You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

L
CITY OF LOS ANGELES
DEPARTMENT OF PUBLIC WORKS
BUREAU OF ENGINEERING
THE CITY OF LOS ANGELES OR ITS OFFICERS OR AGENTS SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF ELECTRONIC COPIES OF THIS PLAN SHEET.

STANDARD ADU

THIS PLAN WAS ELECTRONICALLY


K

SIGNED AND STAMPED


PLOT PLAN OWNER INFO FLOOR AREA PLAN ALTERNATE LAYOUTS SHEET INDEX
5' - 0"
INSTRUCTIONS FOR APPLICANT: NAME: ERIK VILLANUEVA

_ _ _ SF _ _ _
+ COMPLETE PROJECT SPECIFIC

_
443 ____

___
T O U A D S E :_ _ E :
INFORMATION IN THE BOXED AREA
ADDRESS: 1149 S. BROADWAY
GENERAL

Y O H O U C OD

___
LOS ANGELES, CA 90015
5' - 0"

+ COMPLETE PLOT PLAN:


J 43'-0" G-0.0 COVER SHEET

(E ) NI NG
+ SHOW FOOTPRINT OF EXISTING

T A U:
G-0.1 GENERAL AND GREEN NOTES
PRIMARY DWELLING WITH SQUARE
G-0.2 GREEN NOTES

ZO
FOOTAGE LABELED

L:
+ LABEL ADJACENT STREETS
APPLICANT INFO G-0.3 TITLE 24
+ LABEL PROPERTY LINE
C G-0.4 TITLE 24
+ LABEL EASEMENTS IF ANY NAME: KADRE ARCHITECTS
+ ADD DIMENSIONS FOR LOT SIZE D
19'-0"

+ ADD DIMENSIONS FOR YOU ADU ADDRESS:


+ IF GARAGE, INDICATE IF DEMO YOU ADU 1240 BROOKMERE STREET ARCHITECTURAL

BUREAU OF ENGINEERING
INTENDED PASADENA, CA 91105
A-2.0 FLOOR PLAN
+ ANNOTATE PLOT PLAN WITH NOTES A-2.1 ROOF PLAN
PER BELOW A-3.0 ELEVATION
+ INDICATE ORIENTATION OF NORTH (E) GARAGE,
H ON NORTH ARROW, BELOW
+ ADD DIMENSION DISTANCE FROM
31'-0"
DEMO UNDER
SEPARATE
PROJECT DATA A-3.1
A-4.0
ELEVATION
SECTIONS
PROPERTY LINE

A-5.0 INTERIOR ELEVATIONS

LOS ANGELES, CALIFORNIA


23'-0"

EXISTING STRUCTURE
+ COMPLETE VICINITYTO YOU ADU
PLAN: PERMIT A-7.0 SCHEDULES
+ COMPLETE
INSERT AN IMAGE SHOWING
PLAN: THE ADDRESS:

_ _ _ SF _ _ _

1 STANDARD PLAN WAY


+ VICINITY A-8.0 DETAILS
COMPLETE
INSERT ANBLOCK
IMAGEAND ADJACENT K

T O U A D S E :_ _ DE :
+ SHOWING THE

_
EXISTING RESIDENCE: YOU ADU: A-8.1 CASEWORK DETAILS

443 ____

___
STREETS. BLOCK AND ADJACENT
COMPLETE

Y O HO U G CO
+ LABEL SITE LOCATION.

___
STREETS. 5519 E ALLAN ST

STANDARD ADU
+ LABEL
IF LESSSITE
THAN 1/2 MILE, SHOW B

COVER SHEET
+ LOCATION. LOS ANGELES, CA 90032

(E) ILDIN
DISTANCE
+ TO NEAREST
IF LESS THAN 1/2 MILE,PUBLIC
SHOW STRUCTURAL

T A U:

HORIZONTAL CONTROL:
TRANSPORTATION
DISTANCE TO NEARESTFOR ADU PARKING
PUBLIC H
EXISTING RESIDENCE AREA:

BU
EXEMPTION

L:

VERTICAL CONTROL:
TRANSPORTATION FOR ADU PARKING S0.00 GENERAL NOTES & SHEET LIST
EXEMPTION PROPOSED ADU
122'-0"

S0.10 TYPICAL CONCRETE DETAILS


+ COMPLETE FLOOR AREA PLAN: EXISTING TYPE: S0.20 TYPICAL WOOD DETAILS
G + COMPLETE
+ ADD THE SQUARE
FLOORFOOTAGE OF
AREA PLAN: 5519 1/2 E ALLAN ST

SHEET TITLE:
S0.21 TYPICAL WOOD DETAILS
EXISTING RESIDENCE.
+ ADD THE SQUARE FOOTAGE OF SINGLE S0.23 TYPICAL WOOD DETAILS

ADDRESS:
PROJECT:
+ COMPLETE
EXISTING SUMS FOR EACH AREA
RESIDENCE. APN:
CALCULATION.
+ COMPLETE SUMS FOR EACH AREA
FAMILY S1.00
S8.1
FOUNDATION AND ROOF FRAMING PLANS
CASEWORK DETAILS
CALCULATION. HOME EXISTING RESIDENCE AREA:
ZONE: 937 SF
937 SF A
NOTES:
A. EXISTING RESIDENCE TYPE:AREA:
SITE SINGLE FAMILY RESIDENCE CODE NOTES
B. EXISTING DRIVEWAY
A. I
C. DIRECTION OF WATER DRAINAGE
B. APPLICABLE CODES:

BY

XXXXX
D. REAR YARD SETBACK _______FT
C. APN:
PARKING: 5220002905 2022 California Building Code, with 2023 LA City
J

CIP NO.
D.
E. SIDE YARD SETBACK _______FT REQUIRED PARKING: Amendments

___ S F ___
499 ____ :
TO U AD SE:__ TRICT
F. FRONT YARD SETBACK _______FT
E. ZONE: 2022 Green Building Code, with 2023 LA City
PF-1

_
F

___
G. EXISTING WATER CONNECTION
F. Amendments

DATE
G.
H. EXISTING SEWER CLEANOUT

YO HOU DIS
2023 LABC

___
E SITE AREA: PARKING: 5000 SF
I. EXISTING ELECTRICAL PANEL
H. PROPOSED 2023 LARC

(E) HOOL
J.
I. EXISTING MAILBOX LOCATION

T A U:
K. NEW USPS APPROVED MAIL BOX
J. CONSTRUCTION TYPE:
PARKING:

SC
UNIT, FINAL LOCATION TO BE Type V-B

L:

XXXX XXXXXX
APPROVED BY POSTMASTER REQUIRED PARKING: 1 SPACE
K. EXISTING TREE
L. DISTANCE SEPARATION BEWTEEN OCCUPANCY CLASSIFICATION:
G LEGAL DESCRIPTION:

DEPARTMENT OF PUBLIC WORKS


L. ______________
PROPOSED ADU AND EXISTING

SHEET TYPE
2022 California Building Code Chapter 3
PRIMARY DWELLING ________FT Proposed Occupancy - Section 310 - Group R
F PROPOSED PARKING: 1 SPACE

REVISION DESCRIPTION
M. PARKING AREA
N. EXISTING GARAGE
O. EXISTING TREE ALLOWABLE BUILDING HEIGHT AS PER TABLE
P. _______________
E A FIRE SPRINKLERS: ZONING CODE:
504.3:
ALLOWABLE HEIGHT ABOVE GRADE PLANE: 20'
937 SF
(E) HOUSE:_________ PROPOSED HEIGHT: 14'-11"
YES
YOU ADU: 443 SF ALLOWABLE STORIES AS PER TABLE 504.4
NORTH ARROW EAST ALLAN STREET X NO 1380 SF
TOTAL: __________ ALLOWABLE NUMBER OF STORIES R OCC: 2
PROPOSED NUMBER OF STORIES: 1

