MECHANICAL DATA SHEET


REV
NO.
A

DISCIPLINE
ENGINEER FOR
COOLING WATER SYSTEMS CHEMICAL
SBK
DATE 18-FEB-22
ENGINEERING
MANAGER

DATE
JHK

18-FEB-22
INJECTION PACKAGE
CERTIFIED

MWK
(862-U-2302)
DATE 18-FEB-22
CONSTRUCTION
AGENCY

DATE
OPERATIONS

DATE
CONTROL NUMBER
VERIFICATION
EDSD

DATE:
BY:
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B______
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 1
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY


PMT
ENG'G CERT

MWK
HCK

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
SBK

SBK

CONTENTS

SECTION DESCRIPTION Page No.

1 Introduction 3
DESCRIPTION

2 Process Duty 4
3 Mechanical Design 6
4 Control, Safeguarding and Instrumentation 8
5
10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

Electrical 8
6 Utilities 8
7 Package Data 9-12
8 Dosing Pump 13-14
9 Dosing Pump Motor Data Sheet 15-16
JO/EWO

16-DEC-21

18-FEB-22
DATE
REV
NO.
A

DISCIPLINE
ENGINEER

SBK
DATE 18-FEB-22
ENGINEERING
MANAGER

JHK
DATE 18-FEB-22
CERTIFIED

MWK
DATE 18-FEB-22
CONSTRUCTION
AGENCY

DATE
OPERATIONS

DATE
CONTROL NUMBER
VERIFICATION
EDSD

DATE:
BY:
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B_____
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 2
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
1.0 INTRODUCTION
PMT

1.1 General
ENG'G CERT

This Data Sheet covers the requirements for the Chemical Injection Package (862-U-2302), for the
MWK
HCK

Jafurah Project, Cooling Water Systems (CWS).


Chemical Injection is required to prevent corrosion and inhibit biological fouling in the open loop Cooling Tower
SBK

SBK

Water circuit and the closed loop Cooling Water circuit. Six chemicals will be injected.
Five
5
The Package shall be designed and supplied as 6 complete skid-mounted units, one skid per chemical.

The CWS Chemical Injection package shall consist of, but not be limited to, the following:
5
- 6 x 100% chemical storage tanks (one for each chemical), sized for a minimum of 30 days supply of dosing
DESCRIPTION

volumes at the maximum dosing rate. Each tank to be fitted with necessary level & temperature instruments.
5
- 6 chemical transfer pumps for storage tank filling, one for each chemical.
- Tank mixer including driver fitted with each tank (if required) Deleted.
- 2 x 100% electrical dosing pumps for Corrosion Inhibitor to the closed loop Cooling Water (CW) circuit,
10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

One operation and One stand-by


- 2 x 100% electrical dosing pumps for Oxygen Scavenger to the CW circuit, One operation and One stand-by

- 2 x 100% electrical dosing pumps for Biocide to the open loop Cooling Tower Water (CTW) circuit, Deleted.
One operation and One stand-by
- 2 x 100% electrical dosing pumps for Sodium Hypochlorite to the CTW circuit, One operation
JO/EWO

and One stand-by


- 2 x 100% electrical dosing pumps for Corrosion Inhibitor to the CTW circuit, One operation Deleted.
and One stand-by
- 2 x 100% electrical dosing pumps for Scale Inhibitor to the CTW circuit, One operation and
16-DEC-21

18-FEB-22

One stand-by
DATE

- 2 x 100% electrical dosing pumps for Dispersant to the CTW circuit, One operation and One
stand-by
- All pumps shall be provided with automatic stroke adjustment
REV
NO.
A

- All interconnecting piping and instrumentation within the package boundary, including all isolation, control and
DISCIPLINE
ENGINEER relief valves; strainers; calibration pots; pulsation dampers; pressure gauges, flowmeter on pumps discharge etc.
SBK - All instrumentation wired to skid edge junction box for wiring to the DCS (wiring from junction box
DATE 18-FEB-22 to DCS by others).
ENGINEERING
MANAGER - Junction box located at skid edge
JHK - Necessary sample and drain connections.
DATE 18-FEB-22 - All other mechanical and electrical equipment, instrumentation and controls necessary for safe and reliable
CERTIFIED operation.
MWK - Ladders and platforms as necessary
DATE 18-FEB-22 - Structural steel base frame with sun shade (VTC for sunshades).
CONSTRUCTION
AGENCY 1.2 Abbreviations
The following acronyms and abbreviations are used in this document:
DATE
OPERATIONS Bbl US Barrels PFD Process Flow Diagram
BEDD Basic Engineering Design Data PSV Process Safety Valve
DATE
CTW Cooling Tower Water RTU Remote Terminal Unit
CONTROL NUMBER
VERIFICATION

CW Cooling Water SCADA Supervisory Control & Data


Aquisition
EDSD

CWS Cooling Water Systems


SG Specific Gravity
DATE:

DCS Distributed Control System


BY:

TBC To Be Confirmed
MBCD Thousand Barrels per Calendar Day
APPROVAL/CERTIFICATION REQUIREMENTS,

VTA VENDOR to advise


THIS INDICATES THAT REV NO ____B_____
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE

MBD Thousand Barrels per Operating Day


(DCC) NO. ___________________________
REVISION CERTIFICATE

VTC VENDOR to confirm


NPS Nominal Pipe Size
P&ID Process and Instrumentation Diagram
MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL
DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 3
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS
SAUDI ARABIAN OIL COMPANY

1.3 Reference Documents


PMT

This document shall be read in conjunction with the following related project documents:

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
ENG'G CERT

MWK
HCK

TD-204411-001 PFD – Machinery Cooling Water


SBK

SBK

TD-234411-001 MSD – Machinery Cooling Water


TD-254481-001 P&ID – Machinery Cooling Water Chemical Dosing
TD-821950 Basic Engineering Design Data (BEDD)
TD-821403 Electrical Basis of Design
TD-821310 C&I Basis of Design
DESCRIPTION

TD-821303 C&I Package Equipment


10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

1.4 Codes and Standards


All Saudi Aramco standards and procedures shall be followed. EPC Contractor attention is drawn to the following:
SABP-A-015 Chemical Injection Systems
31-SAMSS-009 Shop - Fabricated skid mounted units.
32-SAMSS-030 Manufacture of Small Metallic Atmospheric Storage Tanks
JO/EWO

34-SAMSS-831 Instrumentation for Packaged Units


17-SAMSS-515 Auxiliary Electrical Systems for Skid-Mounted Equipment
16-DEC-21

18-FEB-22

SAES-P-111 Grounding
DATE

SAES-L-310 Design of Plant Piping


SAES-A-206 Positive Material Identification
REV
NO.
A

DISCIPLINE
ENGINEER
2.0 PROCESS DUTY
SBK 2.1 Design Parameters
DATE 18-FEB-22
ENGINEERING The CWS Chemical Injection Package is to provide six chemicals to the Cooling Tower Water circuit and Cooling
MANAGER Water circuit at the following key locations:
JHK
DATE Chemicals dosed to the Cooling Tower water circuit via the Cooling Tower Basin (862-S-2301):
18-FEB-22

CERTIFIED - Biocide Deleted.


