Professional Documents
Culture Documents
Arcode Operations.V1 50.en
Arcode Operations.V1 50.en
Arcode Operations.V1 50.en
50
ARCODE
INTEGRATED ELEVATOR CONTROLLER
FOR TRACTION LIFTS
OPERATIONS
Arcode Operations V1.50
This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all
of the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the right
to make changes and improvements to any of the products described in this document without prior notice.
Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
Arcode Operations V1.50
Table of Content
1. To copy the firmware to the AREM SD card ........................................................................................................................ 1
2. To update Arcode .................................................................................................................................................................. 1
3. To access the Identification Code for Arcode PUK Code ..................................................................................................... 1
4. To save the Parameters to SLOT ........................................................................................................................................... 2
5. To install the Parameters from SLOT .................................................................................................................................... 2
6. To activate and install PLC module....................................................................................................................................... 2
7. To return the parameters to a previous state .......................................................................................................................... 3
8. To return to the factory settings ............................................................................................................................................. 3
9. To make fast access to a parameter with the parameter code ................................................................................................ 4
10. To change the contact type of an input/output signal ........................................................................................................ 4
11. To assign a signal to a specific floor ................................................................................................................................. 5
12. To make a pit reset with the bottom floor LOP button ...................................................................................................... 6
Arcode Operations V1.50
2. To update Arcode
Tools → Firmware Update;
The firmware on the top is the latest firmware. After selecting, press ENTER to start update.
*When the password for the Tools menu got forgotten, the ID number must be shared with the Technical Support Department,
so they can send you the PUK code which is needed to see your present password or for changing it under “Device Parameters”.
Arcode Operations V1.50
When a change is applied to the system settings or parameters and if because of any reason you want to return to a previous state
of the system, before change apply you can create a SLOT file where every setting and parameter is saved.
Or when you need to transfer all the settings and parameters to the same class of Arcode for replacement, you can create a SLOT
file and install it to the new Arcode.
And, when technical support is needed, the Technical Support Department can ask you for the SLOT file in order to analyze
your systems settings and parameters.
After a change is applied to the systems settings or parameters and if something goes wrong or not in the right direction needed,
the previous status can be reinstalled with the SLOT file. After selecting the SLOT file which has been saved before change
application, press enter to reinstall. Or if for some reason Arcode needs to be replaced with an Arcode of the same class, simply
install this SLOT file when you install the new Arcode for transferring the settings and parameters in a fast way.
PLC modules are needed when a special function is requested that cannot be done with standard Arcode parameters.
If you make changes to any setting or parameter in the Arcode system, Arcode maintains a record for each change you make. In
this way after making changes if you encounter a problem with the parameters you can return the system to a previous state even
if you did not save the parameters as a SLOT file. These records are kept under the “backup” folder in the AREM SD card. These
records are created after the changes are saved. This way you can switch/return/restore to an older state if you experience a
problem.
We return to the factory settings from this menu. After resetting to the factory settings, every parameter and setting is deleted,
so a new installation is required. When it is required, we recommend returning to factory defaults when there is a malfunction in
the system because of anomaly in the parameters. The Arcode EPROM completely erases and reloads the default information
on the EPROM.
The following screen gives you two options for returning to the factory settings. Back to factory settings as a synchronous or
asynchronous motor. Whichever of them you choose, the device parameters are preset for you according to the motor type, so
you do not have to adjust specific parameters.
When you are in the “Device Parameter” menu, press the “F3” button. After pressing, a pop-up screen will open, where you can
enter the parameter code. After entering the parameter code with the cursor buttons, press the “Enter” button. After pressing, the
related parameter will be directly shown.
All the parameters in the “Device Parameters” menu, has a specific parameter code. These codes are not shown on the AREM
tool when you are in the menu. For example, when you are reading an Arcode manual and you see there a code of a parameter
or you get this information ARKEL Technical Support you can fast access with this code.
All codes can be check from the “Arcode Parameter Editor” program.
Important to note is that not all Input / Output signals has the option to select the contact type. Signals which contact type cannot
be selected works as a NO contact.
Important to note is that not all Input / Output signals has the option to be assigned to a specific floor. The signals which has this
option has a “*” sign. When a signal with a “*” signal is not assigned to a specific floor, then the “*” sign means that it is assigned
to all floors.
12. To make a pit reset with the bottom floor LOP button
This function was added to the Arcode firmware 19120900 or later.
So, in order to have this function in the system, make sure that the latest Arcode software is installed.
If not, please update the system. For this, refer to the subject “To update Arcode”.
To make pit reset, you should press bottom floor LOP button 3 times at short intervals and repeat it 3 times.
Arcode Operations V1.50
Important to note is that this reset function will not work for elevators with group control (duplex etc.).
Also important to note that there is no special parameter setting required to enable/disable the reset function. It is ready to be
used.
After the LOP reset is done successfully, a confirmation can be seen by the LOP LED lighting for 5 seconds.