You are on page 1of 26

Tuong5m

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: REINFORCED CONCRETE WALL ON RING ROAD No3

b1 a b2

G/L

f
b

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2500 kg/m3 ® gc = 24.5 kN/m3
• Unit Weight of Soil = 1800 kg/m3 ® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.00

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 5.000 Horizontal Dimension b1 0.600
Footing Width b 3.200 Horizontal Dimension b2 2.000
Bottom Stem Width a 0.600 Horizontal Dimension L 1.000
Top Stem Width n 0.300 Soil cover thickness c -
Footing Depth d 0.600
Footing Slope f -

FOOTING DESIGN

Loading Data:
Ht = 5.600 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.000
KAE = 0.333 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 5.60m heq= 0.17 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 1
Tuong5m

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

+M
S1
b
+H

S3

+V
Sign
Convention

a a1
c

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.36 1.000 9 0.300 1.300 11
Section A1 0.36 1.000 9 0.900 0.700 6
VERTICAL LOADS

Section B 2.25 1.000 55 0.900 0.700 39


Section C 1.20 1.000 29 2.200 -0.600 -18
Curb+handrailing 1.000 - 0.750 0.850 -
Concrete Total - - 102 - - 39
Soil weight
Section S1 10.00 1.000 176 2.200 -0.600 -106
Section S2 0.75 1.000 13 1.100 0.500 7
Section S3 - 1.000 - 0.300 1.300 -
Soil Total - - 190 - - -99
LL Surcharge 5.89 1.000 6 2.200 -0.600 -4
Active 92.20 1.000 92 - 1.867 172
Passive - 1.000 - 0.200 -
HORIZONTAL LOADS

LL Surcharge 5.50 1.000 5 - 2.800 15


PH1-EQ = 92.20 1.000 92 - 1.680 155
EQ from Retaining wall
Section A 0.36 1.000 - - 0.300 -
Section A1 0.36 1.000 - - 0.300 -
Section B 2.25 1.000 - - 3.100 -
Section C 1.20 1.000 - - 0.300 -
Curb+handrailing - 1.000 - 5.600 -
Abutment Total - - - - - -
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING AT FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 102 - 39
Earth on footing (EV) g bE 190 - -99
Earth Pressures (EH) g bE - 92 172
Live Load Surcharge (LS) g bL 6 5 12
Earth Pressure at seismic (EQ1) g bE - 92 155
Earthquake Forces (EQ2) g bEQ - - -

Page 2
Tuong5m

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

LOAD FACTORS
LOADS COMBINATIONS
I II III
Dead Load (DC) 1.10 0.90 0.00
Earth on footing (EV) 1.20 0.90 0.00
Earth Pressures (EH) 1.20 0.90 0.00
Live Load Surcharge (LS) 1.40 1.12 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00
Earthquake Forces (EQ2) 0.00 0.00 0.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 348 118 147
II 269 89 114
III 0 0 0

SV

CONTACT PRESSURE
SM qmax qmin Contributio
SH
Group (kN/m2) (kN/m2) n length
I -194.652 -23 3.20
eV qmin
qmax II -151 -18 3.20
III - - -

SV
Contribution length

BEARING CAPACTITY OF FOUNDATION SOIL

Bearing resistance of soil 196.20 KN/m2

CONTACT PRESSURE
Bearing
qmax qmin Conclusion
resistance
Group (kN/m2) (kN/m2)
I ### -23 196.20 OK
II -151 -18 196.20 OK
III - - 196.20 OK

CHECKING FAILURE BY OVERTURNING


Checking overturning conditions folows 11.6.3.3 article

CHECKING FAILURE BY OVERTURNING


SV SH SM ev ev/y<0.7
(kN) (kN) (kN•m)
348 118 147 0.42 OK
269 89 114 0.42 OK
0 0 0 - 0

Page 3
Tuong4m

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: REINFORCED CONCRETE WALL ON RING ROAD No3

b1 a b2

G/L

f
b

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2500 kg/m3 ® gc = 24.5 kN/m3
• Unit Weight of Soil = 1800 kg/m3 ® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.00

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 4.000 Horizontal Dimension b1 0.400
Footing Width b 2.500 Horizontal Dimension b2 1.500
Bottom Stem Width a 0.600 Horizontal Dimension L 1.000
Top Stem Width n 0.300 Soil cover thickness c -
Footing Depth d 0.600
Footing Slope f -

FOOTING DESIGN

Loading Data:
Ht = 4.600 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.000
KAE = 0.333 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 4.60m heq= 0.17 m 0
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 4
Tuong4m

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

+M
S1
b
+H

S3

+V
Sign
Convention

a a1
c

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.24 1.000 6 0.200 1.050 6
Section A1 0.36 1.000 9 0.700 0.550 5
VERTICAL LOADS

