1) Location:
Locate the vacuum pump on a level surface that is clean, well lit, well ventilated and capable taking the weight
of the pump. The entire length of the frame base must be supported. Shim where necessary (do not use wood).
Ambient temperature should not exceed temperatures listed on the specifications. A
requirements of the List of Prohibited Substances
All materials supplied are in compliance with the
3) Ventilation:
The inlet grid(s) and ventillation fan should be installed in such a way that any recirculation of cooling air
to the inlet grating of the vacuum pump is avoided. The air velocity to the grid(s) has to be limited to 5m/s.
A ( 1 : 10 ) The maximum air temperature at intake opening is 46 °C (115 °F), ( minimum 0 °C / 32 °F )
Ventilation alternative 1 and 3 : The required ventilation to limit vacuum pump room temperature can be D
ISOLATION VALVE calculated from :
Qv = 1.06 N / T
Where,
Qv = Required cooling air flow (m³/s)
Allow sufficient space (1m of clearance on all sides and top of the vacuum pump) N = Nominal motor power of vacuum pump (kW)
for safe and proper installation, daily inspection and maintenance. T = Temperature increase in compressor room. ( °C)
Ventilation alternative 2 and 4 : The fan capacity should match the vacuum pump- fan capacity at a pressure head E
equal to the pressure drop caused by cooling air ducts.
Max. allowable pressure drop in ducting before or after the vacuum pump = 10 Pa
1m
copied, used for manufacturing or communicated to any other person or company.
F
Tolerances, if not indicated, according to:
Material
Not Applicable Public
Treatment
Not Applicable INV
CONFIDENTIAL:
Ed Posi-
tion
Modified from Date Intr./Appd. Parent 3D model Ed . Version 3D Preliminary
Des checked. Prod checked. Approved. Date
26/09/2014 9820726231