You are on page 1of 4

Client : Prime AE Date : 12.20.

2023
Project : FCCC 2B Designed by :.................
Project No : Checked by : ................

Franklin County Corrections Centre Phase 2B 2551


Fisher Road, Columbus, OH-43204
Lateral Load Resisting System

Lateral Design Parameters

Seismic Design Parameters

Importance Factor Ie = 1.25


Ris Category = III
Height of building h = 56
Ss = 0.121
S1 = 0.062
SD1 = 0.07
SDs = 0.097
Site class = C
Seismic Category = B
Respose Reduction Factor R = 4
Seismic Coefficient Cs = 0.030313
Long Period Transistion TL = 12
Ct = 0.02
x = 0.75
Time period T = 0.409422
Cs = 0.053429

Seismic Coefficient Cs = 0.030313


Basic Seismic force resisting system = Ordinary Precast Shear walls
Analysis Procedure = Equivalent Lateral Force

Wind Design Parameters

Basic Wind Speed V = 120 MPH


Ris Category = III
Exposure = V
Internal Pressure Coefficient = +/- 0.18
Client : Prime AE Date : 12.20.2023
Project : FCCC 2B Designed by :.................
Project No : Checked by : ................
Loads and Applied Forces
Client : Prime AE Date : 12.20.2023
Project : FCCC 2B Designed by :.................
Project No : Checked by : ................
Client : Prime AE Date : 12.20.2023
Project : FCCC 2B Designed by :.................
Project No : Checked by : ................

Centre of Mass & Rigidity for Roof

Red colour Center of mass


Blue colour Center of rigidity

Centre of Mass & Rigidity for Pent

Red colour Center of mass


Blue colour Center of rigidity