Section B 1.80 1.000 44 0.700 0.550 24


Section C 0.90 1.000 22 1.750 -0.500 -11
Curb+handrailing 1.000 - 0.550 0.700 -
Concrete Total - - 81 - - 24
Soil weight
Section S1 6.00 1.000 106 1.750 -0.500 -53
Section S2 0.60 1.000 11 0.900 0.350 4
Section S3 - 1.000 - 0.200 1.050 -
Soil Total - - 116 - - -49
LL Surcharge 4.42 1.000 4 1.750 -0.500 -2
Active 62.21 1.000 62 - 1.533 95
Passive - 1.000 - 0.200 -
HORIZONTAL LOADS

LL Surcharge 4.52 1.000 5 - 2.300 10


PH1-EQ = 62.21 1.000 62 - 1.380 86
EQ from Retaining wall
Section A 0.24 1.000 - - 0.300 -
Section A1 0.36 1.000 - - 0.300 -
Section B 1.80 1.000 - - 2.600 -
Section C 0.90 1.000 - - 0.300 -
Curb+handrailing - 1.000 - 4.600 -
Abutment Total - - - - - -
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING AT FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 81 - 24
Earth on footing (EV) g bE 116 - -49
Earth Pressures (EH) g bE - 62 95
Live Load Surcharge (LS) g bL 4 5 8
Earth Pressure at seismic (EQ1) g bE - 62 86
Earthquake Forces (EQ2) g bEQ - - -

Page 5
Tuong4m

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

LOAD FACTORS
LOADS COMBINATIONS
I II III
Dead Load (DC) 1.10 0.90 0.00
Earth on footing (EV) 1.20 0.90 0.00
Earth Pressures (EH) 1.20 0.90 0.00
Live Load Surcharge (LS) 1.40 1.12 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00
Earthquake Forces (EQ2) 0.00 0.00 0.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 235 81 94
II 182 61 73
III 0 0 0

SV

CONTACT PRESSURE
SM qmax qmin Contributio
SH
Group (kN/m2) (kN/m2) n length
I -183.731 -4 2.50
eV qmin
qmax II -143 -3 2.50
III - - -

SV
Contribution length

BEARING CAPACTITY OF FOUNDATION SOIL

Bearing resistance of soil 196.20 KN/m2

CONTACT PRESSURE
Bearing
qmax qmin Conclusion
resistance
Group (kN/m2) (kN/m2)
I ### -4 196.20 OK
II -143 -3 196.20 OK
III - - 196.20 OK

CHECKING FAILURE BY OVERTURNING


Checking overturning conditions folows 11.6.3.3 article

CHECKING FAILURE BY OVERTURNING


SV SH SM ev ev/y<0.7
(kN) (kN) (kN•m)
235 81 94 0.40 OK
182 61 73 0.40 OK
0 0 0 - 0

Page 6
Tuong5m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: REINFORCED CONCRETE WALL ON RING ROAD No3

b1 a b2

G/L

f
b

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2300 kg/m3 ® gc = 22.5 kN/m3
• Unit Weight of Soil = 1800 kg/m3 ® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.00

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 5.000 Horizontal Dimension b1 0.400
Footing Width b 3.350 Horizontal Dimension b2 0.550
Bottom Stem Width a 2.400 Horizontal Dimension L 1.000
Top Stem Width n 0.500 Soil cover thickness c 0.200
Footing Depth d 0.800
Footing Slope f 0.400

FOOTING DESIGN

Loading Data:
Ht = 5.800 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.000
KAE = 0.333 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 5.80m heq= 0.17 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 7
Tuong5m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

+M
S1
b
+H

S3

+V
Sign Convention

a a1
c

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.33 1.000 7 0.202 1.473 11
Section A1 2.38 1.000 54 1.600 0.075 4
VERTICAL LOADS

Section B 7.25 1.000 163 1.600 0.075 12


Section C 0.64 1.000 14 3.057 -1.382 -20
Curb+handrailing 1.000 - 0.650 1.025 -
Concrete Total - - 239 - - 7
Soil weight
Section S1 2.75 1.000 49 3.075 -1.400 -68
Section S2 4.75 1.000 84 2.167 -0.492 -41
Section S3 1.41 1.000 1 0.200 1.475 2
Soil Total - - 134 - - -107
LL Surcharge 1.62 1.000 2 3.075 -1.400 -2
Active 98.90 1.000 99 - 1.933 191
Passive - 1.000 - 0.467 -
HORIZONTAL LOADS

LL Surcharge 5.70 1.000 6 - 2.900 17


PH1-EQ = 98.90 1.000 99 - 1.740 172
EQ from Retaining wall
Section A 0.33 1.000 - - 0.347 -
Section A1 2.38 1.000 - - 0.600 -
Section B 7.25 1.000 - - 3.700 -
Section C 0.64 1.000 - - 0.347 -
Curb+handrailing - 1.000 - 5.800 -
Abutment Total - - - - - -
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING AT FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 239 - 7
Earth on footing (EV) g bE 134 - -107
Earth Pressures (EH) g bE - 99 191
Live Load Surcharge (LS) g bL 2 6 14
Earth Pressure at seismic (EQ1) g bE - 99 172
Earthquake Forces (EQ2) g bEQ - - -

