You are on page 1of 46

Sr.

No Description Statement of
Compliance
(1) (2) (3)
1. INTRODUCTION
1.1 System shall provide inter-operability of hardware, OS, software,
networking, printing, database connectivity, reporting, and
Complied
communication protocols. System expansion shall be possible through
off-the-shelf available hardware.
1.2 The equipment offered shall be compact, fully solid state highly reliable
Complied
and shall use latest state of the art technology.
1.3 The equipment offered shall be designed for continuous operation (24-
hours a day and 365-days a year). The design life of the equipment
shall be a minimum of SIX YEARS. This life shall achievable through Complied
normal and regular periodic maintenance during the period of
Warranty and Comprehensive AMC.
1.4 Equipment with better or higher technical specifications shall be
accepted. Complied
Note: -Original Equipment Manufacturer (OEM) of Cameras, Servers,
Storage (NAS/SAN) box, Workstations, Monitors, UPS and Switches
shall be ISO firms & the offered products must be certified for Complied
Safety, Electrical and Emission of International standards such as
CE/EN/UL/FCC/ROHS/BIS etc.
1.5 The equipment offered by the bidder shall be of standard and
Complied
reputed branded make.
1.6 All offered equipment shall be manufactured to withstand
continuous operation safely without undue heating, vibration, wear, Complied
corrosion, electromagnetic interference or any similar problems.
1.7 System architecture shall be open for future expansion. Complied
1.8 System shall be provided with servers configured to operate in
Automatic Failover changeover mode without any need of any
Complied
manual intervention. During change over there shall be not be any

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


loss of data.
1.9 There shall be a Control System with Video Control Software to manage
Complied
all the video surveillance devices.
1.10 All types of spares and spare modules of the offered equipment shall be
readily available with the successful bidder and its OEM partner during
entire life time of the equipment for maintenance, repairs and up keep Complied
of the equipment (03 years of warranty and 03 years of post-
warranty Comprehensive AMC period).
1.11 The bidder shall undertake and ensure successful implementation of the
offered solution, keeping in view the safety and protection of personnel
during normal operation and maintenance or during malfunctioning of
Complied
any equipment or its sub component. This shall be ensured as an
integrated feature of design, manufacture and installation by the
System Integrator.
1.12 All interconnecting cables in offered equipment shall also be
appropriately labelled to facilitate convenient interconnection and Complied
minimize chances of incorrect connection.
1.13 All cables required to interconnect the equipment shall be supplied by
Complied
the bidder as a part of solution.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


1.14 All cables shall be fully assembled, connector pre-terminated and
Complied
factory tested at the time of supply as part of the overall system check.
1.15 Minimum requirement of specifications for all SCCTV equipment’s,
software and accessories, are shown here, if any vendor provides
Equipment, software and accessories with better specifications shall be
Complied
accepted. (OEM of Cameras, ANPR, Servers, Workstations, Monitors, PS
and Switches shall be ISO firms & the offered products must have
certification for safety & electrical compliance).
1.16 System shall be triplex i.e. it should provide facility of Viewing,
Complied
Recording & Replay simultaneously.
2. GENERAL SPECIFICATIONS
2.1. IP SCCTV System shall be suitable for commercial supply of 230 V (± 10%),
50 Hz. (± 5%) single phase AC and it shall be comprising of IP IR Digital
Outdoor & Indoor Color video Cameras, Network Switches, Network
Video Recorder/CAMERA SERVER. Storage system consisting of IP
Network, Attached Storage for period of 30 days (NAS)/Storage Area
Network (SAN) for recording, Application software with latest video
Complied
management System (SVMS), Color LED/LCD monitor with LED back
light, with workstation having Joystick controller/ Mouse-Keyboard for
viewing of live and recorded images with online UPS power backup
for minimum 30 minutes on full load and including with cabling and
conduit work as required at site. System shall have provision of
WAN connectivity for remote monitoring.
2.2 System shall facilitate viewing of live and recorded images and
controlling of all cameras by the authorized users present in the LAN/ Complied
WAN connectivity for remote monitoring.
2.3 LICENSES: All Hardware and Software component supplied by the bidder
shall be licensed in favor of Airports Authority of India and valid for the Complied
entire lifetime of SCCTV system.
2.4 Manufacturers Authorization Form (MAF) from concerned OEM
required to be submitted by the bidder confirming that the bidder is
authorized to quote the products of OEM and the offered products Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


should comply with the technical specification given in the tender
documents.
2.5 System shall provide inter-operability of hardware, OS, software,
networking, printing, database connectivity, reporting, and
Complied
communication protocols. System expansion shall be possible
through off-the-shelf available hardware.
2.6 IP based SCCTV System shall use video signals from various types of
indoor/outdoor CCD/CMOS color cameras installed at different
locations, process them for viewing, recording and replay and
simultaneously on all workstations/monitors at Central Control
Room/Local Control Rooms of all the cameras after compression
using H.264 or better standard. Joystick Controller/Mouse-Keyboard Complied
shall be used for Pan, Tilt, Zoom, Camera Selection and other functions
of desired cameras. When the viewing stream, recording stream and
analytic stream are set at the same FPS and resolution, the camera
shall send on the network a single multicast stream this shall help
reduce network Bandwidth.
2.7 System must provide built-in facility of Water-marking & Digital Certificate Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


to ensure tamperproof recording so that these can be used as evidence at
a later date. The recording shall support audit trail feature.
2.8 System to have facility of additional camera installation beyond
Complied
the originally planned capacity.
2.9 The offered system shall have facility to export the desired portion
of clipping (from a desired date/time to another desired date/time) on
Complied
CD or DVD. Viewing of this recording shall be possible on standard PC
using standard software like Windows Media Player etc.
2.10 System should have built-in health diagnostic module to monitor
details like Network link failure, device online/ offline details, Camera
failure, Storage disconnection error, bandwidth loss errors etc. Complied
Further it shall be capable to monitor operation of all services and having
facility to restart automatically when system malfunctions.
2.11 Retrieval: The SCCTV software application should allow retrieval of data
instantaneously or any date/time interval chosen through search
functionality of the application software. In case data is older than 30 days
and available, the retrieval should be possible. The system should also
Complied
allow for backup of specific data on any drives like CD/DVD/Blu-Ray
Recorders or any other device in a format which can be replayed
through a standard PC based software. Log of any such activity should be
maintained by the system which can be audited at a later date.
2.12 Capturing of Driver’s Photographs & Vehicle Registration Number: Complied
(a) It shall have the capability of recording photographs of drivers and
Complied
Registration Number of vehicles.
(b) The system should support Face Recognition (FR) and Automatic Number
Complied
Plate Recognition (ANPR) feature.
2.13 Artificial Intelligence: It shall have image tracking facility. If any object is
found to be stationary for a pre-defined period, the system shall track
the event and alert the operator. This facility may be provided on
select cameras at Entry point, boarding gates, and Arrival area and as
Complied
defined by the tenderer. The system should have the features for
identifying tail- gating, vehicle detection features, unattended baggage

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


identification, queuing analysis, external text insertion feature and
intruder detection.
2.14 It shall provide video file export tool to export the native video format
with all protections (e.g. digital certificate, encryption) for enabling to Complied
play this audio/video on a computer/Laptop.
2.15 The native file format audio/video player shall show the status of
the audio/video authentication as available with the original file
Complied
format, to enable forensic officials to confirm whether audio/video
file has been tampered with.
2.16 The system shall provide tamper-proof video recording. Complied
2.17 Facility for simultaneous reply/playback of multiple cameras should
Complied
be available in VMS application.
3. Design/ functional parameters of SCCTV system
3.1 Camera server software shall run on Commercial-off-the- shelf (COTS)
Servers (Camera Servers & Database Server). Each Camera Server shall be
Complied
able to handle 50 or more cameras. Camera, Database Server & Video
Analytics server will work as failsafe/redundant Server for each other.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


3.2 Camera Server shall offer video stream management, Analytic
stream management and video stream storage management. Recording
Complied
frame rate & resolution in respect of individual channel shall be
Programmable.
3.3 System shall ensure that once recorded, the video cannot be altered;
Complied
ensuring the audit trail is intact for evidential purposes.
3.4 System shall provide sufficient usable storage of all the camera
recordings in common immediate format (CIF) i.e. 4 CIF or better for a
period of continuous THIRTY (30) days on Serial Attached SCSI
(SAS)/SATA at minimum 25 FPS at 720p or 16 FPS at 1920x1080 Complied
resolution or better quality using necessary compression techniques
for all cameras (Extended capacities of Cameras i.e. present capacity
+25%).
3.5 IP Camera shall be used for image capture. Indoor cameras shall be either
with vari-focal lens or withPan/Tilt & Zoom lens as per site requirement. All
Complied
Cameras shall be Day/Night Wide Dynamic Range (WDR) Color
Cameras. All outdoor Cameras should be with IR(Infra-Red) sensors.
3.6 All the indoor cameras & control equipment shall be suitable for
operation from 0° C to 40° C and relative humidity up to 80 %
noncondensing. Cameras & other equipment, meant for outdoor
Complied
installations, shall be suitable to work from (-) 10° C to (+) 50° C
with RH up to 90% non- condensing. This temperature range may be
achieved with or without heater.
3.7 The system shall be provided with servers configured to operate in
Automatic Failover configuration without any need for any manual
Complied
intervention. During change over there shall be no loss of database
transaction.
3.8 System shall provide audio/visual alarm for Error, Failure and Changeover
of main or stand by server, to system administrator or a designated Complied
client terminal automatically.
3.9 System shall allow manual & automatic change over from main server to
Complied
the standby server and vice versa.

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


3.10 All Camera recordings shall have Camera ID & location /area of recording
as well as date/time stamp. Camera ID, Location/Area of recording &
Complied
date/time shall be programmable by the system administrator with
User ID & Password.
3.11 Facility of camera recording in real-time mode (25 FPS) / 15 /12.5/ 10/5
or lower FPS as well as in any desired combination must be available in the Complied
system.
3.12 Facility of edge storage (SD Card to be provided) shall be available in each
camera with the facility to transfer edge storage recording to main storage Complied
i.e. NAS/SAN, after resumption of link in case of network failure.
3.13 Redundancy/Fail-over feature is required i.e. in case of failure of a CAMERA
SERVER, the relevant cameras shall automatically switch over to the Complied
redundant CAMERA SERVER.
3.14 Monitoring at Local control rooms may be restricted to operation of certain
cameras only & system administrator should be able to configure the
Complied
system, accordingly. More than one Local Control rooms may be required in
the proposed system with individual configuration.

