You are on page 1of 147

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK

DIST. LABORATORY, AHMEDNAGAR


TEST DATA SHEET:DCASA-07

JOB NO. AHA/18-19/ 488 / PW/SNR


NAME OF DIVISION Public Work Divi. Sangamner
NAME OF SUBDIVISION P.W.SubDivision Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE 10 mm
DATE OF SAMPLE 9/24/2018
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 13679 gm (IS:383 Tab.2)

DATE OF TESTING 6/27/2018

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 0 0.00 0.00 100.00 100%
3 10 mm 9465 69.19 69.19 30.81 0-45%
4 4.75 mm 4125 30.16 99.35 0.65 0-10%
5 Pan 89 0.65 100.00 0
Total 13679 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING
WT. OF SAMPLE TAKEN gm

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 33.9 W1
2 50 mm 40 mm W2 27 W2
3 40 mm 25 mm W3 19.5 W3
4 25 mm 20 mm W4 13.5 W4
5 20 mm 16 mm W5 10.8 W5
6 16 mm 12.5 mm W6 8.55 W6
7 12.5 mm 10 mm W7 6.75 W7
8 10 mm 6.3mm W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari (R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/18-19/ 488 / PW/SNR


NAME OF DIVISION Public Work Divi. Sangamner
NAME OF SUBDIVISION P.W.SubDivision Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/24/2018

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 43278

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2178 2239
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in water


3
in gm
W3=W1-W2 1478 1539

Weight of saturated dry aggregate in


4
air in gm
W4 2251 2332

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 773 793

Weight of Oven dry aggregate in air in


6
gm
W6 2196 2278

7 Sp. Gravity W6/W5 2.84 2.87

8 Water Absorption (W4-W6)/W6 2.50% 2.37%

9 Average Sp. Gravity 2.86

10 Average Water Absorption 2.44%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA/18-19/ 488 / PW/SNR
NAME OF DIVISION Public Work Divi. Sangamner
NAME OF SUBDIVISION P.W.SubDivision Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/24/2018
DATE OF TESTING 43278

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
43 44
3 Weight retained on 2.36mm IS sieve after
15 blows in gm W3
297 299
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
12.65% 12.83%
(W2/W1)x100
6 Average Impact Value% age
12.74%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2891 2897
2 Weight of fines passing through 2.36mm
IS sieve in gm 356 356
W2
3 Weight retained on 2.36mm IS sieve in
gm 2535 2516
W3
4 Weight of sample in gm
W2+W3
2891 2872
5 Aggregate Crushing Value in % age
12.31% 12.29%
(W2/W1)x100
6 Average Crushing Value in % age
12.30%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/18-19/ 488 / PW/SNR LAB./NO./SNR:- DATE:-
NAME OF DIVISION P.W.SubDivision Sangamner
NAME OF SUBDIVISION P.W.Sub Division Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/24/2018
DATE OF TESTING 9/24/2018

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%

20 MM 100.00 100%

1 12 mm Metal 10 MM 30.81 0-45%

4.75 MM 0.65 0-10%

Pan 0.00 0

TEST RESULTS OF COARSE AGGREGATES

Result Obtained
Sr. No. Type of Test Result Specified for WBM Remark
20 MM METAL Trap Laterite

1 Flakiness Index (Not more than) 15%

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANE:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub. DivisiKarjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ K
1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Gray Blakish Rubble.
DATE OF REC. OF SAMPLE 9/16/2019
DATE OF TESTING 01/02/2019 to 04/02/2016

TEST RESULTS OF BUILDING STONE/RUBBLE

% Water Absorption Apparent Compressive Strength (N/sqmm) Impact Value(%) Crushing Value(%)
Sourse &
Sr.No. Specific
Other Details
Gravity
Determ
Specified Determined Specified Determined Specified Specified Determined
ined
Vide Std.
Specification
Gray Blakish
1 Clause A 4.41 2.87 Vide IS 1597 Part-1 1967 40.00N/mm2 42.50 Max.30% -------- Max.30%
Rubble. 8.1Not more
than 5%

Note :-The test result based on samples received in the Laboratory


TESTED BY S.G. Kokate (L.A.)
CHECKED BY U.A. Borude (A.E.-2) Assist.Reaserch Officer,
Equipment used :- CTM Machine. Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
on road MDR 101 @ Km

Remarks
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat
Dist-Ahmednagar.
TYPE OF SAMPLE :-Rubble
DATE OF SAMPLE 9/16/2019
DATE OF TESTING 01/02/2019 to 04/02/2016

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

Sr.No. Particular Trial-1 Trial-2


Weight of saturated dry aggregate in air
1 in gm(Passing through 20mm sieve & B 1162 1184
retained on 10mm sieve )
Quantity of water added in 1000ml jar
2 containing the test pieces C 611 605
Weight of Oven dry aggregate in gm
3 A 1112 1135

4 Apperant Sp. Gravity A/(1000-C) 2.86 2.87


5 Water Absorption (B-A)/A x 100 4.496 4.317
6 Average Sp. Gravity 2.87
7 Average Water Absorption 4.41

CRUSHING STRENGTH OF BUILDING STONE

Sr .No. Particular Trial-1 Trial-2

1 Identificaton Mark ………… …………

2 Size of specimen 100x100x100 100x100x100

3 C/S Area perpendicular to load sqmm 10000.00 10000.00

4 Crushing Load in (kN) 410.00 420.00

5 Crushing Strength (N/sqmm) 41.00 42.00

6 Average Crushing Strength (N/sqmm) 41.50

7 Specified As Per I.S. 40.00 N/MM2


TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY U.A. Borude (A.E.-2) Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 5/17/2019
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.449 540 24.00

2 A-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.447 550 24.44 24.44 23.56

3 A-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.441 560 24.89

4 A-2 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.451 550 24.44

5 A-2 M-20 1/9/2019 5/17/2019 128 149X150X150 22350 8.458 540 24.11 24.33 23.56

6 A-2 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.448 550 24.44

Reference I.S. 516-1999 CL.5.5. Assist.Reaserch Officer,


TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Compressive Strength of C.C.Cubes


Above 700
Cross Average Reqd.
Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 B-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.462 560 24.89

2 B-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.459 550 24.44 24.74 23.56

3 B-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 8.457 560 24.89

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 5/17/2019
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 C-1 M-15 8/28/2018 9/19/2018 22 150x150x150 22500 8.441 330 14.67

2 C-1 M-15 8/28/2018 9/19/2018 22 150x150x150 22500 8.452 340 15.11 15.11 14.29

3 C-1 M-15 8/28/2018 9/19/2018 22 150x150x150 22500 8.458 350 15.56

4 C-2 M-15 9/6/2018 9/19/2018 13 150x150x150 22500 8.462 280 12.44

5 C-2 M-15 9/6/2018 9/19/2018 13 150x150x150 22500 8.454 300 13.33 12.89 12.30

6 C-2 M-15 9/6/2018 9/19/2018 13 150x150x150 22500 8.459 290 12.89

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 9/10/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-15 9/11/2018 9/19/2018 8 150x150x150 22500 8.447 250 11.11

2 D-1 M-15 9/11/2018 9/19/2018 8 150x150x150 22500 8.457 240 10.67 11.11 10.50

3 D-1 M-15 9/11/2018 9/19/2018 8 150x150x150 22500 8.442 260 11.56

Reference I.S. 516-1999 CL.5.5.

S.G. Kokate( L.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Y.R. Chaudhari (R.A.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/10/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.456 490 21.78

2 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.461 480 21.33 21.63 21.00

3 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.462 490 21.78

4 E-2 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.469 510 22.67

5 E-2 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.458 500 22.22 22.07 21.00

6 E-2 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.452 480 21.33

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 9/10/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.451 520 23.11

2 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.459 500 22.22 22.22 21.00

3 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.456 480 21.33

4 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.461 490 21.78

5 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.458 480 21.33 21.93 21.00

6 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.454 510 22.67

Reference I.S. 516-1999 CL.5.5.

S.G. Kokate( L.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Y.R. Chaudhari (R.A.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/10/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 F-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.458 490 21.78

2 F-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.457 510 22.67 21.93 21.00

3 F-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 8.465 480 21.33

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm
TYPE OF SAMPLE :-Con. Cubes
DATE OF RECEIPT OF SAMPLE 9/10/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 G-1 M-20 6/14/2018 8/1/2018 48 150x150x150 22500 8.456 620 27.56

2 G-1 M-20 6/14/2018 8/1/2018 48 150x150x150 22500 8.462 600 26.67 27.11 26.25

3 G-1 M-20 6/14/2018 8/1/2018 48 150x150x150 22500 8.468 610 27.11

4 G-1 M-20 6/19/2018 8/1/2018 43 150x150x150 22500 8.458 590 26.22

5 G-1 M-20 6/19/2018 8/1/2018 43 150x150x150 22500 8.456 600 26.67 26.67 26.00

6 G-1 M-20 6/19/2018 8/1/2018 43 150x150x150 22500 8.462 610 27.11

Reference I.S. 516-1999 CL.5.5.

