You are on page 1of 3

file

Parameter
Optical Network Tester

4.3

Possess laser ranging port Not Possess laser ranging port


(Top) (Top)
Top view Main view
4

port
VFL

port 4.3
OTDR&LS VFL OTDR&LS OPM
OPM

port
5

LED flashlight LED Charging indicator


5 Laser ranging port(Optional)
Left side Right side
Tracker port
RJ45 Sequence port

Bottom view

Home key
Short press to return
to the main interface
Menu key
Short press to pop up the shortcut menu Return key
Return to the previous menu
ON/OFF key
Short press to start,long press to
prompt to shut down;
After power on, briefly press to
turn on the flashlight function

13:24

13:24
2020/02/14

AUTO Expert

Auto OTDR Expert OTDR Event Map

13:24 OPM
REF
12.00 dBm

Bluetooth VFL Charge indicator


OPM Laser Source VFL

5M
       

RJ45 Sequence RJ45 Length RJ45 Tracker

Optical Loss Test File Management System Settings

Shortcut Menu
4.

Possess laser ranging function


Press the " " icon at the bottom of the screen to enter the Fast Menu
quick operation menu, and press different function icons to Expert

enter the corresponding function interface or realize the AUTO

corresponding operation functions. Auto Test Flashlight VFL

Screen capture:Capture the current interface, the picture will Home File Print Screen

be automatically saved in the instrument, and the file name is


the time when the screenshot is generated. Laser Ranging Power Off Exit

Note:The laser ranging function is optional, and the standard


Not possess laser ranging function
configuration does not have the laser ranging function.
Under the shortcut menu, the laser ranging is grayed out and Fast Menu
cannot be operated. Expert
AUTO

Auto Test Flashlight VFL

Home File Print Screen

Laser Ranging Power Off Exit

Auto
5.

13:24
Auto OTDR: only need to set the wavelength, PASS
other parameters are automatically selected. Curve List Event Map
Settings: enter “Test Setting” / “Pass/Fail” 0 Len:96.150km
Event:
总长 80.001KM 累积 12.32dB 衰减
6.441dB AV.L:0.19dB/km
Link-L: 事件 12
setting interface /dB Auto Test 1550nm 100km 80ns
40.0
Test settings: set the wavelength, IOR and test 36.7 1:1
time 33.3

Pass / Fail settings: 30.0

26.7
Avg. Loss Thre. : set the threshold of the 23.3

average link loss 20.0 1

Event Loss Thre. : set the loss threshold of 16.7 2

13.3
events in the link. If it is greater than this 10.0 3

threshold, it will be judged as fail, otherwise it 6.7

will be pass. 3.3

0.0
Files: open the saved curve data 14.70 29.41 44.11 58.82 73.52 88.22 102.93 117.63

No. Type Dis Loss dB/km Return Total-L


Save: the file is saved in the folder with the 1 48.905km ------ 0.19dB/km 2.35dB 1.25dB/km
name of the same day
Test: start OTDR automatic test Event 1550nm

Settings Files Save Test


Besides 1625/1650nm, pls don’t test online !

Auto OTDR List

13:24
List: the test results are displayed in the form of a list.
PASS
Total length: the total length of the link
Curve List Event Map
Total-L: the total loss of the link
Auto Test 1550nm 8km 80ns
Avg.L: the average loss of the link
Total Length
Total Event: the total number of events, passed Total-L

numbers, failed numbers Avg.L


Total Event Pass Fail
In the event list: 3
3 0
NO.: the order of the current event Dis Loss Total-L Avg.L Return
No. Type
km dB dB dB/km dB
Type: the type of the current event
3-1 50.500 -0.11 0.18 34.73 8.93
Dis: the distance of the current event 3-2 71.486 0.88 0.20 ------ 13.94
Loss: the loss value of the current event 3-3 95.160 ------ 0.19 17.08 18.44
3-4 95.160 ------ 0.19 17.08 18.44
Total-L: the total loss from the start to the current
3-5 95.160 ------ 0.19 17.08 18.44
event point
Avg.L: the average loss value from the start to the
current event
Return: the return loss value of the current event point Event

Setting
设置 文件
Files Save
存储 Test
测试

Expert OTDR 7.