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


3.15 Database Server shall keep track of all configurations & events. This shall
help in proper System administration & management of redundancies
Complied
etc. Suitable provision shall be made to keep database backup in same
or another Server.
3.16 All the workstations in LAN should be provided with software to view
and control the cameras, and retrieve the recorded video images from the Complied
CAMERA SERVER/NAS/SAN seamlessly.
Sr. No Description Statement of
Compliance. (
COMPLIANCE: WRITE
“C” and NON-
COMPLIANCE: WRITE
“NC”)
(1) (2) (3)
DETAILED TECHNICAL SPECIFICATIONS & FEATURES (ITEM VISE)
Bidders shall confirm the “Technical Specifications” & Technical features” as mentioned
below.
In addition to the above, the bidder shall ensure the compliance of General
& qualitative requirements for all the BOQ items.
DAY/NIGHT OUTDOOR COLOR DOME PTZ CAMERA: Termination Box , Integrated RJ 45
and power connector should be provided with each camera.
Technical Specifications: Complied
Image Device Sensor:1/2.8” or better CCD/CMOS sensor Complied
Optical zoom (For Indoor Camera) : 40 x or better Complied
Optical zoom (For Outdoor Camera): 40 x or better Complied
Number of Pixels: 1920 x 1080 or better Complied
Resolution: 2MP 1920x1080 or better Complied
Minimum illumination: B/W: 0.0 Lux with IR; Colour: 0.03 Lux or
Complied
better
Pan Travel: 360° Continuous Complied
Tilt Travel: 0 - 90° or better (auto flip). Complied
Manual Tilt Speed: 0.5°/SEC to 90°/SEC or better Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Manual Pan Speed: 0.5°/SEC to 90°/SEC or better Complied
Preset Tilt Speed: 0.5°/SEC to 90°/SEC or better Complied
Compression: H.265 or better Complied
Frame rate and Bit Rate: 25fps with controllable bit rate, frame
Complied
rate and Maximum Bit Rate or better.
Lens: Min 4mm~ Max 240 mm(+/-1mm) Lens or better Complied
Lens Distortion correction: Built in feature required for the better
Complied
clarity.
IR: 500 Meter or better Min 350 Meter IR Built in Remaining 150
Meter IR can be accommodated with External, External IR Shall Complied
be of the same make of camera
Back light compensation: Required Complied
Alarm: 1 Input & 1 output Complied
Audio In: Selectable(Mic in/Line in) Complied
Audio Out: Line Out, Max. output level: 1Vrms Complied
Audio Description: G.711 u-law or G.726 or G.726(ADPCM)
Complied
8KHz or G.711 8KHz, G.726: 16Kbps or 24Kbps or 32Kbps or
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


40Kbps or AAC-LC: 48Kbps at 16KH
Analytics: Defocus detection, Directional detection, Fog
detection, Face detection, Motion detection, Digital auto
tracking, Appear /Disappear, Enter/Exit, Loitering, Tampering,
Complied
Virtual line, Audio detection, Sound classification The VA shall
be Edge based (Built in or Third Party) or In case of server based
additional server shall be considered
Event Triggers: Alarm input, Motion detection, Analytics,
Complied
Network disconnect
Event Action: FTP, HTTP, Email notification, Edge Storage, Alarm
Complied
Output
Edge Storage: Micro SD/SDHC/SDXC with 512GB capacity or
Complied
better
Protocols: IPv4, IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP),
RTCP,RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, FTP, SMTP, ICMP, Complied
IGMP, SNMPv1 / v2c / v3(MIB-2), ARP, DNS, DDNS, QoS.
Security: HTTPS(SSL) Login Authentication, Digest Login
Authentication, IP Address Filtering, User access Log 802.1X, Complied
Authentication (EAP-TLS, EAP-LEAP)
Firmware Upgrade: The firmware upgrade shall be done
though web interface, The firmware shall be available free of Complied
cost.
Interface: RJ 45, 100 Base TX or better Complied
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
Technical Features: Complied
Termination Box, Integrated RJ45 and power Connector Complied
ONVIF(Open Network Video Interface Forum) Complied
Video Stream: Minimum 4 Nos, Individually configurable
Complied
simultaneous stream in H. 265 @ 1920x1080 & 25 fps or better.
Electronic Shutter: 1/10 to 1/12,000 sec or better Complied
Auxiliary inputs & outputs : 1 alarm input, 1 relay Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Iris Control: Auto Complied
White Balance: Auto Complied
Wide Dynamic Range(WDR): 120 dB or better Complied
Camera Housing & Mount: Complied
Housing (Indoor): IP 54 rated or better, shall be of same make as of
Complied
camera.
Housing (Outdoor): IP 66 rated or better, built in Heater and
Blower and shall be of same make as of camera. IK10 certified for Complied
vandal proof rating.
Mount: Standard mounting of same make as of camera shall be
supplied for Surface / Ceiling/pipe/corner/parapet/ pendant with
Complied
wall mount bracket/In Ceiling. Any extension to standard mounting
according to site requirement may be supplied indigenous item.
The camera mounting shall be compact and indoor/outdoor type
as required and capable to hold the total weight of system without Complied
any technical deformity.
DAY/NIGHT VARIFOCAL INDOOR FIXED COLOR DOME CAMERA: Termination Box ,
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Integrated RJ 45 and power connector should be provided with each camera.
Technical Specifications: Complied
Image Device Sensor: 1/2.8” progressive scan CMOS Complied
Maximum resolution: 2MP-1920x1080P or better Complied
ONVIF: Profile S, G & T Complied
Resolution: 1080p HD or better. Complied
Minimum Illumination: Color : 0.005Lux @F/1.6 B/W : 0Lux
Complied
@F/1.6(IR on)
IR Range : 50 meter Complied
Day/Night Method: Auto ICR Complied
Signal-to-Noise Ratio: 50db minimum Complied
Electronic Shutter Range : Auto/Manual, 1/8~1/30000s Complied
Dynamic Range: 120 db minimum Complied
Back light compensation: HLC, WDR(120db) Complied
Analytics: Video Motion Detection, People Counter, Loitering,
Complied
Intrusion, Tampering
Privacy Zone: 4 Configurable windows Complied
Region of interest : 8 Complied
Image Setting : Compression, 3D digital noise reduction(ON/OFF)
Color, brightness, Sharpness, contrast, white balance, exposure Complied
control, backlight compensation/WDR
Defog: Yes Complied
Electrical Complied
Network: RJ-45(10/100Base-T) Complied
Power Input: PoE (802.3af) Class 0/12VDC Complied
Local Storage :Micro SDHC Max 256 GB Complied
Alarm I/O: 1 in & 1out Complied
Mechanical Complied
Lens: 2.8-12mm auto focus motorized optical zoom or better Complied
Video Complied
Video Encoding: H.265 or better Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Video Streams: 3 streams or better Complied
Frame Rate: Main Stream: Up to 2MP @ 25fps.
Sub Stream: up to D1/4CIF(1~25fps) Complied
Third Stream: up to VGA (1~12fps)
Supported Protocols:
IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, IGMP, SMTP, Complied
DHCP, NTP, DNS, DDNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS
Security: User account and password protection, HTTPS, IP Filter,
Digest authentication, TLS1.2 only, Stream encryption, AES- Complied
128/256, SSH/Telnet closed, PCIDSS compliance
Supported Browser: Chrome/Edge Complied
Snapshot: Full Resolution Snapshot Complied
Audio Complied
2- way Full Duplex Complied
Compression Codec: G711A, G711U Complied
Interface Type: Line in & Line Out Complied
User Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Unicast : 10 Users Complied
Multicast: Unlimited Complied
Security Access: Multiple user access levels with password IP
Complied
filtering, HTTPS, IEEE802.1x
Environmental Complied
Operating Temperature: –30°C to 60°C Complied
Operating Humidity: 0% to 90%, non-condensing Complied
Housing: IP67 & IK10 Complied
Certifications: CE, UL/BIS IS 16910 Complied
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
Camera Enclosure/Housing & mount: Complied
Housing (Indoor): IP 54 rated or better, shall be of same make as of
Complied
camera.
Housing (Outdoor): IP 66 rated or better, Built in Heater and
Complied
Blower and shall be of same make as of camera.
Mount: Standard mounting of same make as of camera shall be
supplied for Surface/ Ceiling/pipe/corner/parapet/ pendant with
Complied
wall mount bracket/In Ceiling. Any extension to standard mounting
according to site requirement may be supplied indigenous item.
The camera mounting shall be compact and indoor/outdoor type
as required and capable to hold the total weight of system without Complied
any technical deformity.
DAY/NIGHT VARIFOCAL 5 MP OUTDOOR FIXED IR COLOR BULLET CAMERA: Termination
Box , Integrated RJ 45 and power connector should be provided with each camera.
Technical Specifications: Complied
Image Device Sensor:1/2.8” progressive scan CMOS Complied
Maximum resolution: 5 MP- 2592x1944 Complied
ONVIF: Profile S, G & T Complied
Minimum Illumination (May vary depending on the lens): Color:
0.007 Lux @F/2.0 Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