S.G. Kokate( L.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Y.R. Chaudhari (R.A.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/10/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-20 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-20 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 17.00 q

3 A-3 M-20 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-20 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-20 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 18.00 r

6 B-3 M-20 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 9/10/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/10/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 9/10/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/10/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 9/10/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.10

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 23.10

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

S.G. Kokate( L.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Y.R. Chaudhari (R.A.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 5/17/2019
Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 540 24.00

2 A-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 550 24.44 24.44 23.56

3 A-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 560 24.89

4 A-2 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 550 24.44

5 A-2 M-20 1/9/2019 5/17/2019 128 149X150X150 22350 540 24.11 24.33 23.56

6 A-2 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 550 24.44

Reference I.S. 516-1999 CL.5.5. Assist.Reaserch Officer,


TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 B-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 560 24.89

2 B-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 550 24.44 24.74 23.56

3 B-1 M-20 1/9/2019 5/17/2019 128 150x150x150 22500 560 24.89

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 5/17/2019


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 C-1 M-15 8/28/2018 9/19/2018 22 150x150x150 22500 330 14.67

2 C-1 M-15 8/28/2018 9/19/2018 22 150x150x150 22500 340 15.11 15.11 14.29

3 C-1 M-15 8/28/2018 9/19/2018 22 150x150x150 22500 350 15.56

4 C-2 M-15 9/6/2018 9/19/2018 13 150x150x150 22500 280 12.44

5 C-2 M-15 9/6/2018 9/19/2018 13 150x150x150 22500 300 13.33 12.89 12.30

6 C-2 M-15 9/6/2018 9/19/2018 13 150x150x150 22500 290 12.89

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

DIST. LABORATORY, AHMEDNAGAR


JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 D-1 M-15 9/11/2018 9/19/2018 8 150x150x150 22500 250 11.11

2 D-1 M-15 9/11/2018 9/19/2018 8 150x150x150 22500 240 10.67 11.11 10.50

3 D-1 M-15 9/11/2018 9/19/2018 8 150x150x150 22500 260 11.56

4 D-2 M-15 7/25/2018 9/11/2018 48 150x150x150 22500 490 21.78

5 D-2 M-15 7/25/2018 9/11/2018 48 150x150x150 22500 500 22.22 22.07 21.00

6 D-2 M-15 7/25/2018 9/11/2018 48 150x150x150 22500 500 22.22

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

DIST. LABORATORY, AHMEDNAGAR


JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 5/17/2019


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 490 21.78

2 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 480 21.33 21.63 21.00

3 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 490 21.78

4 E-2 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 510 22.67

5 E-2 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 500 22.22 22.07 21.00

6 E-2 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 480 21.33


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 520 23.11

2 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 500 22.22 22.22 21.00

3 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 480 21.33

4 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 490 21.78

5 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 480 21.33 21.93 21.00

6 E-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 510 22.67

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

DIST. LABORATORY, AHMEDNAGAR


JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 5/17/2019


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 F-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 490 21.78

2 F-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 510 22.67 21.93 21.00

3 F-1 M-20 7/25/2018 9/11/2018 48 150x150x150 22500 480 21.33

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 G-1 M-20 6/14/2018 8/1/2018 48 150x150x150 22500 620 27.56

2 G-1 M-20 6/14/2018 8/1/2018 48 150x150x150 22500 600 26.67 27.11 26.25 0

3 G-1 M-20 6/14/2018 8/1/2018 48 150x150x150 22500 610 27.11

4 G-1 M-20 6/19/2018 8/1/2018 43 150x150x150 22500 590 26.22

5 G-1 M-20 6/19/2018 8/1/2018 43 150x150x150 22500 600 26.67 26.67 26.00 0

6 G-1 M-20 6/19/2018 8/1/2018 43 150x150x150 22500 610 27.11

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

DIST. LABORATORY, AHMEDNAGAR


JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- 0
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 5/17/2019


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-20 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-20 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 17.00 q

3 A-3 M-20 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 B-1 M-20 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-20 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 18.00 r

6 B-3 M-20 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 5/17/2019


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 22.00 v
22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 24.00 x
24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 5/17/2019


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09


4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 5/17/2019

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.10 0

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09


4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 23.10 0

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. DivisionKarjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8
Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Ceramic Tiles
DATE OF RECEIPT OF SAMPLE 5/17/2019
DATE OF TESTING 17/05/2019 to 20/05/2019

Testing of Ceramic Tiles (Water Absorption Test)

Sr. No.Identification Size/Dimensio Wt. of Wt. of oven Wt. of water % water Av. % Water
Mark soaked tile dried tile absorbed absorbed absorbed

1 2 3 4 5 6 7 8

1 Cera .Tiles 300x450x10 4653 4633 20 0.43

2 Cera .Tiles 300x450x10 4566 4545 21 0.46

3 Cera .Tiles 300x450x10 4755 4736 19 0.40 0.42

4 Cera .Tiles 300x450x10 4623 4602 21 0.46

5 Cera .Tiles 300x450x10 4703 4689 14 0.30

6 Cera .Tiles 300x450x10 4556 4536 20 0.44

Testing of Ceramic Tiles (Modulus of Rupture Test)

Size/Dimension (mm)
Modulus Of
Specified
Identification Corrected Load Rupture
Sr. No. Sample No.1 Peak Load (N) Limit
Mark (N) (N/Sqmm)=3
Length Breadth Thickness (N/Sqmm)
FL/2bxhxh

1 2 3 4 5 6 7 8 9 10

1 Cera .Tiles 300 450 10 1962 1962 36.30

2 Cera .Tiles 300 450 10 2001 2001 37.02

3 Cera .Tiles 300 450 10 2121 2121 39.24


1 35.00
4 Cera .Tiles 300 450 10 2201 2201 40.72

5 Cera .Tiles 300 450 10 1989 1989 36.80

6 Cera .Tiles 300 450 10 1988 1988 36.78

Average 37.81

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari (R.A.) Assist.Reaserch Officer,

Vigilance & Quality Control(P.W.),


12.47603306
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8
Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Ceramic Tiles
DATE OF RECEIPT OF SAMPLE 5/17/2019
DATE OF TESTING 17/05/2019 to 20/05/2019

Test Results of Ceramic Tiles


(Water Absorption)

Size/Dimension (Modulus of Rupture)


Sr. No. Mark/Colour
(mm) Determined Average Specified Determined Average (N/sqmm) Specified (N/sqmm)

(1) (2) (3) (4) (5) (6) (4) (5) (6)


1 Cera .Tiles 300x450x10 0.43 36.30
2 Cera .Tiles 300x450x10 0.46 Less Than 37.02
3 Cera .Tiles 300x450x10 0.40 0.42 0.50 39.24 37.81 35.00

4 Cera .Tiles 300x450x10 0.46 40.72

5 Cera .Tiles 300x450x10 0.30 36.80


6 Cera .Tiles 300x450x10 0.44 36.78

TESTED BY S.G. Kokate (L.A.)

CHECKED BY Y.R. Chaudhari (R.A.) ASSISTANT RESEARCE OFFICER


VIGILANCE & QUALITY CONTROL
DISTRICT LABORATORY

ASSISTANT RESEARCE OFFICER ASSISTANT RESEARCE OFFICER ASSISTANT R

VIGILANCE & QUALITY CONTROL VIGILANCE & QUALITY CONTROL VIGILANCE & Q

DISTRICT LABORATORY DISTRICT LABORATORY DISTRICT

Ahmednagar. Ahmednagar. Ahm

Test Results of Ceramic Tiles (Modulus of Rupture)

Modulus of Rupture (N/sqmm)


Size/Dimension
Sr. No. Mark/Colour Average Specified
(mm) Determined
(N/sqmm) (N/sqmm)
(1) (2) (3) (4) (5) (6)

1 Vet .Tiles 605x605x10 36.30

2 Vet .Tiles 605x605x10 37.02

3 Vet .Tiles 605x605x10 39.24 37.81 35.00

4 Vet .Tiles 605x605x10 40.72

5 Vet .Tiles 605x605x10 36.80

6 Vet .Tiles 605x605x10 36.78

TESTED BY S.G. Kokate (L.A.) Assist.Reaserch 0


Officer,
CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality
Control(P.W.),
Dist.Laboratory,Ahmednagar
*
ASSISTANT RESEARCE OFFICER ASSISTANT RESEARCE OFFICER

VIGILANCE & QUALITY CONTROL VIGILANCE & QUALITY CONTROL

DISTRICT LABORATORY DISTRICT LABORATORY

Ahmednagar. Ahmednagar.
ASSISTANT RESEARCE OFFICER

VIGILANCE & QUALITY CONTROL

DISTRICT LABORATORY

Ahmednagar.
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASA-07

JOB NO. AHA / 19-20 / 34 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK C.R. To Banpimpari To Taluka Border Nimgaon Gangarda Ghumbari Belgaon
Kokangaon Ravalgaon Kumbhali Kaudhane Bitkewadi SH-55 Road MDR-100
Km 0/00 To 11/100 Tal- Karjat.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 4/4/2019
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 8987 gm (IS:383 Tab.2)

DATE OF TESTING 04/04/2019 to 05/04/2019

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 278 3.09 3.09 96.91 85-100 %
3 10 mm 7078 78.76 81.85 18.15 0-20 %
4 4.75 mm 1480 16.47 98.32 1.68 0-5 %
5 Pan 151 1.68 100.00 0
Total 8987 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING
WT. OF SAMPLE TAKEN

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 33.9 W1
2 50 mm 40 mm W2 27 W2
3 40 mm 25 mm W3 19.5 W3
4 25 mm 20 mm W4 13.5 W4
5 20 mm 16 mm W5 10.8 W5
6 16 mm 12.5 mm W6 8.55 W6
7 12.5 mm 10 mm W7 6.75 W7
8 10 mm 6.3mm W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S. G. Kokate (L.A.)


