DESIGN OF STRIP FOOTING

Total column load = 525.6 kN


Pressure under footing = 525.6 kN/14.65m = 35.9kN

Moment Reinforcement
Max. moment, M = 38kNm
Mu = 38 x 1.5 = 57kNm

d = 350 – 40 - 6 = 304mm
d’ = 30mm
M 57 x 106
k = 2 = = 0.034 < 0.156
fcu .b.d 30 x 600 x 3042
k 0.034
z = d[0.5 + (√0.25 - )] = d[0.5 + √(0.25 - )] = 0.96d > 0.95d
0.9 0.9
M 57 x 106
As = = = 411mm2
0.95 . fy. z (0.95 x 500 x 0.96 x 304)

Provide 6T12 = 678 mm2 ˃ 411mm2


Shear
Max shear near support, V = 72kN 100As 100 x 678
Vu = 72 x 1.5 = 108kN = = 0.37
bd 600 x 304
V 108 x 103
v = = = 0.59 N/mm2 fcu 30
bd 600 x 304 = = 1.2
1 1 1 25 25
100As 3 f 3 400
( ) x ( cu ) x ( )4
bd 25 d
vc = 0.79 x 400 400
1.25 = = 1.32
1 1 1 d 304
0.373 x 1.23 x 1.324
= 0.79 x
1.25

= 0.516 N/mm2

0.4bv sv
A sv ≥
0.95. fyv

Provide 2T10 – 250 c/c

A sv = 2 x 2 x 78.5mm2 = 314 mm2

0.4bv sv 0.4 x 600 x250


= = 126 mm2
0.95. fyv 0.95 x 500
≤ 314 mm2 – OK