ESSJAY TECHNOMEASURE PVT.LTD.

(A House of Calibration Engineering & Allied Services)


D U NO. .I/GALIU+

JAS-ANZ
AN ISO 9001 & OHSAS 18001 CERTIFIED ORGANISATION
Apartment No D 1 3rd Floor, 36, Kantapukur 3rd Bye Lane, Howrah - 711 101
ASURE
TECH Ph.: 033 26670835, 9674756762, website: www.technomeasurenabl.com
E-mail: technomeasure@gmail.com ISO 9001 CERTIFHIED
-- ---F.

Calibration Certificate
Issued to,
M/S. MAA VINDHYAWASINI Certificate No.: 220609JSR/MVE/0138
ENTERPRISES Date: 25.06.2022
Noonidh New Colony, P.O- Jitpur, Dist-Dhanbad-828 309
Jharkhand

Date of Calibration
22.06.2022
Recommended Due Date Page No.
22.06.2023 1 of 1
Date of Received
Description of instrument to be calibrated :22.06.2022
Right Angle (6*"/152mm)
ldentification of Instrument Make: RSI Angle: 90°
Method of calibration VE/RA/01
Details of Standards and :Comparison Method
for calibration
references used
Details of : Reference Gauge Block Set.& Profile
Major Equipments used for Calibration: projector

Description Traceability certificate No &Date Valid Up to Calibration


Slip Gauge Set TENSON, Cr.no:- TI/L/SGS/036/20, Dated: Agency
17.12.2022 TANSON
18.12.2020
Profile projector QSI, Cr.no:- QS/0246/21/10, Dated Instrument
07.10.2021 06.10.2023 QsI

Traceability: Standards used for calibration are traceable to National Standards through NABL accredited
: Temp: 33 +0 °C. Humidity: 50 10 %
laboratory

CALIBRATION RESULTS
T h e average blade length of the tri square is 152.34 mm
The Inside angle ofthe DUC* is 90°10".
T h e outside angle of the DUC* is 89°90*

Overall Flatness of the stem is + 12 um.

Remarks: The DUC* has been Checked over its working range and the results observed are stated above in respect of its
accuracyY.

DUC Device Under Calibration

AUTHORISED SIGNATORY

TARUN DAS
IN CHAREEALIBRATION)
Howrah

Branch Office: Guwahati Jamshedpur Coochbehar


ESSJAY TECHNOMEASURE PVT.LID.
(A House of Calibration Engineering & Allied Services) JAS-ANZ
*i**
AN ISO 9001& OHSAS 18001
CERTIFIED ORGANISATION
Apartment No.: D 1,3rd Floor, 36, Kantapukur 3rd Bye Lane, Howrah 711 101
MEASURE
TECH Ph.: 033 26670835, 9674756762, website : www.technomeasurenabl.com
E-mail technomeasure@gmail.com ISO 9001 CERTIFIED
----

Calibration Certificate
Issued to,
M/S. MAA VINDHYAWASINI ENTERPRISES Certificate No.: 220609JSR/MVE/0139
Noonidh New Colony, P.O- Date: 25.06.2022
Jharkhand Jitpur,Dist-Dhanbad-828 309
Date of Calibration Recommended Due Date
22.06.2022
22.06.2023
Page No.
1 of 1
Date of Received
:22.06.2022
Description of instrument to be calibrated
Right Angle (6"/152mm)
Make: BEHAL Angle: 90°
ldentification of Instrument : VE/RA/02
Method of calibration
: Comparison Method
Details of Standards and references used
for calibration
Reference Gauge Block Set & Profile projector
Details of Major Equipments used for Calibration:

Description Traceability certificate No & Date Valid Up to Calibration


Slip Gauge Set TENSON, Cr.no:- TI/L/SGS/036/20, Dated:
Agency
17.12.2022 TANSON
18.12.2020 Instrument
Profile projector QSI, Cr.no:- QS/0246/21/10, Dated 07.10.2021 06.10.2023 QSI

Traceability: Standards used for calibration are traceable to National Standards through NABL accredited laboratory
:Temp: 33 #0°C. Humidity: 50+10 %

CALIBRATION RESULTS
The average blade length of the tri square is 152.38 mm
The Inside angle ofthe DUC* is 90°10.
The outside angle of the DUC* is 89°90
Overall Flatness of the stem is + 14 um.

Remarks: The DUC* has been Checked over its working range and the results observed are stated above in respect of its
accuracy.