CHECKED BY Y. R. Chaudhari (R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA / 19-20 / 34 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK C.R. To Banpimpari To Taluka Border Nimgaon Gangarda Ghumbari Belgaon
Kokangaon Ravalgaon Kumbhali Kaudhane Bitkewadi SH-55 Road MDR-100
Km 0/00 To 11/100 Tal- Karjat.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 4/4/2019

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 04/04/2019 to 05/04/2019

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2178 2239
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in


3
water in gm
W3=W1-W2 1478 1539

Weight of saturated dry aggregate in


4
air in gm
W4 2251 2332

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 773 793

Weight of Oven dry aggregate in air


6
in gm
W6 2196 2278

7 Sp. Gravity W6/W5 2.84 2.87

8 Water Absorption (W4-W6)/W6 2.50% 2.37%

9 Average Sp. Gravity 2.86

10 Average Water Absorption 2.44%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA / 19-20 / 34 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK C.R. To Banpimpari To Taluka Border Nimgaon Gangarda Ghumbari
Belgaon Kokangaon Ravalgaon Kumbhali Kaudhane Bitkewadi SH-55
Road MDR-100 Km 0/00 To 11/100 Tal- Karjat.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 4/4/2019
DATE OF TESTING 04/04/2019 to 05/04/2019

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
43 44
3 Weight retained on 2.36mm IS sieve
after 15 blows in gm W3
297 299
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
12.65% 12.83%
(W2/W1)x100
6 Average Impact Value% age
12.74%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2891 2897
2 Weight of fines passing through 2.36mm
IS sieve in gm 356 356
W2
3 Weight retained on 2.36mm IS sieve in
gm 2535 2516
W3
4 Weight of sample in gm
W2+W3
2891 2872
5 Aggregate Crushing Value in % age
12.31% 12.29%
(W2/W1)x100
6 Average Crushing Value in % age
12.30%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA / 19-20 / 34 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK C.R. To Banpimpari To Taluka Border Nimgaon Gangarda Ghumbari Belgaon Kokangaon Ravalgaon Kumbhali Kaudhane Bitkewadi SH-55 Road
MDR-100 Km 0/00 To 11/100 Tal- Karjat.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 4/4/2019
DATE OF TESTING 0
TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS
% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%
20 MM 96.91 85-100%
1 20 MM METAL 10 MM 18.15 0-20%
4.75 MM 1.68 0- 5%
Pan
TEST RESULTS OF COARSE AGGREGATES
Result Obtained
Sr. No. Type of Test Result Specified for WBM Remark
20 MM METAL Trap Laterite
1 Impact Value (Not more than) 40%
2 Crushing Value (Not more than) 23% & 17 % 12% Light and Heavy traffic
3 Water Absorption (Not more than) 5%
4 Specific Gravity
5 Flakiness Index (Not more than) 15%

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S. G. Kokate (L.A.)
CHECKED BY Y. R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
100%

85-100 %

0-20 %

0-5 %
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/19-20 / 87 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK Earthwork & Blanketing To Chaurewasti To To Kokangaon Road At Mirajgaon Tal-
Karjat.
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 4/15/2019
DATE OF TESTING 15/04/2019 to 16/04/2019
WT. OF SAMPLE 11509.00 gm

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained %age Commulative %age of Specified limit


Designation in gm. Retained %age Retained passing (%age)
No.

1 80 mm 0 0.00 0.00 100.00 > 95

2 25 mm 11318 98.34 98.34 1.66 <2

3 Pan 191 1.66 100.00 0.00

Total 11509 100.00

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/19-20 / 87 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK Earthwork & Blanketing To Chaurewasti To To Kokangaon Road At Mirajgaon Tal- Karjat.

TYPE OF SAMPLE Hard Murum


DATE OF SAMPLE 4/15/2019
DATE OF TESTING 15/04/2019 to 16/04/2019
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium
other details I.S Natural Optimum
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry C.B.R. C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soaked Unsocked
(13.1) size content content

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Non Not more 80mm 100.00 > 95


-- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm 1.66 <2

TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
Remark

15

er,

y Control(P.W.),
Ahemadnagar .
Vigilance and Quality Control District Laboratory, Ahmednagar.
Test data sheet

Job No: AHA/19-20 / 669 / PW/SNR 06/08/2019


Name of Sub Dn: P.W.SubDivision Sangamner-1
Name of work: Construction Of Sabhamandap At Jorve In Grampanchayat Milkat No- 332 Tal- Sangamner
Dist- Ahmednagar.
Date of testing: 8/6/2019 to 8/7/2019
Sample No: 1

Steel test data sheet No of tests: 8

Tensile Strength of Fe 500 Bars Fe 500

S No 4 limits

ID mark NIL
Diameter in mm 12
Length in metre (L) 1.000
Mass in kg (w) 0.888
Nominal mass per metre run, kg/m 0.888

Gross cross sectional area, mm2 113.12


Original gauge length, mm (Lo) 62
Final gauge length, mm (Lu) 71

0.2 % Yield force, kN --


0.2% Proof (yield) stress, N/mm2 -- 500.00
Maximum force, kN (Fm) 62.50
Tensile strength, N/mm2 (Rm) 552.51 545.00
Percentage elongation, % 14.52 12.00
Referance: IS 1608: 2005 (test method); IS 432: 1982, IS 1786: 2008 (limits)

Coating Thickness of Steel Bars

S No 4 Remarks
1
2
3
FBEC
4 100 to 300µ

5
6
Average =
Referance: IS 13620: 1993 CL 8 (test method); CL 7 (limits)

Tested by: Kokate , LA


Checked by: Y.R. Chaudhari (R.A.) Asst Research Officer, District (VQC) Lab, Ahmednagar.
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR
8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 9/12/2019
DATE OF TESTING 12/09/2019 to 13/09/2019
WT. OF SAMPLE

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained %age Commulative %age of Specified limit


Designation in gm. Retained %age Retained passing (%age)
No.

1 80 mm > 95

2 25 mm <2

3 Pan

Total

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100
Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 9/12/2019
DATE OF TESTING 12/09/2019 to 13/09/2019
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium
other details I.S Natural Optimum
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry C.B.R. C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soaked Unsocked
(13.1) size content content

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Non Not more 80mm > 95


-- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm <2

TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
101 @ Km 1/100

Remark

15

er,

y Control(P.W.),
Ahemadnagar .
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR
8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 1/6/2022
DATE OF TESTING 06/01/2022 to 07/01/2022
WT. OF SAMPLE

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained %age Commulative %age of Specified limit


Designation in gm. Retained %age Retained passing (%age)
No.

1 80 mm > 95

2 25 mm <2

3 Pan

Total

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY Y.R. Chaudhari ( R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100
Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 1/6/2022
DATE OF TESTING 06/01/2022 to 07/01/2022
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium
other details I.S Natural Optimum
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry C.B.R. C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soaked Unsocked
(13.1) size content content

1 2 3 4 5 6 7 8 9 10 11 12 13 14
Not more 80mm -- > 95
Non
1 Hard Murum -- -- than 4% for -- -- -- -- --
Plastic
H.M. 25mm -- <2

TESTED BY S.G. Kokate (L.A.) Assist.Research Officer,


CHECKED BY Y.R. Chaudhari ( R.A.)
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahemadnagar .
101 @ Km 1/100

Remark

15

er,

Control(P.W.D),
Ahemadnagar .
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. Err:509
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur
to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-
Ahmednagar.
TYPE OF SAMPLE Gr- I Metal
DATE OF SAMPLE 1/18/2022
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 17417 gm (IS:383 Tab.2)

DATE OF TESTING 18/01/2022 To 19/01/2022

I.S.Sieve Commulative
Wt.Retained in %age Specified limit
Sr.No. Designation %age %age of passing
gm. Retained (%age)
No. Retained
1 75 mm 0 0 0 100 100%
2 63 mm 811 4.66 4.66 95.34 90 - 100 %
3 53 mm 7061 40.54 45.20 54.80 25 - 75 %
4 45 mm 8175 46.94 92.13 7.87 0 - 15 %
22.4 mm 970 5.57 97.70 2.30 0-5%
5 Pan 400 2.30 100.00
Total 17417