MWK - Sodium Hypochlorite
DATE 18-FEB-22
CONSTRUCTION
- Scale Inhibitor
AGENCY
- Dispersant
Chemicals dosed to the closed loop cooling water circuit via a slip stream:
DATE
OPERATIONS - Corrosion Inhibitor
- Oxygen Scavenger
DATE
CONTROL NUMBER

The CWS Chemical Injection Package is to provide sufficient dosing for normal operation.
VERIFICATION

Dosage rates to be confirmed by VENDOR.


EDSD

The package will be available 24 hours/day, 365 days/year.


DATE:

Dosing will be fully automatic with minimum operator intervention during normal operation.
BY:

5
The CWS Chemical Injection Package shall have 6 chemical storage tanks, one for each chemical. Each tank
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B_____

should have its dedicated unloading pump.


OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 4
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS SAUDI ARABIAN OIL COMPANY

2.2 Discharge Conditions


PMT

THIS DRAWING AND THE INFORMATION CONTAINED HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR IN PART SHALL BE OBTAINED FROM THIS DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
ENG'G CERT

MWK
HCK

Dosing rate shall be proportional to main stream flow rate.


SBK

SBK

Closed loop Cooling Water circuit:

The dosing pump discharge pressure to the Cooling Water circuit shall be adequate for supplying the chemical
into the discharge line which has a normal injection pressure of 16 - 36 psig and a design pressure of 165 psig.
The main stream flow rate is 7758 USGPM.
DESCRIPTION

Open loop Cooling Tower Water circuit:

The dosing pump discharge pressure to the Cooling Tower Water circuit shall be adequate for supplying the
chemical into the discharge line which has a normal injection pressure of 3 psig and a design pressure of 145
10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

psig. The main stream flow rate is 8940 USGPM. Design make-up water flowrate is 305 USGPM

2.3 Type and Properties of Chemicals - EPC TO CONFIRM


based on chemical vendor information.
The below chemical data is typical, chemical data and dosing rates are to be confirmed by EPC during detailed
JO/EWO

engineering.
Oxygen Scavenger - Hydrazine or equivalent NALCO ELIMIN-OX™
max dosing rate = 1.247 (HOLD) USGPM 0.031 USGPM
Specific Gravity = 1.019 1.02
16-DEC-21

pH= 10.1 –10.7 8.5 - 10


18-FEB-22
DATE

Corrosion Inhibitor - Indion 9125 or equivalent NALCO Trac 109


max dosing rate to closed loop cooling water circuit = 0.028 (HOLD) USGPM 8.346 USGPM
max dosing rate to cooling tower water circuit = 0.025 (HOLD) USGPM Deleted.
REV NO.

Specific Gravity = 1.2 -1.3 1.34


pH <2.0 12.1 - 14
A

DISCIPLINE Biocide - Indion 9052 or equivalent


ENGINEER
max dosing rate = 1.170 (HOLD) USGPM
SBK Specific Gravity = 1.15 - 1.6
DATE 18-FEB-22 pH = 9 - 13
ENGINEERING
MANAGER Sodium Hypochlorite
JHK max dosing rate = 0.171 (HOLD) USGPM 0.198 USGPM
DATE Specific Gravity = 1.21 1.19 - 1.215
18-FEB-22 pH 11.5 – 13.5 12
CERTIFIED
Scale Inhibitor - Indion 9125 or equivalent (VTC) 3D TRASAR™ 3DT435
MWK max dosing rate = (VTC) 0.001 USGPM
DATE Specific Gravity = 1.2 -1.3 (VTC) 1.32
CONSTRUCTION
18-FEB-22
pH <2.0 (VTC) 6.5
AGENCY Dispersant - Indion 2050 or equivalent (VTC) NALCO 8506 PLUS
max dosing rate = (VTC) 0.122 USGPM
DATE Specific Gravity = (VTC) 1.0675
OPERATIONS
pH = (VTC) 7.2

2.4 Additional Process Requirements


DATE
CONTROL NUMBER

The design life time for the CWS Chemical Injection Package (862-U-2302) shall be 20 years.
VERIFICATION

16.1 lb NALCO ELIMIN-OX™


EDSD

Initial fill requirements (for start-up) for Oxygen Scavenger (closed loop): 10 ft³ (@ 37 wt% of

Hydrazine solution for closed loop cooling water flow of 12633 USGPM) (VTC) closed loop cooling water system.
DATE:
BY:

As per SABP-A-026 section 8.3.2, the design of a water treatment program for an open evaporative cooling
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B______

system is a complex procedure, best performed by specialists from the water treatment chemical service
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________

providers.
REVISION CERTIFICATE

Therefore, VENDOR to confirm dosing rates during detailed design. Deleted.


MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL
DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 5
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)

OPRNS
SAUDI ARABIAN OIL COMPANY
2.5 Equipment Design Requirements
PMT

The Package shall include controlled volume pumps, tanks, gauges, strainer, filter, pressure relief valves, sight
ENG'G CERT

MWK

glasses and flow metering/monitoring devices, check valves, hand valves, a power source for the pump and
HCK

instrumentation to control the injection and to monitor its effectiveness.


SBK

SBK

Electrical dosing diaphragm pumps shall be used. Dosing pumps hall be provided with appropriate alarms and

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
automated controls to provide immediate switchover from running to standby pump, in case of pump failure or the
need for maintenance.
Each pump shall have an adjustable stroke length to achieve turndown to 10% of rated injection flow.
Alteration of the stroke length shall be possible without shutting the pump down.
Stroke length to be adjustable, both locally and by a control signal from the remote control room.
DESCRIPTION

Mechanical lost motion capacity adjustment is not permitted. Hydraulic lost motion capacity is not permitted for
duties with motor rating > 1 HP.
Dosing will be fully automatic with minium operator intervention during normal operation.
10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

3.0 MECHANICAL DESIGN


3.1 Design Conditions
While the design conditions of the equipment within the package shall be determined by the Vendor, the following
criteria shall be followed:
JO/EWO

a) Design temperature shall be set at 50ºF above the maximum operating temperature. The minimum upper design
temperature shall be 185ºF (for solar gain).
c) The minimum design (metal) temperature for this equipment is 41°F.
16-DEC-21

18-FEB-22
DATE

d) Design Pressure for pumped systems: process piping and equipment which form part of a pumped hydraulic
system, and which may operate liquid full, shall be designed for the maximum pressure that can be developed by
the pump.
REV
NO.

e) A pressure relief valve must be installed on the pump discharge to vent fluid back into the chemical tank or
A

suction line if pressure builds up. The actual pump internal relief valve setting shall be between 110% and 120% of
DISCIPLINE
ENGINEER
the rated discharge pressure.

SBK 3.2 Materials of Construction


DATE 18-FEB-22
ENGINEERING
Materials of construction shall be selected by Vendor in line with Company and Project standards. Materials shall
MANAGER be appropriate for process design, compatible with all intended process fluids, and suitable for intended application.
JHK
Minimum material grade shall be SS316L. Wetted faces of instrumentation shall be compatible with process fluid
DATE
without coating or lining. Vendor shall ensure material selections and coatings are suitable for external
18-FEB-22
environment in accordance with BEDD requirements. PMI is required as per SAES-A-206.
CERTIFIED
3.3 Noise
MWK
DATE 18-FEB-22 The Package shall be limited to a maximum noise level of 85dB(A) at 1m.
CONSTRUCTION
AGENCY 3.4 Piping
Piping to be adequately supported to avoid vibration. Pipes to be anchored at skid edge. Refer to SAES-L-310
DATE
Section 17.
OPERATIONS
Y-Type strainers shall be installed on the suction to each pump.

