You are on page 1of 130

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK

DIST. LABORATORY, AHMEDNAGAR


TEST DATA SHEET:DCASA-07

JOB NO. AHA/18-19/ 488 / PW/SNR


NAME OF DIVISION Public Work Divi. Sangamner
NAME OF SUBDIVISION P.W.SubDivision Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE 10 mm
DATE OF SAMPLE 9/24/2018
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 13679 gm (IS:383 Tab.2)

DATE OF TESTING 6/27/2018

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 0 0.00 0.00 100.00 100%
3 10 mm 9465 69.19 69.19 30.81 0-45%
4 4.75 mm 4125 30.16 99.35 0.65 0-10%
5 Pan 89 0.65 100.00 0
Total 13679 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING
WT. OF SAMPLE TAKEN gm

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 33.9 W1
2 50 mm 40 mm W2 27 W2
3 40 mm 25 mm W3 19.5 W3
4 25 mm 20 mm W4 13.5 W4
5 20 mm 16 mm W5 10.8 W5
6 16 mm 12.5 mm W6 8.55 W6
7 12.5 mm 10 mm W7 6.75 W7
8 10 mm 6.3mm W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari (R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/18-19/ 488 / PW/SNR


NAME OF DIVISION Public Work Divi. Sangamner
NAME OF SUBDIVISION P.W.SubDivision Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/24/2018

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 43278

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2178 2239
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in water


3
in gm
W3=W1-W2 1478 1539

Weight of saturated dry aggregate in


4
air in gm
W4 2251 2332

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 773 793

Weight of Oven dry aggregate in air in


6
gm
W6 2196 2278

7 Sp. Gravity W6/W5 2.84 2.87

8 Water Absorption (W4-W6)/W6 2.50% 2.37%

9 Average Sp. Gravity 2.86

10 Average Water Absorption 2.44%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA/18-19/ 488 / PW/SNR
NAME OF DIVISION Public Work Divi. Sangamner
NAME OF SUBDIVISION P.W.SubDivision Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/24/2018
DATE OF TESTING 43278

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
43 44
3 Weight retained on 2.36mm IS sieve after
15 blows in gm W3
297 299
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
12.65% 12.83%
(W2/W1)x100
6 Average Impact Value% age
12.74%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2891 2897
2 Weight of fines passing through 2.36mm
IS sieve in gm 356 356
W2
3 Weight retained on 2.36mm IS sieve in
gm 2535 2516
W3
4 Weight of sample in gm
W2+W3
2891 2872
5 Aggregate Crushing Value in % age
12.31% 12.29%
(W2/W1)x100
6 Average Crushing Value in % age
12.30%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/18-19/ 488 / PW/SNR LAB./NO./SNR:- DATE:-
NAME OF DIVISION P.W.SubDivision Sangamner
NAME OF SUBDIVISION P.W.Sub Division Akole-1
NAME OF WORK Concreting Sangavi To Dagadwadi Road Tal- Akole.

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/24/2018
DATE OF TESTING 9/24/2018

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%

20 MM 100.00 100%

1 12 mm Metal 10 MM 30.81 0-45%

4.75 MM 0.65 0-10%

Pan 0.00 0

TEST RESULTS OF COARSE AGGREGATES

Result Obtained
Sr. No. Type of Test Result Specified for WBM Remark
20 MM METAL Trap Laterite

1 Flakiness Index (Not more than) 15%

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DBWCE-18

BRICKS TEST
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8
Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE :-Bricks
DATE OF RECPT. OF SAMPLE 9/29/2018
DATE OF TESTING 29/09/2018 to 04/10/2018

WATER ABSORPTION TEST


% of water
Sr. S.S.D. Wt. of Brick W1 Oven Dried Wt. of Brick
Wt. of water (W1-W2) absorption=(W1- Limits
No. in gm W2 gm
W2)/W2 X 100
1 2635 2175 460 21.15%
For Ist Class 20 %
2 2638 2175 464 21.33%
Max.
3 2642 2180 462 21.19%
4 2644 2180 464 21.28%
For IInd Class 22 %
5 2640 2180 460 21.10%
Max.
Average 21.21%

CRUSHING STRENGTH TEST


Compressive Load in Compressive Strength in
Sr. Identification kN N/sqmm
Size of Brick Area of Brick Limits
No. Mark
Dry Wet Dry Wet
1 230x100X75 23000 70 3.04
For Ist Class Not Less
2 ……do…… 230x100X75 23000 74 3.22
Than 3.28 N/mm²
3 ……do…… 230x100X75 23000 72 3.13

4 ……do…… 230x100X75 23000 74 3.22


For IInd Class Not
5 ……do…… 230x100X75 23000 70 3.04 Less Than 2.95
N/mm²
Av. 3.13

Efflorescence

As there is 10 % perciptable residue or deposit on surface of brick after keeping both the ends of brick in water for 24 hours .
Hence effloerance is Slight

Reference : I.S.3495 1992,Part-I,II,& as per TP-04.

Tested by S.G. Kokate (L.A.)


Checked by Y.R.Chaudhari (R.A.)
Equipment used ;- C.T.M.Machine, Oven.
Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR

JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE;-


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub. Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101
@ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE :-Bricks
DATE OF RECEIPT OF SAMPLE 9/29/2018 DATE OF TESTING;- 29/09/2018 to 04/10/2018

TEST RESULT OF BRICKS


Water Absorption Crushing strength
Identification Remarks
Sr. No. Size of Bricks in cm. Specified Determined Specified Limit
Mark Determined
Limit Dry Wet Dry Wet
1 230x100X75 21.15% 3.04 For Ist Class For Ist Class
For Ist Class
Not Less Not Less
2 ……do…… 230x100X75 21.33% Not More 3.22 Than 4.37 Than 3.28
Than 20 %
3 ……do…… 230x100X75 21.19% 3.13 N/mm² N/mm²

4 ……do…… 230x100X75 21.28% 3.22 For IInd Class For Iind Class
For IInd Class
5 ……do…… 230x100X75 21.10% 3.04 Not Less Not Less
Not More
Than 3.93 Than 2.95
Than 22 %
Average 21.21% Average 3.13 N/mm² N/mm²

THE TEST RESULT OF BRICK EFFLORESCENCE

As there is 10 % perciptable residue or deposit on surface of brick after keeping both the ends of brick in water for 24 hours . Hence effloerance is Slight
Note :-The test result based on samples received in the Laboratory
Reference : :- I.S.3495 ( Part (I), (II) 1992

Tested by : S.G. Kokate (L.A.)


Checked by: Y.R.Chaudhari (R.A.) Assist.Reaserch Officer,
Equipment used :- CTM Machine , Oven. Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASA-07

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to
MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/29/2018
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 8983 gm (IS:383 Tab.2)

DATE OF TESTING 9/29/2018

I.S.Sieve Commulative
Wt.Retained %age Specified limit
Sr.No. Designation %age %age of passing
in gm. Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 263 2.93 2.93 97.07 85-100 %
3 10 mm 7081 78.83 81.75 18.25 0-20 %
4 4.75 mm 1458 16.23 97.99 2.01 0-5 %
5 Pan 181 2.01 100.00 0
Total 8983 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING
WT. OF SAMPLE TAKEN gm

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on guage size in
through IS least 200 pieces passing through guage
IS Sieve mm
Sieve
1 63 mm 50 mm W1 33.9 W1
2 50 mm 40 mm W2 27 W2
3 40 mm 25 mm W3 19.5 W3
4 25 mm 20 mm W4 13.5 W4
5 20 mm 16 mm W5 10.8 W5
6 16 mm 12.5 mm W6 8.55 W6
7 12.5 mm 10 mm W7 6.75 W7
8 10 mm 6.3mm W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = /

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R.Chaudhari (R.A.)

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to
MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar

TYPE OF SAMPLE :- 20 MM METAL


DATE OF SAMPLE 9/29/2018

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 43372

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate


1 suspended in water with basket in W1 2178 2239
water in gm

2 Weight of basket in water in gm W2 700 700

Weight of saturated aggregate in water


3
in gm
W3=W1-W2 1478 1539

Weight of saturated dry aggregate in


4
air in gm
W4 2251 2332

Weight of of water equal to the


5
volume of aggregate in gm
W5=W4-W3 773 793

Weight of Oven dry aggregate in air in


6
gm
W6 2196 2278

7 Sp. Gravity W6/W5 2.84 2.87

8 Water Absorption (W4-W6)/W6 2.50% 2.37%

9 Average Sp. Gravity 2.86

10 Average Water Absorption 2.44%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/29/2018
DATE OF TESTING 43372

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
340 343
2 Weight of fines passing through 2.36mm
IS sieve after 15 blowsin gm W2
43 44
3 Weight retained on 2.36mm IS sieve after
15 blows in gm W3
297 299
4 Weight of sample in gm
W2+W3
340 343
5 Aggregate Impact Value % age
12.65% 12.83%
(W2/W1)x100
6 Average Impact Value% age
12.74%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2891 2897
2 Weight of fines passing through 2.36mm
IS sieve in gm 356 356
W2
3 Weight retained on 2.36mm IS sieve in
gm 2535 2516
W3
4 Weight of sample in gm
W2+W3
2891 2872
5 Aggregate Crushing Value in % age
12.31% 12.29%
(W2/W1)x100
6 Average Crushing Value in % age
12.30%