Page 8
Tuong5m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

LOAD FACTORS
LOADS COMBINATIONS
I II III
Dead Load (DC) 1.10 0.90 0.00
Earth on footing (EV) 1.20 0.90 0.00
Earth Pressures (EH) 1.20 0.90 0.00
Live Load Surcharge (LS) 1.40 1.12 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00
Earthquake Forces (EQ2) 0.00 0.00 0.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 426 127 129
II 337 95 98
III 0 0 0

SV

CONTACT PRESSURE
SM qmax qmin Contributio
SH
Group (kN/m2) (kN/m2) n length
I -195.949 -58 3.35
eV qmin
qmax II -153 -48 3.35
III - - -

SV
Contribution length

BEARING CAPACTITY OF FOUNDATION SOIL

Bearing resistance of soil 196.20 KN/m2

CONTACT PRESSURE
Bearing
qmax qmin Conclusion
resistance
Group (kN/m2) (kN/m2)
I ### -58 196.20 OK
II -153 -48 196.20 OK
III - - 196.20 OK

CHECKING FAILURE BY OVERTURNING


Checking overturning conditions folows 11.6.3.3 article

CHECKING FAILURE BY OVERTURNING


SV SH SM ev ev/y<0.7
(kN) (kN) (kN•m)
426 127 129 0.30 OK
337 95 98 0.29 OK
0 0 0 - 0

Page 9
Tuong4m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: REINFORCED CONCRETE WALL ON RING ROAD No3

b1 a b2

G/L

f
b

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2300 kg/m3 ® gc = 22.5 kN/m3
• Unit Weight of Soil = 1800 kg/m3 ® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.00

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 4.000 Horizontal Dimension b1 0.400
Footing Width b 2.700 Horizontal Dimension b2 0.500
Bottom Stem Width a 1.800 Horizontal Dimension L 1.000
Top Stem Width n 0.500 Soil cover thickness c 0.200
Footing Depth d 0.800
Footing Slope f 0.400

FOOTING DESIGN

Loading Data:
Ht = 4.800 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.000
KAE = 0.333 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 4.80m heq= 0.17 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 10
Tuong4m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

+M
S1
b
+H

S3

+V
Sign Convention

a a1
c

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.33 1.000 7 0.202 1.148 9
Section A1 1.79 1.000 40 1.300 0.050 2
VERTICAL LOADS

Section B 4.60 1.000 104 1.300 0.050 5


Section C 0.58 1.000 13 2.433 -1.083 -14
Curb+handrailing 1.000 - 0.650 0.700 -
Concrete Total - - 165 - - 2
Soil weight
Section S1 2.00 1.000 35 2.450 -1.100 -39
Section S2 2.60 1.000 46 1.767 -0.417 -19
Section S3 1.41 1.000 1 0.200 1.150 2
Soil Total - - 83 - - -56
LL Surcharge 1.47 1.000 1 2.450 -1.100 -2
Active 67.74 1.000 68 - 1.600 108
Passive - 1.000 - 0.467 -
HORIZONTAL LOADS

LL Surcharge 4.71 1.000 5 - 2.400 11


PH1-EQ = 67.74 1.000 68 - 1.440 98
EQ from Retaining wall
Section A 0.33 1.000 - - 0.347 -
Section A1 1.79 1.000 - - 0.600 -
Section B 4.60 1.000 - - 3.200 -
Section C 0.58 1.000 - - 0.347 -
Curb+handrailing - 1.000 - 4.800 -
Abutment Total - - - - - -
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING AT FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 165 - 2
Earth on footing (EV) g bE 83 - -56
Earth Pressures (EH) g bE - 68 108
Live Load Surcharge (LS) g bL 1 5 10
Earth Pressure at seismic (EQ1) g bE - 68 98
Earthquake Forces (EQ2) g bEQ - - -

Page 11
Tuong4m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

LOAD FACTORS
LOADS COMBINATIONS
I II III
Dead Load (DC) 1.10 0.90 0.00
Earth on footing (EV) 1.20 0.90 0.00
Earth Pressures (EH) 1.20 0.90 0.00
Live Load Surcharge (LS) 1.40 1.12 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00
Earthquake Forces (EQ2) 0.00 0.00 0.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 282 88 78
II 224 66 59
III 0 0 0

SV

CONTACT PRESSURE
SM qmax qmin Contributio
SH
Group (kN/m2) (kN/m2) n length
I -168.534 -40 2.70
eV qmin
qmax II -132 -34 2.70
III - - -