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING:- 18/01/2022 To 19/01/2022
WT. OF SAMPLE TAKEN:- 4601

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on IS guage size in
through IS least 200 pieces passing through guage
Sieve mm
Sieve
1 63 MM 50 MM W1 33.9 W1
2 50 MM 40 MM W2 27 W2
3 40 MM 25 MM W3 19.5 W3
4 25 MM 20 MM W4 13.5 W4
5 20 MM 16 MM W5 10.8 W5
6 16 MM 12.5 MM W6 8.55 W6
7 12.5 MM 10 MM W7 6.75 W7
8 10 MM 6.3 MM W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

:-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R.Chaudhari (R.A.)
Assist.Research Officer,

Vigilance & Quality Control(P.W.D),


Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur
to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-
Ahmednagar.
TYPE OF SAMPLE Gr- I Metal
DATE OF SAMPLE 1/6/2022

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 18/01/2022 To 19/01/2022

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate suspended in


1
water with basket in water in gm
W1 2150 2160

2 Weight of basket in water in gm W2 700 700

3 Weight of saturated aggregate in water in gm W3=W1-W2 1450 1460

Weight of saturated dry aggregate in air in


4
gm
W4 2185 2230

Weight of of water equal to the volume of


5
aggregate in gm
W5=W4-W3 735 770

6 Weight of Oven dry aggregate in air in gm W6 2130 2200

7 Sp. Gravity W6/W5 2.90 2.86

8 Water Absorption (W4-W6)/W6 2.58% 1.36%

9 Average Sp. Gravity 2.88

10 Average Water Absorption 1.97%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari (R.A.)

Assist.Research Officer,
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Gr- I Metal
DATE OF SAMPLE 1/6/2022
DATE OF TESTING 18/01/2022 To 19/01/2022

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
348 350
2 Weight of fines passing through 2.36mm IS sieve
after 15 blowsin gm W2
49 50
3 Weight retained on 2.36mm IS sieve after 15
blows in gm W3
299 300
4 Weight of sample in gm
W2+W3
348 350
5 Aggregate Impact Value % age
14.08% 14.29%
(W2/W1)x100
6 Average Impact Value% age
14.18%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2767 2770
2 Weight of fines passing through 2.36mm IS sieve
in gm 419 422
W2
3 Weight retained on 2.36mm IS sieve in gm
2348 2516
W3
4 Weight of sample in gm
W2+W3
2767 2938
5 Aggregate Crushing Value in % age
15.14% 15.23%
(W2/W1)x100
6 Average Crushing Value in % age
15.19%
REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997
Crushing Test : TP-02
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.)
Assist.Research Officer,

Vigilance & Quality Control(P.W.D),


Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100
Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Gr- I Metal
DATE OF SAMPLE 1/18/2022
DATE OF TESTING 18/01/2022 To 19/01/2022
TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS
% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified
75 mm 100 100%
63 mm 95.34 90 -100%
53 mm 54.80 25 -75 %
1 Gr- I Metal
45 mm 7.87 0 - 15%
22.4 mm 2.30 0 - 5%

Pan
TEST RESULTS OF COARSE AGGREGATES
Result Obtained
Result Specified for WBM
Sr. No. Type of Test Remark
Gr- I Metal Trap Laterite

1 Impact Value (Not more than) -- 40%

2 Crushing Value (Not more than) -- 23% & 17 % 12% Light and Heavy traffic

3 Water Absorption (Not more than) -- 5%

4 Specific Gravity --
5 Flakiness Index (Not more than) --
Note The test results are based on sample received in Laboratory
Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.D),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY AHMEDNAGAR

Job No. AHA/ 22-23 /917 / PW/ANR NO.LAB / / 2022


Office of Assistant Research Officer,
Vigilance & Quality Control ( P.W.D)
District laboratary Ahmednagar,
Dated- / / 2022
To,
Sub Divisional Engineer
P.W.Sub Division
Karjat

Subject :-Testing of Materials

Name of Work:- S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

Referance:- Your letter No Camp Dated ---

With referance to above letter, the test results for the work cited above
are enclosed herewith for your information please.

Testing charges amounting Rs. 1380 are received on online payment receipt
Transaction No 1895259981 Dated 12.09.2022 for the same Is enclosed herewith .

Assistant Research Officer,


Vigilance & Quality control(P.W.D),
District laboratory,Ahmednagar..

Copy :- M/s. Bajarangbali Construction, AP Therwadi, Tal- Karjat, Dist-A.Nagar


VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY AHMEDNAGAR
Checklist for acceptance of sample.
1) Name and address of organization Sub Divisional Engineer P.W.Sub Division Karjat
2) Name of agency M/s. Bajarangbali Construction, AP Therwadi, Tal- Karjat, Dist-A.Nagar

3) Details of samples.
i)Name of work S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat
Dist-Ahmednagar.
ii)Material/Location.
iii)Quantity
4) Date of receipt of sample. 9/15/2022
5) Whether samples are accompained with letter Yes
if yes,then give letter No. and date Camp Dated --
if no, samples are not accepted
6) Details of tests to be conducted and testing charges
D.S.R. Item
Sr. No. Materialas Name of tests No. of tests Rate Amount
No.

Concrete Cube wa,sp.Comp.


1 19 2 690 1380
( M.10 ) Strength.Efflo.

7) Whether samples are marked with lables Y/N Yes Total 1380
by the organisation
if no samples are not accepted
8) Whether the quantity of samples are Y/N Yes
adequate for testing
9) Whether testing facility is available in the lab Y/N Yes
10) Whether serviceble and calibrated equipment Y/N Yes
are available
11) Whether trained person available for testing. Y/N Yes
11) Customer requirement if any, Y/N
13) Details of receipt of testing charges Transaction No 1895259981
Date 12.09.2022
Rs. 1380
Recived by Approved by

R.A
Assistant Research officer
District Laboratory Ahemadnagar.

14) If approved give job no. AHA/ 22-23 /917 / PW/ANR


VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Works Division , Ahmednagar
NAME OF SUB DIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km
1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/15/2022 Date of Testing :-17/09/2022 to 17/09/2022
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A.1 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 320 14.22

PCC Solid
2 A.2 M-10 5/23/2022 9/17/2022 117 149X148X150 22052 320 14.51 14.47 13.50
Returns

3 A.3 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 330 14.67

4 B.1 M-10 5/23/2022 9/17/2022 117 149X148X150 22052 330 14.97

PCC Solid
5 B.2 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 330 14.67 14.62 13.50
Returns

6 B.3 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 320 14.22

Reference I.S. 516-1999 CL.5.5. Assist.Research Officer,


TESTED BY P.R.Darade, Sect.Engr
CHECKED BY A.R.Anand (ARO) Vigilance & Quality Control(P.W.D),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Works Division , Ahmednagar
NAME OF SUB DIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 9/15/2022 Date of Testing :-17/09/2022 to 17/09/2022
Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A.1 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 320 14.22

PCC Solid
2 A.2 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 320 14.51 14.47 13.50
Returns

3 A.3 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 330 14.67

4 B.1 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 330 14.97

PCC Solid
5 B.2 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 330 14.67 14.62 13.50
Returns

6 B.3 M-10 5/23/2022 9/17/2022 117 150x150x150 22500 320 14.22

Reference I.S. 516-1999 CL.5.5. Assist.Research Officer,


TESTED BY P.R.Darade, Sect.Engr
CHECKED BY A.R.Anand (ARO) Vigilance & Quality Control(P.W.D),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASA-07

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE 20 mm Metal For Concrete


DATE OF SAMPLE 6/17/2021
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 9127 gm (IS:383 Tab.2)

DATE OF TESTING 17/06/2021 TO 18/06/2021

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 308 3.37 3.37 96.63 85-100 %
3 10 mm 7081 77.58 80.95 19.05 0-20 %
4 4.75 mm 1450 15.89 96.84 3.16 0-5 %
5 Pan 288 3.16 100.00 0
Total 9127 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING 17/06/2021 TO 18/06/2021
WT. OF SAMPLE TAKEN 5180 gm

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 0 33.9 W1 0
2 50 mm 40 mm W2 0 27 W2 0
3 40 mm 25 mm W3 0 19.5 W3 0
4 25 mm 20 mm W4 199 13.5 W4 59
5 20 mm 16 mm W5 1299 10.8 W5 228
6 16 mm 12.5 mm W6 1352 8.55 W6 138
7 12.5 mm 10 mm W7 1398 6.75 W7 198
8 10 mm 6.3mm W8 932 4.89 W8 99
TOTAL W 5180 W* 722
FLAKINESS INDEX (W*/W)X100 = 722 / 5180 13.94%

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari ( R.A.)