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02

TESTED BY :- J.N.Meshram- (R.A)


CHECKED BY

Assist.Reaserch Officer,
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION P.W.Sub Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist-
Ahmednagar
TYPE OF SAMPLE :- 20 MM METAL
DATE OF SAMPLE 9/29/2018
DATE OF TESTING 9/29/2018

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified

40 MM 100 100%

20 MM 97.07 85-100%

1 20 MM METAL 10 MM 18.25 0-20%

4.75 MM 2.01 0- 5%

Pan 0.00 0

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV
Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 S-1 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 8.451 460 20.44

2 S-2 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 8.462 480 21.33 20.89 19.60

3 S-3 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 8.456 470 20.89

4 C-1 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 8.469 480 21.33

5 C-2 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 8.459 470 20.89 21.19 19.60

6 C-3 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 8.462 480 21.33

Reference I.S. 516-1999 CL.5.5. Assist.Reaserch Officer,


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes


Above 700
Cross Average Reqd.
Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-20 9/14/2018 11/1/2018 48 150x150x150 22500 8.502 490 21.78

2 A-2 M-20 9/14/2018 11/1/2018 48 150x150x150 22500 8.499 500 22.22 21.93 21.00

3 A-3 M-20 9/14/2018 11/1/2018 48 150x150x150 22500 8.525 490 21.78

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 10/22/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 690 30.67

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 870 38.67 32.15 30.00 e

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 610 27.11

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 780 34.67

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 690 30.67 31.85 30.30 f

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 680 30.22

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 F-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 630 28.00

2 F-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 690 30.67 30.52 30.15 g

3 F-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 740 32.89

4 G-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 690 30.67

5 G-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 700 31.11 31.41 30.00 h

6 G-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 730 32.44

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
Dist.Laboratory,Ahmednagar
Assist.Reaserch Officer,
Vigilance & Quality
Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 10/22/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 H-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 660 29.33

2 H-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 790 35.11 32.15 30.00 i

3 H-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 720 32.00

4 I-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 690 30.67

5 I-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 750 33.33 31.85 30.00 j

6 I-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 710 31.56

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 710 31.56

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 690 30.67 32.59 30.00 k

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 800 35.56

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 680 30.22

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 710 31.56 32.30 30.00 l

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 790 35.11

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
Control(P.W.),
Dist.Laboratory,Ahmednagar
Assist.Reaserch Officer,
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 10/22/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 225 10.00

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 225 10.00 10.00 10.00 m

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 225 10.00

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 225 10.00

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 225 10.00 10.00 20.00 n

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 225 10.00

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 15.00 o

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 16.00 p

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


:- J.N.Meshram (R.A) Assist.Reaserch Officer,
TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 10/22/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 17.00 q

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 18.00 r

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


:- J.N.Meshram (R.A) Assist.Reaserch Officer,
TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 10/22/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 10/22/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 10/22/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 27.00 a

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 28.00 b

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018 DATE OF TESTING 12/27/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 S-1 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 460 20.44

2 S-2 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 480 21.33 20.89 19.60

3 S-3 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 470 20.89

4 C-1 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 480 21.33

5 C-2 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 470 20.89 21.19 19.60

6 C-3 M-20 12/2/2018 12/27/2018 25 150x150x150 22500 480 21.33

Reference I.S. 516-1999 CL.5.5. Assist.Reaserch Officer,


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis
TYPE OF SAMPLE :-Con. Cubes
DATE OF RECEIPT OF SAMPLE 12/20/2018 DATE OF TESTING 12/27/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-20 9/14/2018 11/1/2018 48 150x150x150 22500 490 21.78

2 A-2 M-20 9/14/2018 11/1/2018 48 150x150x150 22500 500 22.22 21.93 21.00

3 A-3 M-20 9/14/2018 11/1/2018 48 150x150x150 22500 490 21.78

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 690 30.67

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 870 38.67 32.15 30.00 e

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 610 27.11

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 780 34.67

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 690 30.67 31.85 30.30 f

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 680 30.22

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 12/20/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 F-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 630 28.00

2 F-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 690 30.67 30.52 30.15 g

3 F-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 740 32.89

4 G-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 690 30.67

5 G-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 700 31.11 31.41 30.00 h

6 G-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 730 32.44

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 H-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 660 29.33

2 H-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 790 35.11 32.15 30.00 i

3 H-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 720 32.00

4 I-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 690 30.67

5 I-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 750 33.33 31.85 30.00 j

6 I-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 710 31.56

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 12/20/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 710 31.56

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 690 30.67 32.59 30.00 k

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 800 35.56

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 680 30.22

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 710 31.56 32.30 30.00 l

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 790 35.11


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00 10.00 10.00 m

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00 10.00 20.00 n

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 12/20/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 15.00 o

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 16.00 p
16.00 p

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 17.00 q

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

18.00 r
5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 18.00 r

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 12/20/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09


4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 21.00 u
21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 12/20/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

23.00 w
2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 12/20/2018
Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of Cross sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in sqmm Strenght Strenght h
mix Days kN inN/sqmm
inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14
1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 12/20/2018

Test Results of Compressive Strength of C.C.Cubes

Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of Cross sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in sqmm Strenght Strength in
Days kN inN/sqmm
inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 27.00 a

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 28.00 b

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY AHMEDNAGAR

Job No. AHA/22-23 / 926 / PW/ANR NO.LAB / / 2022


Office of Assistant Research Officer,
Vigilance & Quality Control ( P.W.D)
District laboratary Ahmednagar,
Dated- / 2022
To,
Sub Divisional Engineer
P.W.Sub Division
Karjat

Subject :-Testing of Materials

Name of Work:- S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur
to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist-
Ahmednagar
Referance:- Your letter No Camp. Dated 15/03/2022.

With referance to above letter, the test results for the work cited above
are enclosed herewith for your information please.

Testing charges amounting Rs. 2920 are received on online payment receipt
Transaction No 1895306723 Dated 12/09/2022. for the same Is enclosed herewith .

Assistant Research Officer,


Vigilance & Quality control(P.W.D),
District laboratory,Ahmednagar..

Copy :- M/s Bajarangbali Construction Pp Mohan Damoder Godse At Therwadi Post Benwadi Tal. Karjat Dist Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY AHMEDNAGAR
Checklist for acceptance of sample.
1) Name and address of organization Sub Divisional Engineer P.W.Sub Division Karjat
2) Name of agency M/s Bajarangbali Construction Pp Mohan Damoder Godse At Therwadi
Post Benwadi Tal. Karjat Dist Ahmednagar
3) Details of samples.
i)Name of work S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
ii)Material/Location.
iii)Quantity
4) Date of receipt of sample. 15/09/2022.
5) Whether samples are accompained with letter Yes
if yes,then give letter No. and date Camp. Dated 15/03/2022.
if no, samples are not accepted
6) Details of tests to be conducted and testing charges
D.S.R. Item
Sr. No. Materialas Name of tests No. of tests Rate Amount
No.

2 Cr.metal for Concrete Flaki, seive 2 1 1540 1540

3 Sand Fm, Silt Cont 11 1 1380 1380

7) Whether samples are marked with lables Y/N Yes Total 2920
by the organisation
if no samples are not accepted
8) Whether the quantity of samples are Y/N Yes
adequate for testing .
9) Whether testing facility is available in the lab Y/N Yes
10) Whether serviceble and calibrated equipment Y/N Yes
are available
11) Whether trained person available for testing. Y/N Yes
11) Customer requirement if any, Y/N
13) Details of receipt of testing charges Transaction No 1895306723
Date 12/09/2022.
Rs. 2920
Recived by Approved by

R.A.
Assistant Research officer
District Laboratory Ahemadnagar.

14) If approved give job no. AHA/22-23 / 926 / PW/ANR


VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat
Dist- Ahmednagar
TYPE OF SAMPLE Cr.Metal For Concrete
DATE OF SAMPLE 15/09/2022.
SIEVE ANALYSIS FOR 20 MM WBM METAL
WT. OF SAMPLE TAKEN 8882 gm (IS:383 Tab.2)

DATE OF TESTING 16/09/2022 to 20/09/2022

I.S.Sieve Commulative
%age Specified limit
Sr.No. Designation Wt.Retained in gm. %age %age of passing
Retained (%age)
No. Retained
1 40 mm 0 0 0 100 100%
2 20 mm 247 2.78 2.78 97.22 85-100 %
3 10 mm 7059 79.48 82.26 17.74 0-20 %
4 4.75 mm 1427 16.07 98.32 1.68 0-5 %
5 Pan 149 1.68 100.00 0
Total 8882 100.00

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]
DATE OF TESTING:- 16/09/2022 to 20/09/2022
WT. OF SAMPLE TAKEN:- 4601

SIZE OFAGGREGATE
Thickness of
Passsing Wt. of fraction consisting at Wt. of aggregate in each fraction
Sr.No. Retained on IS guage size in
through IS least 200 pieces passing through guage
Sieve mm
Sieve
1 63 MM 50 MM W1 33.9 W1
2 50 MM 40 MM W2 27 W2
3 40 MM 25 MM W3 19.5 W3
4 25 MM 20 MM W4 13.5 W4
5 20 MM 16 MM W5 10.8 W5
6 16 MM 12.5 MM W6 8.55 W6
7 12.5 MM 10 MM W7 6.75 W7
8 10 MM 6.3 MM W8 4.89 W8
TOTAL W W*
FLAKINESS INDEX (W*/W)X100 = / 15.07%

:-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R.Chaudhari (R.A.)
Assist.Research Officer,

Vigilance & Quality Control(P.W.D),


Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat
Dist- Ahmednagar
TYPE OF SAMPLE Cr.Metal For Concrete
DATE OF SAMPLE 15/09/2022.