B/W : 0Lux @F/2.0(IR on)
IR Range: 100 meter or better, among which min 80 Meter IR
should be in built and remaining 20 Meter IR can be
Complied
accommodated with external. External IR Shall be of the same
make of camera.
Day/Night Method: Auto Complied
Signal-to-Noise Ratio: 55db minimum Complied
Electronic Shutter Range : Auto/Manual, 1/8~1/32000s Complied
Dynamic Range: 120 db minimum Complied
Back light compensation: HLC, WDR(120db) Complied
Analytics: Video Motion Detection, People Counter, Loitering,
Complied
Intrusion, Tampering
Privacy Zone: 4 Configurable windows Complied
Region of interest : 8 Complied
Image Setting : Compression, 3D digital noise reduction(ON/OFF)
Colour, brightness, Sharpness, contrast, white balance, exposure Complied
control, backlight compensation/WDR
Defog: Yes Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Electrical Complied
Network: RJ-45(10/100Base-T) Complied
Power Input: PoE(802.3af) Class 0/12VDC Complied
Local Storage :Micro SDHC Max 256GB Complied
Alarm I/O: 1 in & 1out Complied
Mechanical Complied
Lens: 5-45mm auto focus motorized optical zoom or better Complied
Video Complied
Video Encoding: H.265, H.264 Smart Codec bit rate control(CBR
Complied
and VBR)
Video Streams: 3 streams or better Complied
Frame Rate:
Main Stream: 2592 x 1944/2592 x 1520/1920 x 1080/1280 x 720
@ 25fps Complied
Sub Stream: 1920 x 1080/704 x 576//640 x 480/352 x 288 @ 25 fps
Third Stream: 640 x 480/352 x 288/320 x 240 @ 25fps.
Supported Protocols:
IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, IGMP, SMTP, Complied
DHCP, NTP, DNS, DDNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS
Security:
User account and password protection, HTTPS, IP Filter, Digest
Complied
authentication, TLS1.2 only, Stream encryption, AES-128/ 256,
SSH/Telnet closed, PCIDSS compliance
Supported Browser: Chrome/Edge Complied
Snapshot: Full Resolution Snapshot Complied
Audio Complied
2- way Full Duplex Complied
Compression Codec: G711ALAW,G711ULAW Complied
Interface Type: Line in & Line Out Complied
User Complied
Unicast : 10 Users Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Multicast: Unlimited Complied
Security Access: Multiple user access levels with password IP
Complied
filtering, HTTPS,IEEE802.1x
Environmental Complied
Operating Temperature: –30°C to 60°C Complied
Operating Humidity: 0% to 90%, non-condensing Complied
Housing: IP67 & IK10 Complied
Certifications: CE, UL/BIS IS 16910 Complied
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
Camera Enclosure/Housing & mount: Complied
Housing (Outdoor): IP 66 rated, Built in Heater and Blower and
Complied
shall be of same make as of camera
Mount: Standard mounting of same make as of camera shall be
supplied for Surface/Ceiling/pipe/corner/parapet/ pendant with
Complied
wall mount bracket/In Ceiling. Any extension to standard mounting
according to site requirement may be supplied indigenous item.
The camera mounting shall be compact and outdoor type as Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


required and capable to hold total weight of system without any
technical deformity
2MP VERIFOCAL ANPR BULLET CAMERA
Technical Specifications: Complied
Image Device Sensor:1/2.8” progressive scan CMOS Complied
Maximum resolution:2 MP (or better)- 1920x1080P Complied
ONVIF: Profile S, G & T Complied
Resolution: 1080p HD or better. Complied
Minimum Illumination (May vary depending on the lens):
Color : 0.005Lux @F/1.6 Complied
B/W : 0Lux @F/1.6(IR on)
IR Range : 60 meter Complied
Day/Night Method: Auto ICR Complied
Signal-to-Noise Ratio: 50db minimum Complied
Electronic Shutter Range : Auto/Manual, 1/8~1/30000s Complied
Dynamic Range: 120 db minimum Complied
Back light compensation: HLC, WDR(120db) Complied
Analytics: Video Motion Detection, People Counter, Loitering,
Complied
Intrusion, Tampering
Privacy Zone: 4 Configurable windows Complied
Region of interest : 8 Complied
Image Setting : Compression, 3D digital noise reduction(ON/OFF)
Color, brightness, Sharpness, contrast, white balance, exposure Complied
control, backlight compensation/WDR
Defog: Yes Complied
Electrical Complied
Network: RJ-45(10/100Base-T) Complied
Power Input: PoE(802.3af) Class 0/12VDC Complied
Local Storage :Micro SDHC Max 256GB Complied
Alarm I/O: 1 in & 1out Complied
Mechanical Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Lens: 2.8-12mm auto focus motorized optical zoom or better Complied
Video Complied
Video Encoding: H.265 or better Complied
Video Streams: 3 streams or better Complied
Frame Rate:
Main Stream: Up to 2MP @ 25fps.
Complied
Sub Stream: up to D1/4CIF(1~25fps)
Third Stream: up to VGA (1~12fps)
Supported Protocols:
IPv4, IPv6, TCP/IP, HTTP, HTTPS, UPnP, RTSP/RTP/RTCP, IGMP, SMTP, Complied
DHCP, NTP, DNS, DDNS, QoS, SNMP, 802.1X, UDP, ICMP, ARP, TLS
Security:
User account and password protection, HTTPS, IP Filter, Digest
Complied
authentication, TLS1.2 only, Stream encryption, AES-128/256,
SSH/Telnet closed, PCIDSS compliance
Supported Browser: Chrome/Edge Complied
Snapshot: Full Resolution Snapshot Complied
Audio Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


2- way Full Duplex Complied
Compression Codec: G711A, G711U Complied
Interface Type: Line in & Line Out Complied
User Complied
Unicast : 10 Users Complied
Multicast: Unlimited Complied
Security Access: Multiple user access levels with password IP
Complied
filtering, HTTPS, IEEE802.1x
Environmental Complied
Operating Temperature: –30°C to 60°C Complied
Operating Humidity: 0% to 90%, non-condensing Complied
Housing: IP67 & IK10 Complied
Certifications: CE, UL/BIS IS 16910 Complied
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
Camera Housing & Mount: Complied
Housing (Outdoor): IP 66 rated or better, built in Heater and
Blower and shall be of same make as of camera. IK10 certified for Complied
vandal proof rating.
Mount: Standard mounting of same make as of camera shall be
supplied for Surface / Ceiling/pipe/corner/parapet/ pendant with
Complied
wall mount bracket/In Ceiling. Any extension to standard mounting
according to site requirement may be supplied indigenous item.
The camera mounting shall be compact and indoor/outdoor type
as required and capable to hold the total weight of system without Complied
any technical deformity.
4.5 LAYER 3 CORE SWITCH: FULLY POPULATED AND CONFIGURED AS 1:1 REDUNDANT CORE
SWITCH
24 nos. of fiber ports, 10 Gbps SM with 24 nos of required LX
Complied
modules.
TECHNICAL SPECIFICATIONS: Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


HARDWARE AND INTERFACE: Complied
Proposed switch should have 24 ports of 1G/10G which can
accommodate 1G copper transceivers, 1G fiber transceivers & 10G
fiber transceivers
Switch should 1RU with 24 ports 24* 10GE SFP+ ports & 4*100GE Complied
QSFP28 ports Layer 3 10GbE Managed Switch with fully populated
with Required SFP+/QSFP28 Module and Two AC hot-swappable
power modules for 1+1 redundancy and load sharing.
Should have RJ-45 console ports for out-of-band CLI management. Complied
Switch should Support and preloaded with fan trays for
Complied
temperature management.
Should support One 10/100/1000BASE-T RJ-45 Ethernet for out-of-
Complied
band IP management.
Should support One USB Port for easy management for images and
configuration files, that can be copied to and from the NVRAM of Complied
the Switch.
Two Switches should be configured in active-active mode for
Complied
redundancy.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Switching Capacity should be a min of 480 Gbps & with a min
packet Forwarding rate of 357 Mbps. The switch should be wire Complied
speed.
Switch should support Physical Stacking up to 8 units per stack.
Stacking bandwidth should be at least 80Gbps per switch. Stacking
ports should be separate and in addition to the above mentioned Complied
ports. Necessary cables/interfaces should be provided with each
switch for stacking from day-1.
PERFORMANCE Complied
Switching Capacity should be 1.280 Tbps & Packet Forwarding rate
Complied
should be 952 Mbps.
MAC Address Table should be Up to 32K entries or More. Complied
It shall have support for Detection of Unidirectional links and to
Complied
disable them to avoid problems such as spanning tree loops.
Packet Buffer Memory 4 MB Complied
Should support MAC based VLAN Complied
Should support GVRP or equivalent, Private VLAN or equivalent,
Complied
Subnet VLAN or equivalent, Voice VLAN and QinQ.
It shall have support for Detection of Unidirectional links and to
Complied
disable them to avoid problems such as spanning tree loops
It shall support RADIUS/TACACS+ authentication to enable
centralized control of the switch and restrict unauthorized users Complied
from altering the configuration.
BPDU Attack Protection, ARP protection, IP Source Guard, Dynamic
Complied
ARP Inspection and DOS Attack Prevention
The Switch shall have the intelligence to detect the loop occurring
Complied
from the unmanaged network segment .
IEEE STANDARDS Complied
Should have IEEE Standards of Ethernet: IEEE 802.1D, 802.1s,
802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q, 802.3, 802.3ae, Complied
802.3u, 802.3ab, 802.3z.
SECURITY Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Switch should support Port isolation, Port security, and “IP-MAC-
port” binding, DHCP Snooping, IP source guard, IEEE 802.1x,
Radius and TACACS+, DDoS, TCP’s SYN Flood, UDP Flood, etc. Complied
Broadcast/multicast/unknown unicast storm-control, Supports
encryption MD5, etc.
Switch Should Support Flow Control, Spanning Tree Protocol,
802.1D STP, 802.1w RSTP, 802.1s MSTP, Root Guard, Loop Guard, Complied
Jumbo Frame
Switch Should Support 802.1AX Link Aggregation, 8 groups per
device, 8 ports per group, ERPS (Ethernet Ring Protection Complied
Switching)
Switch Should Support Port mirroring Supports one-to-one, many-
to-one, Supports mirroring for Tx/Rx/both, Supports 4 mirroring
Complied
groups, VLAN mirroring, L2 protocol tunnelling, Loopback
Detection (LBD)
ROUTING PROTOCOLS Complied
Should support Static Route, Default Route, OSPF for IPv4 and IPv6, Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


RIPv1/v2, RIPng, and Policy-based Route (PBR) for IPv4 and IPv6,
support for BGPv4, VRRPv3, IPv6 Neighbour Discovery (ND)
Should support Static, ISATAP and 6to4 IPv6 Tunnelling. Complied
Should support IGMPv1/v2/v3 for Layer 3 Multicast, L3
Complied
multicasting features such as IGMP, MLD, PIM-DM, SM.
Should support 802.1p Quality of Service with 8 queues per port Complied
Should support Queue Handling with Strict Priority Queue,
Weighted Round Robin, Deficit Round Robin (DRR), SPQ + WRR and Complied
WFQ.
Should support QoS based on 802.1p Priority Queues, MAC
Complied
address, IP address, DSCP, VLAN, TCP/UDP port, Switch port
Should support Ingress and Egress ACL, Time-based ACL Complied
Should support Access Control List based on 802.1p priority, 32K
Complied
MAC address, VLAN, TCP/UDP port number, DSCP, IP address
Should support 802.3ah Ethernet link OAM and 802.1ag
Complied
Connectivity Fault Management (CFM) and Y.1731 OAM.
MANAGEMENT Complied
Shall have Ethernet management port for GUI and console
Complied
management for CLI support.
Switch should support AAA using RADIUS/TACACS+ Complied
Switch shall have SSHv2, SNMPv2c, SNMPv3 and NTPv3/NTPv4. Complied
POWER CHARACTERISTICS Complied
AC Voltage: 220 to 240V (+/-10% auto ranging) Complied
Frequency: 50 +/- 1 Hz Complied
WARRANTY Complied
3 years warranty should be included with the switches Complied
ACCESSORIES Complied
Switch should be supplied with the all necessary hardware
accessories like Power cord, Rack-mount bracket, Installation
Complied
Guide, etc. and necessary software image file to fulfill all above
mention feature set from day 1.