Expert OTDR: set parameters such as wavelength, 13:24

range and pulse width. Curve List Event Map


FastSetting: quickly set the test parameters of 3 Len:95.160km
Event:
总长 80.001KM 累积 12.32dB 衰减
Link-L: 0.23dB/km
6.441dB AV-L: 事件 12
0.19dB/km

OTDR CursorAB Dis:58.400km


A-B 80.001KM Loss:
累积 12.32dB 11.940dB
衰减 AV-L:
0.23dB/km0.19dB/km
事件 12
/dB Auto Test 1550nm 100km 80ns
Measurement mode: OTDR scanning event mode, 40.0

36.7 1:1
AutoTest/RealTest/Avg.Test 33.3 A 34.701km
24.30dB
Wavelength: select the test wavelength of OTDR 30.0
B
93.101km
26.7 12.36dB
Test range: usually choose about 2 times of the 23.3

length of the optical fiber to be tested 20.0 1

16.7
Test pulse width: 3ns ~ 20000ns optional, different 13.3
2

range, the optional pulse width is different 10.0 3

There are five types of events: 6.7

3.3

0.0
14.70 29.41 44.11 58.82 73.52 88.22 102.93 117.63 /km

Auto Test 1550nm

Rising event
100km 80ns

Fast Settings Files Save Test


Settings

Setting
8.
Test Setting: Avg.Time,Wave and Refractice Index are the
13:24
same as those in Auto OTDR.
Refractive Indexx: provided by optical cable or fiber manufac- Test Setting Pass/Fail
turer.It is the key parameter for calculating the distance, and can
not be set arbitrarily. Avg.Time 5s
Unit:select the required unit, there are 3 options for mi/km/kft.
Wave 1550nm
Real Time Test Analyse:Open/Cancel the real Time Test
Analyse function at the end of real-time test Refractive Index (1550nm) 1.468000
Event Loss Threshold: set the loss threshold of connection
point, fusion point in the link that can be tested, between 0.2dB ~ Unit km
30dB, and the default value is 0.2dB. Loss value larger than the
Real Time Test Analyse Open
setting value will be listed in the event list, or it will be ignored.
Reflectance Threshold: set the return loss threshold of the link Event Loss Threshold 0.20dB
reflection events that can be tested, ranging from 10dB to 60dB,
the default value is 40dB. Reflectance Threshold 40.00dB
End Loss Threshold: set the loss threshold after link that can be
End Loss Threshold 10.00dB
tested, ranging from 1dB to 30dB, the default value is 10dB.
Auto Save: Open/Cancel the Auto Save file function at the end of Auto Save Open
real-time test.
OK: save the set parameters OK Default Cancle Test

Default: restore factory settings


9.

13:24
OTDR-File Save Curve List
曲线 列表 Event
事件地图 Map
the【 Save 】 事件: 33 总长:
总长 80.001KM
Event: 累积 12.32dB
Len:95.160km 累积: 衰减 0.23dB/km
18.441dB
Link-L:6.441dB 衰减:
AV-L: 事件 12
0.19dB/km

A-B光标
CursorAB 距离:
Dis:58.400km
A-B 80.001KM 损耗: 11.940dB
Loss:
累积 12.32dB 衰减 衰减:
AV-L:
0.23dB/km0.19dB/km
事件 12
/dB 自动测试
Auto Test 1550nm
1550nm 100km
100km 80ns
80ns
40.0

36.7 1:1
33.3 A 34.701km
24.30dB
30.0
B
93.101km
26.7 12.36dB

23.3

20.0 1

16.7Save file 2

Auto-save function 13.3

10.0 3

6.7
1 2 3 4 5 6 7 8 9 0
3.3

0.0
14.70 29.41 44.11 58.82 73.52 88.22 102.93 117.63 /km
Q W E R T Y U I O P
平均测试
Auto Test
A S D F G H 1550nm
J K L
Z X100km
C V B N M 80ns
Clear

Fast
快速设置
Setting
- < 参数设置
Setting
> 文件
Files
Space Save
保存
Save Exit
测试
Test

10.