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

DATE OF TESTING 16/09/2022 to 20/09/2022

Sr.No. Perticular Trial-1 Trial-2

Weight of saturated aggregate suspended in


1
water with basket in water in gm
W1 2150 2160

2 Weight of basket in water in gm W2 700 700

3 Weight of saturated aggregate in water in gm W3=W1-W2 1450 1460

Weight of saturated dry aggregate in air in


4
gm
W4 2181 2222

Weight of of water equal to the volume of


5
aggregate in gm
W5=W4-W3 731 762

6 Weight of Oven dry aggregate in air in gm W6 2130 2200

7 Sp. Gravity W6/W5 2.91 2.89

8 Water Absorption (W4-W6)/W6 2.39% 1.00%

9 Average Sp. Gravity 2.90

10 Average Water Absorption 1.70%

REFERANCE :-IS 2386 PART III 1997.

TESTED BY S.G. Kokate (L.A.)


CHECKED BY Y.R. Chaudhari (R.A.)

Assist.Research Officer,
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat Dist-
Cr.Metal ForAhmednagar
Concrete
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022

IMPACT VALUE TEST(I.S.2386-1997)

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
341 345
2 Weight of fines passing through 2.36mm IS sieve
after 15 blowsin gm W2
45 46
3 Weight retained on 2.36mm IS sieve after 15
blows in gm W3
296 299
4 Weight of sample in gm
W2+W3
341 345
5 Aggregate Impact Value % age
13.20% 13.33%
(W2/W1)x100
6 Average Impact Value% age
13.26%

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )

Sr.No. Perticular Trial-1 Trial-2


1 Total weight of sample in gm
W1
2751 2755
2 Weight of fines passing through 2.36mm IS sieve
in gm 391 393
W2
3 Weight retained on 2.36mm IS sieve in gm
2360 2516
W3
4 Weight of sample in gm
W2+W3
2751 2909
5 Aggregate Crushing Value in % age
14.21% 14.26%
(W2/W1)x100
6 Average Crushing Value in % age
14.24%
REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997
Crushing Test : TP-02
TESTED BY P.R. Darade, Sect.Engr
CHECKED BY A.R.Anand, ARO
Assist.Research Officer,

Vigilance & Quality Control(P.W.D),


Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100
tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Cr. Metal For Concrete
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


% Passing
Sr. No. Type of Samples Size of Sieve(mm) Remark
Determined Specified
20 mm 100.00 100%
10 mm 97.22 85-100%

1 Cr. Metal For Concrete 4.75 mm 17.74 0-20%


Pan 1.68 0- 5%

Total 0.00 0

TEST RESULT SHEET : RCA-03


TEST RESULTS OF COARSE AGGREGATES
Result Obtained
Result Specified for WBM
Sr. No. Type of Test Remark
Cr. Metal For Concrete Trap Laterite

1 Flakiness Index (Not more than) 15.07%

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV

TESTED BY P.R. Darade, Sect.Engr


CHECKED BY A.R.Anand, ARO Dist.Laboratory,Ahmednagar
Vigilance & Quality Control(P.W.D),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

TEST OF FINE AGGREGATE i.e. SAND


JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Jamkhed
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100
tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE :-Cr. Sand
DATE OF REC.OF SAMPLE 15/09/2022.
Fineness Modulus(F.M)
WT. OF SAMPLE TAKEN 1000 gm

Sr.No. I.S.Sieve Weight of % Wt. Cummulati Fineness Specified limit (%age)


Designatio Sand Retained Retained on ve % Modulus
n No. on each in gm. each Sieve. Retained
on each
Concrete
1 4.75 mm 0 0.00 0.00 Total(A)
100 2.6 to 3.6
2 2.36 mm 209 20.90 20.90
i.e.
3 1.18 mm 187 18.70 39.60
3.14 Masonry mortar
4 600mic 312 31.20 70.80
Max. 3.0
5 300mic 169 16.90 87.70
6 150mic 74 7.40 95.10
Plaster
7 Pan 49 4.90 0
Total 1000 TOTAL(A) 314.10 Max. 1.6

SILT CONTENT (fine Aggregate)


DATE OF TESTING 16/09/2022 to 20/09/2022

Sr.No. PERTICULARS Trial-1 Trial-2

1 Weight of oven dried sand taken in gm …(W1) 1000 1000

Weight of sand after washing through 75 micron sieve & oven


2 943 945
drying in gm…………… (W2)

W1-W2 x100
3 Silt content = 5.70 5.50
W1

Average 5.60

Reference : Fineness Modulus-As per P.W.Handbook Chapter I, Material CL.8

Silt Content-As per I.S 2386 Part-I-1997, CL.3.4


Tested by P.R. Darade, Sect.Engr
Checked by A.R.Anand, ARO Asst.Research Officer,
Vigilance & Quality Conntrol (P.W.D),
Equipment used : I.S.Sieves Dist.Laboratory,Ahmednagar
31 39 38 35 38 0 0 90 70 0 0 0
274 221 244 225 233 185 140 152 145 135 125 160
241 306 232 235 250 195 250 240 235 240 245 240
224 172 195 200 215 320 270 245 260 265 265 280
122 123 142 170 180 175 210 130 135 240 220 200
55 73 119 105 70 75 95 103 125 95 105 75
53 66 30 30 14 50 35 40 30 35 40 45
1000 1000 1000 1000 1000 1000 1000 1000 1000 1010 1000 1000

1 2 1 2 1 2

1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1004 1000

968 969 962 963 970 972 972 968 972 969 980 975
0 95 0 0 0 0 0 90 85 85 42
120 170 120 150 150 180 190 155 160 165 296
235 230 235 255 260 190 255 305 320 255 223
255 245 280 295 265 310 265 165 150 250 161
240 130 240 205 210 180 138 140 135 120 112
105 85 85 70 85 90 112 110 110 90 91
40 45 40 25 30 50 40 35 40 35 75
995 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

1 2 1 2 1 2

1003 1002 1007 1005 1003 1000 1004 1005 1000 1002 1000 1002

982 980 981 980 979 979 981 980 975 982 978 980
1 2 1 2 1 2

1007 1005 1002 1004 1005 1010 1004 1005 1005 1010 1005 1002

982 978 977 980 977 980 970 975 977 980 977 982
1 2 1 2 1 2

1002 1005 1000 1010 1002 1003 1003 1004 1000 1000

970 980 977 980 976 978 975 976 967 966
1 2 1 2 1 2
1 2 1 2 1 2
1 2 1 2 1 2
1 2 1 2 1 2
1 2 1 2 1 2
1 2 1 2 1 2
1 2 1 2
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road,
MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Cr.Sand
DATE OF RECEIPT OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022
TEST RESULT OF SAND
Specified Limits
Sr. No. Type of test Results obtained
Concrete Work Road Work

1 Silt & Clay Content (%) 5.60 Not more than 4% Not more than 10%

i)2.6 to 3.6 for con work


2 Finess Modulus 3.14 ii)Upto 3.0 for masonarywork
iii)1.6 for plaster
Note : The test results are based on smaples received in Laboratory.
Reference : IS 383-1993, IS 2386 Part(I)1963 &P.W.Handbook CH-, material CL.8
Tested by : P.R. Darade, Sect.Engr
Checked by: A.R.Anand, ARO Assist.Research Officer,
Vigilance & Quality Control(P.W.D)
Equipment used : I.S.Sieves Dist.Laboratory, Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Jamkhed
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR
8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar

TYPE OF SAMPLE Hard Murum


DATE OFRECEIPT OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022
WT. OF SAMPLE

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained in %age Commulative %age of Specified limit


Designation gm. Retained %age Retained passing (%age)
No.