Assist.Research Officer,
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE 20 mm Metal For Concrete


DATE OF SAMPLE 6/17/2021

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 17/06/2021 TO 18/06/2021

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2203 2216
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in water


3
in gm
W3=W1-W2 1503 1516

Weight of saturated dry aggregate in


4
air in gm
W4 2290 2301

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 787 785

Weight of Oven dry aggregate in air in


6
gm
W6 2260 2270

7 Sp. Gravity W6/W5 2.87 2.89

8 Water Absorption (W4-W6)/W6 1.33% 1.37%

9 Average Sp. Gravity 2.88

10 Average Water Absorption 1.35%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari ( R.A.)

Assist.Research Officer,
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat
Dist-Ahmednagar.
TYPE OF SAMPLE 20 mm Metal For Concrete
DATE OF SAMPLE 6/17/2021
DATE OF TESTING 17/06/2021 TO 18/06/2021

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
48 49
3 Weight retained on 2.36mm IS sieve after
15 blows in gm W3
292 294
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
14.12% 14.29%
(W2/W1)x100
6 Average Impact Value% age
14.20%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2766 2770
2 Weight of fines passing through 2.36mm
IS sieve in gm 420 421
W2
3 Weight retained on 2.36mm IS sieve in
gm 2346 2516
W3
4 Weight of sample in gm
W2+W3
2766 2937
5 Aggregate Crushing Value in % age
15.18% 15.20%
(W2/W1)x100
6 Average Crushing Value in % age
15.19%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari ( R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE;-
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-
Ahmednagar.
TYPE OF SAMPLE 20 mm Metal For Concrete
DATE OF SAMPLE 6/17/2021
DATE OF TESTING 17/06/2021 TO 18/06/2021

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%

20 MM 96.63 85-100%

1 20 mm Metal For Concrete 10 MM 19.05 0-20%

4.75 MM 3.16 0- 5%

Pan 0

TEST RESULTS OF COARSE AGGREGATES

Result Obtained
Sr. No. Type of Test Result Specified for WBM Remark
20 mm Metal For Concrete Trap Laterite

1 Flakiness Index (Not more than) 13.94% 15%

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari ( R.A.) Vigilance & Quality Control(P.W.D),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASA-07

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/16/2019
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 8888 gm (IS:383 Tab.2)

DATE OF TESTING 16/09/2019 to 17/09/2019

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 248 2.79 2.79 97.21 85-100 %
3 10 mm 7058 79.41 82.20 17.80 0-20 %
4 4.75 mm 1451 16.33 98.53 1.47 0-5 %
5 Pan 131 1.47 100.00 0
Total 8888 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING
WT. OF SAMPLE TAKEN

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 33.9 W1
2 50 mm 40 mm W2 27 W2
3 40 mm 25 mm W3 19.5 W3
4 25 mm 20 mm W4 13.5 W4
5 20 mm 16 mm W5 10.8 W5
6 16 mm 12.5 mm W6 8.55 W6
7 12.5 mm 10 mm W7 6.75 W7
8 10 mm 6.3mm W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S. G. Kokate (L.A.)


CHECKED BY Y. R. Chaudhari (R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/16/2019

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 16/09/2019 to 17/09/2019

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2178 2239
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in


3
water in gm
W3=W1-W2 1478 1539

Weight of saturated dry aggregate in


4
air in gm
W4 2251 2332

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 773 793

Weight of Oven dry aggregate in air


6
in gm
W6 2196 2278

7 Sp. Gravity W6/W5 2.84 2.87

8 Water Absorption (W4-W6)/W6 2.50% 2.37%

9 Average Sp. Gravity 2.86

10 Average Water Absorption 2.44%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/16/2019
DATE OF TESTING 16/09/2019 to 17/09/2019

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
43 44
3 Weight retained on 2.36mm IS sieve
after 15 blows in gm W3
297 299
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
12.65% 12.83%
(W2/W1)x100
6 Average Impact Value% age
12.74%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2891 2897
2 Weight of fines passing through 2.36mm
IS sieve in gm 356 356
W2
3 Weight retained on 2.36mm IS sieve in
gm 2535 2516
W3
4 Weight of sample in gm
W2+W3
2891 2872
5 Aggregate Crushing Value in % age
12.31% 12.29%
(W2/W1)x100
6 Average Crushing Value in % age
12.30%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-
Ahmednagar.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/16/2019
DATE OF TESTING 16/09/2019 to 17/09/2019
TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS
% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%
20 MM 97.21 85-100%
1 20 MM METAL 10 MM 17.80 0-20%
4.75 MM 1.47 0- 5%
Pan
TEST RESULTS OF COARSE AGGREGATES
Note The test results are based on sample received in Laboratory
Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S. G. Kokate (L.A.)
CHECKED BY Y. R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
100%

85-100 %

0-20 %

0-5 %
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA / 19-20 / 34 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK C.R. To Banpimpari To Taluka Border Nimgaon Gangarda Ghumbari Belgaon
Kokangaon Ravalgaon Kumbhali Kaudhane Bitkewadi SH-55 Road MDR-100 Km
0/00 To 11/100 Tal- Karjat.

TYPE OF SAMPLE Hard Murum


DATE OF SAMPLE 4/4/2019
DATE OF TESTING 04/04/2019 TO 05/04/2019
WT. OF SAMPLE 11761.00 gm

SIEVE ANALYSIS FOR HARD MURUM

I.S.Sieve
Wt.Retained %age Commulative %age of Specified limit
Sr.No. Designation
in gm. Retained %age Retained passing (%age)
No.

1 80 mm 0 0.00 0.00 100.00 > 95

2 25 mm 11599 98.62 98.62 1.38 <2

3 Pan 162 1.38 100.00 0.00

Total 11761 100.00

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT


Hence material is Non Plastic
Reference :- IS 2720 (PART V) 1985

TESTED BY S. G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y. R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA / 19-20 / 34 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK C.R. To Banpimpari To Taluka Border Nimgaon Gangarda Ghumbari Belgaon Kokangaon Ravalgaon Kumbhali Kaudhane
Bitkewadi SH-55 Road MDR-100 Km 0/00 To 11/100 Tal- Karjat.

TYPE OF SAMPLE Hard Murum


DATE OF SAMPLE 4/4/2019
DATE OF TESTING 04/04/2019 TO 05/04/2019
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium
other details I.S Natural Optimum Remark
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry C.B.R. C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soaked Unsocked
(13.1) size content content

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Non Not more 80mm 100.00 > 95


-- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm 1.38 <2

TESTED BY S. G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y. R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR
8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE Hard Murum


DATE OF SAMPLE 8/14/2019
DATE OF TESTING 14/08/2019 to 16/08/2019
WT. OF SAMPLE

SIEVE ANALYSIS FOR HARD MURUM

I.S.Sieve
Wt.Retained %age Commulative %age of Specified limit
Sr.No. Designation
in gm. Retained %age Retained passing (%age)
No.

1 80 mm > 95

2 25 mm <2

3 Pan

Total

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT


Hence material is Non Plastic
Reference :- IS 2720 (PART V) 1985

TESTED BY S. G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y. R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100
Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE Hard Murum


DATE OF SAMPLE 8/14/2019
DATE OF TESTING 14/08/2019 to 16/08/2019
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium
other details I.S Natural Optimum Remark
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry C.B.R. C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soaked Unsocked
(13.1) size content content

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Non Not more 80mm > 95


-- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm <2

TESTED BY S. G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y. R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY, AHMEDNAGAR

CEMNT TEST
Job No. AHA/ 22-23 /917 / PW/ANR
Name of Division 0 Ahmednagar
Name of Sub-Division P.W.SubDivision Karjat
Name of Work S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon
road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
Date of Testing 18/01/2022 To 28/01/2022
Details of Sample Birla A-1- 53 - Grade
TEST DATA SHEET : DCCT-01
Consistency
Wt. of cement Vol. of water Percentage of
Trial Reading on Vicat app. In
taken for test in added to dry water added Consistancy Remark
No. (mm)
gm cement in cc in dry cement
2 400 118 29.5 8 Hence Consistancy is
3 400 122 30.5 5
30.25
4 400 121 30.3 6

TEST DATA SHEET : DCCT-02


Setting Time
Requirement of Actual water A B C Limits as per IS Ref.
water Requirement
Final Initial Final Initial
0.85 ×P=V Time for
Sr. Wt. of cement in Initial Setting Setting Setting Setting Setting
P=Std. V×400 adding water
No. gms 100 Time Hr. Time Time Time Time
Consistency in cement Hr.
Min. (B-A) Hr. Min (Min) (Min.) (Min)
Min.
(C-A)
1 2 3 4 5 6 7 8

× 400/
0.85× 30.3 25.71 1:10 7:40 30
100
1 400 gms 10:10 11:20 17:50
=
25.71 = 102.85 70 min 460 Minimum

TEST DATA SHEET : DCCT-03


Fineness by Sieving

Wt. of cement on 90
Wt. of cement Residue in
Sr. Time of Sieving mic. Sieve retained
Trial No. before sieving % observed Average % Residue Specified
No. in Min. after sieving in gm.
in gm(W1) = 5/3×100
(W2)

1 2 3 4 5 6 7 8
1 1 100 gms 15 minutes 5.00 5.00
5% Max for PPC
2 2 100 gms 15 minutes 6.00 6.00 5.67
10% Max for OPC
3 3 100 gms 15 minutes 6.00 6.00

Reference : Consistency- Methods of Physical tests for hydraulic cement.As per I.S 4031-1997 CL.6
Setting Time- As per I.S 4031-1998 CL.7
Fineness-As per I.S 4031-1996 CL.8

Tested by : S.G. Kokate (L.A.) Assist.Research Officer,


Checked by : Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.D),
Equipment used :Vicat apparatus and Vicat mould,I.S sieve. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
Cement Tests
Job No. AHA/ 22-23 /917 / PW/ANR
Name of Division 0 Ahmednagar
Name of Sub-Division P.W.SubDivision Karjat
Name of Work S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road
MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
Date of Testing 18/01/2022 To 28/01/2022
Details of Sample Birla A-1- 53 - Grade

TEST DATA SHEET : DCCT-04


Specific gravity
Sr.No. Description Flask 1 flask 2 Dummy Flask Limit
1 Wt. of cement taken for test in gm 64.00 64.00 -
Initial Level of liquid (Kerosene) in flask in ml
2 0.00 0.00 0
Final Level of liquid (Kerosene) in flask in ml
3 20.50 20.40 0
Increase in level of Dummy Flask due to temp
4 0.00 0.00 0 3.10 to 3.15

Correct volume of liquid after appling temp.