13:24
OTDR-File Operation File

【Files】
SD 12345678910215

Head: back to the first page No. File Name Date

Delete: delete the current file or folder 1 0325_003122341.SOR 2020-04-21

Rename: change the name of the current file or folder 2 0325_003122313.SOR 2020-04-21

Open: open the selected file or folder 3 0325_003121231.SOR 2020-04-21

4 0325_003121231.SOR 2020-04-21

5 0325_003321312.SOR 2020-04-21

6 0325_003321312.SOR 2020-04-21

7 0325_003121322.SOR 2020-04-21

8 0325_003131232.SOR 2020-04-21

Page 4-1

Last Page Next Page

Open Delete Rename FirstPage

11.

The function can be operated automatically by 13:24


one key, and the information of the length of the PASS
link, the type of event point and the position of Event Map List
breakpoint can be displayed in a graphical form.
#4:95.160km
The result is clear and easy to understand.
95.160km
The starting point
#3:50.566km
The starting point of the link added #3 Event 3
start
None Event
leading optical fiber in the front 50.566km
Position:95.160km
Descending events, mostly melting points Loss:- - - -
#2:20.986km
Avg-Loss:0.19dB/km
Rising event, caused by the inconsistency Return:17.08dB
20.986km
of refractive index of fiber at both ends Total Loss:18.44dB
#1:10.256km
Connector, such FC/SC/LC connectors
10.256km Len:95.160km
Optical fiber macro bending Event:3
Equipment

Optical splitter
Event 1550nm
End of the link
Settings Files Save Test

Besides 1625/1650nm, pls don’t test online !

12.

The function is used to test the power of optical signal 13:24

and insertion loss of various devices and optoelec- OPM

tronic components. It can identify and measure the


frequency of 270/330/1000/2000Hz optical signal.

-50.00dBm
Wave: switch the working wavelength
Reference: set current power as reference power
CAL: enter the user calibration mode and
calibrate with the standard light source

TWINS: identify the wavelength and frequency of the 1310 nm Rel.Pow: -50.00 dB

tested laser source. This function is used with the twins Lin.Pow: 10.0 nw
function of the laser source Tone.Det: CW
Ref:0.00 dBm
-50~+26dBm: received power>-10dBm
-70~+6dBm: received power>-30dBm

Wave Reference CAL TWINS

13.

13:24
13:24
VFL
VFL

650
Output Mode
nm
650nm OFF
DANGER
DANGER
避免直视激光输出口,激光会对人
眼视网膜造成伤害!

Normal: turn on red light, continuous light Looking directly at laser output
may cause damage to human eyes!
1Hz: red light flashes once in 1 second
2Hz: red light flashes twice in 1 second
Close: turn off red light

Warning Normal 1Hz 2Hz Close


打开 1Hz 2Hz TWINS
Looking directly at laser output may cause damage to human eyes!
打开 1Hz 2Hz 关闭

14.

13:24

Laser Source

Output Mode

1550 nm CW
Open: turn on the laser source
Wave: switch the wavelength, the output

DANGER
wavelength is consistent with OTDR
Mode: switch the modulation frequency of
light source, CW/270/330/1000/2000Hz optional Looking directly at laser output
may cause damage to human eyes!
TWINS: enter the paired output mode. This
function is used with the twins function of
optical power meter

Warning
Open Wave Mode TWINS

Looking directly at laser output may cause damage to human eyes!

Optical Loss Test 15.

13:24
Optical Loss
Test
Used to test the insertion loss of optical
passive components.
The loss test steps are as follows:
1)First connect the LS and opm optical interfac- LS LOSS
es with standard jumpers,Press 【Open】 and
press 【Reference】after the power is stable. 1550 nm <-70 dB
2)Then connect the tested part to LS and opm
optical interfaces with standard jumper, Press OPM Lin.Pow Ref
【Open】, and "relative power" is the insertion
loss of the tested part. -29.86dBm 0.00nm 2dBm

Open Wave Reference Ref-Zero

Tracker 16.

Rj45 Tracker 13:24

Used for Rj45 tracker. After the line-finding function is activat- RJ45 Tracker

ed, the cable being searched is touched by the distal end of the
line-searching, and the sound of continuous “ticking and
ticking” heard.
The equipment can withstand voltage and
prevent burning, and can be directly charged
for line finding. Ethernet switch, router and
other weak current equipment with DC
voltage less than 60V.
Start: open the RJ45 cable tracking function
Analog Mode/Digital Mode: different route
tracking methods Access to left port,
Standard : Digital cable tracker Support live test!