SV
Contribution length

BEARING CAPACTITY OF FOUNDATION SOIL

Bearing resistance of soil 196.20 KN/m2

CONTACT PRESSURE
Bearing
qmax qmin Conclusion
resistance
Group (kN/m2) (kN/m2)
I ### -40 196.20 OK
II -132 -34 196.20 OK
III - - 196.20 OK

CHECKING FAILURE BY OVERTURNING


Checking overturning conditions folows 11.6.3.3 article

CHECKING FAILURE BY OVERTURNING


SV SH SM ev ev/y<0.7
(kN) (kN) (kN•m)
282 88 78 0.28 OK
224 66 59 0.26 OK
0 0 0 - 0

Page 12
Tuong3m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: REINFORCED CONCRETE WALL ON RING ROAD No3

b1 a b2

G/L

f
b

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2300 kg/m3 ® gc = 22.5 kN/m3
• Unit Weight of Soil = 1800 kg/m3 ® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.00

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 3.000 Horizontal Dimension b1 0.200
Footing Width b 1.800 Horizontal Dimension b2 0.300
Bottom Stem Width a 1.300 Horizontal Dimension L 1.000
Top Stem Width n 0.500 Soil cover thickness c 0.200
Footing Depth d 0.800
Footing Slope f 0.400

FOOTING DESIGN

Loading Data:
Ht = 3.800 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.000
KAE = 0.333 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 3.80m heq= 0.17 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 13
Tuong3m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

+M
S1
b
+H

S3

+V
Sign Convention

a a1
c

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.16 1.000 4 0.101 0.799 3
Section A1 1.29 1.000 29 0.850 0.050 1
VERTICAL LOADS

Section B 2.70 1.000 61 0.850 0.050 3


Section C 0.35 1.000 8 1.640 -0.740 -6
Curb+handrailing 1.000 - 0.450 0.450 -
Concrete Total - - 101 - - 2
Soil weight
Section S1 0.90 1.000 16 1.650 -0.750 -12
Section S2 1.20 1.000 21 1.233 -0.333 -7
Section S3 0.71 1.000 1 0.100 0.800 1
Soil Total - - 38 - - -18
LL Surcharge 0.88 1.000 1 1.650 -0.750 -1
Active 42.45 1.000 42 - 1.267 54
Passive - 1.000 - 0.467 -
HORIZONTAL LOADS

LL Surcharge 3.73 1.000 4 - 1.900 7


PH1-EQ = 42.45 1.000 42 - 1.140 48
EQ from Retaining wall
Section A 0.16 1.000 - - 0.347 -
Section A1 1.29 1.000 - - 0.600 -
Section B 2.70 1.000 - - 2.700 -
Section C 0.35 1.000 - - 0.347 -
Curb+handrailing - 1.000 - 3.800 -
Abutment Total - - - - - -
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING AT FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 101 - 2
Earth on footing (EV) g bE 38 - -18
Earth Pressures (EH) g bE - 42 54
Live Load Surcharge (LS) g bL 1 4 6
Earth Pressure at seismic (EQ1) g bE - 42 48
Earthquake Forces (EQ2) g bEQ - - -

Page 14
Tuong3m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

LOAD FACTORS
LOADS COMBINATIONS
I II III
Dead Load (DC) 1.10 0.90 0.00
Earth on footing (EV) 1.20 0.90 0.00
Earth Pressures (EH) 1.20 0.90 0.00
Live Load Surcharge (LS) 1.40 1.12 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00
Earthquake Forces (EQ2) 0.00 0.00 0.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 158 56 53
II 126 42 40
III 0 0 0

SV

CONTACT PRESSURE
SM qmax qmin Contributio
SH
Group (kN/m2) (kN/m2) n length
I -187.104 - 1.69
eV qmin
qmax II -145 - 1.74
III - - -

SV
Contribution length

BEARING CAPACTITY OF FOUNDATION SOIL

Bearing resistance of soil 196.20 KN/m2

CONTACT PRESSURE
Bearing
qmax qmin Conclusion
resistance
Group (kN/m2) (kN/m2)
I ### - 196.20 OK
II -145 - 196.20 OK
III - - 196.20 OK

CHECKING FAILURE BY OVERTURNING


Checking overturning conditions folows 11.6.3.3 article

CHECKING FAILURE BY OVERTURNING


SV SH SM ev ev/y<0.7
(kN) (kN) (kN•m)
158 56 53 0.34 OK
126 42 40 0.32 OK
0 0 0 - 0

Page 15
Tuong2m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: REINFORCED CONCRETE WALL ON RING ROAD No3

b1 a b2

G/L

f
b

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2300 kg/m3 ® gc = 22.5 kN/m3
• Unit Weight of Soil = 1800 kg/m3 ® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.00

