THAKUR INFRA Thak ur Infra Solu tions end Engineering Congultantg


Y o u D rt l l"\ II WI B u il d II

Date: 02/ 11 / 2023

Sub ject: SBC repmt for propo sed construc tion of Resident ial B uild ing

Sir/ Madam
As per the above request, We would wish t inform you that th e requ ired and necessary tests were
conducted on the Soil Samples Received in our Laboratory from the be low-ment ioned si te lo cation, Res u lt
have been tabulated for your perusal.

Depth of An gle of Recommen d ed


Dry Density Cohesion
sampl es Internal SBC of soil i n
SI No.. Location Type of soil in "C" in
collected in gm/cc KN/Sqm Friction in T/Sqmts
Mts.* Deerees
Pit-1 Red Murrum
1 1.50 1.86 29 18 16
Sample-1 Gravelly Soil

T IS:2720 Part Mode of Test


e 13 (1986) Direct Shear (Angle of Friction
s Reaffirmed & Cohesion)
t 2021
M
e
t
h
o
d
Note: 1.The above Results are Valid for the given site, and for the Supplied Soil Samples only.
2. Mode of Test: Direct Shear Test
3. Ref:IS:6403-1981:Th,e factor of Safety adop ted is 3.00
4. Analysis is done based on Local shear failure condition
5. Size of the foundation consider for the determination of SBC is l.Sm *l.Sm

C.E.O

Thakur Infra - Laboratory Division


Email : thakurin fralab@gma il.com, hltp: // thakur in frasolnt
jons.com,
S . M-266, M.T. Saga r, 1st Gate, Golml Road, Hubballi-
580021