1. Introduction
This new tool shall enlarge the operating window for offshore lifts. Sensors measure the actual
velocity of the boom tip, from this information the maximum SWL (Save Working Load) is computed.

The boom tip velocity is recorded and saved to a file with the extension .smp via the crane controller.
This file can be accessed via SCULI/Lift, and finally evaluated with the CMMS software. A more
detailed description follows below.

2. Get Data via SCULI/Lift


After the measurement is completed, for instructions see the crane manual, the post processing can
begin. To get the measurement connect the laptop to the Ethernet plug-in at the crane’s cabin and
then double click the following icon to open SCULI/Lift (placed on the desktop). Note: the dongle
needs to be plugged-in at the laptop’s USB port.

As soon as SCULI/Lift has opened, select CF2, as indicated via red circle (1), in the figure below.

(1)

(2)

Now switch to the folder named “MOTION” within CF2, mark the desired file with the nomenclature
“prefixDateTime.smp”, e.g. “S2011-03-27T144105.smp” and copy it (by clicking the green button
with a white arrow - (2) ) to the right to a directory of your choice. E.g. C:\\workdir\Measurement
Data.

Version Datum/Date Beschreibung / description Ersteller / Originator


1 27.04.2011 Manual Eberharter

Dieses Dokument darf ohne unsere Genehmigung weder kopiert, noch vervielfältigt werden.
This document shall not be copied or transferred to others without our consent. LWN_TechnicalDescription_9999_V001
1/3
Abt./Nr. / Dept./No.
Agenda/Protokoll, MOM TBE-S
3. The CMMS Software – a GUI
To get a post-analysis of the previous measured data start the CMMS software (placed on the
desktop).

A disclaimer appears!

In order to proceed with this software one needs to accept this disclaimer.

A List of the displayed data:


- Max. SWL: maximal allowed safe working load for the actual position and vessel motion regarding a
max. trim /heel of +/- 1° and fixed installation [t]
- Outreach: Radius of the main hoist [m]
- SG Angle: Slewing gear angle of the crane [°]
- Mean Vertical Boom Tip Velocity: histogram of the upper third [m/s]
- Max. Off Lead: maximal allowed off lead [°]
- Max. Side Lead: maximal allowed side lead [°]
- Max. Wind Speed: maximal allowed wind speed [m/s]
- Mean [m/s^2]: histogram of the upper third of the accelerations in x, y, z direction [m/s 2]
- Max. [m/s^2]: maximal measured and filtered accelerations in x, y, z directions [m/s 2]

2/3
Abt./Nr. / Dept./No.
Agenda/Protokoll, MOM TBE-S
First click the “Load File” button and select the desired file, see red circle in the next figure below (The
default directory is: C:\\workdir\Measurement Data ).

After the file was loaded successfully, computation can be started by clicking the “Compute SWL” button.
The computed and proposed results are then displayed, as shown in the figure below.