1 80 mm 0 0.00 0.00 100.00 > 95

2 25 mm 11271 98.27 98.27 1.73 <2

3 Pan 199 1.73 100.00

Total 11470

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample could not be
4 Sample tends to slide on
WEIGHT OF DISH+DRY SOIL IN gm W2 rolled into thread of 3
surface of cup,even though the
mm diameter. Hence
5 test is repeated.Hence Liquid
WEIGHT OF WATER IN gm W3=W1-W2 Plastic Limit could not
Limit could not be obtained.
be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY P.R. Darade, Sect.Engr Assist.Research Officer,
CHECKED BY A.R.Anand, ARO
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR NO./LAB./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100
tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium C.B.R
other details I.S Natural Optimum Remark
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry . C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soake Unsocked
(13.1) size content content
d
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Not more 80mm 97.22 > 95


-- -- -- -- -- --
1 Hard Murum -- -- than 4% for
H.M. 25mm 1.69 <2

TESTED BY P.R. Darade, Sect.Engr Assist.Research Officer,


CHECKED BY A.R.Anand, ARO
Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahemadnagar .
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY, AHMEDNAGAR

CEMNT TEST
Job No. AHA/22-23 / 926 / PW/ANR
Name of Division Public Work Division Ahmednagar
Name of Sub-Division P.W.SubDivision Jamkhed
Name of Work S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8
Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
Date of Testing 16/09/2022 to 20/09/2022
Details of Sample Ultratech - 53- Grade
TEST DATA SHEET : DCCT-01
Consistency
Wt. of cement Vol. of water Percentage of
Trial Reading on Vicat app. In
taken for test in added to dry water added Consistancy Remark
No. (mm)
gm cement in cc in dry cement
2 400 120 30.00 8 Hence Consistancy is
3 400 122 30.50 5
29.75
4 400 119 29.75 6

TEST DATA SHEET : DCCT-02


Setting Time
Requirement of Actual water A B C Limits as per IS Ref.
water Requirement
Final Initial Final Initial Final
0.85 ×P=V Time for
Sr. Wt. of cement in Initial Setting Setting Setting Setting Setting Setting
P=Std. V×400 adding water
No. gms 100 Time Hr. Time Time Time Time Time
Consistency in cement Hr.
Min. (B-A) Hr. Min (Min) (Min.) (Min) (Min.)
Min.
(C-A)
1 2 3 4 5 6 7 8 9

× 400/
0.85× 29.8 25.29 1:39 5:42 30 600
100
1 400 gms 10:00 11:39 15:42
=
25.29 = 101.15 99 342 Minimum Maximum

Min Min
TEST DATA SHEET : DCCT-03
Fineness by Sieving

Wt. of cement on 90
Wt. of cement Residue in
Sr. Time of Sieving mic. Sieve retained
Trial No. before sieving % observed Average % Residue Specified Remarks
No. in Min. after sieving in gm.
in gm(W1) = 5/3×100
(W2)

1 2 3 4 5 6 7 8
1 1 100 gms 15 minutes 3.00 5.00
5% Max for PPC
2 2 100 gms 15 minutes 4.00 5.00 5.33
10% Max for OPC
3 3 100 gms 15 minutes 5.00 6.00

Reference : Consistency- Methods of Physical tests for hydraulic cement.As per I.S 4031-1997 CL.6
Setting Time- As per I.S 4031-1998 CL.7
Fineness-As per I.S 4031-1996 CL.8

Tested by : P.R. Darade, Sect.Engr Assist.Research Officer,


Checked by : A.R.Anand, ARO Vigilance & Quality Control(P.W.D),
Equipment used :Vicat apparatus and Vicat mould,I.S sieve. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
Cement Tests
Job No. AHA/22-23 / 926 / PW/ANR
Name of Division Public Work Division Ahmednagar
Name of Sub-Division P.W.SubDivision Jamkhed
Name of Work
S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon
road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar

Date of Testing 16/09/2022 to 20/09/2022


Details of Sample Ultratech - 53- Grade

TEST DATA SHEET : DCCT-04


Specific gravity
Sr.No. Description Flask 1 flask 2 Dummy Flask Limit
1 Wt. of cement taken for test in gm 64.00 64.00 -
Initial Level of liquid (Kerosene) in flask in ml
2 0.00 0.00 0
Final Level of liquid (Kerosene) in flask in ml
3 20.30 20.40 0
Increase in level of Dummy Flask due to temp
4 0.00 0.00 0 3.10 to 3.15

Correct volume of liquid after appling temp.


5 correction 20.30 20.40 -

6 Specific Gravity 3.15 3.14 -


7 Av.Specific Gravity 3.14 -

TEST DATA SHEET : DCCT-05


Soundness of cement
Sr. Wt. of cement Requirement of water Actual water requirement in CC Distance separating the
No. taken for test in V =0.78 x P = (V X 200) indicater point in mm Limits as per IS Ref.
gm
P=Std. consistancy 100 Initial Final Diff.
14 17 3
0.78× 29.75 23.21 × 200 16 19 3 Expansion Not More
1 200 gms
= 23.21 = 46.41 15 18 3 Than 10 mm

Say 46 CC Average 3

TEST DATA SHEET : DCCT-06


Compressive Strength Test
Wt. of water to Curing Comp Requireme
Wt. of Wt. of Comp Av.Comp
Sr. Normal be added in Date of Date Of period of Strength nt as per
Consiste Cement Standard sand Strength Strength In
No ncy (P)% CC = casting testing Mortor load In IS in
in gms in gms In N/mm² N/mm²
(P/4+3)8 cubes kN N/mm²
1 2 3 4 5 6 7 8 9 10 11 12
1 29.75 200 gms 600 gms 83.5 9/16/2022 9/19/2022 3 143 28.60
2 29.75 200 gms 600 gms 83.5 9/16/2022 9/19/2022 3 141 28.20 28.27 27
3 29.75 200 gms 600 gms 83.5 9/16/2022 9/19/2022 3 140 28.00
4 29.75 200 gms 600 gms 83.5 9/16/2022 9/23/2022 7 192 38.40
5 29.75 200 gms 600 gms 83.5 9/16/2022 9/23/2022 7 189 37.80 38.13 37
6 29.75 200 gms 600 gms 83.5 9/16/2022 9/23/2022 7 191 38.20

Reference : Specific Gravity-As per I.S 4031-1992 CL.13


Soundness-As per I.S 4031-1996 CL.5
Comp. strength-As per I.S 4031-2000 CL.8

Tested by : P.R. Darade, Sect.Engr Assist.Research Officer,


Checked by : A.R.Anand, ARO Vigilance & Quality Control(P.W.D),
Equipment used :Std. Lechatelier flasks,Chatelier Test apparatus and CTM Dist.Laboratory,Ahmednagar
Machine.
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE;-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Jamkhed
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8
Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Ultratech - 53- Grade
DATE OF RECEIPT OF SAMPLE 9/7/2022 DATE OF TESTING;- 16/09/2022 to 20/09/2022
TEST RESULT OF CEMENT
Results obtained
Sr. No. Type of test Specified Limits
Sample-1
1 Fineness (%) 5.33 10% for OPC 5% for PPC
2 Setting Time(Min)
Initial 99.00 Not less than 30 minutes.
Final 342.00 Not More than 600 minutes.
3 Compresive Strength in N/sqmm Curing Period 33 Grade 43 Grade 53Grade
For 3Days 28.27 For 3 Days 16 N/mm² 23 N/mm² 27 N/mm²
For 7Days 38.13 For 7 Days 22 N/mm² 33 N/mm² 37 N/mm²
For 28Days ……… For 28 Days 33 N/mm² 43 N/mm² 53 N/mm²
Soundness by Le-Chateliar Apparatus
4 3.00 Expansion not more than 10 mm
mm
5 Specific Gravity 3.14 3.10 to 3.15
6 Std. Consistancy 30.25 Not Specified

Note : The test results are based on smaples received in Laboratory.

Reference : IS 4031 Part (I)1996 , IS 4031 Part (V)1998, IS 4031(VI)1992.


Tested by : P.R. Darade, Sect.Engr
Checked by: A.R.Anand, ARO Assist.Research Officer,

Equipment used : Vicat Apparatus, Lechatelier Apparatus, CTM Vigilance & Quality Control(P.W.D),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR

TEST DATA SHEET:DCASA-07

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to
MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar

TYPE OF SAMPLE :- 40 MM WBM METAL.


DATE OF RECPT. OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022
SIEVE ANALYSIS FOR METAL
WT. OF SAMPLE TAKEN :- 10120 SAMPLE-1

Sr.No. Wt.Retained in % Retained Commulative % % of passing Specified limit


I.S.Sieve gm. Retained (%)
Designation.
1 60 mm 0 0 0 100 100%

2 40 mm 6258 61.84 61.84 38.16 35-70 %

3 12.5 mm 3576 35.34 97.17 2.83 0-5 %

4 PAN 286 2.83 100.00 0.00

Total 10120

TEST DATA SHEET:DCAFE-14

FLAKINESS INDEX OF COARSE AGGREGATE FOR CONCRETE


[ IS :2386 PART I 1997 ]

SIZE OFAGGREGATE
Thickness of Wt. of aggregate in each
Passsing Wt. of fraction consisting at least
Sr.No. Retained on IS 200 pieces guage size in fraction passing through
through IS mm guage
Sieve
Sieve

1 63 mm 50 mm W1 0 33.9 W1 0

2 50 mm 40 mm W2 12652 27 W2 999

3 40 mm 25 mm W3 1012 19.5 W3 821

4 25 mm 20 mm W4 0 13.5 W4 0

5 20 mm 16 mm W5 0 10.8 W5 0

6 16 mm 12.5 mm W6 0 8.55 W6 0

7 12.5 mm 10 mm W7 395 6.75 W7 96

8 10 mm 6.3mm W8 0 4.89 W8 0

TOTAL W 14059 W* 1916

Flakiness Index = (W*/W)× 100 = 14059 / 1916 .= 13.63

REFERANCE :-IS 2386 PART I, MOST 2000, IS 383, PWD STD. SPECIFICATION
TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance
& Quality Control(P.W.),
Dist.Laboratory,Ahmednagar

Vigilance & Quality Control(P.W.),


Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCAI-11

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahemadnagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK
S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to
MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE 40 MM WBM METAL
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022

IMPACT VALUE TEST(I.S.2386-1997)


METAL-1
40 MM METAL
Sr.No. Particular
Trial-1 Trial-2

1 Total weight of sample in gm . (W1) 346 348

2 Weight of fines passing through 2.36mm IS sieve after 15 blows i (W2) 49 51

3 Weight retained on 2.36mm IS sieve after 15 blows in gm . (W3) 297 297

4 Weight of sample in gm . (W2+W3) 346 348

5 Aggregate Impact Value . W2/W1×100 14.16 14.66

6 Average Impact Value In % . 14.41

TEST DATA SHEET:DCACR-12

CRUSHING VALUE TEST(I.S.2386 IV 1997 )