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


4.6 LAYER 2 POE SWITCH
L2 Switch (24 Nos. of 10/100/1000 Mbps PoE Copper Ports and 4
Complied
Nos. of 10Gbps SFP ports fully populated with required modules)
TECHNICAL SPECIFICATIONS: Complied
PORT DENSITY/HARDWARE Complied
Switch with at least 24 X 10/100/1000 RJ-45 PoE+ Gigabit Ethernet
Complied
Ports and 4 x 10G SFP+ Ports.
Switching capacity should be 128 Gbps or higher or non-blocking
architecture.
Complied
POE budget of 740 watts for utilizing all ports on 802.3at
standard(30Watts)
Switch packet forwarding rate should be 95 Mbps or higher or non-
Complied
blocking architecture.
Certification: CE, FCC, BSMI, RoHS and cUL. Complied
Operating temperature should be -5 degree Celsius to +50 degree
Complied
Celsius.
Power input should be 100 to 240 VAC, 50/60 Hz, internal power
Complied
supply. Power Saving (Green).
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Switch should be standard 19 inch 1U rack mountable. Complied
Support for the Energy Efficient Ethernet (IEEE 802.3az) standard. Complied
PERFORMANCE Complied
Switch MAC table should be at least 16K or higher. Complied
Shall have minimum 250 active VLANs. Complied
Switching capacity should be 128Gbps or higher or non-blocking
Complied
architecture.
Switch packet forwarding rate should be 95.24 Mpps or higher or
Complied
nonblocking architecture.
Should support Head of Line blocking prevention for lower latency
Complied
and better performance.
Support Jumbo Frame up to 12K Bytes or higher. Complied
Should support IGMP Snooping, Able to create 250 or more IGMP
groups and require support for IGMP Snooping Fast Leave, IGMP Complied
Snooping Querier
Should support MLD Snooping, Able to create 250 or more MLD
groups, Per VLAN MLD Snooping and require support for MLD Complied
Snooping Fast Leave.
Link Aggregation LACP 802.3ad: Minimum 8 groups per device and
Complied
8 ports per group
Port Mirroring : One-to-One / Many-to-One Complied
Should support Loopback detection (LBD) to detect the loop
Complied
created by a specific port.
Should support Multicast Filtering to filters or forward all
Complied
unregistered groups.
Switch should support IEEE 802.1Q VLAN tagging for Ethernet
Complied
frames.
Different type of VLAN like Port based, Auto Surveillance, Auto
Complied
Voice, Asymmetric Vlan etc. should be available for configuration.
Switch should support QoS (quality of service) IEEE 802.1P for
Complied
traffic prioritization. It should support 8 queues per port.
Different type of QoS priority like Strict Priority Queue and

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Complied
Weighted Round Robin.
Port based ingress / egress rate limit function should be available
Complied
with limit in increments as low as 16 Kbps
Switch should support Neighbour Discovery (ND) protocol for IPv6. Complied
Switch should support to create at least 4 IP interface Complied
Should support default routing and static routing with minimum
100 IPv4 static route entries and minimum 50 IPv6 static route Complied
entries.
Support at least 700 rules shared by IPv4, MAC, and IPv6 & Each
Complied
rule can only be associated with a single port.
Should have broadcast, multicast, and unicast storm control to
prevent faulty end stations from degrading overall systems Complied
performance
Support Traffic Segmentation to restricted traffic flow from a single
Complied
or group of ports, to another group of ports.
Should have SSH and SSL for IPv4 and IPv6 Complied
Require prevention of DoS attacks, which include Land, Blat, TCP Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Null Scan, TCP Xmas Scan and TCP SYNFIN.
Switch should able to create a binding table for IP + MAC + Port to
prevent a malicious user from spoofing or to restrict the Complied
unauthorized users.
Should have option to check the status of copper cables using the
Complied
cable diagnostics time domain reflectometer (TDR).
Should support Link Layer Discovery Protocol (LLDP) and LLDP-
Complied
MED.
IEEE STANDARDS Complied
Should have IEEE Standards of Ethernet: IEEE 802.1D, 802.1s,
802.1w, 802.1x, 802.3ad, 802.3x, 802.1p, 802.1Q, 802.3, 802.3u, Complied
802.3ab, 802.3z, 802.3af. 802.3at.
SECURITY Complied
Switch should support port security, Complied
Switch Should Support Access Control List based on (ACL's) 802.1p
priority, VLAN, MAC address, Ether type, IP address, DSCP, Protocol
Complied
type, TCP/UDP port number, IPv6 Traffic Class, Max. ACL Profiles /
Rules: 50 / 768
Should support port security to secures the access port based on
Complied
MAC address.
Should support ARP spoofing prevention Complied
Should support DHCP snooping and DHCP server screening. Complied
Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning
Complied
Tree Protocol.
Should support Spanning tree Root restriction Complied
Switch shall have port mirroring Complied
MANAGEMENT Complied
Able to manage trough Web-GUI, CLI, Telnet & SNMP Complied
Should support 802.1X RADIUS and local server database
Complied
authentication.
Should support SNMP v1, v2c, v3 and SNMP Traps and Remote
Complied
Monitoring (RMON).

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Should have SNTP/NTP protocol for time synchronization. Complied
Should have dual Image support to reduced down time for the
Complied
switches
Switch should support dynamic host configuration protocol (DHCP)
auto configuration of multiple switches through a boot server Complied
eases switch deployment.
Switch should be supplied with the all necessary components like
Power cord, Rack-mount bracket, Installation Guide, etc. and
Complied
necessary software image file to fulfil all above mention feature set
from day 1.
OEM Should be International certification for the ISO 45001 Health
and Safety Management System, Information Security
Management System: ISO 27001, ISO 9001 Quality Management Complied
System, ISO 14001 Environmental Management System, and ISO
14064-1 Greenhouse Gas Inventory Standards.
WARRANTY Complied
3 years warranty should be included with the switches Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


ACCESSORIES Complied
Switch should be supplied with the all necessary hardware
accessories like Power cord, Rack-mount bracket, Installation
Complied
Guide, etc. and necessary software image file to fulfil all above
mention feature set from day 1.
4.7 LAYER 2 INDUSTRIAL GRADE SWITCH

TECHNICAL SPECIFICATIONS:
SWITCH HARDWARE
Switch with at least 4 X 10/100/1000 RJ-45 PoE+ Gigabit Ethernet
Complied
Ports and 2 x 1G SFP Ports.
Switching capacity should be 12 Gbps or higher or non-blocking
Complied
architecture.
Flexibility in power supply of AC/DC Complied
Support for redundant power supply is must, should be quoted
Complied
with 2 power supplies from day1.
POE budget of 120 watts for utilizing all ports on 802.3at
Complied
standard(30Watts)
Switch packet forwarding rate should be 8 Mbps or higher or non-
Complied
blocking architecture.
Switch should support ACL for L2-L4 types. Complied
Switch should be standard 19 inch 1U rack mountable. Complied
SOFTWARE FUNCTIONALITY Complied
Proposed switch shall support min 16K MAC addresses Complied
Support for the Energy Efficient Ethernet (IEEE 802.3az) standard. Complied
Proposed switch shall be stackable with support for at least 8
Complied
switches in a stack for future ease of management
Should support Head of Line blocking prevention for lower latency
Complied
and better performance.
Support Jumbo Frame up to 9K Bytes or higher Complied
Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning
Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Tree Protocol.
Should support Spanning Tree Root restriction Complied
Should support Loopback detection (LBD) to detect the loop
Complied
created by a specific port.
Switch should support IEEE 802.1Q VLAN tagging for Ethernet
Complied
frames.
Different type of VLAN like Port based, Auto Surveillance, Auto
Complied
Voice, Asymmetric VLAN etc. should be available for configuration.
Switch should support QoS (quality of service) IEEE 802.1P for
Complied
traffic prioritization. It should support 8 queues per port.
Different type of QoS priority like Strict Priority Queue and
Complied
Weighted Round Robin.
Should support default routing and static routing with minimum
200 IPv4 static route entries and minimum 50 IPv6 static route Complied
entries
Support at least ACLs configurable by IPv4, MAC, and IPv6 Complied
Should support port security to secures the access port based on
Complied
MAC address.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


should have broadcast, multicast, and unicast storm control to
prevents faulty end stations from degrading overall systems Complied
performance.
Should support Link Layer Discovery Protocol (LLDP) and LLDP-
Complied
MED.
Should have SSH and SSL for IPv4 and IPv6. Complied
Should support 802.1X port based authentication. Complied
Should support ARP inspection Complied
Should support DHCP snooping and DHCP relay. Complied
Switch should able to create a binding table for IP + MAC + Port to
prevents a malicious user from spoofing or to restrict the Complied
unauthorized users.
Should support 802.1X RADIUS/TACACS+ Complied
Should have SNTP/NTP protocol for time synchronization. Complied
Switch should be IPv6 Ready from day 1 Complied
MULTICASTING Complied
Should have IGMP snooping v1, 2 & 3 supporting min 1K multicast
Complied
groups
MLD Snooping v1 & v2 Complied
Should have console port for administration & management
Complied
through CLI and web based GUI for easy management
Diagnostics : Loopback detection and Unicast / Broadcast &
Multicast Storm Control, LLDP / LLDP-MED, Port Mirroring, SNTP, Complied
SNMP Trap
VLAN : IEEE 802.1Q VLAN Complied
IEEE STANDARDS Complied
IEEE 802.3 10BASE-T Ethernet, IEEE 802.3u 100BASE-TX Fast
Ethernet, IEEE 802.3x Flow Control, IEEE 802.3ab 1000BASE-T
Gigabit Ethernet, IEEE 802.3af/at compliance (for PoE ports), IEEE
802.3az Energy Efficient Ethernet, IEEE 802.3z 1000BASE-X 1 Gbps
Complied
over fiber optic (MSA compliant SFP supported), IEEE 802.3ad –
LACP, IEEE 802.1d - Spanning Tree, IEEE 802.1p - Class of Service,

