Reference return Takisawa Fanuc turn-i

DS0300 (X)APC alarm: Need reference return


DS0300 (Z)APC alarm: Need reference return
DS0300 (T)APC alarm: Need reference return
DS0306 (X)APC alarm: Battery voltage 0
DS0306 (Z)APC alarm: Battery voltage 0
DS0306 (T)APC alarm: Battery voltage 0

1. Off – On the machine


2. Bring X and Z axis to machine home position. (X=130mm, Z=to tailstock pin lock)
3. Press off/set key
4. Set parameter enable key
5. Go to parameter 1815
6. Set x axis APZ and z axis APZ to bit 1
7. Set parameter disable key
8. (ON/OFF) the machine. Then Re start
9. Check if the X and Z axis is in reference machine home
10. Reference the X, Z, and C axis
11. Set parameter enable key
12. Go to parameter 1815
13. Check T axis APZ=0 (to enable k0014 bit 6) turret rotation OK
14. Go to MNT the to Keep relay function
15. Go to K0013.0 to K0013.2 then set to bit 1 (Turret reference operation, Turret reference
ON)
16. Press spindle override to disengage turret
17. Go to MNT the to Keep relay function
18. Go to K0014.2 then set bit to 1 (turret pin unlock)
19. Go to K0014.6 then set bit to 1 (turret rotation OK)
20. Move the turret assy one rotation then direct it to tool no.1.
21. Go to K0014.2 then set bit to 0 then set K0014.1 to bit 1 (A sound confirming turret pin lock
is established)
22. Go to K0013.0 to K0013.2 then set bit 0
23. Go to parameter 1815
24. Set T axis APZ=1 (to stablish the new position)
25. Press off/set key
26. Set parameter disable key
27. Off – On the machine
28. Cycle the turret

You might also like