METAL-1
40MM METAL
Sr.No. Particular
Trial-1 Trial-2

1 Total weight of sample in gm . (W1) 2769 2777

2 Weight of fines passing through 2.36mm IS sieve in gm . (W2) 427 428

3 Weight retained on 2.36mm IS sieve in gm. (W3) 2342 2349

4 Weight of sample in gm . (W2+W3) 2769 2777

5 Aggregate Crushing Value in % . W2/W1×100 15.42 15.41

6 Average Crushing Value in % 15.42

REFERANCE Impact Test :-TP-02, IS 2386 (PART IV)-1997


Crushing Test : TP-02
Assist.Reaserch Officer,
TESTED BY S.G. Kokate (L.A.)
Vigilance
CHECKED BY Y.R. Chaudhari (R.A.) & Quality Control(P.W.),
EQUIPMENT USED :- CTM Machine & Impact Machine Dist.Laboratory,Ahmednagar

Vigilance & Quality Control(P.W.),


Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET:DCASP&Wa-08

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to
MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar

TYPE OF SAMPLE 40 MM WBM METAL


DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

METAL-1
40 MM METAL
Sr.No. Particular
Trial-1 Trial-2
Weight of saturated aggregate suspended in water with basket
1 (W1) 2210 2141
in water in gm.

2 Weight of basket in water in gm. (W2) 700 700

3 Weight of saturated aggregate in water in gm. W3=W1-W2 1510 1441

4 Weight of saturated dry aggregate in air in gm. (W4) 2300 2205

5 Weight of of water equal to the volume of aggregate in gm. W5=W4-W3 790 764

6 Weight of Oven dry aggregate in air in gm . (W6) 2264 2180

7 Specific Gravity . W6/W5 2.87 2.85

8 Water Absorption. (W4-W6)/W6 1.590 1.147

9 Average Sp. Gravity 2.86

10 Average Water Absorption 1.37

REFERANCE :-IS 2386 PART III 1997.


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.)
EQUIPMENT USED :- CTM Machine & Impact Machine Assist.Reaserch Officer,

Vigilance & Quality Control(P.W.),


Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF SUBDIVISION Sub Divisional Engineer Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km
1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- 40 MM WBM Metal
LOCATION OF SAMPLE :- -----
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022

TEST RESULTS OF COURSE AGGREGATE FOR SIEVE ANALYSIS


Sr. No. Type of Samples Size of Sieve(mm) % Passing Remark

Determined
Specified
Sample 1

60 MM 100 100%

1 40mm WBM Metal 40 MM 38.16 35-70 %

12.5 MM 2.83 0-5 %

Assist.Reaserch Officer,
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF SUBDIVISION Sub Divisional Engineer Parner
S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km
NAME OF WORK 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE 40 MM WBM Metal
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 16/09/2022 to 20/09/2022
TEST RESULTS OF COARSE AGGREGATES
Mechanical Properties- Concrete Aggregates

Results Obtained Specified Limit


Concrete Work WBM
Sr. No. Type of Test 40 mm Remarks
WBM Metal I Wearing Non Wearing BT work
Trap Laterite
Surface surface

1 2 3 4 5 6 7 8 9
Impact Value (Not more than) 30% 45% 40% - 30%
1 14.41
Light &Heavy
Crushing Value (Not more than) 30% 45% - 12% 23% & 17%
2 15.42 Traffic

Water Absorption (Not more than) 5% 5% 5% - 2%


3 1.37
Specific Gravity - - - - -
4 2.86
Flakiness Index /Elongation Index
(Not more than) 30% 30% 15% - 30%
7 13.63

Note The test results are based on sample received in Laboratory


Referance IS 2386 Part I , III ,IV Dist.Laboratory,Ahmednagar
TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @
Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Gray Blakish Rubble.
DATE OF REC. OF SAMPLE 1/28/2019
DATE OF TESTING 28/01/2019 to 31/01/2019

TEST RESULTS OF BUILDING STONE/RUBBLE

% Water Absorption Apparent Compressive Strength (N/sqmm) Impact Value(%) Crushing Value(%)
Sourse &
Sr.No. Specific
Other Details
Gravity
Deter
Specified Determined Specified Determined Specified Specified Determined
mined
Vide Std.
Specification
Gray Blakish
1 Clause A 4.07 2.85 Vide IS 1597 Part-1 1967 40.00N/mm2 42.50 Max.30% -------- Max.30%
Rubble. 8.1Not more
than 5%

Note :-The test result based on samples received in the Laboratory


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R. Chaudhari (R.A.) Assist.Reaserch Officer,
Equipment used :- CTM Machine. Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
aon road, MDR.101 @

Remarks
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE :-Rubble
Karjat Dist- Ahmednagar
DATE OF SAMPLE 1/28/2019
DATE OF TESTING 28/01/2019 to 31/01/2019

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

Sr.No. Particular Trial-1 Trial-2


Weight of saturated dry aggregate in air
1 in gm(Passing through 20mm sieve & B 1164 1188
retained on 10mm sieve )
Quantity of water added in 1000ml jar
2 containing the test pieces C 609 599
Weight of Oven dry aggregate in gm
3 A 1119 1141

4 Apperant Sp. Gravity A/(1000-C) 2.86 2.85


5 Water Absorption (B-A)/A x 100 4.021 4.119
6 Average Sp. Gravity 2.85
7 Average Water Absorption 4.07

CRUSHING STRENGTH OF BUILDING STONE

Sr .No. Particular Trial-1 Trial-2

1 Identificaton Mark ………… …………

2 Size of specimen 100x100x100 100x100x100

3 C/S Area perpendicular to load sqmm 10000.00 10000.00

4 Crushing Load in (kN) 410.00 400.00

5 Crushing Strength (N/sqmm) 43.00 42.00

6 Average Crushing Strength (N/sqmm) 42.50

7 Specified As Per I.S. 40.00 N/MM2

TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y.R. Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK
S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101
@ Km 1/100 tal- Karjat Dist- Ahmednagar

TYPE OF SAMPLE Ultatech 53 Grade


DATE OF RECEIPT OF SAMPLE 2/16/2019
DATE OF TESTING 16/02/2019 to 25/02/2019
-
TEST RESULT OF CEMENT
Results obtained
Sr. No. Type of test Specified Limits
Sample-1 Sample-2 Sample-3

1 Fineness (%) 5.00 ……. ……. 10% for OPC 5% for PPC
2 Setting Time(Min)
Initial 70 min ……. ……. Not less than 30 minutes.
Final 420 min ……. ……. Not More than 600 minutes.
3 Compresive Strength in N/sqmm Curing Period 33 Grade 43 Grade 53Grade
For 3Days 28.00 ……. ……. For 3 Days 16 N/mm² 23 N/mm² 27 N/mm²
For 7Days 38.13 ……. ……. For 7 Days 22 N/mm² 33 N/mm² 37 N/mm²
For 28Days ……. ……. For 28 Days 33 N/mm² 43 N/mm² 53 N/mm²
Soundness by Le-Chateliar
4 5 ……. ……. Expansion not more than 10 mm
Apparatus mm
5 Specific Gravity 3.14 ……. ……. 3.10 to 3.15
6 Std. Consistancy 30.8 ……. ……. Not Specified

Note : The test results are based on smaples received in Laboratory.

Reference : IS 4031 Part (I)1996 , IS 4031 Part (V)1998, IS 4031(VI)1992.


Tested by : S.G. Kokate (L.A.)
Assist.Reaserch Officer,
CheckedY.R.
by: Chaudhari (R.A.) Vigilance &
Equipment used : Vicat Apparatus, Lechatelier Apparatus, CTM Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCCT-01
Cement Tests
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmed

SAMPLE DETAILS Ultatech 53 Grade


DATE OF RECEIPT OF SAMPLE 2/16/2019
DATE OF TESTING 16/02/2019 to 25/02/2019
Consistency

Tral Wt. of cement taken for test in Vol. of water added to Percentage of water
Reading on Vicat app. In (mm) Consistancy Remark
No. gm dry cement in cc added in dry cement
1 400 119 29.8 11 Hence Consistancy is
2 400 124 31.0 4 30.75
3 400 123 30.8 6

TEST DATA SHEET : DCCT-02


Setting Time

Requirement of water Actual water Requirement A B C Limits as per IS Ref.


