GENERAL NOTES

A A (1) THIS DRAWING IS THE PROPERTY OF :


ORBIT OFFICE , DOHA, QATAR. IT IS NOT ALLOWED
TO REPRODUCE ITS CONTENTS IN ANY FORM EXCEPT FOR
THE PURPOSE FOR WHICH IT IS INTENDED.
SAD(350X200) (2) THIS DRAWING IS NOT TO BE SCALED. WRITTEN DIMENSIONS
(183 L/S) FFL +19.876 m
SSL +19.776 m
EXISTING FCU-01 (3)
ONLY ARE TO BE CONSIDERED.
ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION
1-SCD 600X600 MM, OF THE ENGINEER AND RESOLVED BEFORE COMMENCEMENT
OF ANY WORK.
EXISTING FCU-01
SAD(350X350)
(396 L/S)
NECK 150X150 MM
FFL +19.876 m
SAD(350X200)
(183 L/S)
SSL +19.776 m SAD(200X100)
(30 L/S)
30 L/S PER EACH

8950

8950
SAD(400X300)
(366 L/S)
SAD(350X200)
(183 L/S)
SAD(350X200)
(183 L/S)
SAD(550X500)
(1130 L/S)
EXISTING FCU-01
6-SCD 600X600 MM,
SAD(400X300)
(366 L/S)
NECK 300X300 MM TECHNICAL SPECIFICATIONS OF THERMAL
183 L/S PER EACH INSULATION FOR BUILDINGS
(THERMAL INSULATION) HEAT TRANSFER COEFFICIENT
FOR SURFACES AND OUT WALLS
FFL +19.876 m HEAT TRANSFER COEFFICIENT HEAT TRANSFER COEFFICIENT
SSL +19.776 m
SAD(350X200) FOR OUT WALLS FOR SURFACES

B SAD(350X200)
(183 L/S)
(183 L/S)
B 0.568 W / m² °c 0.437 W / m² °c

0.100 Btu / Hft² °F 0.077 Btu / Hft² °F

(THERMAL INSULATION) WINDOWS TO WALL RATIO


SAD(350X250) FOR HEAT TRANSFER AND SHADING COEFFICIENT
(232 L/S)
EXISTING FCU-02 WINDOWS TO WALL HEAT TRANSFER CO. WINDOWS SHADING
5300

5300

RATIO (WWR) W / m² °c (Btu / Hft2hF) COEFFICIENT (SC)


SAD(350X250)
25000

25000
(232 L/S) 5 - 40 % 3.30 (0.58) 0.40

MORE THAN %40 2.10 (0.36) 0.35


FFL +19.876 m
SAD(400X350) SSL +19.776 m
SAD(500X400) SAD(350X250)
(464 L/S) (696 L/S) (232 L/S)

C SAD(1200X550)
(2560 L/S)
C
SAD(750X450)
(1392 L/S)

SAD(350X250) SAD(450X300) SAD(350X250) 0 2020.XXX ISSUE FOR APPROVAL EAS


(232 L/S) (464 L/S) (232 L/S)

EXISTING FCU-02 REV.


QR-Code
DATE
MUNICIPALITY STAMP
DESCRIPTION BY

SAD(500X400) 11-SCD 600X600 MM,


( 696 L/S)
NECK 300X300 MM
232 L/S PER EACH
10750

10750

SAD(350X250) SAD(450X300) SAD(350X250)


(232 L/S) (464 L/S) (232 L/S)

Enquiry No. : xx / xxxx / xx Application No : xx / xxxx / xx


CONSULTANT REG. No : 387/L GRADE : C CONSULTANT REG. No : 1664 GRADE : A
FFL +19.876 m CONSULTANT STAMP & SIGNATURE : SUB-CONSULTANT STAMP & SIGNATURE :
SSL +19.776 m

D D TECHNIQAL MANAGER :

REGISTRATION No. :

CONSULTANT
A.ESSMAT
1664
TECHNIQAL MANAGER

REGISTRATION No :
A.ESSMAT
1664

ENTRANCE

Doha, State of Qatar : D-Ring Road TEL : +974 33199303


E-mail. : Info@orbitconsults.com +974 77025839
+974 33399442

10000
FCU SCHEDULE PROJECT

10240 UNIT NO. AIR FAN DATA COOLING COIL DATA PROPOSED FIT-OUT WORK FOR
FLOW EXTERNAL
QUANTITY SERVICE MOTOR ELECTRICAL TOTAL SENSIBLE EDGE ENGG
RATE STATIC
POWER SERVICE LOAD LOAD SHOWROOM NO.(SYS070)
PRESSURE IN GROUND & MEZZANINE FLOOR LEVEL
L/S PA KW V/PH/HZ KW KW AT BUILDING TYPE 5 BLOCK 22
AT BARWA COMMERCIAL AVENUE
102 103 104 FCU-01 1 DWG 1130 100 1.034 415/3/50 16.2 13.4 OWNER:

-----
FCU-02 1 DWG 2560 100 2.81 415/3/50 34 28.9 LOCATION:
AL-SADD, QATAR
PIN NO:
------------
CLIENT:
EDGE ENGG
DATE: JOB NO.:
23-11-2023 C314/P2
TITLE:

HVAC SYSTEM
NOTE: GROUND FLOOR PLAN
01 GROUND FLOOR PLAN 1. TOTAL&EXTTERNAL STATIC PRESSURE /MOTOR POWER TO BE VARIFIED BY CONTRACTOR UPON SELECTION OF ACTUAL UNIT.
2. UNIT TO BE COMPLETE WITH MIXING BOX WITH DAMPER & ACTUATOR. SECTION FOR PREFILTER AND FINAL FILTER.
DRAWING NO.:
AC-01 A0
SCALE:
1:50
AC-01
SCALE: 1:50 3. ACTUAL AIRFLOW INDICATED AT SEA LEVEL. TYPICAL FOR ALL FLOW RATES SHOWN IN THE SCHEDULE DRAWN BY:
HAMSA
DESIGNED BY: CHECKED BY:

CAD FILE: HAMSA M.GOMAA

REVISION REGISTRATION No. : REGISTRATION No. :