7. Upon prying above the arcgate, suddenly the hang up fell and hit his pry bar where it
was hitch at the concrete back pinning his right hand 3rd and 4th digit fingers.
8. He was able to release his hand while the pry bar fell and was recovered by Engr.
Legaspi.
9. Other IPIC findings:
a. There was a wide gap (about 6”) above the arcgate due to worn out bumper.
b. The deep of the hang up boulder was about 7-8 “ from the tip of the arcgate
which could be easily be seen prompting him to pry it on the wide gap.
c. He uses a prybar with about 6’ X 1” diameter.
d. He was an old timer chute tapper assigned at the CHC Loading area.
e. He knows the SJP that prying above the arcgate is strictly prohibited due to
the risk involve but he was tempted to do it above the arcgate as he was
tempted and is easier to bring down the hang up boulder.
2 PMC_IPIC_2023
Corrective actions.
1. Conduct chutes audit MCOHD COB Dec. 15, 2023
to repair worn out Supervisors
bumpers. APA
JAO
2. Review the length of J. Legaspi COB Dec. 15, 2023
pry bar applicable in
every chute and FBC Planners APA
integrate in the JAO
SOP/SJP.
3. Install warning MCOHD COB JANUARY 20,
placards prohibiting Supervisors 2023
prying above APA
arcgates. JAO