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


IEEE 802.1Q - VLAN Tag, 802.1x Radius/TACACS+ Authentication,
DHCP Client
Port Security to secure the access to a port based on the MAC
address of a user's device. The aging feature to remove the MAC
Complied
address from the switch after a specific time to allow another
device to connect to the same port.
Multilevel security on console access to prevent unauthorized
Complied
users from altering the switch configuration.
Switch should support ring protection protocol STP, RSTP, MSTP,
Complied
ERPS/ Ring Protection
Port-based and 802.1Q tag-based VLANs, MAC-based VLAN,
Complied
Private VLAN, Voice VLAN, QinQ, GVRP
SECURITY Complied
IEEE 802.1x Port Access Control, ACL, TACACS+ Authentication,
Complied
SSH, SSLv2
IEEE802.1X: RADIUS authentication, authorization and accounting,
Complied
MD5 hash, Guest VLAN, single/multiple host mode and
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


single/multiple sessions, Supports IGMP-RADIUS based 802.1X,
Dynamic VLAN assignment
Features of DHCP Server, DHCP (including option 82), DHCP Relay|
Complied
NTP or equivalent, TELNET/ SSH
Duplicate address detection (DAD), Sflow Complied
Should support Static routes for IPv4 and IPv6, MVR Complied
LOCAL INDICATION Complied
Status LEDs for Power, PoE status, link activity etc. Complied
POWER SUPPLY: Complied
Redundant Input DC power supply from 48 to 57 VDC Complied
HOUSING : Rugged IP30 protection Complied
OPERATING TEMPERATURE: -40°C~ 75°C Complied
Switch should Certified NEMA-TS2, Shock-Drop-Vibration Test, UL,
Complied
FCC and CE (All certificates should enclosed with bid)
Switch should be supplied with the all necessary hardware
accessories like Power cord, Rack-mount bracket, Installation
Complied
Guide, etc. and necessary software image file to fulfil all above
mention feature set from day 1.
WARRANTY Complied
3 years warranty should be included with the switches Complied
ACCESSORIES Complied
Switch should be supplied with the all necessary hardware
accessories like Power cord, Rack-mount bracket, Installation
Complied
Guide, etc. and necessary software image file to fulfil all above
mention feature set from day 1.
4.8 1 GIGABIT SFP MODULE
Support DATA rate : 1G Complied
Wavelength : 850nm Complied
Support protocol IEEE802.3z (1G). Complied
Should support 500 m optical distance Complied
Should have LC type connector Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


operating Temperature of the SFP Should be minimum 0 to 70 °C Complied
Should have Feature Digital Diagnostics Monitoring (DDM)/ Digital
Complied
Optical Monitoring (DOM)
Should RoHS Compliant Complied
Supports Multimode fibre Complied
hot-swappable Complied
Covers three years warranty. Complied
4.9 NETWORK ATTACHED STORAGE (NAS)
SAS/SATA Disk (in RAID 6 Configuration), suitable power socket, DC
Complied
power converters, connectors, cables & required accessories etc.
TECHNICAL SPECIFICATIONS: Complied
NAS Storage System with RAID 6 configuration shall be used to
record video streams based on the configuration assigned by Complied
administrator.
Workstations & Servers within the LAN should be able to access
Complied
the recorded video streams.
The Storage device shall support simultaneous play back and
Complied
recording at full duplex operation.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


It shall provide a high quality recording storage and play back of
images. It shall support integration with LAN to provide Centralized
Management and shall operate on Windows/Linux/Unix/OEM OS.
Complied
Support of user management for security level control and
authentication required. These Storage device shall have the
following features and specifications:
Controller: Dual Active-Active Controllers in failover mode with no
Complied
single point of failure.
Onboard Cache: 16 GB minimum per Controller (Mirrored) Complied
Storage Disk: 10K / 7.2K rpm SAS/NLSAS/SATA disk for minimum
Complied
storage of 30 days
Host Interface: At least four Gigabit Ethernet (IP) ports and four FC
Complied
port.
HDD type support (Any one): SAS/SSD/NLSAS/ SATA Complied
Inbuilt RAID Support: RAID-Double Disk failure support/ RAID-6 or
Complied
higher.
Network Transport Protocols: TCP/IP Complied
Server/ Storage should support Protocol (As per solution) (Any
one): CIFS/ NFS/ iSCSI/ FCP/ HTTP/HTTPS/ FTP/ NTP/ SNMP/ SMTP/ Complied
DHCP and DNS.
Power Supply : Hot pluggable Redundant Power Supply Complied
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
Operating System (OS) with latest version: Built-in Storage OEM
Complied
OS, Compatible with MS Windows/Linux/Unix.
Storage Management Software: Inbuilt GUI/CLI/ Web Based
Complied
administration management software
Mounting arrangement: Rack mountable. Complied
Scalability: The offered storage shall be scalable to add additional
Complied
50% usable capacity at site within the same storage.
The following information should be provided by the NAS supplier
Complied
against each configuration:

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Parameters Complied
Drive Type Complied
Drive speed Complied
Dive size Complied
RAID group used to configure Complied
Usable capacity( Data+ Parity+ Complied
spares) along with total Disks
supported by NAS
Balance disk space to configure Complied
additional 50% usable capacity.
Storage System should be provided with: Complied
No other upgrades should be required for desired scalability except
Complied
for disk Arrays enclosures and Disk drives as required.
Once data is stored in Storage, no client/operator should be able to
Complied
delete or modify data.
FC Switches, if required, as part of the solution should be provided
Complied
as per system design without any extra cost to AAI.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


If any additional appliance required to provide the NAS capability,
then the solution should be in high availability mode and the cache Complied
of the same should be extra with no cost to AAI.
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
4.10 55”LED DISPLAY FOR VIDEO WALL complete with wall/ceiling/floor
mounting arrangement
Technical Specifications: for 55" LED Display Complied
Display monitor shall be provided with all accessories and cabinet
suitable for industrial/professional 24x7 operation with
Complied
arrangement for Wall or corner Mount installation with provision
for Swivel movement.
Screen Size: 55” (diagonal) or higher Complied
Monitor Type: Industrial/ Professional suitable for 24x7 operation. Complied
Back Light: LED Complied
Aspect Ratio: 16:9 Complied
Resolution: Full HD, 1920 X 1080 pixels or better Complied
Brightness: 450 cd/m2(nit) or better Complied
Contrast Ratio: 2400:1 without IPS/1100:1 along with IPS or better. Complied
Viewing angle: 178: Complied
System: PAL Complied
Operating Voltage: Suitable for single phase AC supply 180-230 V,
Complied
50 Hz
Video Input Ports: Digital Ports: HDMI/DVI-D ; PC-VGA in: 1xD-Sub ,
Complied
Cable shall be provided as per site requirement.
Mounting: complete with wall/ceiling/floor mounting
Complied
arrangement.
Bureau of Indian standard (BIS) certified. Complied
Technical Specifications for 2X2 (4 Panels) Video wall. Complied
Screen Size :55” Complied
Panel Technology : IPS Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Backlight Type :DLED Complied
Brightness (typical) : 500 cd/m2 Complied
Native Resolution : 1920x1080 Complied
Contrast Ratio (typical) : 1100 : 1 (TBD) Complied
Dynamic Contrast Ratio : 500000 : 1 Complied
Life Time (typical) : 100000 hrs Complied
Response Time (typical) : 8 ms Complied
Active Area (H x V) : 1212.2(H) x 683(V) mm Complied
Pixel Pitch (H x V) : 0.630 x 0.630 Complied
Viewing Angle : 178° Vert., 178° Hor. (89U/89D/89L/89R) @ CR>10 Complied
Color Value : 1.06 B (10-bit) Complied
Screen Treatment : 3H Complied
Haze Level : 28% Complied
Refresh Rate : 60 Hz Complied
Front Type : Extra narrow bezel Complied
Orientation : Horizontal / Vertical Complied
Operation Hours : 24/7 Panel Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Area of Usage : Indoor Complied
RGB Input : VGA(DE-15F) Complied
RGB Output : N/A Complied
Video Input : 2xHDMI2.0, 2xUSB2.0, USB2.0(Internal) Complied
Video Output : HDMI2.0 Complied
Audio Input : Line In L/R Complied
Audio Output : Headphone, Optic SPDIF Complied
External Control : RS232(DE-9F), Ethernet(RJ45), Service(RJ12) Complied
External Sensor : RJ12 Complied
Operating Temperature : +50°C / 0°C Complied
Operating Humidity : 90% Complied
Power Supply : 110 VAC - 240 VAC Complied
Typical : 138 W Complied
Maximum : 260 W Complied
Deep Standby : 0.5W Complied
Size : 1212.2 (W) x 105.4 (D) x 683 (H) mm Complied
Shipping Size : 1366 (W) x 277 (D) x 836 (H) mm Complied
Weight (kg) : 27 kg Complied
Shipping Weight : 37 Kg Complied
Vesa Mounting Size : 400 x 600 Complied
Bezel Width : B2B: 1.8 mm / A2A: 2.6mm Complied
Main Features : Video wall setup with Daisy-Chain, Open Content
Management Support, Manual Fine Color Calibration, Video wall Complied
Scheduler, Auto-Launch, Auto-switch on Failover, Panel Lock
Speaker: N/A Complied
Standard : QSG, IB, Power Cord, Remote Control, RC Battery,
Complied
Display Port Cable, USB to Rs232 Converter
Mounting Kit : Standard Complied
Safety : Yes Complied
EMC : Yes Complied
CE : Yes Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


WORKSTATION - FOR VIDEO WALL Complied
Technical Specifications: Complied
CPU: Minimum 9th Generation Core i9-9940X Intel Processor
Complied
operating at 2.6 GHz or more with 8 MB Cache or higher.
Memory: 32 GB or higher. Complied
Hard Drives: 500GB (SATA/ SAS) or more. Complied
Video Card: Dual NVIDIA GeForce RTX 2080 or better, dual port
Graphics card to support 2X2 (4 panel of 55” or higher) Video wall Complied
for viewing better quality of live video /playback.
Motherboard: Original OEM. Complied
RAID: supported. Complied
Keyboard: Variable speed Joystick controller with LCD/LED display
(for programming and to control the speed dome for PAN / TILT / Complied
Zoom) or USB supported standard keyboard.
Mouse: Optical Mouse with scroll. Complied
Network Adapter (NIC): 02 numbers of Gigabit Ethernet ports
Complied
10/100/1000Mbps).