DATE Each pump shall have an external PSV with independent discharge line piped back to the tank above the high high
liquid level.
CONTROL NUMBER
VERIFICATION

Check valves shall be external type; not integral to any other inline fitting.
EDSD

Nozzle loads permitted at all terminal points shall be agreed with BUYER. ‘Zero Load’ condition shall not be
accepted.
DATE:

3.5 Tanks
BY:

The chemical storage tanks shall be sized for at least one month's capacity at maximum dosing rate.
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B______
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________

Chemical storage tank may be free standing if sizing prohibits skid mounting.
REVISION CERTIFICATE

Tanks shall be manufactured in accordance with 32-SAMSS-030 by an approved Saudi Aramco fabricator. Vendor

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 6
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF
B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16

DOC CLASS: 2 DSN:


Saudi Aramco 2616-ENG (10/2002)

OPRNS SAUDI ARABIAN OIL COMPANY


Chemical storage tanks shall, as a minimum, be equipped with fill nozzle, utility nozzle, vent, pressure relief,
PMT

overflow, discharge, low point drain, level and temperature instrumentation.


Anti-swirl baffles (vortex breakers) shall be provided on liquid outlet nozzles upstream of a pump suction side.
ENG'G CERT

MWK
HCK

Manways for vertical tanks shall be specified as follows:


SBK

SBK

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
1) One 750 mm (30 in) NPS shell manway.
2) One 750 mm (30 in) NPS roof manway for tanks larger than 10,000 gallons capacity.
Tanks smaller than 36 inches in diameter shall be provided with minimum two flanged NPS 4 openings.
Block valves shall be installed directly at the tank nozzles. If more than one line connects to the same nozzle, valves
shall be installed in each line, in addition to the nozzle block valve.
DESCRIPTION

3.6 Calibration Tube


A clearly graduated calibration tube, vented back to tank above the high high liquid level, shall be provided.
Calibration tube may be common or per-pump and shall be provided with all necessary valves and fittings so the
injection rate can be checked during operation.
10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

Calibration pot shall be robust design with calibrated toughened glass enclosed in steel guard.
Main line chemical feed and calibration tube shut-off valves shall be ¼ turn ball valves and shall be positioned such
that the operator can easily and simultaneously operate both valves during calibration.
3.7 Pumps
Chemical Injection Pumps
JO/EWO

Dosing pumps shall be API 675, controlled volume positive displacement type. Pumps shall be provided from Saudi
Aramco approved manufacturer and meet the requirements of 31-SAMSS-009.
Pump shall be double diaphragm type with a diaphragm failure signalling system.
16-DEC-21

18-FEB-22
DATE

Pump shall have an electronic automatic adjustable stroke length controller, capable of remote and local control
without stopping the pump.
Each pump shall have a minimum operating capacity of 30 - 110% of the recommended dosing rate.
REV NO.

Chemical transfer pumps


DISCIPLINE
ENGINEER Transfer pump is typically an air operated, vertical orientation pump. It will be used to pump (transfer) chemical from
barrel / portable drum into the chemical storage tank.
SBK
DATE 18-FEB-22 The pump should be complete with:
ENGINEERING
MANAGER • Filter / regulator / lubricator for the air line
JHK
DATE • Exhaust muffler
18-FEB-22
CERTIFIED
• Earthing cable on a reel with clamp for attachment to a suitable local earthing / grounding point.
MWK
DATE
• Flexible Suction and Discharge hoses, lengths to be confirmed by CONTRACTOR
18-FEB-22
CONSTRUCTION
AGENCY
Tank transfer/loading pump shall be capable of filling the chemical storage tank within 20 mins.
3.8 Pulsation Damper
DATE
Pulsation damper, to ensure an even chemical application, shall be provided in each pump discharge line and shall
OPERATIONS
be sized to provide sufficient degree of damping. Any fitting required for charging the pulsation dampers shall be
provided. Suppression devices shall be furnished as necessary to meet the following criteria.
DATE Unfiltered peak to peak pulsation levels shall not exceed 3% of:
CONTROL NUMBER

• Rated suction pressure or 100 kPa gauge (15 psig) whichever is less;
VERIFICATION

• Rated discharge pressure or 100 kPa gauge (15 psig) whichever is less.
EDSD

• The following situations shall be avoided:


DATE:
BY:

• Cavitation in the suction or discharge of the pump;


APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B______

• Over delivery due to suction losses or uncontrolled delivery;


OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

• Exceeding maximum allowable working pressure of pressure containing parts.


Any fittings required for charging the pulsation dampers shall be securely connected to the discharge piping and
accessible from grade/skid. Pulsation dampers shall be designed so that no solids settle in the interior of these
MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL
DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 7
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY


4.0 CONTROL, SAFEGUARDING AND INSTRUMENTATION
PMT

The package / equipment shall be controlled by DCS. Safeguarding shall be incorporated in the Emergency
Shutdown system (ESD). Supplier shall provide the functional specification for the control, and logic diagrams or
ENG'G CERT

MWK
HCK

similar for the safeguarding. The incorporation of the control in DCS and safeguarding in the ESD is by Others.
Total flowrate signal (by Others) will be used to provide the ratio control to the dosing pump to adjust the dosing
SBK

SBK

rate accordingly. The DCS control system shall supply a flow demand signal to each package.

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
The dosing package tank shall be provided with a local level gauge and level transmitter to provide remote level
indication, including high and low level alarms.
A temperature gauge shall be supplied on the tank for indication of fluid temperature.
The pumps shall be provided with a local panel with start/stop facility, emergency stop, selector switch and running
indication. Remote running indication, pump selection and pump start/stop/trip shall also be provided.
DESCRIPTION

A pressure gauge shall be supplied on each pump discharge.


Pressure and flow transmitters shall be supplied on a common service discharge line to provide remote indications.
10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

Double diaphragm pumps shall be provided with a diaphragm failure signal system.
Instrumentation shall be wired to skid edge Junction Box. Wiring to from the Junction Box to the DCS will be by
Others.
Ref.: 34-SAMSS-831 and TD-821310.

5.0 ELECTRICAL
JO/EWO

CWS Chemical Injection Package is installed in area classification: Safe Area


Electrical installation shall be in accordance with 'Auxiliary Electrical Systems for Skid-Mounted Equipment' 17-
SAMSS-515, and all applicable referenced specifications and standards.
16-DEC-21

18-FEB-22
DATE

All electrical equipment shall meet ambient conditions as stated in Electrical Design Basis TD-821403.
All equipment installed in hazardous (classified) areas, electrical equipment/component meeting the requirement of
IEC 60079 shall be labelled, listed, or certified by any of the agencies in the Approved IECEx Certification Bodies
REV
NO.

