You are on page 1of 1

Howo A7.

Electrical equipment
(3) Malfunction: Unable to flip through the images on the LCD Display Verification procedure:
The gearbox is not in neutral
The image flip button on the screen is damaged, replace the instrument cluster.
(4) Fault indication: Overestimated or underestimated odometer readings.
Verification procedure:
When the instrument cluster is removed, mileage data is stored. If you need to replace the instrument cluster, set up
The code shall be reset according to the parameters of the new instrument cluster.
(5) Malfunction: The instrument cluster illumination is not activated.
Verification procedure:
To illuminate the instrument cluster, a 24V lamp is used. If the voltage of the on-board network is too high, a small -
The baritic lamp may be damaged and will need to be replaced.
(6) Fault indication: Overestimated or underestimated odometer readings.
Verification procedure:
When the instrument cluster is removed, mileage data is stored. If you need to replace the instrument cluster, set up
The code shall be reset according to the parameters of the new instrument cluster.
(7) Fault indication: The instrument cluster illumination is not activated.
Verification procedure:
To illuminate the instrument cluster, a 24V lamp is used. If the voltage of the on-board network is too high, a small -
The baritic lamp may be damaged and will need to be replaced.
(8) Malfunction Sign: Air Conditioning Is Not Working
Verification procedure:
Analysis of the possible cause of the malfunction: After 4 seconds the control system registers the presence of
D+ signal, the J3 relay turns on, its pins are shorted, and the supply voltage through pin 1 of the JPG connector is supplied to the
air conditioner fan. If the D+ signal is unstable, the control system interprets this as start-stop operation of the motor and continues
to keep the J3 relay on, which can lead to a power failure of the conditioner.
Check the D+ voltage output signal on the oscillator and make sure that its parameters are within normal values.
On the engine running, make sure that pins 5 and 6 of the 12-pin JPE connector on the right control unit have a D+ input signal.
Check the fuse F5-3 and relay J3, and then make sure that pin 1 of the JPG connector has an input voltage. Cut the wire connected
to pin 1 of the JPG connector and attach it to pins 3 or 4 of the JPB connector.
Panel.
(9) Malfunction: When the air conditioner is on, the parking lights are on at half the incandescence. After turning on the overall
lighting, the air conditioner stops working.
Verification procedure:
Analysis of the possible cause of the malfunction: The wire of the “mass” of the air conditioning system is disconnected. When you
turn on
of the air conditioner, its power is carried out through a chain of “mass”, connected through the lights of the overall lighting. When
the oversized lights are turned on, the high-level supply voltage appearing on them leads to a cessation of the
supply voltage supply to the air conditioner, which is accompanied by its stopping.
Make sure that the “mass” circuit of the air conditioning control system is reliably connected.