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 2.000 Horizontal Dimension b1 0.200
Footing Width b 1.400 Horizontal Dimension b2 0.300
Bottom Stem Width a 0.900 Horizontal Dimension L 1.000
Top Stem Width n 0.400 Soil cover thickness c 0.200
Footing Depth d 0.800
Footing Slope f 0.400

FOOTING DESIGN

Loading Data:
Ht = 2.800 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.000
KAE = 0.333 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 2.80m heq= 0.17 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 16
Tuong2m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

+M
S1
b
+H

S3

+V
Sign Convention

a a1
c

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.17 1.000 4 0.101 0.599 2
Section A1 0.89 1.000 20 0.650 0.050 1
VERTICAL LOADS

Section B 1.30 1.000 29 0.650 0.050 1


Section C 0.35 1.000 8 1.240 -0.540 -4
Curb+handrailing 1.000 - 0.400 0.300 -
Concrete Total - - 61 - - 0
Soil weight
Section S1 0.60 1.000 11 1.250 -0.550 -6
Section S2 0.50 1.000 9 0.933 -0.233 -2
Section S3 0.71 1.000 1 0.100 0.600 0
Soil Total - - 20 - - -7
LL Surcharge 0.88 1.000 1 1.250 -0.550 -0
Active 23.05 1.000 23 - 0.933 22
Passive - 1.000 - 0.467 -
HORIZONTAL LOADS

LL Surcharge 2.75 1.000 3 - 1.400 4


PH1-EQ = 23.05 1.000 23 - 0.840 19
EQ from Retaining wall
Section A 0.17 1.000 - - 0.347 -
Section A1 0.89 1.000 - - 0.600 -
Section B 1.30 1.000 - - 2.200 -
Section C 0.35 1.000 - - 0.347 -
Curb+handrailing - 1.000 - 2.800 -
Abutment Total - - - - - -
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING AT FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 61 - 0
Earth on footing (EV) g bE 20 - -7
Earth Pressures (EH) g bE - 23 22
Live Load Surcharge (LS) g bL 1 3 3
Earth Pressure at seismic (EQ1) g bE - 23 19
Earthquake Forces (EQ2) g bEQ - - -

Page 17
Tuong2m (DX)

MAI DICH-PHAP VAN PROJECT Date Doc. No.


15-Dec-23

REINFORCED CONCRETE WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

LOAD FACTORS
LOADS COMBINATIONS
I II III
Dead Load (DC) 1.10 0.90 0.00
Earth on footing (EV) 1.20 0.90 0.00
Earth Pressures (EH) 1.20 0.90 0.00
Live Load Surcharge (LS) 1.40 1.12 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00
Earthquake Forces (EQ2) 0.00 0.00 0.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 92 32 22
II 74 24 17
III 0 0 0

SV

CONTACT PRESSURE
SM qmax qmin Contributio
SH
Group (kN/m2) (kN/m2) n length
I -133.617 - 1.38
eV qmin
qmax II -104 -1 1.40
III - - -

SV
Contribution length

BEARING CAPACTITY OF FOUNDATION SOIL

Bearing resistance of soil 196.20 KN/m2

CONTACT PRESSURE
Bearing
qmax qmin Conclusion
resistance
Group (kN/m2) (kN/m2)
I ### - 196.20 OK
II -104 -1 196.20 OK
III - - 196.20 OK

CHECKING FAILURE BY OVERTURNING


Checking overturning conditions folows 11.6.3.3 article

CHECKING FAILURE BY OVERTURNING


SV SH SM ev ev/y<0.7
(kN) (kN) (kN•m)
92 32 22 0.24 OK
74 24 17 0.23 OK
0 0 0 - 0

Page 18
TUONG CHAN

Date Doc. No.


15-Dec-23

SEGMENT 1 - CONCRETE RETAINING WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

Designed by:
Wall Name: SEGMENT 1 - CONCRETE RETAINING WALL ON RING ROAD No3

b1 a b2

G/L

MATERIAL UNIT WEIGHTS


• Unit Weight of Concrete = 2500 kg/m3 ® gc = 24.5 kN/m3
• Unit Weight of Soil = 1800 kg/m 3
® gs = 17.6 kN/m3
• Internal Friction Angle of Backfill fb = 30.0 º
• Foundation condition (0 - on soil; 1 - on rock) = 0
• Earthquake Coefficient AQ = 0.17

RETAINING WALL DIMENSIONS (IN METRES)


Item Symbol Value Item Symbol Value
Height h 5.000 Horizontal Dimension b1 0.500
Footing Width b 2.500 Horizontal Dimension b2 1.500
Bottom Stem Width a 0.500 Horizontal Dimension L 15.000
Top Stem Width n 0.300 Soil cover thickness c 0.200
Footing Depth d 0.600
Footing Slope f -

FOUNDATION DESIGN

Loading Data:
Ht = 5.600 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.168
KAE = 0.449 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 5.60m heq= 0.00 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

Page 19
TUONG CHAN

Date Doc. No.