(ExCBs) under the IECEx Certified Equipment Scheme. Method of protection must be marked and must
DISCIPLINE correspond with NEC Article 505 requirements for suitable protection method(s) for the hazardous area where the
ENGINEER equipment is applied.
SBK
Power cablings to motors will be provided by CONTRACTOR directly to the motor terminal boxes.
DATE 18-FEB-22
ENGINEERING VENDOR shall provide on-skid supporting cable tray for the incoming power cables.
MANAGER

JHK All on-skid grounding and bonding connection shall be wired to skid-edge earth busbars. CONTRACTOR shall
DATE 18-FEB-22
provide cabling up to these earth busbars. The grounding and bounding shall be as per SAES-P-111.
CERTIFIED Electrical control cabling on skid shall be wired to skid-edge junction boxes by VENDOR. CONTRACTOR shall
provide control cabling up to these junction boxes.
MWK
DATE 18-FEB-22 6.0 UTILITIES
CONSTRUCTION
AGENCY Following utilities are envisaged to be required for the package.
- Electrical Power 460V / 3Phase / 60Hz (at Users)
DATE

OPERATIONS - Control Power 230V / 1Phase / 60Hz

- Demineralised water
DATE
- Nitrogen
CONTROL NUMBER
VERIFICATION

- Instrument Air
EDSD

VENDOR to indicate requirement of any other utilities.


DATE:

For operating and design conditions of utilities, refer to the ‘Basic Engineering Design Data’ document.
BY:
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B______
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


INJECTION PACKAGE
DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
JFGP UTILITIES DAT 8
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY


Pump Tag No TBC TBC TBC TBC
PMT

No. of Pumps 2x100% 2x100% 2x100% 2x100%


ENG'G CERT

No. of Heads/Pump 1 1 1 1
MWK
HCK

Service Biocide Injection Sodium Hypochlorite Corrosion Inhibitor Injection to CW Corrosion Inhibitor Injection to CTW
Chemical Ref. section 2.3 Ref. section 2.3 Ref. section 2.3 Ref. section 2.3
SBK

SBK

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Flow per Head VTC VTC Ref. section 2.3 VTC
Discharge Pressure psig Ref. section 2.2 Ref. section 2.2 Ref. section 2.2 Ref. section 2.2

Pump Tag No TBC TBC TBC


No. of Pumps 2x100% 2x100% 2x100%
No. of Heads/Pump 1 1 1
Service Scale Inhibitor Injection Dispersant Injection Oxygen Scavenger Injection
DESCRIPTION

Chemical Ref. section 2.3 Ref. section 2.3 Ref. section 2.3

Flow per Head VTC VTC Ref. section 2.3

Discharge Pressure psig Ref. section 2.2 Ref. section 2.2 Ref. section 2.2
34-15430-3002 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

BIOCIDE TANK BIOCIDE TANK MIXER ACCESSORIES


Equip. No. TBC Equipment No. TBC Pulsation DampEners. Suction / Discharge YES
VTA 38 (HOLD) ft3
Working Vol. (min. 1 month) Manufacturer VTA Level Instruments: Gauge YES
Dia (ins) x Height (ins) VTA Model VTA High Alarm YES
Thickness VTA Impeller Dia VTA Low Alarm YES
JO/EWO

Design Pressure Atmos. + static head Shaft Dia VTA Pump Trip YES
Material SS316L (NOTE 1) Shaft Length VTA Strainers: per System / Pump / Head YES
Corrosion allowance NIL Shaft Seal arrangement VTA Calibration: Level Gauge / Calibration Gauge YES
Lid YES Material Wetted Parts (Note 1) VTA Relief Valve External to Pump YES
16-DEC-21

18-FEB-22
DATE

Access HINGED LID Mounting Arrangement VTA Pressure Gauges ON DISCHARGE YES
Atmospheric Vent / Purge System Motor 460 Volts 3 Ph 60Hz kW VTA Diaphragm failure signal system : YES
Dissolving Basket N/A Chemical Mixed VTA
Relief Valve N/A Mixing Time VTA
REV
NO.

SKID DETAILS TERMINAL POINTS


DISCIPLINE
ENGINEER
DIMENSIONS WEIGHTS No. DUTY FLANGE SIZE FLANGE RATING

SBK LENGTH VTA ft DRY VTA lbs TP01 CHEMICAL INLET VTA VTA
DATE 18-FEB-22
WIDTH VTA ft OPERATING VTA lbs TP02 DRAIN VTA VTA
ENGINEERING
HEIGHT VTA ft SHIPPING VTA lbs TP03 VENT VTA VTA
MANAGER

JHK Sunshade VTA TP04 DISCHARGE VTA VTA


DATE 18-FEB-22
Lifting Lugs YES TP05 TANK UTILITY WATER VTA VTA

CERTIFIED Earthing Bosses YES TP06 INSTRUMENT AIR VTA VTA

MWK Piping Spec: VTA (NOTE 1)


DATE 18-FEB-22 Hazardous Area Classification: SAFE AREA
CONSTRUCTION
AGENCY
Weather Rating SEE BEDD DOCUMENT

NOTES

DATE 1) Materials of construction shall be suitable for the concentrated chemical solution.
OPERATIONS 2) Equipment Tag Nos shall be confirmed by EPC Contractor during Detailed Design phase. will be finalized later.
3) VTA = Vendor to advise. TBC = To be confirmed.

DATE
CONTROL NUMBER
VERIFICATION
EDSD

DATE:
BY:
THIS INDICATES THAT REV NO ____B______
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

APPROVAL/CERTIFICATION

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
REQUIREMENTS,

JFGP UTILITIES DAT 9


862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY


Remove mixer requirement.
SODIUM HYPOCHLORITE TANK SODIUM HYPOCHLORITE TANK MIXER ACCESSORIES
PMT

Equip. No. TBC 1145 Equipment No. TBC Pulsation DampEners. Suction / Discharge YES
VTA 988 (HOLD) ft3
ENG'G CERT

Working Vol. Manufacturer VTA Level Instruments: Gauge YES


MWK
HCK

(min. 1 month)
Dia (ins) x Height (ins) VTA Model VTA High Alarm YES

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Thickness VTA Impeller Dia VTA Low Alarm YES
SBK

SBK

Design Pressure Atmos. + static head Shaft Dia VTA Suitalbe material to be Pump Trip YES
proposed by vendor.
Material SS316L VTA (NOTE 1) Shaft Length VTA Strainers: per System / Pump / Head YES
Corrosion allowance NIL Shaft Seal arrangement VTA Calibration: Level Gauge / Calibration Gauge YES
Lid YES Material Wetted Parts (Note 1) VTA Relief Valve External to Pump YES
Access HINGED LID Mounting Arrangement VTA Pressure Gauges ON DISCHARGE YES
Atmospheric Vent / Purge System Motor 460 Volts 3 Ph 60Hz kW VTA Diaphragm failure signal system : YES
Dissolving Basket N/A Chemical Mixed VTA
DESCRIPTION

Relief Valve N/A Mixing Time VTA

SKID DETAILS TERMINAL POINTS

DIMENSIONS WEIGHTS No. DUTY FLANGE SIZE FLANGE RATING


10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

LENGTH VTA ft DRY VTA lbs TP01 CHEMICAL INLET VTA VTA
WIDTH VTA ft OPERATING VTA lbs TP02 DRAIN VTA VTA
HEIGHT VTA ft SHIPPING VTA lbs TP03 VENT VTA VTA
Sunshade VTA TP04 DISCHARGE VTA VTA
Lifting Lugs YES TP05 TANK UTILITY WATER VTA VTA
Earthing Bosses YES TP06 INSTRUMENT AIR VTA VTA
JO/EWO

Piping Spec: VTA (NOTE 1)


Hazardous Area Classification: SAFE AREA
Weather Rating SEE BEDD DOCUMENT
NOTES
16-DEC-21

18-FEB-22
DATE

1) Materials of construction shall be suitable for the concentrated chemical solution.