DUC Device Under Calibration

AUTHORISED SIGNATORY
TARUN DAS
IN CHARGEEALIBRATION)
EHowrah
Coochbehar
Branch Office Guwahati Jamshedpur
ESSJAY TECHNOMEASURE PVT.LTD.
OGU NU.. Iwunu

Allied Services)
JAS-ANZ
(A House of Calibration Engineering &
OHSAS 18001 CERTIFIED ORGANISATION
AN ISO 9001 &
Howrah 711 101
ApartmentNo. D 1, 3rd Floor, 36, Kantapukur 3rd Bye Lane,
EASURE Ph.: 033 26670835, 9674756762, website www.technomeasurenabl.com
150 9001 CERTIAIED
E-mail technomeasure@gmail.com

Callbration Certificate

Certificate No.: 220609JSR/MVE/0140


Issued to,
VINDHYAWASINI ENTERPRISES Date: 25.06.2022
M/S. MAA
Noonidh New Colony, P.O- Jitpur,Dist-Dhanbad-828 309
Jharkhand

Date of Calibration Recommended Due Date Page No.


22.06.2023 1 of1
22.06.2022

Date of Received 22.06.2022

Description of instrument to be calibrated Right Angle (9°/228mm)


Angle: - 90
Make: NA
ldentification of Instrument VE/RA/O03
Method of calibration Comparison Method
Details of Standards and references used
:Reference Gauge Block Set. & Profile projector.
for calibration
Details of Major Equipments used for Calibration:

Valid Up to Calibration
Description Traceability certificate No & Date
Agency
Slip Gauge Set TENSON, Cr.no:- TUL/SGS/036/20, Dated 17.122022 TANSON
Instrument
18.12.2020 06.10.2023 QSI
Profile projector QSI, Cr.no:- QSI/0246/21/10, Dated -07.10.2021
Standards used for calibration are traceable to National Standards through NABL accredited laboratory
Traceability:
Temp: 33 +0 °C. Humidity: 50+10 %

CALIBRATION RESULTS
152.37
The average blade length of the tri square is
mm

The Inside angle of the DUC* is 90°10.


The outside angle of the DUC* is 89°90'

Overall Flatness of the stem is t15 um.

its working range and the results observed are stated above in respect of its
Remarks: The DUC* has been Checked
over

accuracy.

DUC Device Under Calibration

AUTHORISED SIGNATORY
iOM TARUN
P A8
Howrah IN CHARGECALIBRATION)

Branch Office Guwahati Jamshedpur Coochbehar


Quality Solutions (India)
ACCREDITED BY NABL (A Constihuent
Board àf dCi, Dept. of thdustral Policy &Promotion, GoM. of Indla)
1s0MEC 17023:2017- Cn
ACCREDITED LABORATORY
Since 1998

CUSTOMER CALIBRATION CERTIFICATE


MS ESSJAY TECHNOMEASURE PVT. LTD.
36, KANTAPÜKUR IRD BYE LANE, FLAT NO. D1, 3RD FLOOR,
Date of Performance
HOWRAH: 711101 WB
Date of Isue 07/10/2021 Certificate No.
Service Request No.
07/10/20211 Service Request Date QSIO246/21/10
QSi/0246/21/10 Total Page 07/10/2021
Page |2
Unit Under Calibration PROFILE PROJECTOR Environment Temperature 20°C+1°C
Calibration Procedure Relative Humidity(%RH) (50+10)%
Visual Inspection
QMP-25(WI-34M)
OK

DETAILS OF UNIT UNDER


CALIBRATION
Make
Range EC. Location Sr. No. D No.
BANBROS X-AXIS-0-150 mm O.001 mnm 0711121
Y-AXIS-0-150 mm 0.001 mm
ANGLE-0-360 1 Sec.
MAGNIFICATION 10X,20X
DETAILS OF STANDARD
EQUIPMENTS USED FOR CALIBRATION
Name
Malie Sr. Na. / 1D. No. Certilcate Na Validity Calibrated By
ANGI Glass mm)
scale MITUTOYO QSIGSD4 TUVGSO14/21 21/09/2023 NABL LAB
ANGLE GAUGE BLOCK MIKRONIX 2043/QS/AG01 Cc-26600
SET KCPAB/19-20548 1S/10/2021 NABL LABT
DigiaCliper PRECISE QSVDCO QSTO190/20/1I CC-2323
02/11/2021 NABL LAB
CC-2717

OBSERVATIONS

ULR NO- CC271721000000245F,


REFER 2nd Page
Format no: FOI(QMP-21)-7.8, Issue
no/ Date :01/01/11/2019 Revision no/ Date: 00/01/11/2019
Employee lD-QS-012

Calibrated by
Shri Ram Dhiman ssued By
(Technical Executive) Ajay Kumar Singh
(TechnicalManager).