You are on page 1of 9

SHIP-PPC East-West Highway Kakarbhitta-Laukahi Section

Luancching Appron Slope Bank Prot


Revetment Type, H EW GT GW GN GT
3*0.5 2.50*0.50 Type A 2.75 2.5 2.75 15.125 2.5
5*1 4*.5 Type B 7 4 7 38.5 4
3*0.5 4*0.50 Type C 2.5 2 2.5 13.75 2
River Training Works 3*0.6 5*0.51 Type D 4 4 5 22 5
2 Type E 2.25 4 2 22 2
2.5 Type F 2.5 52.5 27.5 2.5
3 Type G 2.5 6 3 33 3
4 Type H 2.75 8.5 4 46.75 4
Type I 1.5 3.5 4 19.25 4
5*1 5*.5 Type J 5 7.5 5 41.25 5
River Training River Training (From field visit) Type E/W, Cum Gabion Fill, Cum Gabion Net, Sqm Geotextile, Sqm
SN Chainage River/Khola U/S D/S U/S D/S River Training Type Remarks US DS US DS US DS US DS US DS
R/B L/B R/B L/B R/B L/B R/B L/B RB LB RB LB RB LB RB LB RB LB RB LB RB LB RB LB RB LB RB LB
32 45+910 Geuria Not Required 78.64 2267.1 290.16 120.79
Launching apron Embankment but
(15x1m thick) with Launching apron only launchning pad
slope bank (15x1m thick) with & slope mattress J J J J 1000 75 1500 112.5 8250 618.75 1000 75
protection of 3m slope bank protection requiredon Existing
33 47+990 Ratuwa 200m 15m height of 3m height embankment.
34 52+510 Dhardhare Not Required
35 52+850 Betani 20m 20m 30m 30m 2.0m Height 2.5m Height Revetment Type E E F F 45 45 75 75 80 80 150 150 440 440 825 825 40 40 75 75
36 54+150 Bhutre Not Required

Embankment but
only launchning pad
A A A A 687.5 687.5 412.5 412.5 687.5 687.5 412.5 412.5 3781.3 3781.3 2269 2269 625 625 375 375
& slope mattress
4m height embankment type with 3m height slope bank protection with requiredon Existing
37 54+750 Mawa 250m 250m 150m 150m launching apron (0.5m) thick launching apron (0.5m thick) embankment.
38 55+100 Mawa Branch Existing
protection Embankment but
with only launchning pad
launching & slope mattress H B B 825 2100 2100 2550 2100 2100 14025 11550 11550 1200 1200 1200
apron (0.5m requiredon Existing
39 57+550 Bakra 300m 300m 300m 4.0m Height thick) 4m height embankment embankment.
40 58+440 Solti 50m 50m 50m 70m 2.5m Height 3.0m Height 2.5m Height 3.0m Height Revetment Type F G F G 112.5 125 112.5 175 200 300 200 420 1100 1650 1100 2310 100 150 100 210
41 60+480 Sanjhora 80m 80m 30m 30m 2.5m Height 3.0m Height 2.5m Height 3.0m Height Revetment Type F G F G 180 200 67.5 75 320 480 120 180 1760 2640 660 990 160 240 60 90
42 63+630 Pathari 20m 100m 2.5m Height 2.5m Height Not required Irrigation canal Revetment Type F F 45 225 80 400 440 2200 40 200
43 64+940 Dans 50m 200m 200m 2.5m Height Not required 3.5m Height Revetment Type F G G 0 0 500 500 0 0 1200 1200 0 0 6600 6600 0 0 600 600
44 65+620 Morangi 25m 30m 20m 2.5m Height 6.0m Height 3.0m Height Irrigation canal Revetment Type F H G 56.25 50 0 10 18 0 550 660 0 50 168.75 0
45 69+930 Chisang 1 Not Required
46 70+330 Chisang 2 100m 50m Not required 3.5m height slope bank protection
3.5m Height Revetment type
Embankment G G 250 125 600 300 3300 1650 300 150
47 74+530 Chisang Bhangabari Revetment Type
48 76+330 Betna Not Required
49 78+250 Lohendra 200m 150m 140m 50m Embankment 700 525 490 175 1200 900 840 300 6600 4950 4620 1650 1000 750 700 250
50 79+460 Lalbhitti 20m 20m 2.5m Height Revetment Type Not Required G G 50 50 120 120 660 660 60 60
51 80+570 Sukuna Paini Not Required
52 80+680 Sukuna Existing
53 82+190 Jharana Not Required
54 84+660 Madhyali Not Required
55 84+960 Mada Not Required
5417 11195 50450 5690

SOOSUNG/ERMC/TSE River Training


River Training Works, Landmark Bridge

River Training
SN Chainage River/Khola U/S D/S
R/B L/B R/B L/B
3 5+460 Ninda Khola
14 22+950 Biring 100m 100m

16 29+530 Kankai 400m 300m 100m 100m

33 47+990 Ratuwa 100m 15m

39 57+550 Bakra 300m 300m 300m


49 78+250 Lohendra 150m 150m 50m 50m
River Training (From field visit)
U/S
R/B L/B

3.0m Height

Slope bank protection (4m height) with 15mx1m thick launching apron

Launching apron (15x1m thick)


with slope bank protection of
3m height

Slope bank protection with


4.0m Height launching apron (0.5m thick)
er Training (From field visit)
D/S
R/B L/B

3.0m Height

n (4m height) with 15mx1m thick launching apron

Launching apron (15x1m thick) with


slope bank protection of 3m height

4m height embankment
Luancching Appron Slope Bank Protection Revetment Type, H
3*0.5 2.50*0.50 Type A
5*1 4*.5 Type B
3*0.5 4*0.50 Type C
3*0.6 5*0.51 Type D
2 Type E
2.5 Type F
3 Type G
4 Type H
Type I
5*1 5*.5 Type J
Type
River Training Type Remarks US DS
RB LB RB LB
Not Required
Revetment Type G G G G
Embankment but only
launchning pad & slope C C C C
mattress requiredon Existing
embankment.

Embankment but only


launchning pad & slope J J J J
mattress requiredon Existing
embankment.
Embankment but only
launchning pad & slope H B B
mattress requiredon Existing
embankment.
Embankment
EW GT GW
2.75 2.5 2.75
7 4 7
2.5 2 2.5
4 5 4
2.25 2 4
2.5 2.5 5
2.5 3 6
2.75 4 8.5
1.5 4 3.5
5 5 7.5
E/W, Cum Gabion Fill, Cum
US DS US DS
RB LB RB LB RB LB RB LB

250 250 600 600

1000 750 250 250 1000 750 250 250

2750.00 3450.00

500 75 750 112.5

825 2100 2100 2550 2100 2100

525 525 175 175 900 900 300 300


7000.00 10012.50
GN GT
15.125 2.5
38.5 4
13.75 2
22 5
22 2
27.5 2.5
33 3
46.75 4
19.25 4
41.25 5
Gabion Box , Sqm Geotextile, Sqm
US DS US DS
RB LB RB LB RB LB RB LB

3300 3300 300 300

5500 4125 1375 1375 800 600 200 200

18975.00 2400.00

4125 618.75 500 75

14025 11550 11550 1200 1200 1200

4950 4950 1650 1650 750 750 250 250


55068.75 6175.00
(3+12)/2=7.50
22.5 5 sqm 2

Embankment filling Grass Plantation Brush Lay

3375 3375 1125 1125 750 750 250 250 300


9000.00 2000.00
0.2

Brush Layering Tree Plantation

300 100 100 75 75 25 25


800.00 200.00

You might also like