2) Equipment Tag Nos shall be confirmed by EPC Contractor during Detailed Design phase. will be finalized later.
3) VTA = Vendor to advise. TBC = To be confirmed.
REV
NO.

DISCIPLINE
ENGINEER

SBK
DATE 18-FEB-22
ENGINEERING
MANAGER

JHK
DATE 18-FEB-22

CERTIFIED

MWK
DATE 18-FEB-22
CONSTRUCTION
AGENCY

DATE
OPERATIONS

DATE
CONTROL NUMBER
VERIFICATION
EDSD

DATE:
BY:
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE
THIS INDICATES THAT REV NO

APPROVAL/CERTIFICATION

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REQUIREMENTS,

INJECTION PACKAGE
JFGP UTILITIES DAT 10
____B______

862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY


Remove mixer requirement.
CORROSION INHIBITOR TANK CORROSION INHIBITOR TANK MIXER ACCESSORIES
PMT

Equip. No. TBC 67 Equipment No. TBC Pulsation DampEners. Suction / Discharge YES
VTA 211 (HOLD) ft3
VTA YES
ENG'G CERT

Working Vol. Manufacturer Level Instruments: Gauge


MWK
HCK

(min. 1 month)
Dia (ins) x Height (ins) VTA Model VTA High Alarm YES

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Thickness VTA Impeller Dia VTA Low Alarm YES
SBK

SBK

Design Pressure Atmos. + static head Shaft Dia VTA Pump Trip YES
Material SS316L (NOTE 1) Shaft Length VTA Strainers: per System / Pump / Head YES
Corrosion allowance NIL Shaft Seal arrangement VTA Calibration: Level Gauge / Calibration Gauge
Lid YES Material Wetted Parts (Note 1) VTA Relief Valve External to Pump YES
Access HINGED LID Mounting Arrangement VTA Pressure Gauges ON DISCHARGE
Atmospheric Vent / Purge System Motor 460 Volts 3 Ph 60Hz kW VTA Diaphragm failure signal system : YES
Dissolving Basket N/A Chemical Mixed VTA
DESCRIPTION

Relief Valve N/A Mixing Time VTA

SKID DETAILS TERMINAL POINTS

DIMENSIONS WEIGHTS No. DUTY FLANGE SIZE FLANGE RATING


10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

LENGTH VTA ft DRY VTA lbs TP01 CHEMICAL INLET VTA VTA
WIDTH VTA ft OPERATING VTA lbs TP02 DRAIN VTA VTA
HEIGHT VTA ft SHIPPING VTA lbs TP03 VENT VTA VTA
Sunshade VTA TP04 DISCHARGE VTA VTA
Lifting Lugs YES TP05 TANK UTILITY WATER VTA VTA
Earthing Bosses YES TP06 INSTRUMENT AIR VTA VTA
JO/EWO

Piping Spec: VTA (NOTE 1)


Hazardous Area Classification: SAFE AREA
Weather Rating SEE BEDD DOCUMENT
SCALE INHIBITOR TANK
Remove mixer requirement.
SCALE INHIBITOR TANK MIXER ACCESSORIES
16-DEC-21

18-FEB-22

3.3
DATE

Equip. No. TBC Equipment No. TBC Pulsation DampEners. Suction / Discharge
VTA 1057 (HOLD) ft3
Working Vol. (min. 1 month) Manufacturer VTA Level Instruments: Gauge YES
Dia (ins) x Height (ins) VTA Model VTA High Alarm YES
Thickness VTA Impeller Dia VTA Low Alarm YES
REV
NO.

Design Pressure Atmos. + static head Shaft Dia VTA Pump Trip YES

DISCIPLINE
Material SS316L (NOTE 1) Shaft Length VTA Strainers: per System / Pump / Head YES
ENGINEER

SBK Corrosion allowance NIL Shaft Seal arrangement VTA Calibration: Level Gauge / Calibration Gauge YES
DATE 18-FEB-22
Lid YES Material Wetted Parts (Note 1) VTA Relief Valve External to Pump YES
ENGINEERING
Access HINGED LID Mounting Arrangement VTA Pressure Gauges ON DISCHARGE YES
MANAGER

JHK Atmospheric Vent / Purge System Motor 460 Volts 3 Ph 60Hz kW VTA Diaphragm failure signal system : YES
DATE 18-FEB-22
Dissolving Basket N/A Chemical Mixed VTA

CERTIFIED Relief Valve N/A Mixing Time VTA

MWK SKID DETAILS TERMINAL POINTS


DATE 18-FEB-22
DIMENSIONS WEIGHTS No. DUTY FLANGE SIZE FLANGE RATING
CONSTRUCTION
LENGTH VTA ft DRY VTA lbs TP01 CHEMICAL INLET VTA VTA
AGENCY
WIDTH VTA ft OPERATING VTA lbs TP02 DRAIN VTA VTA

DATE HEIGHT VTA ft SHIPPING VTA lbs TP03 VENT VTA VTA
OPERATIONS Sunshade VTA TP04 DISCHARGE VTA VTA
Lifting Lugs YES TP05 TANK UTILITY WATER VTA VTA

DATE Earthing Bosses YES TP06 INSTRUMENT AIR VTA VTA


Piping Spec: VTA (NOTE 1)
CONTROL NUMBER
VERIFICATION

Hazardous Area Classification: SAFE AREA


EDSD

Weather Rating SEE BEDD DOCUMENT


NOTES
DATE:

1) Materials of construction shall be suitable for the concentrated chemical solution.


BY:

2) Equipment Tag Nos shall be confirmed by EPC Contractor during Detailed Design phase. will be finalized later.
THIS INDICATES THAT REV NO ____B_____

3) VTA = Vendor to advise. TBC = To be confirmed.


OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

APPROVAL/CERTIFICATION

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REQUIREMENTS,

INJECTION PACKAGE
JFGP UTILITIES DAT 11
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 2616-ENG (10/2002)
OPRNS

SAUDI ARABIAN OIL COMPANY


Remove mixer requirement.
DISPERSANT TANK DISPERSANT TANK MIXER ACCESSORIES
PMT

Equip. No. TBC 21 Equipment No. TBC Pulsation DampEners. Suction / Discharge
VTA 3.1 (HOLD) ft3
VTA YES
ENG'G CERT

Working Vol. Manufacturer Level Instruments: Gauge


MWK
HCK

(min. 1 month)

Dia (ins) x Height (ins) VTA Model VTA High Alarm YES

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Thickness VTA Impeller Dia VTA Low Alarm YES
SBK

SBK

Design Pressure Atmos. + static head Shaft Dia VTA Pump Trip YES
Material SS316L (NOTE 1) Shaft Length VTA Strainers: per System / Pump / Head YES
Corrosion allowance NIL Shaft Seal arrangement VTA Calibration: Level Gauge / Calibration Gauge
Lid YES Material Wetted Parts (Note 1) VTA Relief Valve External to Pump YES
Access HINGED LID Mounting Arrangement VTA Pressure Gauges ON DISCHARGE
Atmospheric Vent / Purge System Motor 460 Volts 3 Ph 60Hz kW VTA Diaphragm failure signal system : YES
Dissolving Basket N/A Chemical Mixed VTA
DESCRIPTION