15-Dec-23

SEGMENT 1 - CONCRETE RETAINING WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION

S2

h
+M S1
+H
b1 a b2

G/L b
+V
Sign
Convention c S3

d c
a a1

1-1 2-2
b

RETAINING WALL LOADS


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.30 15.000 110 0.250 1.000 110
Section A1 0.30 15.000 110 0.750 0.500 55
VERTICAL LOADS

Section B 2.00 15.000 735 0.750 0.500 368


Section C 0.90 15.000 331 1.750 -0.500 -165
Curb+handrailing 15.000 - 0.650 0.600 -
Concrete Total - - 1286 - - 368
Soil weight
Section S1 7.50 15.000 1985 1.750 -0.500 -992
Section S2 0.50 15.000 132 0.933 0.317 42
Section S3 0.10 15.000 26 0.250 1.000 26
Soil Total - - 2143 - - -924
LL Surcharge - 15.000 - 1.750 -0.500 -
Active 92.20 15.000 1383 - 1.867 2582
Passive - 15.000 - 0.267 -
HORIZONTAL LOADS

LL Surcharge - 15.000 - - 2.800 -


PH1-EQ = 124.07 15.000 1861 - 1.680 3127
EQ from Retaining wall
Section A 0.30 15.000 19 - 0.300 6
Section A1 0.30 15.000 19 - 0.300 6
Section B 2.00 15.000 125 - 3.100 387
Section C 0.90 15.000 56 - 0.300 17
Curb+handrailing - 15.000 - 5.600 -
Abutment Total - - 219 - - 415
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING TO BOTTOM OF FOOTING CENTER


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 1286 - 368
Earth on footing (EV) g bE 2143 - -924
Earth Pressures (EH) g bE - 1383 2582
Live Load Surcharge (LS) g bL - - -
Earth Pressure at seismic (EQ1) g bE - 1861 3127

Page 20
TUONG CHAN

Date Doc. No.


15-Dec-23

SEGMENT 1 - CONCRETE RETAINING WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION
Earthquake Forces (EQ2) g bEQ - 219 415

Combination 1 (Strenght - I -1) 1.25DC+1.5EH+1.35EV+ 1.75 LS


Combination 2 (Strenght - I -2) 0.9DC+1EV+0.9EH+ 1.75 LS
Combination 3 (Extreme event -IA) 1.25DC+1.35EV+ 0.50LS + 1.00EQ
Combination 4 (Extreme event -IB) 0.9DC+1EV+ 0.50LS + 1.00EQ

LOAD FACTORS
LOADS COMBINATIONS
I II III IV
Dead Load (DC) 1.10 0.00 0.00 0.90
Earth on footing (EV) 1.20 0.00 0.00 1.00
Earth Pressures (EH) 1.20 0.00 0.00 0.00
Live Load Surcharge (LS) 0.00 0.00 0.00 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00 1.00
Earthquake Forces (EQ2) 0.00 0.00 0.00 1.00

Load to bottom of footing


SV SH SM
Comb (kN) (kN) (kN•m)
I 3987 1660 2393
II 0 0 0
III 0 0 0
VI 3301 2080 2949

STEM DESIGN

Loading Data:
Ht = 5.000 m
KA = 0.333
Kp = 0.000 (ignore)
q = 0.168
KAE = 0.449 rad
Equivalent height of soil for highway loading taken from Table 3.11.6.2.1
H= 0.0m heq= 0m
H= 0.0m heq= 0m
H= 5.00m heq1= 0.00 m
(Linear interpolation )
Load of curb+handrailing 0.0 KN/m

RETAINING WALL LOADS TO BOTTOM OF STEM


Area Length Force X1 Arm Moment
Description (m )
2
(m) (kN) (m) (m) (kN•m)
Selfweight
Section B 2.00 15.000 735 0.750 -0.125 -92
VERTICAL

Curb+handrailing 15.000 - 0.650 0.100 -


LOADS

Concrete Total - - 735 - - -92


Soil weight
Section S2 0.50 15.000 132 0.933 -0.183 -24
Soil Total - - 132 - - -24
Active 73.50 15.000 1103 - 1.667 1838
Passive - 15.000 - 0.067 -
HORIZONTAL

LL Surcharge - 15.000 - - 2.500 -


LOADS

PH1-EQ = 98.91 15.000 1484 - 1.500 2225


EQ from Retaining wall
Section B 2.00 15.000 125 - 2.500 312
Curb+handrailing - 15.000 - 5.000 -
Abutment Total - - 125 - - 312
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING TO BOTTOM OF STEM


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 735 - -92
Earth on footing (EV) g bE 132 - -24
Earth Pressures (EH) g bE - 1103 1838
Live Load Surcharge (LS) g bL - - -

Page 21
TUONG CHAN

Date Doc. No.


