number. 59 in the evaluation of the Technical 2. 87 is the device function number Performance of a Distribution System assigned by ANSI to this relay; according to Philippine Distribution differential protective relay Code (PDC)? Collecting Efficiency 3. What is the device function number for 19. Philippine Energy Plant is the overall overcurrent relay 51 energy program formulated and 4. Instantaneous overcurrent relay 50 updated yearly by the DOE, submitted 5. What is the equivalent IEEE device to the congress pursuant to RA 7638 function number for directional power 20. The lighting load for a dwelling relay? 32 expressed in terms of a unit load in volt 6. IEEE under voltage . 27 ampere per square meter must be at 7. The lowest KAIC available commercially least 24. for miniature circuit breakers is 5 21. . A 4-way switch controls a lamp from 3 8. Receptacle outlets shall be located different locations. above, but not more than 500 mm 22. . The current-carrying capacity of a above the countertop. copper wire having twice the diameter 9. In dwelling units, hallways of 3 m or of another copper wire is 4 times as more in length shall have at least one great receptacle outlet. 23. Which of the following is not a standard 10. The surge impedance of an branch circuit among rating? 25A underground cable is around 25 Ω 24. the IEEE device function number 50 11. What is the minimum clearance instantaneous overcurrent relay between the recessed incandescent 25. The type of ac distribution system fixture and the nearest point of a commonly used to supply both light and storage space of a closet? 150 mm power is the three phase wye system 12. What is the maximum allowable voltage with neutral wire drop for lighting circuit? 3% 26. What governs the minimum safety 13. What is the maximum allowable voltage requirement in the Philippines for drop for feeder? 5% distribution and grid? PEC 14. Which of the following is the basis of standards of electrical wiring installation in the Philippines? Philippine Electrical Code 15. In dwelling units with a hallway of 3m or more in length, at least how many receptacle outlet/s shall be installed? 16. When installing two grounding electrodes, the minimum distance between them is 1800 mm 17. An act to ensure and accelerate the total electrification of the Philippines, Electric Power Industry Reform Act also known as the EPIRA law of 2001 RA 9136. 27. What instrument measures the insulation of a powerline? Megger’ 28. Branch circuit larger than 50 amperes shall only supply non- lighting outlet load. 29. What does PEMC in EPIRA stands for Philippine Energy Market Corporation 30. PD 269 – National Electrification Administration