Relief Valve N/A Mixing Time VTA

SKID DETAILS TERMINAL POINTS

DIMENSIONS WEIGHTS No. DUTY FLANGE SIZE FLANGE RATING


10-14329-0003 ISSUED FOR REVIEW

10-14329-0003 ISSUED FOR REVIEW

LENGTH VTA ft DRY VTA lbs TP01 CHEMICAL INLET VTA VTA
WIDTH VTA ft OPERATING VTA lbs TP02 DRAIN VTA VTA
HEIGHT VTA ft SHIPPING VTA lbs TP03 VENT VTA VTA
Sunshade VTA TP04 DISCHARGE VTA VTA
Lifting Lugs YES TP05 TANK UTILITY WATER VTA VTA
Earthing Bosses YES TP06 INSTRUMENT AIR VTA VTA
JO/EWO

Piping Spec: VTA (NOTE 1)


Hazardous Area Classification: SAFE AREA
Weather Rating SEE BEDD DOCUMENT
Remove mixer requirement.
OXYGEN SCAVENGER TANK OXYGEN SCAVENGER TANK MIXER ACCESSORIES
16-DEC-21

18-FEB-22

0.25
DATE

Equip. No. TBC Equipment No. TBC Pulsation DampEners. Suction / Discharge
VTA 10 (HOLD) ft3
Working Vol. (min. 1 month) Manufacturer VTA Level Instruments: Gauge YES
Dia (ins) x Height (ins) VTA Model VTA High Alarm YES
Thickness VTA Impeller Dia VTA Low Alarm YES
REV
NO.

Design Pressure Atmos. + static head Shaft Dia VTA Pump Trip YES

DISCIPLINE
Material SS316L (NOTE 1) Shaft Length VTA Strainers: per System / Pump / Head YES
ENGINEER

SBK Corrosion allowance NIL Shaft Seal arrangement VTA Calibration: Level Gauge / Calibration Gauge YES
DATE 18-FEB-22
Lid YES Material Wetted Parts (Note 1) VTA Relief Valve External to Pump YES
ENGINEERING
Access HINGED LID Mounting Arrangement VTA Pressure Gauges ON DISCHARGE YES
MANAGER

JHK Atmospheric Vent / Purge System Motor 460 Volts 3 Ph 60Hz kW VTA Diaphragm failure signal system : YES
DATE 18-FEB-22
Dissolving Basket N/A Chemical Mixed VTA

CERTIFIED Relief Valve N/A Mixing Time VTA

MWK SKID DETAILS TERMINAL POINTS


DATE 18-FEB-22
DIMENSIONS WEIGHTS No. DUTY FLANGE SIZE FLANGE RATING
CONSTRUCTION
LENGTH VTA ft DRY VTA lbs TP01 CHEMICAL INLET VTA VTA
AGENCY
WIDTH VTA ft OPERATING VTA lbs TP02 DRAIN VTA VTA

DATE HEIGHT VTA ft SHIPPING VTA lbs TP03 VENT VTA VTA
OPERATIONS Sunshade VTA TP04 DISCHARGE VTA VTA
Lifting Lugs YES TP05 TANK UTILITY WATER VTA VTA

DATE Earthing Bosses YES TP06 INSTRUMENT AIR VTA VTA


Piping Spec: VTA (NOTE 1)
CONTROL NUMBER
VERIFICATION

Hazardous Area Classification: SAFE AREA


EDSD

Weather Rating SEE BEDD DOCUMENT


NOTES
DATE:

1) Materials of construction shall be suitable for the concentrated chemical solution.


BY:

2) Equipment Tag Nos shall be confirmed by EPC Contractor during Detailed Design phase. will be finalized later.
THIS INDICATES THAT REV NO ____B_____

3) VTA = Vendor to advise. TBC = To be confirmed.


OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

APPROVAL/CERTIFICATION

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
REQUIREMENTS,

INJECTION PACKAGE
JFGP UTILITIES DAT 12
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 8010-ENG(11/2010)

OPRNS SAUDI ARABIAN OIL COMPANY


POSITIVE DISPLACEMENT PUMP DATA SHEET
NOTE: INDICATES INFORMATION TO BE COMPLETED BY THE PURCHASER; BY MANUFACTURER
PMT

DESIGN OPERATING DATA PERFORMANCE DATA


ENG'G CERT

A. SERVICE E PUMP CHARACTERISTICS


MWK
HCK

1. CONTINUOUS INTERMITTENT STAND BY 1. RATED CAPACITY USgal/hr

2. ATTENDED UNATTENDED 2. TURNDOWN RATIO


SBK

SBK

3. PUMP FUNCTION CHEMICAL INJECTION 3. LINEARITY %

NOTE 1 4. STEADY STATE ACCURACY %

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
B. LIQUID CHARACTERISTICS 5. FLOW REPEATABILITY %

1. LIQUID PUMPED NOTE 1, 3 6. MAX./MIN. ALLOWABLE SPEED RPM -

2. FLOW TEMPERATURE °F AMB 7. MAX./MIN. ALLOWABLE TEMP. °F -

.1 MAX. FLOW TEMPERATURE °F 131 8. BHP CONS. AT MAX. CAPACITY (C.1)* BHP

3. SPECIFIC GRAVITY AT FLOW TEMP./ MAX. TEMP. NOTE3 NOTE3 9. BHP CONS. AT MAX. CAP. AND 110% OF E.12* BHP

4. VISCOS. AT FLOW TEMP./ MAX. TEMP. cP NOTE3 NOTE3 10. MAX. DISCH. PRESSURE psig

5. VAPOR PRESSURE AT FLOW TEMP. psi(a) TBC NOTE3 11. MAX. RELIEF VALVE SETTING psig
DESCRIPTION

.1 V.P AT MAX. FLOW TEMP. psi(a) TBC NOTE3 NOTE3 12. ACTUAL RELIEF VALVE SETTING psig

6. PRINCIPAL CORROSIVES 13. PLUNGER DIAMETER in

14. STROKE LENGTH (MAX.) in

15. NPSHR AT MAXIMUM CAPACITY ft

.1 pH OR pH RANGE OF LIQUID PUMPED NOTE3 16. MAX. ALLOW. WORKING PRESS.

C. RATED OPERATING CONDITIONS ( AT °F psig

MIN. MAX NORMAL 17. MINIMUM REQ. DIFFERENTIAL PRESS. psig


VTA VTA
16-DEC-21 10-14329-0003 ISSUED FOR REVIEW

18-FEB-22 10-14329-0003 ISSUED FOR REVIEW

1. CAPACITY RANGE Usgph NOTE3 *) E.8 AND E.9 TO INCLUDE GEAR AND COUPLING LOSSES
NOTE NOTE

2. NPSH AVAILABLE AT SUCTION PORT ft VTA EQUIPMENT DATA

3. SUCTION PRESS. MIN/RATED psi(g) VTA VTA F. PUMP AND COUPLING MODEL,
4. TOTAL DIFFERENTIAL PRESSURE psi TBC VTA WEIGHTS, LUBRICATION
5. RATED DISCHARGE PRESSURE psi(g) VTA 1. MANUFACTURER

6. LOCATION .1 TYPE/SIZE
JO/EWO

OFFSHORE ONSHORE OUTDOOR .2 SERIAL NUMBER(S)

