Calibration Certificate
Issued to,
M/S. MAA VINDHYAWASINI Certificate No.: 220609JSR/MVE/0138
ENTERPRISES Date: 25.06.2022
Noonidh New Colony, P.O- Jitpur, Dist-Dhanbad-828 309
Jharkhand
Date of Calibration
22.06.2022
Recommended Due Date Page No.
22.06.2023 1 of 1
Date of Received
Description of instrument to be calibrated :22.06.2022
Right Angle (6*"/152mm)
ldentification of Instrument Make: RSI Angle: 90°
Method of calibration VE/RA/01
Details of Standards and :Comparison Method
for calibration
references used
Details of : Reference Gauge Block Set.& Profile
Major Equipments used for Calibration: projector
Traceability: Standards used for calibration are traceable to National Standards through NABL accredited
: Temp: 33 +0 °C. Humidity: 50 10 %
laboratory
CALIBRATION RESULTS
T h e average blade length of the tri square is 152.34 mm
The Inside angle ofthe DUC* is 90°10".
T h e outside angle of the DUC* is 89°90*
Remarks: The DUC* has been Checked over its working range and the results observed are stated above in respect of its
accuracyY.
AUTHORISED SIGNATORY
TARUN DAS
IN CHAREEALIBRATION)
Howrah
Calibration Certificate
Issued to,
M/S. MAA VINDHYAWASINI ENTERPRISES Certificate No.: 220609JSR/MVE/0139
Noonidh New Colony, P.O- Date: 25.06.2022
Jharkhand Jitpur,Dist-Dhanbad-828 309
Date of Calibration Recommended Due Date
22.06.2022
22.06.2023
Page No.
1 of 1
Date of Received
:22.06.2022
Description of instrument to be calibrated
Right Angle (6"/152mm)
Make: BEHAL Angle: 90°
ldentification of Instrument : VE/RA/02
Method of calibration
: Comparison Method
Details of Standards and references used
for calibration
Reference Gauge Block Set & Profile projector
Details of Major Equipments used for Calibration:
Traceability: Standards used for calibration are traceable to National Standards through NABL accredited laboratory
:Temp: 33 #0°C. Humidity: 50+10 %
CALIBRATION RESULTS
The average blade length of the tri square is 152.38 mm
The Inside angle ofthe DUC* is 90°10.
The outside angle of the DUC* is 89°90
Overall Flatness of the stem is + 14 um.
Remarks: The DUC* has been Checked over its working range and the results observed are stated above in respect of its
accuracy.
AUTHORISED SIGNATORY
TARUN DAS
IN CHARGEEALIBRATION)
EHowrah
Coochbehar
Branch Office Guwahati Jamshedpur
ESSJAY TECHNOMEASURE PVT.LTD.
OGU NU.. Iwunu
Allied Services)
JAS-ANZ
(A House of Calibration Engineering &
OHSAS 18001 CERTIFIED ORGANISATION
AN ISO 9001 &
Howrah 711 101
ApartmentNo. D 1, 3rd Floor, 36, Kantapukur 3rd Bye Lane,
EASURE Ph.: 033 26670835, 9674756762, website www.technomeasurenabl.com
150 9001 CERTIAIED
E-mail technomeasure@gmail.com
Callbration Certificate
Valid Up to Calibration
Description Traceability certificate No & Date
Agency
Slip Gauge Set TENSON, Cr.no:- TUL/SGS/036/20, Dated 17.122022 TANSON
Instrument
18.12.2020 06.10.2023 QSI
Profile projector QSI, Cr.no:- QSI/0246/21/10, Dated -07.10.2021
Standards used for calibration are traceable to National Standards through NABL accredited laboratory
Traceability:
Temp: 33 +0 °C. Humidity: 50+10 %
CALIBRATION RESULTS
152.37
The average blade length of the tri square is
mm
its working range and the results observed are stated above in respect of its
Remarks: The DUC* has been Checked
over
accuracy.
AUTHORISED SIGNATORY
iOM TARUN
P A8
Howrah IN CHARGECALIBRATION)
OBSERVATIONS
Calibrated by
Shri Ram Dhiman ssued By
(Technical Executive) Ajay Kumar Singh
(TechnicalManager).