15-Dec-23

SEGMENT 1 - CONCRETE RETAINING WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION
Earth Pressure at seismic (EQ1) g bE - 1484 2225
Earthquake Forces (EQ2) g bEQ - 125 312

Combination 1 (Strenght - I -1) 1.25DC+1.5EH+1.35EV+ 1.75 LS


Combination 2 (Strenght - I -2) 0.9DC+1EV+0.9EH+ 1.75 LS
Combination 3 (Extreme event -IA) 1.25DC+1.35EV+ 0.50LS + 1.00EQ
Combination 4 (Extreme event -IB) 0.9DC+1EV+ 0.50LS + 1.00EQ

LOAD FACTORS
LOADS COMBINATIONS
I II III IV
Dead Load (DC) 1.10 0.00 0.00 0.90
Earth on footing (EV) 1.20 0.00 0.00 1.00
Earth Pressures (EH) 1.20 0.00 0.00 0.00
Live Load Surcharge (LS) 0.00 0.00 0.00 0.00
Earth Pressure at seismic (EQ1) 0.00 0.00 0.00 1.00
Earthquake Forces (EQ2) 0.00 0.00 0.00 1.00

Load to bottom of stem


SV SH SM
Comb (kN) (kN) (kN•m)
I 967 1323 2075
II 0 0 0
III 0 0 0
VI 794 1609 2431

FOOTING DESIGN

RETAINING WALL LOADS TO SECTION 1-1


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section A 0.30 15.000 110 0.250 0.250 28
VERTICAL LOADS

Concrete Total - - 110 - - 28


Soil weight
Section S3 0.10 15.000 26 0.250 0.250 7
Soil Total - - 26 - - 7
Piles reaction
Longitudinal force -1280 0.500 -640
Momen -317
Reaction Total - - -1280 - - -957
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING TO SECTION 1-1


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 110 - 28
Earth on footing (EV) g bE 26 - 7
Reaction (RV) g bR -1280 -957

Combination 1 (Strenght - I -1) 1.25DC+1.35EV+1RV


Combination 2 (Strenght - I -2) 0.9DC+1EV+1RV
Combination 3 (Extreme event -IA) 1.25DC+1.35EV+1RV
Combination 4 (Extreme event -IB) 0.9DC+1EV+1RV

LOAD FACTORS
LOADS COMBINATIONS
I II III IV
Dead Load (DC) 1.25 0.90 1.25 0.90
Earth on footing (EV) 1.35 1.00 1.35 1.00
Reaction (RV) 1.00 1.00 1.00 1.00

Load to section 1-1


SV SH SM
Comb (kN) (kN) (kN•m)
I -1107 0 -914

Page 22
TUONG CHAN

Date Doc. No.


15-Dec-23

SEGMENT 1 - CONCRETE RETAINING WALL ON RING ROAD No3 Sign Page:


TEDI
RETAINING WALL CALCULATION
II -1154 0 -926
III -1107 0 -914
VI -1154 0 -926

RETAINING WALL LOADS TO SECTION 2-2


Area Length Force X1 Arm Moment
Description (m2) (m) (kN) (m) (m) (kN•m)
Selfweight
Section C 0.90 15.000 331 1.750 -0.750 -248
VERTICAL LOADS

Concrete Total - - 331 - - -248


Soil weight
Section S1 7.50 15.000 1985 1.750 -0.750 -1488
Soil Total - - 1985 - - -1488
LL Surcharge - 15.000 - 1.750 -0.750 -
Piles reaction
Longitudinal force 309 -0.500 -155
Momen -280
Reaction Total - - 309 - - -435
Notes: 1. Distance 'X' is measured horizontally from Toe of Retaining wall to C.G. of Section
2. Moment 'Arm' is measured from Pile C.G. Horizontally and from Underside of Footing Vertically

SUMMARY LOADING TO SECTION 2-2


Applicable SV SH SM
Description Factors (kN) (kN) (kN•m)
Dead Load (DC) g bD 331 - -248
Earth on footing (EV) g bE 1985 - -1488
Reaction (RV) g bR 309 - -435
Live Load Surcharge (LS) g bL - -

Combination 1 (Strenght - I -1) 1.25DC+1.35EV+ 1.75 LS+1RV


Combination 2 (Strenght - I -2) 0.9DC+1EV+ 1.75 LS+1RV
Combination 3 (Extreme event -IA) 1.25DC+1.35EV+ 0.50LS +1RV
Combination 4 (Extreme event -IB) 0.9DC+1EV+ 0.50LS+1RV

LOAD FACTORS
LOADS COMBINATIONS
I II III IV
Dead Load (DC) 1.25 0.90 1.25 0.90
Earth on footing (EV) 1.35 1.00 1.35 1.00
Reaction (RV) 1.00 1.00 1.00 1.00
Live Load Surcharge (LS) 1.75 1.75 0.50 0.50