5 correction 20.50 20.40 -

6 Specific Gravity 3.12 3.14 -


7 Av.Specific Gravity 3.13 -

TEST DATA SHEET : DCCT-05


Soundness of cement
Sr. Wt. of cement Requirement of water Actual water requirement in CC Distance separating the
No. taken for test in V =0.78 x P = (V X 200) indicater point in mm Limits as per IS Ref.
gm
P=Std. consistancy 100 Initial Final Diff.
12 14 2
0.78× 30.25 23.60 × 200 16 19 3 Expansion Not More
1 200 gms
= 23.60 = 47.19 17 20 3 Than 10 mm

Say 47 CC Average 2.666667

TEST DATA SHEET : DCCT-06


Compressive Strength Test
Wt. of water Curing Comp
Wt. of Wt. of Comp Av.Comp
Sr. Normal to be added in Date of Date Of period of Strength
Consiste Cement Standard sand Strength Strength In
No ncy (P)% CC = casting testing Mortor load In
in gms in gms In N/mm² N/mm²
(P/4+3)8 cubes kN
1 2 3 4 5 6 7 8 9 10 11
1 30.25 200 gms 600 gms 84.5 1/21/2022 1/24/2022 3 138 27.60
2 30.25 200 gms 600 gms 84.5 1/21/2022 1/24/2022 3 142 28.40 28.00
3 30.25 200 gms 600 gms 84.5 1/21/2022 1/24/2022 3 140 28.00
4 30.25 200 gms 600 gms 84.5 1/21/2022 1/28/2022 7 188 37.60
5 30.25 200 gms 600 gms 84.5 1/21/2022 1/28/2022 7 190 38.00 38.00
6 30.25 200 gms 600 gms 84.5 1/21/2022 1/28/2022 7 192 38.40

Reference : Specific Gravity-As per I.S 4031-1992 CL.13


Soundness-As per I.S 4031-1996 CL.5
Comp. strength-As per I.S 4031-2000 CL.8
Tested by : S.G. Kokate (L.A.) Assist.Research Officer,
Checked by : Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.D),
Equipment used :Std. Lechatelier flasks,Chatelier Test apparatus and CTM Dist.Laboratory,Ahmednagar
Machine.
K

adpur to MDR 8 Chapadgaon

Remark

Limits as per IS Ref.


Final
Setting
Time
(Min.)

600

Maximum

Remarks

search Officer,
ality Control(P.W.D),
tory,Ahmednagar
K

ur to MDR 8 Chapadgaon road

Limit

3.10 to 3.15

Limits as per IS Ref.

Expansion Not More


Than 10 mm

Requireme
nt as per
IS in
N/mm²
12

27

37

search Officer,
ality Control(P.W.D),
tory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE;-
NAME OF DIVISION 0 Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8
Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Birla A-1- 53 - Grade
DATE OF RECEIPT OF SAMPLE 1/18/2022 DATE OF TESTING;- 18/01/2022 To 28/01/2022
TEST RESULT OF CEMENT
Results obtained
Sr. No. Type of test Specified Limits
Sample-1
1 Fineness (%) 5.67 10% for OPC 5% for PPC
2 Setting Time(Min)
Initial 70 min Not less than 30 minutes.
Final 460.00 Not More than 600 minutes.
3 Compresive Strength in N/sqmm Curing Period 33 Grade 43 Grade 53Grade
For 3Days 28.00 For 3 Days 16 N/mm² 23 N/mm² 27 N/mm²
For 7Days 38.00 For 7 Days 22 N/mm² 33 N/mm² 37 N/mm²
For 28Days ……… For 28 Days 33 N/mm² 43 N/mm² 53 N/mm²
Soundness by Le-Chateliar Apparatus
4 3 Expansion not more than 10 mm
mm
5 Specific Gravity 3.13 3.10 to 3.15
6 Std. Consistancy 30.3 Not Specified

Note : The test results are based on smaples received in Laboratory.

Reference : IS 4031 Part (I)1996 , IS 4031 Part (V)1998, IS 4031(VI)1992.


Tested by : S.G. Kokate (L.A.)
Checked by: Y.R.Chaudhari (R.A.) Assist.Research Officer,

Equipment used : Vicat Apparatus, Lechatelier Apparatus, CTM Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

BRICKS TEST
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION 0 Sangamner
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8
Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :-Bricks
DATE OF RECPT. OF SAMPLE 8/24/2021
DATE OF TESTING 24/08/2021 To 29/08/2021

WATER ABSORPTION TEST


% of water
Sr. S.S.D. Wt. of Brick W1 Oven Dried Wt. of Brick
Wt. of water (W1-W2) absorption=(W1- Limits
No. in gm W2 gm
W2)/W2 X 100
1 2625 2168 457 21.08%
For Ist Class 20 %
2 2618 2157 461 21.37%
Max.
3 2626 2164 462 21.35%
4 2631 2171 460 21.19%
For IInd Class 22 %
5 2635 2177 458 21.04%
Max.
Average 21.21%

CRUSHING STRENGTH TEST


Compressive Load in Compressive Strength in
Sr. Identification kN N/sqmm
Size of Brick Area of Brick Limits
No. Mark
Dry Wet Dry Wet
1 225x98x74 22050 72 3.27
For Ist Class Not Less
2 ……do…… 228x97x75 22116 68 3.07
Than 3.28 N/mm²
3 ……do…… 228x98x74 22344 66 2.95

4 ……do…… 229x97x75 22213 68 3.06


For IInd Class Not
5 ……do…… 227x98x75 22246 70 3.15 Less Than 2.95
N/mm²
Av. 3.10

Efflorescence

As there is 10 % perciptable residue or deposit on surface of brick after keeping both the ends of brick in water for 24 hours .
Hence effloerance is Slight

Reference : I.S.3495 1992,Part-I,II,& as per TP-04.

Tested by S.G. Kokate (L.A.)


Checked by Y.R.Chaudhari (R.A.)
Equipment used ;- C.T.M.Machine, Oven.
Assist.Research Officer,
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR

JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:- DATE;-


NAME OF DIVISION 0 Sangamner
NAME OF SUBDIVISION Public Work Sub. Division Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road
MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :-Bricks
DATE OF RECEIPT OF SAMPLE 8/24/2021 DATE OF TESTING;- 24/08/2021 To 29/08/2021

TEST RESULT OF BRICKS


Water Absorption Crushing strength
Identification
Sr. No. Size of Bricks in cm. Specified Determined Specified Limit
Mark Determined
Limit Dry Wet Dry Wet
1 225x98x74 21.08% 3.27 For Ist Class For Ist Class
For Ist Class
Not Less Not Less
2 ……do…… 228x97x75 21.37% Not More 3.07 Than 4.37 Than 3.28
Than 20 %
3 ……do…… 228x98x74 21.35% 2.95 N/mm² N/mm²

4 ……do…… 229x97x75 21.19% 3.06 For IInd Class For Iind Class
For IInd Class
5 ……do…… 227x98x75 21.04% 3.15 Not Less Not Less
Not More
Than 3.93 Than 2.95
Than 22 %
Average 21.21% Average 3.10 N/mm² N/mm²

THE TEST RESULT OF BRICK EFFLORESCENCE

As there is 10 % perciptable residue or deposit on surface of brick after keeping both the ends of brick in water for 24 hours . Hence effloerance is Slight
Note :-The test result based on samples received in the Laboratory
Reference : :- I.S.3495 ( Part (I), (II) 1992

Tested by : S.G. Kokate (L.A.)