Start Figure Line Finding Exit


The cable tracker port is designated as the upper interface
displayed in yellow. Incorrect connection will cause damage!

RJ45 Sequence 17.

13:24
RJ45 Sequence
Measure the sequence of 8-core wires inside
the network cable. Please connect to the
remote module when measuring.
1

Standard: select different network cable 3


4
standards 5

Test: start cable sequence test 6


7
Exit: exit the cable sequence test and return to 8

the main interface

Warning
Please do not test online! Please access the remote
module before testing!

The cable sequence port is designated as the lower interface


displayed in yellow. Incorrect connection will cause damage! Standard Test Exit

RJ45 Length 18.

13:24

RJ45 Line Length


RJ45 Length test:Test the length of the
network cable.
200m

Standard: select different cable standards 200m


1

Unit: switch different units 2 200m


3
CAL: adjust the test result according to the 4
200m

actual length, and display length = last test 5


200m
6
result × correction 7 200m
8
Test: start cable length test 200m

200m

Warning
Please do not test online!
Please access the remote
module before testing!

The cable length port is designated as the lower interface


Standard Unit CAL Test
displayed in yellow. Incorrect connection will cause damage!

LaserLaser Ranging
Ranging(Optional) 19.

13:24
Laser Range: the maximum test distance is 40 meters Laser Ranging
Mode:Single/Continuous
Reference plane: select a different reference plane
Starting from the bottom of the instrument, the
test length includes the length of the instrument; Mode

Starting from the laser emission port of the Reference plane

instrument, the test length does not include the length


of the instrument; Single 25.658 m
Unit: switch units, with m and ft options
Test: start length test CAUTION
Looking directly at laser output
may cause damage to human eyes!

Unit Test Ref

System
20.
18.

13:24

Brightness: slide the progress bar to adjust the backlight System

brightness
Brightness
Energy conservation: slide the progress bar to set automatic 48%
screen power off without operation for 1-10 minutes Energy Conservation
Auto OFF:slide the progress bar to set the automatic 3min
shutdown time without operation Auto OFF
Date & Time: set the instrument date and time 55min
Sound: turn the touch tone on or off System Operation Settings
Flashlight: turn the flashlight on or off
Date&Time 2021-04-05 08:25
USB connection: connect to the computer after opening and
Beep ON
transfer data
USB Connection OFF
Bluetooth:turn Bluetooth on or off
Bluetooth ON
Language: displays the native language type
Language English
Auto Save: automatically save the curve file after opening
Restore Factory
Restore factory settings: restore default parameter values
Update
Upgrade: software upgrade
Information
Version information: view local information and alarm
records

Faults
Laserand
Laser Solutions
Ranging
Ranging 21.
17.
The description in the
right table is for
reference only. Please
refer to the new
instruction for
detailed usage. In the
process of using the
instrument, if you
have any questions,
you can contact the
instrument supplier.
Output connector of OTDR is damaged

The setting for test range is too small.

The setting for pulse width is too small.

Test curve with poor quality. Increase test pulse width parameter, increase the

event threshold value.

The average loss value of optical fiber The test curve front end with too long tail.

is not accurate.

Laser
Laser Ranging
Ranging
Maintenance 22.

Cleaning of connectors
The optical output interface of this series OTDR is a replaceable universal interface, and the end
face must be kept clean during use. When the instrument fails to test the normal curve or the test result
is not accurate, first consider cleaning the connector.
When cleaning, be sure to turn off OTDR and visible red light fault location function. Screw off the
output port and wipe the connection end face with a special dust-free paper towel or cotton swab
wetted with alcohol.
At the same time, please cover the dust cap after using the instrument, and keep the dust-proof clean
at the same time.
Instrument screen cleaning
The display of this series of optical time domain reflectors is 4.3 inch TFT full view color LCD with
capacitive touch screen. When using, do not click on the LCD with sharp objects, or the LCD screen
may be damaged. When cleaning, clean the LCD screen with soft paper. Do not wipe the LCD screen
with organic solvent, otherwise it may damage the LCD screen.

You might also like