D-XXXXX
Fire Resistance Rating Requirements for Building

INDEX NO.
VICINITY PLAN MATERIALS CONCEPTUAL RENDER Elements (per Table 601)
Primary Structural Frame: 0
Bearing Walls - Exterior: 0
SIDING ROOF PAINT Bearing Walls - Interior: 0
Non-Bearing Walls - Exterior: 0

NO.
D Non-Bearing Walls - Interior: 0
STUCCO ASPHALT SHINGLES X WHITE Floor Construction: 0
X FIBER CEMENT X STANDING SEAM METAL ROOF OTHER Roof Construction: 0

CITY ENGINEER
OTHER

DATE:

DATE:
IF LOCATED LESS THAN 3 FEET FROM AN
ADJACENT STRUCTURE, 1 HOUR FIRE RATING
TRELLIS PARTITION CASEWORK DOOR AND WINDOW FRAME REQUIRED FOR EXTERIOR WALLS AND OPENINGS
TO BE PROTECTED.
X YES X YES X WHITE
NO NO MATCH PAINT

DEPUTY CITY ENGINEER/ PROGRAM MANAGER


OTHER
C
PROJECT DESCRIPTION

GARY LEE MOORE, P.E., ENV SP

CITY ENGINEER
PROJECT DESCRIPTION: DEFERRED SUBMITTALS:
ADU Standard Plan Program: 1 Story, 1 bedroom, with options (445 THE FOLLOWING IS A LIST OF CONTRACTOR PROVIDED
SF). DESIGN/BUILD, DELAYED REVIEW / DEFERRED APPROVAL
Slab on grade. If located in a Methane Zone, standard LADBS slab ITEMS FOR SUBMITTAL AND REVIEW BY THE CITY OF LOS
on grade to be provided. Gable roof, advanced framing (wood), ANGELES DEPARTMENT OF BUILDING AND SAFETY.

PROJECT ISSUE DATE: Issue Date


stucco or fiber cement board siding (SFM APPROVED FIRE

CITY OF LOS ANGELES


RESLIENT MATERIALS). All electric. Kitchen and bathroom. 1. LOCATION AND SIZE (BTU/HR OUTPUT) OF HVAC EQUIPMENT
B 2. LOCATIONS AND DIMENSIONS OF PLUMBING SUPPLY
PROPOSED AREA: 445 SF 3. LOCATIONS OF OUTLETS, FIXTURES, SWITCHES, AND
PROPOSED HEIGHT: 14'-11" SMOKE DETECTORS, AND SIZES OF SUBPANELS AND MAIN
PANELS
PARKING REQUIREMENTS: 4. ELECTRIC VEHICLE SUPPLY WIRING
ONE SPACE IS REQUIRED UNLESS
1) LOCATED WITHIN 1/2 MILE WALKING DISTANCE FROM A UNDER SEPARATE PERMIT:
BUS OR RAIL STOP, 1. DEMOLITION PERMIT (IF NEEDED)
2) ONE BLOCK FROM A DESIGNATED CAR SHARE PICKUP
5519 E ALLAN STREET OR DROP OFF LOCATION, SITE SPECIFIC PLAN CHECK REVIEW:
NOT TO SCALE WORK ORDER
(DESIGN STAGE ONLY)

3) WITHIN AN APPLICABLE HISTORIC DISTRICT THE FOLLOWING IS A LIST OF ITEMS THAT WILL BE REVIEWED

Project Status
REPLACEMENT PARKING IS NOT NEEDED WHEN A GARAGE, DURING THE SITE SPECIFIC PLAN CHECK. 2002
N CARPORT OR PARKING STRUCTURE IS DEMOLISHED IN
REVISION DATES

A CONJUNCTION WITH ADU CONSTRUCTION. 1. METHANE MITIGATION


SHEET NAME
2. GRADING PRE-INSPECTION
3. LOW IMPACT DEVELOPMENT REQUIREMENTS
4. VHFHSZ FIRE ZONE REQUIREMENTS
5. SPECIFIC PLAN
LADBS STAMP
G-0.0
SHEET OF SHEETS

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
SHEET VERSION 4.0.1