Checked by: Y.R.Chaudhari (R.A.) Assist.Research Officer,
Equipment used :- CTM Machine , Oven. Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASA-07

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/6/2018
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 8983 gm (IS:383 Tab.2)

DATE OF TESTING 9/6/2018

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 263 2.93 2.93 97.07 85-100 %
3 10 mm 7081 78.83 81.75 18.25 0-20 %
4 4.75 mm 1458 16.23 97.99 2.01 0-5 %
5 Pan 181 2.01 100.00 0
Total 8983 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING
WT. OF SAMPLE TAKEN gm

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 33.9 W1
2 50 mm 40 mm W2 27 W2
3 40 mm 25 mm W3 19.5 W3
4 25 mm 20 mm W4 13.5 W4
5 20 mm 16 mm W5 10.8 W5
6 16 mm 12.5 mm W6 8.55 W6
7 12.5 mm 10 mm W7 6.75 W7
8 10 mm 6.3mm W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R.Chaudhari (R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to
MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/6/2018

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 43349

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2178 2239
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in water


3
in gm
W3=W1-W2 1478 1539

Weight of saturated dry aggregate in


4
air in gm
W4 2251 2332

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 773 793

Weight of Oven dry aggregate in air in


6
gm
W6 2196 2278

7 Sp. Gravity W6/W5 2.84 2.87

8 Water Absorption (W4-W6)/W6 2.50% 2.37%

9 Average Sp. Gravity 2.86

10 Average Water Absorption 2.44%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat
Dist-Ahmednagar.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/6/2018
DATE OF TESTING 43349

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
43 44
3 Weight retained on 2.36mm IS sieve after
15 blows in gm W3
297 299
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
12.65% 12.83%
(W2/W1)x100
6 Average Impact Value% age
12.74%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2891 2897
2 Weight of fines passing through 2.36mm
IS sieve in gm 356 356
W2
3 Weight retained on 2.36mm IS sieve in
gm 2535 2516
W3
4 Weight of sample in gm
W2+W3
2891 2872
5 Aggregate Crushing Value in % age
12.31% 12.29%
(W2/W1)x100
6 Average Crushing Value in % age
12.30%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION P.W.Sub Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-
Ahmednagar.
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/6/2018
DATE OF TESTING 9/6/2018

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%

20 MM 97.07 85-100%

1 20 MM METAL 10 MM 18.25 0-20%

4.75 MM 2.01 0- 5%

Pan 0.00 0

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY, AHMEDNAGAR

TEST DATA SHEET : DCE -03 REVISION'O' PAGE 1 OF 1


CEMNT TEST
Job No. AHA/ 22-23 /917 / PW/ANR
Name of Division Public Work Divi. Ahmednagar
Name of Sub-Division P.W.SubDivision Parner
Name of Work S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon
road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
Date of Testing 06/09/2018 TO 15/09/2018
Details of Sample Ultratech 53- Grade
TEST DATA SHEET : DCCT-01
Consistency
Wt. of cement Vol. of water Percentage of
Trial Reading on Vicat app. In
taken for test in added to dry water added Consistancy Remark
No. (mm)
gm cement in cc in dry cement
2 400 120 30.0 9 Hence Consistancy is
3 400 125 31.3 5
30.75
4 400 123 30.8 6

TEST DATA SHEET : DCCT-02


Setting Time
Requirement of Actual water A B C Limits as per IS Ref.
water Requirement
Final Initial Final Initial
0.85 ×P=V Time for
Sr. Wt. of cement in Initial Setting Setting Setting Setting Setting
P=Std. V×400 adding water
No. gms 100 Time Hr. Time Time Time Time
Consistency in cement Hr.
Min. (B-A) Hr. Min (Min) (Min.) (Min)
Min.
(C-A)
1 2 3 4 5 6 7 8

× 400/
0.85× 30.8 26.14 1:10 7:00 30
100
1 400 gms 10:30 11:40 17:30
=
26.14 = 104.55 70 min 400 min Minimum

TEST DATA SHEET : DCCT-03


Fineness by Sieving

Wt. of cement on 90
Wt. of cement Residue in
Sr. Time of Sieving mic. Sieve retained
Trial No. before sieving % observed Average % Residue Specified
No. in Min. after sieving in gm.
in gm(W1) = 5/3×100
(W2)

1 2 3 4 5 6 7 8
1 1 100 gms 15 minutes 5.00 5.00
5% Max for PPC
2 2 100 gms 15 minutes 4.00 4.00 4.67
10% Max for OPC
3 3 100 gms 15 minutes 5.00 5.00

Reference : Consistency- Methods of Physical tests for hydraulic cement.As per I.S 4031-1997 CL.6
Setting Time- As per I.S 4031-1998 CL.7
Fineness-As per I.S 4031-1996 CL.8

Tested by : S.G. Kokate (L.A.) Assist.Reaserch Officer,


Checked by : Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Equipment used :Vicat apparatus and Vicat mould,I.S sieve. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
Cement Tests
Job No. AHA/ 22-23 /917 / PW/ANR
Name of Division Public Work Divi. Ahmednagar
Name of Sub-Division P.W.SubDivision Parner
Name of Work S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road
MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
Date of Testing 06/09/2018 TO 15/09/2018
Details of Sample Ultratech 53- Grade

TEST DATA SHEET : DCCT-04


Specific gravity
Sr.No. Description Flask 1 flask 2 Dummy Flask Limit
1 Wt. of cement taken for test in gm 64.00 64.00 -
Initial Level of liquid (Kerosene) in flask in ml
2 0.00 0.00 0
Final Level of liquid (Kerosene) in flask in ml
3 20.50 20.50 0
Increase in level of Dummy Flask due to temp
4 0.00 0.00 0 3.10 to 3.15

Correct volume of liquid after appling temp.


5 correction 20.50 20.50 -

6 Specific Gravity 3.12 3.12 -


7 Av.Specific Gravity 3.12 -

TEST DATA SHEET : DCCT-05


Soundness of cement
Sr. Wt. of cement Requirement of water Actual water requirement in CC Distance separating the
No. taken for test in V =0.78 x P = (V X 200) indicater point in mm Limits as per IS Ref.
gm
P=Std. consistancy 100 Initial Final Diff.
12 14 2
0.78× 30.75 23.99 × 200 16 19 3 Expansion Not More
1 200 gms
= 23.99 = 47.97 17 20 3 Than 10 mm

Say 48 CC Average 2.666667

TEST DATA SHEET : DCCT-06


Compressive Strength Test
Wt. of water Curing Comp
Wt. of Wt. of Comp Av.Comp
Sr. Normal to be added in Date of Date Of period of Strength
Consiste Cement Standard sand Strength Strength In
No ncy (P)% CC = casting testing Mortor load In
in gms in gms In N/mm² N/mm²
(P/4+3)8 cubes kN
1 2 3 4 5 6 7 8 9 10 11
1 30.75 200 gms 600 gms 85.5 9/8/2018 9/11/2018 3 138 27.60
2 30.75 200 gms 600 gms 85.5 9/8/2018 9/11/2018 3 136 27.20 27.47
3 30.75 200 gms 600 gms 85.5 9/8/2018 9/11/2018 3 138 27.60
4 30.75 200 gms 600 gms 85.5 9/8/2018 9/15/2018 7 188 37.60
5 30.75 200 gms 600 gms 85.5 9/8/2018 9/15/2018 7 188 37.60 37.73
6 30.75 200 gms 600 gms 85.5 9/8/2018 9/15/2018 7 190 38.00

Reference : Specific Gravity-As per I.S 4031-1992 CL.13


Soundness-As per I.S 4031-1996 CL.5
Comp. strength-As per I.S 4031-2000 CL.8
Tested by : S.G. Kokate (L.A.) Assist.Reaserch Officer,
Checked by : Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Equipment used :Std. Lechatelier flasks,Chatelier Test apparatus and CTM Dist.Laboratory,Ahmednagar
Machine.
K

PAGE 1 OF 1

adpur to MDR 8 Chapadgaon

Remark

Limits as per IS Ref.


Final
Setting
Time
(Min.)

600

Maximum

Remarks

aserch Officer,
uality Control(P.W.),
tory,Ahmednagar
K

ur to MDR 8 Chapadgaon road

Limit

3.10 to 3.15

Limits as per IS Ref.

Expansion Not More


Than 10 mm

Requireme
nt as per
IS in
N/mm²
12

27

37

aserch Officer,
uality Control(P.W.),
tory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR.;- DATE;-
NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Parner
NAME OF WORK Construction Of Social Community Hall @ Grampanchyat Milkat 293 Akklwadi Tal- Parner.

TYPE OF SAMPLE Ultratech 53- Grade


DATE OF RECEIPT OF SAMPLE 9/16/2019 DATE OF TESTING;- 06/09/2018 TO 15/09/2018
TEST RESULT OF CEMENT
Results obtained
Sr. No. Type of test Specified Limits
Sample-1
1 Fineness (%) 4.67 10% for OPC 5% for PPC
2 Setting Time(Min)
Initial 70 min Not less than 30 minutes.
Final 400 min Not More than 600 minutes.
3 Compresive Strength in N/sqmm Curing Period 33 Grade 43 Grade 53Grade
For 3Days 27.47 For 3 Days 16 N/mm² 23 N/mm² 27 N/mm²
For 7Days 37.73 For 7 Days 22 N/mm² 33 N/mm² 37 N/mm²
For 28Days ……… For 28 Days 33 N/mm² 43 N/mm² 53 N/mm²
Soundness by Le-Chateliar Apparatus
4 3 Expansion not more than 10 mm
mm
5 Specific Gravity 3.12 3.10 to 3.15
6 Std. Consistancy 30.8 Not Specified

Note : The test results are based on smaples received in Laboratory.