0.85 V×400 Initial Final
×P=V P=Std. Final
Sr. No. Wt. of cement in gms Time for adding Initial Setting Final Setting Initial Setting Setting Time Setting Setting Time
Consistency 100 Time (Min) Time (Min.)
water in cement Time Hr. Time Hr. (Min.)
Hr. Min. Min. (B-A) Min (C-A) (Min)

1 2 3 4 5 6 7 8 9

0.85× 30.8 26.1375 × 400/100 1:10 7:00 30 600


1 400 gms 10:30 11:40 17:30
= 26.1375
= 104.55 70 min 420 min Minimum Maximum

Reference : Consistency- Methods of Physical tests for hydraulic cement.As per I.S 4031-1997 CL.6
Setting Time- As per I.S 4031-1998 CL.7
Tested by : S.G. Kokate (L.A.)
Checked by : Y.R. Chaudhari (R.A.) Assist.Reaserch Officer,
Vigilance
Equipment used : Vicat apparatus and Vicat mould. & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCCT-03
Cement Tests
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmed

TYPE OF SAMPLE Ultatech 53 Grade


DATE OF RECEIPT OF SAMPLE 2/16/2019
DATE OF TESTING 16/02/2019 to 25/02/2019
Fineness by Sieving

Wt. of cement on 90 mic. Residue in %


Wt. of cement before sieving
Sr.No. Trial No. Time of Sieving in Min. Sieve retained after sieving observed=5/3× Average % Residue Specified Remarks
in gm(W1) 100
in gm.(W2)
1 2 3 4 5 6 7 8
1 1 100 gms 15 minutes 6.00 6.00
2 2 100 gms 15 minutes 5.00 5.00 5% Max for PPC 10%
5.00
Max for OPC
3 3 100 gms 15 minutes 4.00 4.00

TEST DATA SHEET : DCCT-04


Specific gravity
Sr.No. Description Flask 1 flask 2 Dummy Flask Limit
1 Wt. of cement taken for test in gm 64.00 64.00 -
2 Initial Level of liquid (Kerosene) in flask in ml 0.70 0.80 0
3 Final Level of liquid (Kerosene) in flask in ml 21.10 21.20 0
4 Increase in level of Dummy Flask due to temp 0.00 0.00
0
3.10 to 3.15
5 Correct volume of liquid after appling temp. 20.40 20.40
correction -
6 Specific Gravity 3.14 3.14 -
7 Av.Specific Gravity 3.14 -

Reference : Fineness-As per I.S 4031-1996 CL.8


Specific Gravity-As per I.S 4031-1992 CL.13
Tested by : S.G. Kokate (L.A.)
Checked by : Y.R. Chaudhari (R.A.) Assist.Reaserch Officer,
Vigilance
Equipment used : Std. Lechatelier Flask and 90 micron I.S.Sieve. & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCCT-05
Cement Tests
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmed

TYPE OF SAMPLE Ultatech 53 Grade


DATE OF RECEIPT OF SAMPLE 2/16/2019
DATE OF TESTING 16/02/2019 to 25/02/2019

Soundness of cement
Sr. No. Wt. of cement taken for test in Requirement of water V Actual water requirement in CC Distance separating the indicater point in
gm =0.78 x P = (V X 200) mm Limits as per IS Ref.
P=Std. consistancy 100 Initial Final Diff.
22 27 5
0.78× 30.75 23.985 × 200 26 32 6 Expansion Not More Than
1 200 gms
= 23.985 = 47.97 23 27 4 10 mm

Say 48 CC Average 5

TEST DATA SHEET : DCCT-06


Compressive Strength Test

Nornal Curing period Comp Comp Av.Comp Requirement


Wt. of Cement Wt. of Standard sand Wt. of water to be added
Sr. No Consistency Date of casting Date Of testing of Mortor Strength load Strength In Strength In as per IS in
in gms in gms in CC = (P/4+3)8
(P)% cubes In kN N/mm² N/mm² N/mm²

1 2 3 4 5 6 7 8 9 10 11 12
1 30.75 200 gms 600 gms 85.5 2/18/2019 2/21/2019 3 142 28.40
2 30.75 200 gms 600 gms 85.5 2/18/2019 2/21/2019 3 140 28.00 28.00 27
3 30.75 200 gms 600 gms 85.5 2/18/2019 2/21/2019 3 138 27.60
4 30.75 200 gms 600 gms 85.5 2/18/2019 2/25/2019 7 190 38.00
5 30.75 200 gms 600 gms 85.5 2/18/2019 2/25/2019 7 190 38.00 38.13 37
6 30.75 200 gms 600 gms 85.5 2/18/2019 2/25/2019 7 192 38.40

Reference : Soundness-As per I.S 4031-1996 CL.5


Comp. strength-As per I.S 4031-2000 CL.8
Tested by : S.G. Kokate (L.A.)
Checked by : Y.R. Chaudhari (R.A.) Assist.Reaserch Officer,
Vigilance
Equipment used : Chatelier Test apparatus and CTM Machine. & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR
8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 1/17/2019
DATE OF TESTING 17/01/2019 TO 18/01/2019
WT. OF SAMPLE 19020.00 gm

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained %age Commulative %age of Specified limit


Designation in gm. Retained %age Retained passing (%age)
No.

1 80 mm 525 2.76 2.76 97.24 > 95

2 25 mm 18264 96.03 98.79 1.21 <2

3 Pan 231 1.21 100.00 0.00

Total 19020 100.00

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,
CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.Sub Division Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100
tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Hard Murum / Soft Murum.
DATE OF SAMPLE 1/17/2019
DATE OF TESTING 17/01/2019 TO 18/01/2019
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide
Source and
Sample. comendium
other details I.S Natural Optimum
Plastic Plasticity for const. Of
No.
of sample Liquid Max Dry C.B.R. C.B.R.
bond CI.No. sieve Determined Specified moisture moisture
limit limit Index Density soaked Unsocked
(13.1) size content content

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Not more 80mm 97.24 > 95


Non -- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm 1.21 <2

TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y.R. Chaudhari (R.A.)
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
R.101 @ Km 1/100

Remark

15

er,

y Control(P.W.),
Ahemadnagar .
VIGILANCE & QUALITY CONTROL CIRCLE NASIK
DIST. LABORATORY, AHMEDNAGAR

TEST DATA SHEET : DCE -03 REVISION'O' PAGE 1 OF 1


CEMNT TEST
Job No. AHA/22-23 / 926 / PW/ANR
Name of Division Public Work Divi. Ahmednagar
Name of Sub-Division P.W.SubDivision Parner
Name of Work S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8
Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
Date of Testing 15/10/2018 to 26/10/2018
Details of Sample J.K. Super PPC Cement
TEST DATA SHEET : DCCT-01
Consistency
Wt. of cement Vol. of water Percentage of
Trial Reading on Vicat app. In
taken for test in added to dry water added Consistancy Remark
No. (mm)
gm cement in cc in dry cement
2 400 126 31.5 9 Hence Consistancy is
3 400 120 30.0 5
30.25
4 400 121 30.3 6

TEST DATA SHEET : DCCT-02


Setting Time
Requirement of Actual water A B C Limits as per IS Ref.
water Requirement
Final Initial Final Initial
0.85 ×P=V Time for
Sr. Wt. of cement in Initial Setting Setting Setting Setting Setting
P=Std. V×400 adding water
No. gms 100 Time Hr. Time Time Time Time
Consistency in cement Hr.
Min. (B-A) Hr. Min (Min) (Min.) (Min)
Min.
(C-A)
1 2 3 4 5 6 7 8

× 400/
0.85× 30.3 25.71 1:10 7:00 30
100
1 400 gms 10:30 11:40 17:30
=
25.71 = 102.85 70 min 400 min Minimum

TEST DATA SHEET : DCCT-03


Fineness by Sieving

Wt. of cement on 90
Wt. of cement Residue in
Sr. Time of Sieving mic. Sieve retained
Trial No. before sieving % observed Average % Residue Specified
No. in Min. after sieving in gm.
in gm(W1) = 5/3×100
(W2)

1 2 3 4 5 6 7 8
1 1 100 gms 15 minutes 5.00 5.00
5% Max for PPC
2 2 100 gms 15 minutes 4.00 4.00 4.67
10% Max for OPC
3 3 100 gms 15 minutes 5.00 5.00

Reference : Consistency- Methods of Physical tests for hydraulic cement.As per I.S 4031-1997 CL.6
Setting Time- As per I.S 4031-1998 CL.7
Fineness-As per I.S 4031-1996 CL.8

Tested by : S.G. Kokate (L.A.) Assist.Reaserch Officer,


Checked by : Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Equipment used :Vicat apparatus and Vicat mould,I.S sieve. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
Cement Tests
Job No. AHA/22-23 / 926 / PW/ANR
Name of Division Public Work Divi. Ahmednagar
Name of Sub-Division P.W.SubDivision Parner
Name of Work S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon
road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
Date of Testing 15/10/2018 to 26/10/2018
Details of Sample J.K. Super PPC Cement

TEST DATA SHEET : DCCT-04


Specific gravity
Sr.No. Description Flask 1 flask 2 Dummy Flask Limit
1 Wt. of cement taken for test in gm 64.00 64.00 -
Initial Level of liquid (Kerosene) in flask in ml
2 0.00 0.00 0
Final Level of liquid (Kerosene) in flask in ml
3 20.50 20.50 0
Increase in level of Dummy Flask due to temp
4 0.00 0.00 0 3.10 to 3.15

Correct volume of liquid after appling temp.


