Attrition Improve
Attrition Improve
TECHNOLOGY
VIETNAM
IMPROVEMENT
3.1. Attrition study & improvement action
PN: MEKET42002A
PN: MEOTR42003A PN: MEKET42002A
MEOTR42002A MEOTR42002A
Head Head
3
4 2 Flying
camera
5 1
Vision camera
PCBA Reel set up on feeder
BOT view
3.1. Attrition study & improvement action
► Action: High light by MV2 system when change PON. BA Maint will verify and change shape (vision setting) for
difference part before running (Apply from 5-Oct-22 for model VEGA, LYRA, KING, OUTRUN, LIBRA, GMN)
► Long-term action: DOE the lighting para-metting that combine vision setting of 3 components (W40-2022Y)
3.2. Attrition study & improvement action
pcs
SC222G044B2 SC222G044B2 - Line SC222G044B2 - Line S12
pcs S12 pcs - MD25
300 1000
269
888 900
250 900
28 801
197 59 800
190 800
200
158 162 161 700 700
150 138 133
600 MD23 600
42
180 527 FD12
100 500 MD24 500
72 106 142 FD7
99 135 MD25 400
50 44 88 72 400 801 Total
68 24 Total
300 300
0
200 200
274
100 100
0 0
F03 F04 F06 S10 S12 S14 S15 S17 S18 Total S12 MD25
2. Part SC222G044B2
1. Cause analysis
Turn on “vision processing” function Module 25, detect holder E is stuck,
of P&P machine at module 25 and can’t up-down to pick up component
follow phenomenon
2. Action
- Temporary skip holder E for
running
Apply from 10:20 am 28-Sep-2022
D E F
➔ Result: No happen NG after that
SF14G60C0A0 SF14G60C0A0
pcs pcs
All models happen NG with this part and focus on “Pick up miss” and
“Error parts”
3.3. Attrition study & improvement action
3. Part SF14G60C0A0
➔ Suspect: Nozzle
1. Cause analysis type isn’t suitable,
There are 3 phenomenon: force for pick up
+ Nozzle can’t pick up components component isn’t
+ Pick up shift/tombstone good
+ Drop when moving 0.5mm 0.7mm 0.9mm
➔ It happen for all models, all lines and all
feeder slots
►Investigate Component size: Nozzle size: Φ0.7mm
+ Take out module and check: head, holder, 1.1mm x 0.9mm
feeder, nozzle status => No abnormal
+ Check component and packing => No
abnormal
+ Check component dimension, compare with
nozzle type using => Detect risky points ➔ Proposal idea:
2. Action Trial change
nozzle type from
No Category Items Plan
Φ0.7mm to
1 Trial nozzle 1.0mm for model TTM Week 41, 2022Y Φ1.0mm for
2 Follow and analysis data Week 41+42, 2022Y pick up better
Action 0.8mm 1.0mm
0.9mm
Apply for others models: Beatles,
3 Nov & Dec, 2022Y
Coconut, Queen2, Acadia
Countermea Nozzle size: Φ1.0mm
4 Make STD nozzle for each model From new model Oct-2022Y
sure