLLER IN FIELD
H SI -SPEED INDICATOR
HYDRAULIC OPERATED LOCAL DCS OR AUXILIARY
SE -SPEED ELEMENT
VALVE DCS LOCATION NORMALLY
SSV -SURFACE SAFETY VALVE
PZV ACCESSIBLE TO OPERATOR
CONTROL VALVE SSSV -SUB-SURFACE SAFETY VALVE
NOTE 10, 13
+

3405 FP/CSO FREE DRAINING ST -SPEED TRANSMITTER


BALL TYPE TC -TEMP. CONTROLLER PROGRAMMABLE LOGIC
C CONTROL VALVE TV -TEMP. CONTROL VALVE CONTROLLER WITH BINARY
WITH POSITIONER
PZV TCV -TEMP. CONTROL VALVE OR SEQUENTIAL FUNCTIONS
+
S (SELF-ACTUATED)
3406 FP/CSO FREE DRAINING
SOLENOID VALVE TE -TEMP. ELEMENT
(PLC) PROGRAMMABLE LOGIC
CONTROLLER, NORMALLY
TG -TEMPERATURE GAUGE
FP/CSO INACCESSIBLE OR BEHIND THE
C VALVE NORMALLY TI -TEMP. INDICATOR PANEL DEVICE OR FUNCTIONS
CLOSED TS -TEMP. SWITCH
PZV TKV -TUBING KILL VALVE
(PLC) PROGRAMMABLE LOGIC
1" 1" 1" 1" 1" IBT - INVERTED BUCKET
FREE DRAINING

+ CONTROLLER FUNCTION,
NO POCKETS

3407 FP/CSO FREE DRAINING STEAM TRAP TIT -TEMP. TRANSMITTER CAN BE NORMALLY
D D D D D TSO -TIGHT SHUT OFF TW -THERMOWELL DISPLAYED ON CRT
FP/CSO UC -SEQUENCE / LOGIC CONTROL
C S.C. - SAMPLE CONN. (PLC) PROGRAMMABLE LOGIC
NOTE 16

NOTE 16

NOTE 16

NOTE 16

NOTE 16

S -DRAIN TO CONTROLLER I/O POINT


PZV NORMALLY INACCESSIBLE
PRESSURE SEWER
FREE DRAINING

+
NO POCKETS

3408 FP/CSO FREE DRAINING OWS -OILY WATER SEWER


BY OPERATOR

FP/CSO D -DRAIN
C V -VENT
PZV REFERENCE DRAWINGS
FREE DRAINING

+
NO POCKETS

3409 FP/CSO LETTER IDENTIFICATION OF LINES AD-036204


FP/CSO PIPING SYMBOLS AB-036227
C FF FF
FREE DRAINING PIT PIT DETAIL 7 EQUIPMENT SYMBOLS AB-036305
100-ZC-001
FREE DRAINING

3408 3406
NO POCKETS

INSTRUMENT SYMBOLS AC-036950


100-ZC-002
100-ZC-101 PIPING LAYOUT INDEX
FP/CSO
100-ZC-103 ZC FF FF FF PLOT PLAN
100-ZC-107 107 PIT PIT PIT
PROCESS FLOW DIAGRAM
FREE DRAINING

100-ZC-129 3409 3407 3405


NO POCKETS

100-ZC-133 C HYDROSTATIC TEST DIAGRAM


100-ZC-234
PG PULSATION M PDI DRAWING CONTROL FOR J.O.
3405 DAMPER
INST. 3405 INSTRUMENT INSTALLATION SCHEDULES
C INST.
PIPING
PIPING

C 04/29/22
PG PULSATION
PDI
3406 DAMPER NOTE 10, 13 C B 03/17/22
INST. 3406
C INST. A 01/24/22
PIPING
PIPING
REV DATE BY CH'D PROC PIPE INST MECH ELEC CIVIL SAFETY

REVISION VALIDATION
PG PULSATION C
PDI THIS REVISION NO. C IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
3407 DAMPER NOTE 10, 13
C INST. 3407 REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
INST.
PIPING 10-14329-0003-001
PIPING
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
PG PULSATION ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
PDI C SIH MWK
3408 DAMPER NOTE 10, 13 04/29/22 04/29/22
C INST. 3408
INST.
PIPING REV.NO. DATE REVISION DESCRIPTION
PIPING C 04/29/22 ISSUED FOR DESIGN

JOB ORDER NO.


THIS REVISION IS NOT TO BE USED FOR
PG PULSATION C 10-14329-0003
PDI NOTE 9 CONSTRUCTION UNTIL CERTIFIED AND DATED
3409 DAMPER NOTE 10, 13
C
INST.
PIPING
INST.
3409 C
SAUDI ARABIAN OIL COMPANY
PIPING DRAWING TYPE
PIPING & INSTRUMENTATION DIAGRAM PID

NOTE 10, 13 BFW CHEMICAL DOSING PKG. (O2 SCVNGR) - TRAIN 1


2"-OWS-10111-1CS2P01
JFGP SULFUR RECOVERY & TAIL GAS
NOTE 15
NOTE 8 JAFURAH SAUDI ARABIA
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

OWS 869 A TA-249813 022 C


AFW DOC NO: TA-249813-022 CLASS: 1 REV: C DSN: Saudi Aramco 5994 ENG. (02/07)