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Sound Card: in-built Complied
DVD writer: DVD RW/ Blu Ray combo internal/external Complied
Display Dual support: 1) Monitor, 19" or higher LED monitor with
02 port HDMI connectivity.
Complied
2) Video Wall support 2x2 (4 panel of 55” or higher) with HDMI
connectivity.
USB 3.0 or higher: 2 nos. at front panel. Complied
Operating System: Licensed MS Windows 64 bit or Linux (Latest
Complied
professional version)
Anti-Virus Software: Anti-Virus Software compatible with
Windows/ Linux along with update subscription valid till warranty Complied
and CAMC period.
Client VMS application software along with viewing License to be
Complied
provided.
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
4.11 65”LED DISPLAY complete with wall/ceiling/floor mounting
Complied
arrangement
Technical Specifications: for 65" LED Display Complied
Display monitor shall be provided with all accessories and cabinet
suitable for industrial/professional 24x7 operation with
Complied
arrangement for Wall or corner Mount installation with provision
for Swivel movement.
Screen Size: 65” (diagonal) or higher Complied
Monitor Type: Industrial/ Professional suitable for 24x7 operation. Complied
Back Light: LED Complied
Aspect Ratio: 16:9 Complied
Resolution: Full HD, 1920 X 1080 pixels or better Complied
Brightness: Minimum 500 cd/m2(nit) or better Complied
Contrast Ratio: 2400:1 without IPS/1100:1 along with IPS or better. Complied
Viewing angle: 178: Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


System: PAL Complied
Operating Voltage: Suitable for single phase AC supply 180-230 V,
Complied
50 Hz
Video Input Ports: Digital Ports: HDMI/DVI-D ; PC-VGA in: 1xD-Sub ,
Complied
Cable shall be provided as per site requirement.
Mounting: complete with wall/ceiling/floor mounting
Complied
arrangement.
Bureau of Indian standard (BIS) certified. Complied
4.12 WORK STATION Operating system and Anti-virus with Keyboard
Complied
Optical Scroll Mouse and all accessories etc
Technical Specifications: Complied
CPU: Minimum 9th Generation Core i9-9940x Intel Processor
Complied
operating at 2.6 GHz or more with 8 MB Cache or higher.
Memory: 16 GB DDR 4 or higher Complied
Hard Drives: 512GB (SATA/ SAS) or more. Complied
Video Card: Dual NVIDIA GeForce RTX 2080 or better, dual port
Graphics card to support 2X2 (4 panel of 55” or higher) Video wall Complied
for viewing better quality of live video /playback.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Motherboard: Original OEM Complied
RAID: supported. Complied
Keyboard: Variable speed Joystick controller with LCD/LED display
(for programming and to control the speed dome for PAN / TILT / Complied
Zoom) or USB supported standard keyboard.
Mouse: Optical Mouse with scroll. Complied
Network Adapter (NIC): 02 numbers of Gigabit Ethernet ports
Complied
(10/100/1000Mbps).
Sound Card: in-built Complied
DVD writer: DVD RW/ Blu Ray combo internal/external. Complied
Display Dual support: 1) Monitor, 65" or higher LED monitor with
HDMI connectivity.
Complied
2) Video Wall support 2x2 (4 panel of 55” or higher) with HDMI
connectivity.
USB 3.0 or higher: 2 nos. at front panel. Complied
Operating System: Licensed MS Windows or Linux (Latest
Complied
professional version).
Anti-Virus Software: Anti-Virus Software compatible with
Windows/ Linux along with update subscription valid till warranty Complied
and CAMC period.
Client VMS application software along with viewing License to be
Complied
provided.
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
4.13 LAPTOP SPECIFICATION Complied
Processor Make : Intel Core i7, 2.4GHz 12 generation Complied
SSD Drive Size : 512 GB Complied
RAM Size (GB) : 16 GB or higher Complied
RAM Expandability upto (GB) : 32 GB Complied
Type of RAM : DDR 4 Complied
Operating System : Licensed Windows 11 Professional 64 bit with
Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


restore/ recovery CD or higher
Display Size (Inch) : 15.6-inch FHD or higher Complied
Display resolution (Pixels) : 1920 x 1080 or higher Complied
Chipset : Intel original Complied
Graphics Type : Integrated /2 GB or higher Complied
Optical Drive Type : DVD drive (inbuilt or external )_ Complied
Batteries : Lithium Polymer batteries with 3 years warranty or
Complied
more
USB Port (Number) : 3 or more Complied
Battery back-up : 8 hr or more Complied
Audio : Integrated Stereo Complied
Wi-fi Connectivity : Yes dual band Complied
Bluetooth Connectivity : 5.0 Complied
HDMI Port: 1 Complied
LAN Port (RJ45) : 10/100/1000 Mbps (inbuilt or external ) Complied
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
4.14 CONSOLE FOR CONTROL ROOM Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


4.14.1 Console shall be supplied with 02 no. of rotating pushback chairs
Complied
standard make as per following features:
The console shall be built to withstand life span of 06 years on
Complied
normal use, wear and tear.
The structure of the Console shall be of standard make and should
Complied
have following component and design:
Structure shall be made of Extruded Vertical & Horizontal
Aluminium profiles (powder coated finish) fastened together with
Complied
heavy-duty MS joineries. Having all SS Bolts and nickel-plated
hardware.
Work-surface shall be minimum 25 mm thick MDF with High
Pressure laminate. Front edge Nosing shall be injection moulded Complied
on the profiled wooden core. Depth shall be 50 – 60mm.
Desk shall house CPU on Slide out metallic CPU trays. Complied
Monitors shall be mounted on aluminium die casted arms. Monitor
arm shall be able to mount monitors complying VESA (Video
Complied
Equipment Standards Association) standards 75 x 75, 100 x 100,
200 x 100 & 200x200 mm.
CPU cabinet front, back shutters shall be of 18 mm Laminated MDF
Board with premium finish. Side leg shall be of 25mm of the same Complied
finish.
Rear shutters shall have provision of Airflow opening for cooling
Complied
and heat dissipation effect.
Electricals: Each console shall be equipped with individual power
Complied
distribution unit.
Final drawings and design will be approved by CNS In charge at the
Complied
time of execution.
4.14.2 Fabrication, supply and installation of Console for Control room
shall be done by the bidder firm and shall have the following Complied
provisions:
Provision to suitably install Workstations. Complied
Keyboard, Mouse shall be installed on Console for camera

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Complied
monitoring and PTZ control.
Lockable compartment for keyboard shall be provided. Complied
Space for proper termination of cables shall be provided. Complied
4.15 RACK MOUNTABLE VMS (VIDEO MANAGEMENT ) Server Complied
The VMS OEM can also provide purpose build appliances for
server compute and storage with DAS support. The appliance
Complied
should provide higher throughput compared to COTS servers for
optimization of cost.
CPU: Intel® Xeon-Silver 4310 2.1GHz 12-core or Better Complied
Memory: 32 GB RAM or Better Complied
Chassis type: Rack mountable Complied
Hard Drives: 2 X 960GB SSD (RAID1) with “Keep Your Hard Drive”
Complied
For OS & Application. 2 *960Gb SATA 6G or better for storage
Power supply :Hot Pluggable Redundant Power Supply Complied
Fans. Redundant FANS. Complied
TECHNICAL FEATURES: Complied
Network Adapter (NIC): 2x 1GbE RJ45. Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Keyboard: USB Keyboard Complied
Mouse: Optical Mouse with scroll Complied
Operating System: Windows Server IoT 2019 or latest
Complied
equivalent.
Operating System: The appliance must have a turnkey solution
with Video Management Software pre- installed and only Complied
camera and other licenses to be activated at site.
The appliance should be extensively tested and hardened for
Complied
security to prevent malicious attack
The solution must have machine-learning based antivirus native
Complied
to the solution.
The solution must have built in maintenance tool developed by
Complied
the manufacturer of the video management.
Warranty: 3 years NBD support Complied
4.16 RACK MOUNTABLE ANPR (AUTOMATIC NUMBER PLATE READER)
Complied
SERVER
Technical Specifications: Complied
CPU: Minimum Processor of 12 Core or higher Intel/AMD CPU
operating at 3.6 GHz or more with a minimum of 11 MB L3 cache Complied
or higher
Memory: 32 GB DDR RAM or better Complied
Chassis type: Rack mountable Complied
Hard Drives: SAS 7200K rpm or higher hot swappable Hard Disk
Complied
inRAID 5 or 6 configuration having usable space of 1 TB or more.
Dedicated Graphic Card: 12GB Graphic Card or higher- Complied
Network ports:
Dual integrated 10/100/1000Mbps ports with required modules, Complied
cables, connectors, accessories, etc.
Keyboard: USB Keyboard. Complied
Mouse: Optical Mouse with scroll. Complied
Operating System: Licensed MS Windows Server or Linux (Latest
Complied
version)

