You are on page 1of 6

PHOTON Laboratory GmbH

Jülicher Straße 376


52070 Aachen
Germany
Tel.: +49‐241‐4003‐0

Test Report
Photovoltaic module performance measurement
Report number: 10341‐1

PHOTON Laboratory GmbH, Jülicher Straße 376, 52070 Aachen, Germany, Tel.: +49‐241‐4003‐0
Order Information
Order number: 10341
Order date: 2012‐10‐18
Customer number: 343366
Customer address: Znshine PV‐Tech Co., Ltd.
No.1 Zhixi Industry Zone, Jintan Town
213251 Changzhou, Jiangsu Province

Testing facility: Photon Laboratory GmbH


Jülicher Straße 376
52070 Aachen
Responsible: Dr. Andreas Rosenberger

Tests performed
PID‐Test
For the PID‐Test the module’s glass surface is covered with aluminum foil and exposed to a high
negative potential of ‐1,000 V at 25° C for the duration of 168 hours. This arrangement simulates a
module’s active life of a few years in only seven days. Prior to this treatment, the modules'
electrical perfomance is measured at STC, as well as an electroluminescence image is captured,
and the same measurements are repeated after the potential exposition. The comparison of the
mesurement results gives information about the modules' sensitivity to PID.

PHOTON Laboratory GmbH, Jülicher Straße 376, 52070 Aachen, Germany, Tel.: +49‐241‐4003‐0
Report 10341‐1 Page 2 of 6
Module Data
The modules tested are listed as follows:

Manufacturer: ZNSHINESOLAR
Module model ZX240(30)P
Cell technology poly‐crystalline‐Si
Dimensions 1650 x 992 x 40 mm³
Photon Module‐ID Serial number
10721 8327233926130002
10722 8627233926130001

Total quantity of tested modules: 2

PHOTON Laboratory GmbH, Jülicher Straße 376, 52070 Aachen, Germany, Tel.: +49‐241‐4003‐0
Report 10341‐1 Page 3 of 6
Module Qualification ‐ PID‐Test
This section gives the measurement results and electromuminescence images prior to and after
the exposition to high‐voltage potential.
Module‐ID: 10721 Potential: ‐1000 V
Test begin: 2012‐10‐17 Duration: 168 hours
Pmpp Vmpp Impp Voc Isc Module Cell Fill‐factor
efficiency efficiency
Initial state results 241.13 W 29.29 V 8.23 A 37.67 V 8.88 A 14.73 % 16.51 % 72.05 %
Post‐test results 242.23 W 29.51 V 8.21 A 37.7 V 8.87 A 14.8 % 16.59 % 72.46 %
Deviation absolute 1.1 W .23 V ‐.03 A .02 V ‐.01 A .07 PP .08 PP .41 PP
Deviation relative .46 % .77 % ‐.32 % .06 % ‐.16 % 0% 0% .01 %

Electroluminescence initial state:

Electroluminescence post‐test:

PHOTON Laboratory GmbH, Jülicher Straße 376, 52070 Aachen, Germany, Tel.: +49‐241‐4003‐0
Report 10341‐1 Page 4 of 6
Module‐ID: 10722 Potential: ‐1000 V
Test begin: 2012‐10‐17 Duration: 168 hours
Pmpp Vmpp Impp Voc Isc Module Cell Fill‐factor
efficiency efficiency
Initial state results 240.55 W 29.39 V 8.19 A 37.51 V 8.81 A 14.7 % 16.47 % 72.77 %
Post‐test results 238.07 W 29.23 V 8.15 A 37.53 V 8.81 A 14.55 % 16.3 % 72.04 %
Deviation absolute ‐2.47 W ‐.16 V ‐.04 A .02 V ‐.01 A ‐.15 PP ‐.17 PP ‐.73 PP
Deviation relative ‐1.03 % ‐.53 % ‐.5 % .06 % ‐.08 % ‐.01 % ‐.01 % ‐.01 %

Electroluminescence initial state:

Electroluminescence post‐test:

PHOTON Laboratory GmbH, Jülicher Straße 376, 52070 Aachen, Germany, Tel.: +49‐241‐4003‐0
Report 10341‐1 Page 5 of 6
Terms of use
PHOTON Laboratory GmbH, Jülicher Strasse 376, 52070 Aachen, Germany

Using the test report

The test report is protected by copyrights. The test report may be published under the following conditions:

1. The test report may only be reproduced in its original, complete form, i.e. it is forbidden to change, alter,
add, or remove elements of the report for the purpose of publication or circulation to a third party, nor is it
allowed to circulate just a portion of the test report to a third party.

2. It is forbidden to share a version of the test report that consists of wording or interpretations made by
the ordering party that deviate from that in the test report.

3. When circulating the test report to a third party, readers should be able to recognize im‐mediately and
clearly that this document is a test report from PHOTON Laboratory GmbH. Furthermore, the test date in
the report should be visible. The following wording should be used when making this reference: “The test
report was produced by PHOTON Laboratory GmbH on 31.10.2012 under the log number 10341‐1.

4. It is forbidden to publish the test report for the purpose of advertising purposes if the manufacturer has
altered product characteristics mentioned in the report after the date of the test.

5. When sharing the test report, or referring to the test report, references should only be made to the test
subject identified by serial number. It is forbidden to use, directly or indirectly, the test report to refer to all
products in a product series.

6. PHOTON’s logo is copyrighted and trademark protected. The logo may only be reproduced as part of the
complete test report with written approval from PHOTON Laboratory GmbH.

PHOTON Laboratory GmbH, Jülicher Straße 376, 52070 Aachen, Germany, Tel.: +49‐241‐4003‐0
Report 10341‐1 Page 6 of 6