Reference : IS 4031 Part (I)1996 , IS 4031 Part (V)1998, IS 4031(VI)1992.


Tested by : S.G. Kokate (L.A.)
Checked by: Y.R.Chaudhari (R.A.) Assist.Reaserch Officer,

Equipment used : Vicat Apparatus, Lechatelier Apparatus, CTM Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 8.435 190 8.44

2 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 8.442 210 9.33 8.89 8.02

3 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 8.441 200 8.89

4 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 8.453 260 11.56

5 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 8.458 250 11.11 11.11 10.65

6 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 8.448 240 10.67

Reference I.S. 516-1999 CL.5.5. D.J.Officer,


Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes


Above 700
Cross Average Reqd.
Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 8.462 250 11.11

2 A-2 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 8.459 240 10.67 10.81 10.01

3 A-3 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 8.457 240 10.67

Reference I.S. 516-1999 CL.5.5.


D.J. Shewale
Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.441 260 11.56

2 D-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.452 530 23.56 19.85 23.10

3 D-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.458 550 24.44

4 E-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.462 550 24.44

5 E-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.454 540 24.00 24.30 23.10

6 E-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.459 550 24.44

Reference I.S. 516-1999 CL.5.5. D.J. Shewale


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 F-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.447 540 24.00

2 F-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.457 530 23.56 24.00 23.15

3 F-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.442 550 24.44

4 G-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.462 550 24.44

5 G-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.459 540 24.00 24.30 23.15

6 G-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.459 550 24.44

Reference I.S. 516-1999 CL.5.5.


D.J. Shewale
S.G. Kokate( L.A) Assist.Reaserch Officer,
TESTED BY
Vigilance & Quality
CHECKED BY S.V. Potdar (Sect.Engr.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 H-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 660 29.33

2 H-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 790 35.11 32.15 30.00 i

3 H-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 720 32.00

4 I-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 690 30.67

5 I-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 750 33.33 31.85 30.00 j

6 I-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 710 31.56

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 710 31.56

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 690 30.67 32.59 30.00 k

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 800 35.56

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 680 30.22

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 710 31.56 32.30 30.00 l

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 790 35.11

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 225 10.00

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 225 10.00 10.00 10.00 m

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 225 10.00

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 225 10.00

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 225 10.00 10.00 20.00 n

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 225 10.00

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 15.00 o

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 16.00 p

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 17.00 q

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 18.00 r

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahm

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.10

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 23.10

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.

S.G. Kokate( L.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY S.V. Potdar (Sect.Engr.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
Karjat Dist-Ahmednagar.
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 190 8.44

2 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 210 9.33 8.89 8.02

3 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 200 8.89

4 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 260 11.56

5 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 250 11.11 11.11 10.65

6 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 240 10.67

Reference I.S. 516-1999 CL.5.5. D.J. Officer,


Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 250 11.11

2 A-2 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 240 10.67 10.81 10.01

3 A-3 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 240 10.67

Reference I.S. 516-1999 CL.5.5.


D.J. Officer,
Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

DIST. LABORATORY, AHMEDNAGAR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 D-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 260 11.56

2 D-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 530 23.56 19.85 23.10

3 D-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 550 24.44

4 E-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 550 24.44

5 E-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 540 24.00 24.30 23.10

6 E-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 550 24.44

Reference I.S. 516-1999 CL.5.5.


D.J. Officer,
Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

DIST. LABORATORY, AHMEDNAGAR


JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 F-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 540 24.00

2 F-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 530 23.56 24.00 23.15

3 F-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 550 24.44

4 G-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 550 24.44

5 G-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 540 24.00 24.30 23.15

6 G-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 550 24.44

Reference I.S. 516-1999 CL.5.5.


D.J. Officer,
Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 H-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 660 29.33

2 H-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 790 35.11 32.15 30.00 i

3 H-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 720 32.00

4 I-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 690 30.67

5 I-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 750 33.33 31.85 30.00 j

6 I-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 710 31.56

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 710 31.56

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 690 30.67 32.59 30.00 k

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 800 35.56

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 680 30.22

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 710 31.56 32.30 30.00 l

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 790 35.11

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00 10.00 10.00 m

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00 10.00 20.00 n

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 15.00 o

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 16.00 p

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 17.00 q

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 18.00 r

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 22.00 v
22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 24.00 x
24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-Ahmednagar.
Cubes

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09


4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-A

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.10 0

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09


4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 23.10 0

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR LAB./NO./SNR:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon
road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Rubble
DATE OF REC. OF SAMPLE 9/16/2019
DATE OF TESTING 16/09/2019 to 19/09/2019

TEST RESULTS OF BUILDING STONE/RUBBLE

D
Impact
% Water Absorption Apparent Compressive Strength (N/sqmm) eCrushing Value(%)
Sourse & Value(%)
Sr.No. Specific t Remarks
Other Details e
Gravity
r Determine
Specified Determined Specified Determined Specified Specified
m d
Vide Std.
i
Specification n
Gray Blakish
1
Rubble.
Clause A 4.17 2.88 Vide IS 1597 Part-1 1967 40.00N/mm2 41.00 Max.30% eMax.30%
--------
8.1Not more
than 5%
d

Note :-The test result based on samples received in the Laboratory


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R.Chaudhari (R.A.) Assist.Reaserch Officer,
Vigilance & Quality
Equipment used :- CTM Machine. Dist.Laboratory,Ahmednag
Control(P.W.),
ar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Ahmednagar
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat
Dist-Ahmednagar.
TYPE OF SAMPLE :-Rubble
DATE OF SAMPLE 9/16/2019
DATE OF TESTING 16/09/2019 to 19/09/2019

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

Sr.No. Particular Trial-1 Trial-2


Weight of saturated dry aggregate in air
1 in gm(Passing through 20mm sieve & B 1184 1164
retained on 10mm sieve )
Quantity of water added in 1000ml jar
2 containing the test pieces C 609 609
Weight of Oven dry aggregate in gm
3 A 1135 1119

4 Apperant Sp. Gravity A/(1000-C) 2.90 2.86


5 Water Absorption (B-A)/A x 100 4.317 4.021
6 Average Sp. Gravity 2.88
7 Average Water Absorption 4.17

CRUSHING STRENGTH OF BUILDING STONE

Sr .No. Particular Trial-1 Trial-2

1 Identificaton Mark ………… …………

2 Size of specimen 100x100x100 100x100x100

3 C/S Area perpendicular to load sqmm 10000.00 10000.00

4 Crushing Load in (kN) 400.00 420.00

5 Crushing Strength (N/sqmm) 40.00 42.00

6 Average Crushing Strength (N/sqmm) 41.00

7 Specified As Per I.S. 40.00 N/MM2


TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/ 22-23 /917 / PW/ANR


NAME OF DIVISION Public Work Division , Ahemadnagar
NAME OF SUBDIVISION #REF! Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR
8 Chapadgaon road MDR 101 @ Km 1/100 Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 9/15/2022
DATE OF TESTING 28/12/2017 TO 29/12/2017
WT. OF SAMPLE 19020.00 gm

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained %age Commulative %age of Specified limit


Designation in gm. Retained %age Retained passing (%age)
No.

1 80 mm 525 2.76 2.76 97.24 > 95

2 25 mm 18264 96.03 98.79 1.21 <2

3 Pan 231 1.21 100.00 0.00

Total 19020 100.00

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY #REF! Assist.Reaserch#REF!
Officer,
CHECKED BY #REF!
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/ 22-23 /917 / PW/ANR #REF! DATE:-
NAME OF DIVISION Public Work Division , Ahemadnagar
NAME OF SUBDIVISION #REF! Karjat
NAME OF WORK S.R. to bridge on SH 54 to Rashin Alsunde Nimbe Khatgaon Loni Masadpur to MDR 8 Chapadgaon road MDR 101 @ Km 1/100
Tal-Karjat Dist-Ahmednagar.
TYPE OF SAMPLE Hard Murum / Soft Murum.
DATE OF SAMPLE 9/15/2022
DATE OF TESTING 28/12/2017 TO 29/12/2017
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide Natura
Source and
Sample. comendium l Max
other details I.S Optimum
Plastic Plasticity for const. Of
No.
of sample Liquid moistu Dry C.B.R.
bond CI.No. sieve Determined Specified moisture C.B.R. soaked
limit limit Index re Den Unsocked
(13.1) size content
conten sity
t
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Not more 80mm 97.24 > 95


Non -- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm 1.21 <2

TESTED BY #REF! #REF!


Assist.Reaserch Officer,
CHECKED BY #REF!
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
01 @ Km 1/100

Remark

15

Control(P.W.),
hemadnagar .