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Anti-Virus Software compatible with Windows/ Linux along with
Complied
update subscription valid till warranty and AMC period.
Fans: Redundant Fans Complied
The appliance should be extensively tested and hardened for
Complied
security to prevent malicious attack
The solution must have machine-learning based antivirus native
Complied
to the solution.
The solution must have built in maintenance tool developed by
Complied
the manufacturer of the video management.
Network Adapter (NIC): 2x 1GbE RJ45. Complied
Warranty: 3 years NBD support Complied
4.17 NTP (NETWORK TIME PROTOCOL ) SERVER Complied
Technical Specifications: Complied
GPS/GLONASS satellite supported L1/L2/L5 frequency band, Rack
Mountable Type, NTP SERVER to maintain & display IP based NTP
Complied
time across the network containing L2/L3 switches shall be
supplied by the bidder.
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


NTP server shall act as master clock with accuracy better than
50ms in the network to which other clients shall interconnect over
the network using NTP client software on windows or Linux OS and Complied
synchronize periodically. It shall provide diagnostic and status
ports/indications for automatic/manual intervention.
The GPS NTP server shall be equipped with 02 or more Complied
independent network interfaces RJ45 (10/100/1000 Mbps NTP
output ports), Provide all interconnecting cable required for
connection between NTP server and other client.
Network Protocol: NTP v2/ v3/ v4 /SNTP/ IPv4/ TELNET /SSH. Complied
Vendor shall supply NTP server with all required accessories Complied
required for integration with SCCTV system
4.18 KVM SWITCH WITH INTEGRATED MONITOR Complied
Technical Specifications: Complied
17" LCD /LED MONITOR WITH INTEGRATED 8-PORT KVM SWITCH. Complied
Rack mountable Integrated KVM Switch shall be provided for
connecting Keyboard, Video and Mouse interfaces of the Servers.
KVM Switch shall be OEM integrated unit having 17” LCD/LED
foldable Monitor.
Keyboard & Mouse and a selection mechanism to allow connection
to each Server/device connected to the KVM.
The KVM switch shall be installed in the 19” Equipment Rack.
Port selection: Push button for selection of ports, reset 1X semi –
recessed push button.
KVM ports: 16x SPHD Female.
Rail Type: Single rail.
With required accessories.

4.19 SPEED DOME CONTROLLER JOYSTICK Complied


Control Mode : Network Complied
Display : LEC/LED Display Complied
ONVIF: Supported Latest Version Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Joystick Control : 6 Way operating Complied
Certification : CE,FCC Complied
4.20 VIDEO MANAGEMENT SOFTWARE : ALONG WITH CAMERA Complied
CONNECTION licenses
Technical Specifications: Complied
Supply of VMS Software for Camera Server, Complied
ANPR/NAS, Work-Station loaded in all the Servers to be provided
with Camera licenses suitable for all ONVIF Cameras with full
functionality, 3 concurrent client user licenses, 100% Failover
Recording, complete as per specifications with media (2 Nos.
software CD/media) and license as applicable.
Provision/Features covered in video surveillance software system: Complied
The software should have inbuilt facility to store configuration of Complied
cameras.
The software shall Support flexible 1/4/9/16/25 user defined Complied
Windows Split screen display mode or scroll mode on the
PC/Workstation monitor or on preview monitor as per site

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


requirement.
The software shall be able to control all cameras features such as Complied
PTZ control, Iris control, auto/manual focus, and colour balance of
camera, Selection of pre-sets, Video tour selection etc.
The software is required to generate reports of stored device Complied
configuration. The control software is required to provide alarm
and alarm log. The log shall be able to be archived, printed and
displayed using a device filter, a device group filter and/or a time
window.
The software shall have user access authority configurable on per Complied
device or per device group basis. The authorized user shall have
the facility to request the access of any camera and can control the
camera for a reservation period. Control of camera is released after
the reservation period.
The system software shall provide User activity Complied
log (audit trail) with user id, time stamp, and action performed,
etc.
The administrator shall be able to add, edit & delete users with Complied
rights. It shall be possible to view ability/ rights of each user or the
cameras which can be viewed & controlled as per the permission
assigned by the administrator.
The users shall be on a hierarchical basis as assigned by the Complied
administrator. The higher priority person can take control of
cameras, which are already being controlled by a lower priority
user. There shall be minimum 03 hierarchical levels of security for
providing user level log in.
The system software shall have recording modes viz. continuous, Complied
manual, or programmed modes on date, time and camera-wise. All
modes shall be disabled and enabled using scheduled
configuration. It shall also be possible to search and replay the
recorded images on date, time and camera wise. It shall provide
onscreen controls for remote operation of PTZ cameras. It shall have

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


the facility for scheduled recording. Different recording speeds
(fps) and resolution for each recording mode for each camera
shall be possible.
It shall provide programmable motion detection and recording, to Complied
be defined area-wise. Open interface to receive Motion trigger and
open interface to define the areas (at least four different areas)
should be available from the cameras. System must be able to
support video motion detection algorithms to detect and track
objects, learn the scene, adapt to a changing outdoor
environment, ignore environmental changes including rain, hail,
wind, swaying trees and gradual light changes. On Detection
software must be able to generate an alarm (visual/audio) to the
operator.
The settings shall be individually configurable for each alarm and Complied
each camera, pre-record duration. This shall allow the Camera
Server to capture
video prior to the alarm/event, as well as after the alarm/ event.
Shall be selectable from a list of values ranging between 0 seconds
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


and 5 minutes.
Data storage: Data storage should be at a central location in the
airport. The Capacity of storage should be for the minimum period
of continuous 30 days or more. For every 30 disks one spare disk Complied
needs to be configured over and above required capacity. The
storage system should follow FIFO on Recording .
The software shall support web based user connecting via the
Internet/Intranet and mobile Complied
OS (Android, iOS).
The software shall support a built-in Hardware or Software
Watchdog module. Watchdog shall monitor operation of all Complied
services and automatically restart them if they are malfunctioning.
The software should be able to receive alarm
signal of the camera and should be able to send relay out signal Complied
through the camera.
The software shall provide a facility for any alarm
Complied
input initiating any action in the SVMS system.
The software should provide a reporting utility for tracking but not
limited to the following options. Video and images shall be stored
with reports for documenting events.
Alarms, Incidents, Operator logs, Service requests.
The SMS/Email Alert shall be generated in response to alarms
triggered in SVMS software and sends out email alerts to a
preconfigured list of recipients.
It shall be possible to export the settings of various entities within
Complied
the SVMS i.e. Archive, Directory, cameras etc. It shall be possible to
print these reports.
It shall be possible to get reports on past events by querying the
audit databases. It shall allow the search by User Logon, Entity
Configuration, Incident, Alarm, Application Failure, and Equipment
Failure.
It shall allow passage of specific alarms to specified users rather

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


than sending all alarms to every user.
The system software should provide Analytic features such as
Intrusion, Line Crossing, Wrong direction movement, Unattended
Complied
object identification, Motion detection and Security device Alarm
etc. as per site requirement.
Detection software must be able to generate an alarm
Complied
(visual/audio) to the operator.
The software shall incorporate stronger security of security
mechanism to prevent vulnerabilities, man-in-the-middle attack by
Complied
providing digital certificate-based authentication between server
to server & server to clients.
The VMS Should have validated on Cyber-Security Readiness
certificate from either UL or any other equivalent reputed Complied
laboratory in India or Global.
VMS Shall support the Drive mapped redundancy, if one mapped
failed then automatically new recording shall be start next mapped Complied
storage drive.

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


VMS shall have provision to the transfer recorded video feed from
Complied
recording server storage to another specified storage.
VMS shall have provision to duplicate the archive video feed to
Complied
another location.
User facilities covered in application software: Complied
The user shall consist of Administrator Tool
application, a Monitoring application, and an Archive Player Complied
application.
The VMS client is required to perform the following applications
simultaneously without interfering with any of the Archive Server
operations (Recording, Alarms, etc.):
Live display of cameras
Control of PTZ cameras
Playback of archived video
Complied
Retrieval of archived video.
Instant Replay of live video.
Configuration of system settings.
simultaneous playback of multiple cameras in windows.
Search facility to find cameras from a tree of available cameras by
IP address, Camera Ids, Camera location name etc.
The user applications shall provide an authentication mechanism,
Complied
which verifies the validity of the user.
The user shall be able to define book marks, the amount of time he
wishes to go back from a Complied
predefined list or through a custom setup period.
The user shall be allowed to add bookmarks to recorded clips of
Complied
video.
The user shall be able to choose and trigger an action from a list of
available actions included but are not limited to:
View camera in a video tile.
View Map or procedure in video tile. Complied
Starting/ stopping PTZ pattern.

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Go to PTZ preset.
Sending alert messages.
The user shall be capable to display all camera sequences created
Complied
in the system.
The user shall be allowed for unlimited cameras sequences, which
can be run independently of each other on either of the monitor Complied
tiles.
The user shall be able to drag and drop a camera from a tree of
Complied
available cameras into any video tile for live viewing.
The user shall support digital zoom on a fixed/ PTZ camera’s live Complied
and recorded video streams.
The user shall be able to control pan-tilt-zoom, focus and dome Complied
relays.
The user shall be allowed to access the PTZ configuration menus Complied
with no need of additional hardware.
Integration Interface with Other System Complied
The system shall provide an integration interface to third party Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


systems using well defined API SDK/ Open Database Connectivity.
The API SDK for third party (Other system manufacturers involved
in this project) shall be provided along the system without any
additional cost which shall enable them to develop the software
interface with CCTV system. The software shall have the inbuilt
facility to seamlessly integrate to industry standards fire alarm
system & Building Management System (BMS) system
with/without any SDK.
4.21 ANPR SOFTWARE WITH Licenses Complied
The Automatic Number Plate Recognition (ANPR) system is
designed to be an Open Platform enterprise-class IP highly scalable
system architecture. It is a safe and robust management system
that can be scaled up from one single ANPR point to thousands of
cameras.
The ANPR system shall be audited & certified by at least 02
international or local auditing agencies for its performance
above 95%. The bidder has to provide the name of the agency Complied
and the accuracy score in the comments section of the
compliance sheet.
The ANPR system shall be designed to support any make of
cameras with any resolution and can detect license plates when Complied
the character height ranges from 14 to 70 pixels.
The ANPR system shall be able to detect the number plates of
all passing vehicles within fractions of a second. In a free-flow Complied
traffic environment.
The ANPR system read accuracy rate shall be more than 95%
excluding, but not limited to:
License plate missing from the vehicle.
License plate outside of the camera’s field of view
Damaged License Plates
Portions of the plate are missing. Complied
Tempered License Plates