Load to section 2-2


SV SH SM
Comb (kN) (kN) (kN•m)
I 3402 0 -2754
II 2592 0 -2146
III 3402 0 -2754
VI 2592 0 -2146

Page 23
NORTH THANG LONG-VAN TRI PROJECT Date Doc. No.
###
BRIDGE NAME WALL AT OVERPASS BRIDGE Sign Page:
JOB check section 2-2 of footing

1. Load case

Load Factored
P (KN) V (KN) M(KN.m)
126 187 374

2. Material Data
Compressive Strength of Concrete f'c= 25 Mpa
Yield Strength of Tension Reinforcement fy= 420 Mpa
Yield Strength of Compression Reinforceme f'y= 420 Mpa
Elastic Modulus of Steel Es= 200000 Mpa

3. Sections Data

Name Number Dia. Area


Tension steel 7 D19 1988
Compressive Steel 7 D16 1393

Name Sign Unit Value


Height of Section h m 700
Width of Section b m 1000
Area of section A mm2 700000
Area of Tensile Steel As mm2 1988
Area of Compressive Steel A's mm2 1393
Distance from extreme compression fiber to the
ds mm
centroid of none pretressed tensile reinforcement 640
Distance from extreme compression fiber to the
d's mm 58
centroid of compression reinforcement
Effective depth de mm 640

4. Checking as a Flexural Member

d's
A'sfy
0 a
0.85f'cab

ds
h

A sf y
0

b
4.1 Flexural Resistance

Check condition for considering compression reinforcement


The distance from extreme compression fiber to the neutral axis
(Assumtion section has tension reinforcement only)
c=As*fy/(0.85*f'c*b1*b) = 46.22616 mm
The deepth of equivalent stress block
a=b1*c= 39.29224
The distance from extreme compression fiber to the compression reinforcement
d's= 58.00 mm
a< 2*d's, Assumtion section has tension reinforcement only is accepted

The nominal flexural resistance


Mn=As*fy*(ds-a/2) (Rectangular section)
The factored flexural resistance
Mr=f*Mn

Name Sign Unit Value


Factor b1 0.85
Distance from neutral axis to compressive face c mm 46.2
Nominal Flexural Resistance Mn KN.m 518.0
Resistance Factor f 0.9
Factored Flexural Resistance Mr KN.m 466.2
Momen of Section due to Loads M KN.m 374.0
Conclusion OK

4.2 Limits for reinforcement


4.2.1 Maximum Reinforcement
Obligation Condition
c/de<=0.42
de=ds (In case section has no prestressing steel)
Name Sign Unit Value
Distance from neutral axis to compressive face c mm 46.23
Effective deepth de 640
Conclusion OK

4.2.2 Mimimum Reinforcement


Due to component containing no prestressing steel
the minimum reinforcement shall be considered satisfied if
rmin>=0.03*(f'c/fy) (5.7.3.3.2-1)

Name Sign Unit Sec. 1-1


Ratio of tension steel to gross area rmin 0.00284
0.03*(f'c/fy) 0.00179
Conclusion OK

4.3 Shear
The effective shear deepth dv=max(0.9*de & 0.72h) (5.8.2.7)
Name Sign Unit Value
Effective shear depth(1) 0.9*de m 576
Effective shear depth(2) 0.72*h m 504
Effective shear depth(choosen) dv mm2 576
The nominal shear resistance is taken by the smaller value of :
Vn1=Vc+Vs
Vn2=0.25*f'c*bv*dv
In which
Vc=0.083*b*f'c(-2)*bv*dv
Vs=(Av*fy*dv*(cotgq+cotga)*sina)/s
To safe, the shear reinforcement can be ignored (Vs=0)
The determination value of b
The strain in the reinforcement on the flexural tension side
ex=(Mu/dv+0.5Nu+0.5Vu*cotgq)/(Es*As)

Name Sign Unit Value


Factored momen Mu KN.m 374.00
Factored axis force Pu KN 126.00
Factored shear force Vu KN 187.00
Effective shear depth (dv=ds-a/2) Sx=dv mm 620.35
Assumtion q value q 55.00
The strain in the reinforcement 1000*ex 1.84
Check again value of q in the table 55.00
Factor b taken from table b 1.3

Name Sign Unit Value


Effective shear depth dv m 576
Effective width bv m 1000
Factor b 1.3
Shear resistance of concrete Vc N 310752
Shear resistance of section (1) Vn1 N 310752
Shear resistance of section (2) Vn2 N 3600000

Checking the shear resistance


Name Sign Unit Value
Norminal shear resistance Vn KN 311
Resistance factor q 0.9
Factored shear resistance Vr KN 280
Shear due to Loads V KN 187
Conclusion OK

You might also like