• Dead Loads: Dead loads are the loads in which the weight of all components at each level included, like the different member
from roof including roof finishes, slabs, beams water tanks, Parapets, elevator machine room etc. and it also including
plastering of all components and surface cladding etc., also at each floor level there is also including fixed masonry or other
partitions, infill walls, columns, roof slabs and beams, staircase weight, cantilever balconies, parapet walls and plastering or
cladding wherever used. The unit weights for different material may be taken from IS: 875 (Part 1). • Imposed Floor Loads: IS
875 (Part 2) is an Indian code that defines the criteria to apply the imposed loads on different members like roofs, floors,
stairs, balconies, etc., for various occupancies. There is also a provision for a reduction in the imposed loads for certain
situations, for e.g. large span beams and a number of storey at the top of the columns of a storey. • Lateral loads: The
earthquake code IS: 1893 -2002 (Part 1) permits us the general reduction in roof and floor imposed load when we consider the
different load combination with the earthquake loading.