5 correction 20.50 20.50 -

6 Specific Gravity 3.12 3.12 -


7 Av.Specific Gravity 3.12 -

TEST DATA SHEET : DCCT-05


Soundness of cement
Sr. Wt. of cement Requirement of water Actual water requirement in CC Distance separating the
No. taken for test in V =0.78 x P = (V X 200) indicater point in mm Limits as per IS Ref.
gm
P=Std. consistancy 100 Initial Final Diff.
12 14 2
0.78× 30.25 23.60 × 200 16 19 3 Expansion Not More
1 200 gms
= 23.60 = 47.19 17 20 3 Than 10 mm

Say 47 CC Average 2.666667

TEST DATA SHEET : DCCT-06


Compressive Strength Test
Wt. of water to Curing Comp
Wt. of Wt. of Comp Av.Comp
Sr. Normal be added in Date of Date Of period of Strength
Consiste Cement Standard sand Strength Strength In
No ncy (P)% CC = casting testing Mortor load In
in gms in gms In N/mm² N/mm²
(P/4+3)8 cubes kN
1 2 3 4 5 6 7 8 9 10 11
1 30.25 200 gms 600 gms 84.5 10/19/2018 10/22/2018 3 84 16.80
2 30.25 200 gms 600 gms 84.5 10/19/2018 10/22/2018 3 82 16.40 16.80
3 30.25 200 gms 600 gms 84.5 10/19/2018 10/22/2018 3 86 17.20
4 30.25 200 gms 600 gms 84.5 10/19/2018 10/26/2018 7 112 22.40
5 30.25 200 gms 600 gms 84.5 10/19/2018 10/26/2018 7 114 22.80 22.53
6 30.25 200 gms 600 gms 84.5 10/19/2018 10/26/2018 7 112 22.40

Reference : Specific Gravity-As per I.S 4031-1992 CL.13


Soundness-As per I.S 4031-1996 CL.5
Comp. strength-As per I.S 4031-2000 CL.8
Tested by : S.G. Kokate (L.A.) Assist.Reaserch Officer,
Checked by : Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Equipment used :Std. Lechatelier flasks,Chatelier Test apparatus and CTM Dist.Laboratory,Ahmednagar
Machine.
K

PAGE 1 OF 1

adppur to MDR 8

Remark

Limits as per IS Ref.


Final
Setting
Time
(Min.)

600

Maximum

Remarks

aserch Officer,
uality Control(P.W.),
tory,Ahmednagar
K

pur to MDR 8 Chapadgaon

Limit

3.10 to 3.15

Limits as per IS Ref.

Expansion Not More


Than 10 mm

Requireme
nt as per
IS in
N/mm²
12

16

22

aserch Officer,
uality Control(P.W.),
tory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR.;- DATE;-
NAME OF DIVISION Public Work Divi. Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8
Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar

TYPE OF SAMPLE J.K. Super PPC Cement


DATE OF RECEIPT OF SAMPLE 10/15/2018 DATE OF TESTING;- 15/10/2018 to 26/10/2018
TEST RESULT OF CEMENT
Results obtained
Sr. No. Type of test Specified Limits
Sample-1
1 Fineness (%) 4.67 10% for OPC 5% for PPC
2 Setting Time(Min)
Initial 70 min Not less than 30 minutes.
Final 400 min Not More than 600 minutes.
3 Compresive Strength in N/sqmm Curing Period 33 Grade 43 Grade 53Grade
For 3Days 16.80 For 3 Days 16 N/mm² 23 N/mm² 27 N/mm²
For 7Days 22.53 For 7 Days 22 N/mm² 33 N/mm² 37 N/mm²
For 28Days ……… For 28 Days 33 N/mm² 43 N/mm² 53 N/mm²
Soundness by Le-Chateliar Apparatus
4 3 Expansion not more than 10 mm
mm
5 Specific Gravity 3.12 3.10 to 3.15
6 Std. Consistancy 30.8 Not Specified

Note : The test results are based on smaples received in Laboratory.

Reference : IS 4031 Part (I)1996 , IS 4031 Part (V)1998, IS 4031(VI)1992.


Tested by : S.G. Kokate (L.A.)
Checked by: Y.R.Chaudhari (R.A.) Assist.Reaserch Officer,

Equipment used : Vicat Apparatus, Lechatelier Apparatus, CTM Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 8.435 190 8.44

2 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 8.442 210 9.33 8.89 8.02

3 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 8.441 200 8.89

4 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 8.453 260 11.56

5 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 8.458 250 11.11 11.11 10.65

6 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 8.448 240 10.67

Reference I.S. 516-1999 CL.5.5. D.J.Officer,


Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes


Above 700
Cross Average Reqd.
Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 8.462 250 11.11

2 A-2 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 8.459 240 10.67 10.81 10.01

3 A-3 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 8.457 240 10.67

Reference I.S. 516-1999 CL.5.5.


D.J. Shewale
Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.441 260 11.56

2 D-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.452 530 23.56 19.85 23.10

3 D-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.458 550 24.44

4 E-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.462 550 24.44

5 E-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.454 540 24.00 24.30 23.10

6 E-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 8.459 550 24.44

Reference I.S. 516-1999 CL.5.5. D.J. Shewale


Assist.Reaserch Officer,
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 F-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.447 540 24.00

2 F-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.457 530 23.56 24.00 23.15

3 F-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.442 550 24.44

4 G-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.462 550 24.44

5 G-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.459 540 24.00 24.30 23.15

6 G-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 8.459 550 24.44

Reference I.S. 516-1999 CL.5.5.


D.J. Shewale
S.G. Kokate( L.A) Assist.Reaserch Officer,
TESTED BY
Vigilance & Quality
CHECKED BY S.V. Potdar (Sect.Engr.) Control(P.W.),
Dist.Laboratory,Ahmednagar
Assist.Reaserch Officer,
Vigilance & Quality
Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 H-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 660 29.33

2 H-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 790 35.11 32.15 30.00 i

3 H-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 720 32.00

4 I-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 690 30.67

5 I-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 750 33.33 31.85 30.00 j

6 I-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 710 31.56

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 710 31.56

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 690 30.67 32.59 30.00 k

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 800 35.56

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 680 30.22

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 710 31.56 32.30 30.00 l

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 790 35.11

Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
Control(P.W.),
Dist.Laboratory,Ahmednagar
Assist.Reaserch Officer,
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 225 10.00

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 225 10.00 10.00 10.00 m

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 225 10.00

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 225 10.00

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 225 10.00 10.00 20.00 n

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 225 10.00

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 15.00 o

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 16.00 p

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


:- J.N.Meshram (R.A) Assist.Reaserch Officer,
TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 17.00 q

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 18.00 r

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09

Reference I.S. 516-1999 CL.5.5.


:- J.N.Meshram (R.A) Assist.Reaserch Officer,
TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.

:- J.N.Meshram (R.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar

VIGILANCE & QUALITY CONTROL CIRCLE NASHIK


DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressi Compressive
Sr. Identification Date of Dimension of sectional Weight of Compre. Comp.
Concrete Date of Testing Specimen in ve Load in Strenght Remarks
No. Mark casting Specimen in mm Area in cubes in kg Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DCC-21
CONCRETE CUBE TEST

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ah

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressi Compressive
Identification Concrete Date of Dimension of sectional Weight of Compre. Comp.
Sr.No. Date of Testing Specimen in ve Load in Strength Remarks
Mark mix casting Specimen in mm Area in cubes in kg Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 9 10 11 12 13 14

1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8426 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8475 352 15.64 15.97 23.10

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 8432 362 16.09

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8496 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8546 352 15.64 15.64 23.10

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 8463 362 16.09


Reference I.S. 516-1999 CL.5.5.

S.G. Kokate( L.A) Assist.Reaserch Officer,


TESTED BY
Vigilance & Quality
CHECKED BY S.V. Potdar (Sect.Engr.) Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
Karjat Dist- Ahmednagar
TYPE OF SAMPLE :- Con. Cubes
DATE OF REPT.OF SAMPLE 4/13/2018
Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 190 8.44

2 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 210 9.33 8.89 8.02

3 1:04:08 M-7.5 2/17/2018 4/13/2018 55 150x150x150 22500 200 8.89

4 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 260 11.56

5 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 250 11.11 11.11 10.65

6 1:03:06 M-10 2/19/2018 4/13/2018 53 150x150x150 22500 240 10.67

Reference I.S. 516-1999 CL.5.5. D.J. Officer,


Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 250 11.11

2 A-2 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 240 10.67 10.81 10.01

3 A-3 M-10 2/10/2018 3/12/2018 30 150x150x150 22500 240 10.67

Reference I.S. 516-1999 CL.5.5.


D.J. Officer,
Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-
CubesAhmednagar

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 D-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 260 11.56

2 D-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 530 23.56 19.85 23.10

3 D-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 550 24.44

4 E-1 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 550 24.44

5 E-2 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 540 24.00 24.30 23.10

6 E-3 M-20 7/15/2017 10/11/2017 88 150x150x150 22500 550 24.44

Reference I.S. 516-1999 CL.5.5.


D.J. Officer,
Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:- DATE:-
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 F-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 540 24.00

2 F-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 530 23.56 24.00 23.15

3 F-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 550 24.44

4 G-1 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 550 24.44

5 G-2 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 540 24.00 24.30 23.15

6 G-3 M-20 7/15/2017 10/12/2017 89 150x150x150 22500 550 24.44

Reference I.S. 516-1999 CL.5.5.


