You are on page 1of 3

CYP ORT Test Plan

2022.09

1
ORT – On-going Reliability Test Readiness
ORT - Sampling and Test Frequency:
• 1st ORT, when the production through-put volume reaches: 10 units
• ORT – On-going
Sample Reliability
rate: by every 100K Test Readiness
• ORT will also be conducted if there were issues found in production line that requires the need to confirm if
the issues fixed did not affect the reliability of the devices.
ORT Test cases: ORT Planning
10pcs

Power On/Off Power On/Off


Burn-in (40 ℃)
5℃ / 40 ℃ 40℃ / 5 ℃
5pcs
Random 10pcs Random
5pcs
5pcs 5pcs

RJ45/SIM/AC
Power life cycle
Random 5pcs Random 5pcs
10pcs

Random 2pcs Random 2pcs Random 2pcs

Vibration Test ESD Drop Test


2pcs 2pcs 2pcs
2
ORT – Test item
Sample
ID Test Case Test Description Test Criteria Test location
request

ORT-1 Burn-in on 40℃ ENVIRONMENT Test duration: TBD No any issue 10

1. Temp: +5°C with dwell time 30min


1. Normal Power on
Power On/Off with Operating Temperature 2. Device Power On/Off : 10 cycles
ORT-2 2. No reboot issue 5 (Reuse) Hanoi
ranges Indoor 3. Temp: 40°C with dwell time 30min
3. Check LED status
4. Device Power On/Off : 10 cycles
1. Temp: +40°C with dwell time 30min
1. Normal Power on
Power On/Off with Operating Temperature 2. Device Power On/Off : 10 cycles
ORT-3 2. No reboot issue 5 (Reuse) Hanoi
ranges Indoor 3. Temp: 5°C with dwell time 30min
3. Check LED status
4. Device Power On/Off : 10 cycles
SD/SIM card slot insertion and removal 1. Direction: insertion and removal 1. Check SIM slot Push status
ORT-4 NA
durability test 2. Cycle: 10 times 2. Check SIM detect status

1. Direction: insertion and removal 1. Check RJ45 port status


ORT-4 RJ11/45 terminal endurance test 5 (Reuse) Hanoi
2. Cycle: 10 times 2. Check RJ45 port detect status

1. Direction: insertion and removal 1. Check AC port status


ORT-4 Power adapter insertion and removal 5 (Reuse) Hanoi
2. Cycle: 10 times 2. Check AC port detect status
1. Floor: concrete
2. Height: 1.5 feet (0.4572m)
ORT-5 Drop Test No any issue 2 (Reuse) Hanoi
3. Number of drops: 3 top / 3 bottom with 4 side
4. Device: with protect material
1. Contact discharge ; ± 2KV: 1 time/sec; total 10 times
ORT-6 Electrostatic Discharge (ESD) No any issue 2 (Reuse) Hanoi
2. Air discharge ; ± 4KV: 1 time/sec; total 10 times
1. Sine sweep
•Frequency: 5-100-5 Hz ; Level: 0.1g
•Time: 0.1 oct/min (= 90 mins/axis)
2. Random
ORT-7 Vibration Test No any issue 2 (Reuse) Hanoi
•Frequency: 5-100 Hz ; Level: 5-10Hz @+12dB/oct ; 10-
50Hz @0.04m2/sec3 ; 50-100Hz @-12dB/oct ; Total
0.154Grms
•Time: 30 mins/axis