7. AREA CLASSIFICATION

VENDOR
CLASS SAFE ZONE GROUP TEMP. 2. PUMP EQUIPPED WITH : REQ'D
DATE

SUPPLY

8. SUCTION/DISCHARGE PIPE
.1 DRIVER ( INCL. COUPLING
TOTAL ACTUAL LENGTH ft / AND GUARD IF REQUIRED)
REV
NO.

INTERNAL DIAMETER in / .2 BASE PLATE

DISCIPLINE
.3 SUCTION STRAINER ( Y-TYPE )
ENGINEER

SBK D. PUMP/DRIVER/TRANSMISSION TYPE .4 SUCTION MANIFOLD


SUCTION PULSATION BOTTLE ( IF
DATE 18-FEB-22
1. PUMP TYPE .5
REQUIRED )
ENGINEERING
SIMPLEX
MANAGER .6 INTEGRAL ADJUSTABLE
SINGLE DIAPHRAGM DOUBLE DIAPHRAGM HYDRAULIC RELIEF VALVE
JHK
.7 DISCHARGE PULSATION BOTTLE ( IF
DATE 18-FEB-22
PLASTIC DIAPHRAGM (S) METAL DIAPHRAGM (S)
REQUIRED )
CERTIFIED .8 DISCHARGE MANIFOLD

.1 SPEED OR SPEED RANGE RPM 3. COUPLING MAKE TYPE MODEL


MWK
DATE 18-FEB-22
.2 DIRECTION OF ROTATION CW CCW 4. WEIGHTS
CONSTRUCTION
( LOOKING FROM DRIVING END ) 1. PUMP lbs
AGENCY
2. ELECTRIC MOTOR DRIVER CONST. SPEED 2. DRIVER ( INCL. COUPLING) TOTAL WEIGHT lbs

DATE VARIABLE SPEED 5. LUBRICANTS

OPERATIONS .1 SPEED/SPEED RANGE RPM .1 BEARING LUBRICANT ISO VG 46 (VTC)

.2 RATED BHP (EXCLUD. SERVICE FACTOR) BHP SAUDI ARAMCO EQUIV.

DATE .3 HORIZONTAL VERTICAL .2 LUBRICANT


EDSD VERIFICATION

.4 FLANGE MOUNTED FOOT MOUNTED SAUDI ARAMCO EQUIV.


CONTROL NUMBER

.5 SHAFT EXTENSION: STANDARD SPECIAL: .3 HYDRAULIC FLUID

3 INTERMEDIATE TRANSMISSION SAUDI ARAMCO EQUIV.


GEAR BOX RATIO :
DATE:

MAKE AGMA FACTOR UTILITY DATA


BY:

MODEL G. UTILITIES
APPROVAL/CERTIFICATION REQUIREMENTS,

4. INTEGRAL SPEED REDUCER, TYPE 1. ELECTRIC POWER AVAILABLE


THIS INDICATES THAT REV NO ____B_____
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________

AC PHASE
RATIO : AGMA FACTOR DC VOLTS HERTZ
REVISION CERTIFICATE

5. COUPLING .1 MAIN ELECTRIC DRIVER AC DC 460 3PH / 60Hz

FLEXIBLE .2 CONTROL AC 230 1PH / 60Hz

NONE (INTEGRALLY MOUNTED)


MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL
DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 13
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 8010-ENG(11/2010)
OPRNS
SAUDI ARABIAN OIL COMPANY
POSITIVE DISPLACEMENT PUMP DATA SHEET
NOTE: INDICATES INFORMATION TO BE COMPLETED BY THE PURCHASER; BY MANUFACTURER
PMT

PUMP OPERATING DATA BUYER'S REFERENCE


ENG'G CERT

H. MATERIALS OF CONSTRUCTION
MWK
HCK

ASTM OR EQUIVILANT 1. DRIVER DATA SHEET Page 15-16

1. LIQUID END VTA 2.


SBK

SBK

2. PLUNGER VTA 3.

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
3. CONTOUR PLATE VTA

4. HYDRAULIC DIAPHRAGM VTA NOTES

5. PLUNGER DIAPHRAGM VTA 1) VENDOR shall complete this pump data sheet template for

6. PLUNGER PACKING VTA each pump duty and chemical.

7. FRAME VTA

8. SUCTION PULSATION BOTTLE VTA 2) Minimum pump differential pressure required to ensure guaranteed

9. DISCHARGE PULSATION BOTTLE VTA accuracy shall be specified by Supplier.

10. CHECK VALVE/BALLS VTA


DESCRIPTION

11. RELIEF VALVE, SEAT AND TRIM VTA 3) Preliminary Chemical Information to be considerd as below. (HOLD)

12. BASEPLATE VTA 3-1) Oxygen Scavenger (normal injection rate : 74.8 USGPH) 1.88 USGPH
13. PIPEWORK VTA - Specific gravity : 1 - 1.05 1.02
- Viscosity (cP) : 1 - 10 2.9
J. PUMP CONSTRUCTION - Vapor Pressure (psia) : 0.23

1. PUMP NOZZLE - PH : 6 - 8 8.5 - 10


.1 SUCTION SIZE ASME RATING FACING POSITION

500.78 USGPH (closed loop)


16-DEC-21 10-14329-0003 ISSUED FOR REVIEW

18-FEB-22 10-14329-0003 ISSUED FOR REVIEW

THREADED IN. ASME B2.1 TAPERED 3-2) Corrosion Inhibitor

FLANGED IN. - Normal injection rate : 1.68 (closed loop) / 1.53 (open loop) USGPH

- Specific gravity : 1.33 1.34


.2 DISCHARGE SIZE ASME RATING FACING POSITION - Viscosity (cP) : N/A

THREADED IN. ASME B2.1 TAPERED - Vapor Pressure (psia) : N/A

FLANGED IN. - PH : 13 12.1 - 14


JO/EWO

2 CAPACITY ADJUSTMENT 3-3) Biocide (normal injection rate : 70.2 USGPH)

.1 MECHANICAL, TYPE - Specific gravity : 1.15 - 1.6

HYDRAULIC STROKE SPEED ADJUSTMENT - Viscosity (cP) : 2.5


DATE

.2 ADJUST. WHILE RUNNING/AND DURING VTAND STILL - Vapor Pressure (psia) : 0.34

.3 LOCAL MICROMETER REMOTE BOTH NOTE 1 - PH : 9 - 13


REV
NO.

.4 MANUAL INCL. LOCKING DEVICE AUTOMATIC


DISCIPLINE
ENGINEER
.5 MANUAL TO AUTO SWITCH NOTE 6 3-4) Sodium Hypochlorite (normal injection rate : 10.3 USGPH) 11.903 USGPH
.6 4 20mA INPUT SIGNAL & 4 20mA REMOTE SIGNAL - Specific gravity : 1.19 - 1.215
SBK
DATE 3. PULSATION BOTTLES, TYPE NOTE 2 - Viscosity (cP) : 2.5
18-FEB-22
ENGINEERING
.1 SUCT.-VOL./CHARG. PRESS. cu.ft./psi(g) - Vapor Pressure (psia) : 0.23 / 1.93
MANAGER
0.34
.2 DISCH.-VOL./CHARG. PRESS. cu.ft./psi(g) - PH : 12
JHK
DATE 18-FEB-22
.3 CHARGING MEDIUM:

CERTIFIED 4. VALVES 3-5) Scale Inhibitor (normal injection rate : 11 USGPH) 0.035 USGPH
MWK
.1 SUCTION VALVES SINGLE DOUBLE - Specific gravity : 1 - 1.15 1.32
DATE SIZE BALL OTHER - Viscosity (cP) : 1 - 10
18-FEB-22
CONSTRUCTION
.2 DISCHARGE VALVES SINGLE DOUBLE - Vapor Pressure (psia) : N/A
AGENCY
SIZE BALL OTHER - PH : 4 - 6 6.5
.3 BRINELL HARDNESS: VALVE SEAT
DATE
OPERATIONS 5. LUBRICATION 3-6) Disperant (normal injection rate : 13.1 USGPH) 7.324 USGPH
.1 PUMP, GEAR, BEARINGS - Specific gravity : 1.076 1.0675
DATE SPLASH SUBMERGED FORCED - FEED - Viscosity (cP) : 8 147.5
EDSD VERIFICATION

.2 DRIVER - Vapor Pressure (psia) : N/A


CONTROL NUMBER

SPLASH SUBMERGED - PH : 3.6 - 4.3 7.2


6. TYPE OF DOUBLE DIAPHRAGM PUMPS OF THE SAME TYPE & SIZE IN OPERATION

7. TYPE OF DOUBLE DIAPHR. RUPTURE SIGNALING PUMPS MARK NO. INQ./ORDER NO. DATA SHEET NO.
DATE:

-G-
BY:

8. VOLUMETRIC VENTING VALVE REQUIRED


APPROVAL/CERTIFICATION REQUIREMENTS,

THIS DATA SHEET COVERS 2 x 100% PUMP(S)


THIS INDICATES THAT REV NO ____B_____
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________

K. SPECIAL REQUIREMENTS PUMPS MARK NO(S).


REVISION CERTIFICATE

PUMP TO COMPLY WITH 31-SAMSS-009

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 14
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 17-SAMSS-503 (04/00)
OPRNS SAUDI ARABIAN OIL COMPANY
17-SAMSS-503, SEVERE DUTY TOTALLY ENCLOSED SQUIRREL CAGE INDUCTION MOTORS
APPLICABLE TO: Inquiry Proposal Purchase As Built
PMT

Plant: Plant No. Driven Equipment:


CHEMICAL INJECTION PUMP
ENG'G CERT

MWK
HCK

Purchaser’s Data to Be Supplied With Inquiry:


SBK

SBK

BASIC DATA

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
Volts: 460 Phase: 3 Hertz: 60 Nameplate: kW hp
Full Load RPM: Speed Range for Variable Speed Drive:
Rotation When Facing Motor Opposite Drive End:
Clockwise Counter-Clockwise Bi-Directional
Motor Thrust Loads: None Other
Type Load: Direct Coupled Belt Driven Other
NEMA Torque Design: “B” (normal) Other (specify)
DESCRIPTION

SITE DATA

Area Classification: Non-Hazardous


Hazardous (Classified) Class: Zone Group:
Temperature Class:
Elevation (Specify if Above 3000 ft.): ft

STARTING
16-DEC-21 10-14329-0003 ISSUED FOR REVIEW

18-FEB-22 10-14329-0003 ISSUED FOR REVIEW

Full Voltage Reduced Voltage % and Type


Variable Frequency Drive Unit Type
VFD Details Attached (If motor purchased separately from drive unit.)

MOUNTING
Horizontal Vertical Shaft Up Vertical Shaft Down
JO/EWO

Foot Mounted Flange Mounted, NEMA Type

ENCLOSURE
DATE

TEFC TENV Explosion Proof Other


Main Terminal Box Conduit Hub Size: in.
REV
NO.
A

DISCIPLINE
ENGINEER Space Heaters

SBK Space Heater Required for motors rated less than 75kW (100HP); Operating Voltage: 120 V, 1 ph
DATE 18-FEB-22 Other Voltage Max. Surface Temp. at Operating Volts ºC
ENGINEERING
MANAGER Heater Leads: Main Terminal Box Separate Heater Terminal Box
JHK
DATE 18-FEB-22
CERTIFIED

MWK
DATE 18-FEB-22
CONSTRUCTION
AGENCY

DATE
OPERATIONS

DATE
EDSD VERIFICATION

CONTROL NUMBER

DATE:
BY:
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B_____
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 15
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16
DOC CLASS: 2 DSN:
Saudi Aramco 17-SAMSS-503 (04/00)
OPRNS
SAUDI ARABIAN OIL COMPANY
17-SAMSS-503, SEVERE DUTY TOTALLY ENCLOSED SQUIRREL CAGE INDUCTION MOTORS
PMT

Vendor Data:
ENG'G CERT

CHEMICAL INJECTION PUMP


MWK
HCK

GENERAL INFORMATION
SBK

SBK

Manufacturer Model Serial No.

THIS DRAWING AND THE INFORMATION CONTAINED WITHIN HEREIN ARE THE SOLE PROPERTY OF SAUDI ARAMCO. NO REPRODUCTION IN FULL OR PART SHALL BE OBTAINED FROM THE DOCUMENT WITHOUT THE WRITTEN CONSENT OF ITS OWNER.
MOTOR DATA
Rating Data at 1.0 Service Factor:
Nameplate Power kW (hp) Voltage 460 Phase 3 Hertz 60
Full Load Speed RPM Enclosure Type Frame Size
Rotation When Facing Motor Opposite Drive End:
Clockwise Counter-Clockwise Bi-Directional
DESCRIPTION

Torque:
Speed-Torque Curve No. Speed-Current Curve No.

Design Data at 1.0 Service Factor and Rated Voltage


No Load Current Amps
Load 25% 50% 75% Full
Amperes
16-DEC-21 10-14329-0003 ISSUED FOR REVIEW

18-FEB-22 10-14329-0003 ISSUED FOR REVIEW

Power Factor
Nominal Efficiency
Guaranteed Efficiency

Locked Rotor Amps at Rated Voltage


JO/EWO

Insulation System
Class Temperature Class ºC above ºC ambient at 1.0 SF
DATE

Bearing Information
Coupling End Bearing: Manufacturer’s Type Part No.
REV
NO.
A

Outboard End Bearing: Manufacturer’s Type Part No.


DISCIPLINE
ENGINEER

SBK Certification: Class Group Division Agency


DATE 18-FEB-22
ENGINEERING
MANAGER Weights/Dimensions

JHK Net Weight lb Rotor Weight lb


DATE 18-FEB-22
CERTIFIED Space Heaters: (Operating Conditions)
MWK Voltage V Wattage kW hp Max. Surface Temp. ºC
DATE 18-FEB-22
CONSTRUCTION
AGENCY

DATE
OPERATIONS

DATE
CONTROL NUMBER
VERIFICATION
EDSD

DATE:
BY:
APPROVAL/CERTIFICATION REQUIREMENTS,
THIS INDICATES THAT REV NO ____B_____
OF THIS DRAWING IS COVERED, FOR ALL

BY DRAWING COMPLETION CERTIFICATE


(DCC) NO. ___________________________
REVISION CERTIFICATE

MECHANICAL DATA SHEET FOR COOLING WATER SYSTEMS CHEMICAL


DWG.TYPE PLANT NO. INDEX DRAWING NO. SHT.NO. REV.NO.
INJECTION PACKAGE
JFGP UTILITIES DAT 16
862 U TE-419892-001
JFGP 2 Jafurah Utilities, Sulfur and Interconnecting Systems (Package 3) OF B
JAFURAH SAUDI ARABIA JO / EWO 10-14329-0003 16