You are on page 1of 3

TEST REPORT

CLIENT NAME : UNITED E & P PTE LTD


ADDRESS : 23 FIRST LOK YANG ROAD
SINGAPORE 629733

ATTENTION TO : MR. MUTHUSAMY ALAGAPPAN


TEL NO : 6265 2525
FAX NO : -
ACCOUNT : UNITED E & P PTE LTD
CHARGEABLE TO

PROJECT CODE : PT05510


PROJECT TITLE : TR358 - ROAD MAINTENANCE CONTRACT FOR SOUTH WEST
SECTOR

LOCATION : WSO-00353 CENTRAL BLVD (LP1 TO 4)


TESTED FOR : CHUAN LIM CO (PTE) LTD - UNITED E&P JOINT VENTURE

SUBJECT : COMPRESSIVE STRENGTH OF CORES


TEST STANDARDS : BS EN 12390-3: 2019 (MODIFIED)

JOB REF. : T23-07129


SAMPLE TYPE : SEMIRIGID CONCRETE CORE - 45MM DIAMETER
CLIENT SAMPLE REF : LANE 2
QUANTITY : 3 NOS.

DATE CAST : 30-Jun-2022


DATE RECEIVED : 22-Mar-2023
DATE OF TEST : 27-Mar-2023
DATE OF REPORT : 01-Apr-2023

TOTAL PAGES : 3 (INCLUDING COVER PAGE)


ANNEX A : PHOTOS OF TEST SPECIMENS
JOB REF: T23-07129
Page 2 of 2
TEST RESULTS :
COMPRESSIVE STRENGTH OF CORES - BS EN 12390-3: 2019 (MODIFIED)

SAMPLE REFERENCE

REFERENCE
LANE 2 - 1 LANE 2 - 2 LANE 2 - 3

Condition as received Satisfactory Satisfactory Satisfactory

Method used for sample preparation Cutting & Grinding

Storage condition Air Dried

Test condition Air Dried

Date test 27-Mar-23

Average length of prepared specimen


53.00 46.00 51.00
(mm)

Average core diameter (mm) 44.00 43.00 44.00

Mass (kg) 0.1872 0.1617 0.1840

Apparent density (kg/m3) 2320 2420 2370

Maximum load (kN) 14.9 14.6 14.7

Core compressive strength (N/mm2) 9.8 10.1 9.7

PREPARED BY: APPROVED BY:

CHAN LEE WEI WEE CHIP KAI


Engineer Civils Manager
DID: (65) 6362 9736 DID: (65) 6362 9730
Email: Leewei.Chan@element.com Email: Chipkai.Wee@element.com
JOB REF: T23-07129

ANNEX A
PHOTOS OF TEST SPECIMENS

LANE 2 - 1

LANE 2 - 2

LANE 2 - 3