You are on page 1of 3

ECR-E-4565 272

CORE IN DRUM
PV Elite 25 SP1 Licensee: FABTECH INTERNATIONAL LTD
FileName : SHUTDOWN Case REV 1-------------------------------
Vessel Design Summary: Step: 43 1:18pm Sep 12,2023

Vessel Design Summary:

ASME Code, Section VIII Division 1, 2021

Diameter Spec : 3180.000 mm ID


Vessel Design Length, Tangent to Tangent 8300.00 mm

Specified Datum Line Distance 50.00 mm

Internal Design Temperature 65 C


Internal Design Pressure 1.140 MPa

External Design Temperature 0 C

Maximum Allowable Working Pressure 1.14 MPa


Shop Test Pressure 1.254 MPa

Required Minimum Design Metal Temperature -48.0 C


Warmest Computed Minimum Design Metal Temperature -48.0 C

Wind Design Code Euro Code


Earthquake Design Code Eurocode 8 1998-1:2004

Materials of Construction:

Component | | | | |Normal | Impact |


Type | Material | Class | Thickness | UNS # | ized | Tested |
----------------------------------------------------------------------------------------------
Shell | SA-516 70 | ... | ... | K02700 | No | Yes |
Head | SA-240 304 | ... | ... | S30400 | No | No |
Head | SA-516 70 | ... | ... | K02700 | No | Yes |
Nozzle | SA-182 F304 | ... | <= 130 | S30400 | No | No |
Nozzle | SA-765 II | ... | ... | K03047 | No | Yes |
Nozzle | SA-350 LF2 | ... | ... | K03011 | No | Yes |
Nozzle Flg | SA-182 F304 | ... | <= 130 | S30400 | No | No |
Nozzle Flg | SA-350 LF2 | ... | ... | K03011 | No | Yes |
Hrz Bolting | | ... | ... | | No | No |
Saddles | SA-516 70 | ... | ... | K02700 | No | No |

'Normalized is determined based on the UCS-66 material curve selection and Figure UCS-66.
'Impact Tested is based on material selection and material data properties.

Element Pressures and MAWP (MPa & mm):

| Design | | | Total | Str. | In |


Element Description | Pressure | Ext. | Element | Corrosion | Flg. | Creep |
or Type | + Stat. head | Press. | M.A.W.P | Allowance | Gov. | Range |
--------------------------------------------------------------------------------------------
LEFT HEAD | 1.140 | 0.00 | 1.160 | 0.0000 | No | No |
MAIN SHELL | 1.140 | 0.00 | 1.420 | 1.5000 | N/A | No |
RIGHT HEAD | 1.140 | 0.00 | 1.260 | 1.5000 | No | No |

Element Types and Properties:

Element |"To" Elev | Element | Nominal | Finished | Reqd Thk | Reqd Thk | Long | Circ |
| | Length |Thickness |Thickness | Internal | External | Eff | Eff |
Type | mm | mm | mm | mm | mm | mm | | |
------------------------------------------------------------------------------------------------
Ellipse | 0.0 | 50.0 | 16.0 | 13.4 | 13.1 | ... | 1.00 | 1.00 |
Cylinder | 8200.0 | 8200.0 | 18.0 | 18.0 | 14.7 | ... | 1.00 | 1.00 |
ECR-E-4565 273
CORE IN DRUM
PV Elite 25 SP1 Licensee: FABTECH INTERNATIONAL LTD
FileName : SHUTDOWN Case REV 1-------------------------------
Vessel Design Summary: Step: 43 1:18pm Sep 12,2023

Ellipse | 8250.0 | 50.0 | 20.0 | 16.0 | 14.6 | ... | 1.00 | 1.00 |

Saddle Parameters:
Saddle Width 230.000 mm
Saddle Bearing Angle 120.000 deg.
Centerline Dimension 2025.000 mm
Wear Pad Width 250.000 mm
Wear Pad Thickness 18.000 mm
Wear Pad Bearing Angle 135.000 deg.
Distance from Saddle to Tangent 900.000 mm

Baseplate Length 2950.000 mm


Baseplate Thickness 20.000 mm
Baseplate Width 250.000 mm
Number of Ribs (including outside ribs) 4
Rib Thickness 18.000 mm
Web Thickness 18.000 mm
Height of Center Web 415.000 mm
Number of Bolts in Baseplate 4

Baseplate Sketch

|------------------- 2950.000 mm --------------------|


------------------------------------------------------ ---
| |
| | 250.000 mm
| |
------------------------------------------------------ ---
Baseplate Plan View

------------------------------------------------------ ---
| | 20.000 mm
------------------------------------------------------ ---
Baseplate Side View

Summary of Maximum Saddle Loads, Operating Case, Un-Factored:


Maximum Vertical Saddle Load 338270.41 N
Maximum Transverse Saddle Shear Load 58538.61 N
Maximum Longitudinal Saddle Shear Load 101414.44 N

The Wind and Seismic loads were not load factored in this analysis.

Summary of Maximum Saddle Loads, Pressure Test Case:


Maximum Vertical Saddle Load 224536.92 N
Maximum Transverse Saddle Shear Load 7592.68 N
Maximum Longitudinal Saddle Shear Load 5221.50 N

Local Stress Analysis Results:

| Analysis | Max Stress | High Stress | Pass |


Description | Type | Ratio | Location | Fail |
------------------------------------------------------------------------------------
N5_20" | WRC-107/537 | 0.882 | n/a | Passed |
N6_14" | WRC-107/537 | 0.882 | n/a | Passed |
N1_16" | WRC-297 | 0.978 | Shell | Passed |
N2_16" | WRC-297 | 0.978 | Shell | Passed |
N3_16" | WRC-297 | 0.978 | Shell | Passed |
N4_16" | WRC-297 | 0.978 | Shell | Passed |
N7_16" | WRC-297 | 0.978 | Shell | Passed |
N8_6" | WRC-297 | 0.797 | Shell | Passed |
ECR-E-4565 274
CORE IN DRUM
PV Elite 25 SP1 Licensee: FABTECH INTERNATIONAL LTD
FileName : SHUTDOWN Case REV 1-------------------------------
Vessel Design Summary: Step: 43 1:18pm Sep 12,2023

Weights:
Fabricated - Bare W/O Removable Internals 41150.2 kg
Shop Test - Fabricated + Water ( Full ) 41150.2 kg
Shipping - Fab. + Rem. Intls.+ Shipping App. 41768.4 kg
Erected - Fab. + Rem. Intls.+ Insul. (etc) 41768.4 kg
Empty - Fab. + Intls. + Details + Wghts. 41768.4 kg
Operating - Empty + Operating Liquid (No CA) 41768.4 kg
Field Test - Empty Weight + Water (Full) 41768.4 kg

PV Elite is a trademark of Hexagon AB, 2023, All rights reserved.