D.J. Officer,
Assist.Reaserch Shewale
TESTED BY S.G. Kokate( L.A)
CHECKED BY S.V. Potdar (Sect.Engr.) Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-
CubesAhmednagar

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 H-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 660 29.33

2 H-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 790 35.11 32.15 30.00 i

3 H-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 720 32.00

4 I-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 690 30.67

5 I-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 750 33.33 31.85 30.00 j

6 I-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 710 31.56


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 710 31.56

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 690 30.67 32.59 30.00 k

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 800 35.56

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 680 30.22

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 710 31.56 32.30 30.00 l

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 790 35.11


Reference I.S. 516-1999 CL.5.5.
Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-
CubesAhmednagar

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00 10.00 10.00 m

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 225 10.00


4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00 10.00 20.00 n

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 225 10.00

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 15.00 o
15.00 o

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 16.00 p

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-
CubesAhmednagar

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 17.00 q

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 18.00 r

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes


Cross Average Reqd.
Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 M-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 M-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 19.00 s

3 M-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 N-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 N-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 20.00 t

6 N-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-
CubesAhmednagar

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes
Cross Average Reqd.
Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 P-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 P-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 21.00 u

3 P-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 R-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 R-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 22.00 v

6 R-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 J-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 J-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.00 w

3 J-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 K-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 K-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 24.00 x

6 K-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUB DIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE Karjat
:- Con.Dist-
CubesAhmednagar

DATE OF REPT.OF SAMPLE 4/13/2018


Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Grade of Age of Compressiv Compressive
Sr. Identification Dimension of sectional Compre. Comp.
Concrete Date of casting Date of Testing Specimen in e Load in Strenght Remarks
No. Mark Specimen in mm Area in Strenght Strenght h
mix Days kN inN/sqmm
sqmm inN/sqmm in N/sqmm

1 2 3 4 5 6 7 8 10 11 12 13 14

1 A-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 A-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 25.00 y

3 A-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 B-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 B-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 26.00 z

6 B-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST RESULTS SHEET : RCC-09
RESULTS OF CEMENT CONCRETE CUBES
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division Ahmednagar
NAME OF SUBDIVISION Public Work Sub-Div. Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dis

TYPE OF SAMPLE :-Con. Cubes


DATE OF RECEIPT OF SAMPLE 4/13/2018

Test Results of Compressive Strength of C.C.Cubes

Cross Average Reqd.


Age of Compressiv Compressive
Identification Concrete Dimension of sectional Compre. Comp.
Sr.No. Date of casting Date of Testing Specimen in e Load in Strength Remarks
Mark mix Specimen in mm Area in Strenght Strength in
Days kN inN/sqmm
sqmm inN/sqmm N/sqmm
1 2 3 4 5 6 7 8 10 11 12 13 14
1 D-1 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 364 16.18

2 D-2 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 352 15.64 15.97 23.10 0

3 D-3 M-15 7/2/2013 7/30/2013 28 150x150x150 22500 362 16.09

4 E-1 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 342 15.20

5 E-2 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 352 15.64 15.64 23.10 0

6 E-3 M-15 6/25/2013 7/26/2013 31 150x150x150 22500 362 16.09

Reference I.S. 516-1999 CL.5.5.


Assist.Reaserch Officer,
TESTED BY :- J.N.Meshram (R.A)
CHECKED BY Vigilance & Quality Control(P.W.),
EQUIPMENT USED :- C.T.M.Machine. Dist.Laboratory,Ahmednagar
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR LAB./NO./ANR:-
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @
Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Gray Blakish Rubble.
DATE OF REC. OF SAMPLE 9/29/2018
DATE OF TESTING 29/09/2018 to 01/10/2018

TEST RESULTS OF BUILDING STONE/RUBBLE

% Water Absorption Apparent Compressive Strength (N/sqmm) Impact Value(%) Crushing Value(%)
Sourse &
Sr.No. Specific
Other Details
Gravity
Deter
Specified Determined Specified Determined Specified Specified Determined
mined
Vide Std.
Specification
Gray Blakish
1 Clause A 4.41 2.87 Vide IS 1597 Part-1 1967 40.00N/mm2 42.50 Max.30% -------- Max.30%
Rubble. 8.1Not more
than 5%

Note :-The test result based on samples received in the Laboratory


TESTED BY S.G. Kokate (L.A.)
CHECKED BY Y.R.Chaudhari (R.A.) Assist.Reaserch Officer,
Equipment used :- CTM Machine. Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
aon road, MDR.101 @

Remarks
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR
NAME OF DIVISION Public Work Division , Ahmednagar
NAME OF SUBDIVISION P.W.SubDivision Parner
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni
Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100 tal-
TYPE OF SAMPLE :-Rubble
Karjat Dist- Ahmednagar
DATE OF SAMPLE 9/29/2018
DATE OF TESTING 29/09/2018 to 01/10/2018

SPECIFIC GRAVITY & WATER ABSORPTION


(I.S. 2386 PART III 1963, REFFIRMED 1997)

Sr.No. Particular Trial-1 Trial-2


Weight of saturated dry aggregate in air
1 in gm(Passing through 20mm sieve & B 1162 1184
retained on 10mm sieve )
Quantity of water added in 1000ml jar
2 containing the test pieces C 611 605
Weight of Oven dry aggregate in gm
3 A 1112 1135

4 Apperant Sp. Gravity A/(1000-C) 2.86 2.87


5 Water Absorption (B-A)/A x 100 4.496 4.317
6 Average Sp. Gravity 2.87
7 Average Water Absorption 4.41

CRUSHING STRENGTH OF BUILDING STONE

Sr .No. Particular Trial-1 Trial-2

1 Identificaton Mark ………… …………

2 Size of specimen 100x100x100 100x100x100

3 C/S Area perpendicular to load sqmm 10000.00 10000.00

4 Crushing Load in (kN) 410.00 420.00

5 Crushing Strength (N/sqmm) 41.00 42.00

6 Average Crushing Strength (N/sqmm) 41.50

7 Specified As Per I.S. 40.00 N/MM2

TESTED BY S.G. Kokate (L.A.) Assist.Reaserch Officer,


CHECKED BY Y.R.Chaudhari (R.A.) Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahmednagar
VIGILANCE & QUALITY CONTROL CIRCLE NASHIK
DIST. LABORATORY, AHMEDNAGAR
TEST DATA SHEET : DSDD-25

JOB NO. AHA/22-23 / 926 / PW/ANR


NAME OF DIVISION Public Work Division , Ahemadnagar
NAME OF SUBDIVISION #REF! Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR
8 Chapadgaon road, MDR.101 @ Km 1/100 tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Hard Murum
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 28/12/2017 TO 29/12/2017
WT. OF SAMPLE 19020.00 gm

SIEVE ANALYSIS FOR HARD MURUM

Sr.No. I.S.Sieve Wt.Retained %age Commulative %age of Specified limit


Designation in gm. Retained %age Retained passing (%age)
No.

1 80 mm 525 2.76 2.76 97.24 > 95

2 25 mm 18264 96.03 98.79 1.21 <2

3 Pan 231 1.21 100.00 0.00

Total 19020 100.00

TEST DATA SHEET : DSDD-25

ATERBERG'S LIMIT TEST I.S.2720 (PART V)1985

Sr.No. PERTICULARS LIQUID LIMIT PLASTIC LIMIT


1
NO. OF BLOWS
2
DISH NO.
3
WEIGHT OF DISH+WET SOIL IN gm W1
Sample tends to slide on Sample could not be
4
WEIGHT OF DISH+DRY SOIL IN gm W2 surface of cup,even though rolled into thread of 3
the test is repeated.Hence mm diameter. Hence
5 Liquid Limit could not be Plastic Limit could not
WEIGHT OF WATER IN gm W3=W1-W2
obtained. be obtained.
6
WEIGHT OF DISH IN gm W4
7
WEIGHT OF DRY SOIL IN gm W5=W2-W4
8
MOISTURE CONTENT (W3/W5)X100
9 Av.P.L.
FROM GRAPH M.C.(L.L.) FOR 25 BLOWS

PLASTICITY INDEX = LIQUID LIMIT - PLASTIC LIMIT

Hence material is Non Plastic

Reference :- IS 2720 (PART V) 1985


TESTED BY #REF! Assist.Reaserch#REF!
Officer,
CHECKED BY #REF!
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
DIST. LABORATORY, AHMEDNAGAR
JOB NO. AHA/22-23 / 926 / PW/ANR #REF! DATE:-
NAME OF DIVISION Public Work Division , Ahemadnagar
NAME OF SUBDIVISION #REF! Karjat
NAME OF WORK S.R. to Bridge on SH-54 to Rashin Alsunde Nimbe Khatgaon Loni Masadppur to MDR 8 Chapadgaon road, MDR.101 @ Km 1/100
tal- Karjat Dist- Ahmednagar
TYPE OF SAMPLE Hard Murum / Soft Murum.
DATE OF SAMPLE 15/09/2022.
DATE OF TESTING 28/12/2017 TO 29/12/2017
TEST RESULT OF SOIL/MURUM
Sieve Analysis
Aterbeg's limit Specified limit ( % Passing ) Compaction test
vide Natura
Source and
Sample. comendium l Max
other details I.S Optimum
Plastic Plasticity for const. Of
No.
of sample Liquid moistu Dry C.B.R.
bond CI.No. sieve Determined Specified moisture C.B.R. soaked
limit limit Index re Den Unsocked
(13.1) size content
conten sity
t
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Not more 80mm 97.24 > 95


Non -- -- -- -- --
1 Hard Murum -- -- than 4% for
Plastic
H.M. 25mm 1.21 <2

TESTED BY #REF! #REF!


Assist.Reaserch Officer,
CHECKED BY #REF!
Vigilance & Quality Control(P.W.),
Dist.Laboratory,Ahemadnagar .
R.101 @ Km 1/100

Remark

15

Control(P.W.),
hemadnagar .

You might also like