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Specially crafted or customized Plates
Handwritten plate numbers
Visually blocked or obscured plates
Visually customized plates
The ANPR system shall be able to detect moving vehicles for
license plate recognition at the following speeds:
Low speed: 0-50km/h Complied
Medium speed: 51-90km/h
High speed : 91-130km/h
The ANPR system shall be used for the following objectives but
not limited for:
1. Monitoring all the real-time vehicle license plate transaction
records with the following details:
Complied
Date of capture, License Plate, Vehicle Image, Status, Camera,
Direction, Speed, Confidence, Average Digit height, Multiplate
rate, OCR processing time, Capturer ID, Capturer Type, Latitude
– Longitude, Alarm, etc.
The ANPR system shall be able to eliminate the duplicated Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


readings of the same plate by adopting a programmable
“duplicate timeout”.
The System shall automatically detect the license plate in the
Complied
captured video feed in real-time.
The system shall perform OCR (optical character recognition) of
the license plate characters (English alpha-numeric characters in Complied
standard fonts).
The System shall store JPEG image of vehicle and license plate
and enter the license plate number into DBMS solution (The Complied
Application should be based on Standard DBMS Solution)
System should be able to detect and recognize the English alpha
numeric License plate in standard fonts and formats of all four Complied
wheelers includingcars, HCV, and LCV.
The system shall be robust to variation in License Plates in terms
of font, size, contrast and colour and should work with good Complied
accuracy
The ANPR system shall be able to read license plates in double and
Complied
triple lines format.
The system shall have options to search historical records for
post event analysis by the vehicle colour or the vehicle colour Complied
with license plate and date time combinations
The system should have option to input certain license plates
according to the hot listed categories like “Lost” “Wanted”, Complied
“Suspicious”, “Stolen”, etc by authorized personnel.
The system should be able to generate automatic alarms to
alert the control room personnel for further action, in the event Complied
of detection of anyvehicle falling in the hot listed categories.
The ANPR system shall be able to perform a post-event forensic
search to search a particular vehicle based on:
a. Full license plate number.
b. Numerical character only. Complied
c. Alphabetical character only.

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


d. Vehicle full or partial pate together.
e. Any partial character combination fuzzy search.
The Instantaneous and automatic generation of alarms. In case
Complied
of identityof vehicle in any category which is define by user.
The ANPR system shall provide the live view of the camera
stream and auto save the following types of images of the
Vehicle: Complied
1. The snapshot of the read vehicle scene
2. The snapshot of the vehicle license plate
The ANPR system shall also be able to read a license plate from
recorded video received from non-configured cameras with Complied
common media formats such as .avi and .mp4 etc.
The ANPR system shall be able to “count” all vehicles that
passing a particular ANPR camera or a programmable zone with Complied
a user-selected time duration for total counting report export..
The system shall have Search option to tune the reports based
Complied
on license plate number, date and time, site location as per the

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


need of the
authorities.
The system shall have option to save custom reports for
subsequent use. The system shall have option to export report
Complied
being viewed to common format for use outside of the ANPRS or
exporting into other systems.
The system should provide advanced and smart searching
facility of License plates from the database. There should be an
Complied
option of searching number plates almost matching with the
specific number entered (up to 1 and 2 character distance.
The system should have option to input certain license plates
according to category like "Wanted", "Suspicious", and “Stolen", Complied
“Expired" etc. byAuthorized personnel.
The system should have an option to add new category by
Complied
authorizedpersonnel.
The system should have option to update vehicle status in specific
category by authorized personnel. e.g. on retrieval of stolen
Complied
vehicle, system entry should be changed from "Stolen" to
"Retrieved".
System should have option to specify maximum time to retain
Complied
vehiclerecords in specific categories.
System should have option to trigger alarm if same number of
Complied
vehicles arerunning more than one location.
The proposed VMS on integration with the ANPR system shall
establish a maintenance schedule for both the ANPR and VMS Complied
systems, including regular updates and patches.
The ANPR system OEM shall have a market presence for more
than 6 years with a dedicated in-house technical support team Complied
located in the India/Southeast Asia region.
THE ANPR system shall be a perpetual license and subscription-
Complied
based engine shall not be allowed.
4.22 VMS CLIENT/WORKSTSTION VIEWING LICENSE Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Technical Specification Complied
License should be valid till completion of 3 years of warranty and 3
Complied
years CAMC.
4.23 19”EQUIPMENT RACK (42U) Complied
Adjustable 19” equipment mounting verticals provide the better
mounting flexibility maximizing the usable mounting space • Depth
adjustable mounting slots • Top and bottom Panel with ventilation
and cable entry facility • Powder coated finish with pre-treatment
Complied
process meeting all industry standards • Grounding and Bonding
Options • 100% assured compatibility with all equipment
conforming to DIN 41494 or equivalent ISO standards. General
industrial standard for equipment.
Rack Standard: Conforms to DIN 41494 or equivalent ISO standards
Welded Frame: -
Front Door: Lockable Toughened Glass/perforated Door, Complied
Rear Door: Steel Perforated
Basic Frame: Steel

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Equipment Mounting: DIN Standard 10mm Sq. Slots Mounting
Angle: 19” Mounting angles made of formed steel
Standard Finish: Powder Coated Top and Bottom Cover: Welded to
Frame, Vented and Field Cable entry exit cut outs
Mounting Option: Castor wheels (Front 2 wheels with Break and
rear without break) with Levellers Standard Colour: Black or Grey
Static
Load : 500+ kgs.
Sidewalls, Split rear Doors, Baying Kits, Tool less Shelves, Casters,
Bolt Down Kits, Cable Management, Power Strips – Vertical or Complied
Rackmount, Tool less Blanking Panel.
Doors & Side Panels
• Power Distribution Units.
• Cable Managers.
• Fans and Fan Modules.
Complied
• Jacking Feet
• Mounting Hardware
• Cantilever Tray for Modem
• Earthing Kit.
Rack shall be provided with Top-mounted Fan unit (2 or more Fans)
for Air Circulation.
Equipment rack (standard 19”) fully wired for housing Central
Switches, Camera Servers, Storage servers, Analytic Servers, NTP
servers, NAS, KVM Switch with integrated 17” Monitor, etc.
All the Servers shall be installed in 19” 40/42U Rack with OEM Rack
Mounting Kit(s).
Wiring shall be neatly done with suitable cable manager.
Complied
Power supply wiring with suitable capacity sockets and proper
Earthing shall be neatly installed.
Rack shall include all required parts/accessories to install all
devices/ equipment. It shall have front and rear glass/perforated
cover with locks. Rack’s depth shall be sufficient to install all

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Servers and other network components and the doors remain
closed.
Power strip as per site requirement shall be provided.
4.24 19”EQUIPMENT RACK (9U) Complied
Conforms to DIN 41494 OR equivalent ISO Standards
• Adjustable 19” equipment mounting verticals provide the better
mounting flexibility maximizing the usable mounting space
• Depth adjustable mounting slots
• Top and bottom Panel with ventilation and cable entry facility
• Provision to mount the cooling fans on the top panel
Complied
• Powder coated finish with pre-treatment process meeting all
industry standards
• Grounding and Bonding Options
• 100% assured compatibility with all equipment conforming to
DIN 41494 or equivalent ISO standards. General industrial standard
for equipment.
Rack Standard: Conforms to DIN 41494 or equivalent ISO standards
Complied
Welded Frame
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Front Door: Lockable Toughened Glass Door, Rear Door: Steel
Perforated Basic
Frame: Steel Equipment
Mounting: DIN Standard 10mm Sq. Slots Mounting Angle: 19”
Mounting angles made of formed steel
Standard Finish: Powder Coated
Top and Bottom Cover: Welded to Frame, Vented and Field Cable
entry exit cut outs
Mounting Option: 19'' wall mount type networking/field rack(9U),
vented top cover with fan, cable entry provision for top and
bottom, Glass with lock and keys, front door.
Standard Colour : Black or Grey Static,
Sidewalls, Split rear Doors, Baying Kits, Tool less Shelves, Casters,
Bolt Down Kits, Cable Management, Power Strips - Vertical or Complied
Rackmount, Tool less Blanking Panels, cooling Fans.
Doors & Side Panels
• Power Distribution Units.
• Cable Managers.
• Fans and Fan Modules.
Complied
• Jacking Feet
• Mounting Hardware
• Cantilever Tray for Modem
• Earthing Kit
Rack shall be provided with Top-mounted Fan unit (2 or more Fans)
Complied
for Air Circulation.
Power strip as per site requirement. Complied
4.25 19”OUTDOOR WEATHER PROOF EQUIPMENT RACK (9U)
The cabinet is made of galvanized steel, with Single wall
1.2mm/1.5mm and double walls thickness of outer plate: 1.2mm
/1.5mm, thickness of inner plate: 0.8mm. There is heat insulation Complied
between inner wall and outer wall. The insulation material is 25-
30mm. The cabinet is assembled type.

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


he cabinet Have Single Door with One Side Hinged and Other Side
Locking. The door opening angle is larger than 110°. The lock Knob Complied
type, padlock Provision available
The cabinet is dustproof, sun proof and rainproof, which is used in
outdoor environment.
The cabinet cooling uses Forced Air Cooling through Single/Dual
Fan of 230V 90 CFM (Higher CFM on request) The layout of the
cabinet is reasonable, which will facilitate cable access, fixing and
grounding. At the bottom of the cabinet, there are entrance holes Complied
individually for power cable, signal cable and optical cable. All the
cables, sealing and heat insulation used in the cabinet are made
from flame retardant materials. The cabinet uses assembled
structure, easy for installation. The cabinet includes 19” standard
installation rack.
IP (Ingress Protection) Rating : P55,NEMA 3R,NEMA 4 Complied
Working Temperature: -10~55℃ Complied
Cooling : AC110~120V or 220~240V Cooling Fan, 2x cooling fans for Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


keep airflow circulation between inside and outside cabinet, with
filter and vented holes on the door
Power: PDU(Basic or Smart),AC/DC Power, Built-in Power Optional Complied
Sensors : Door Sensor/Water Sensor/Temperature & Humidity
Complied
sensor/Smoke sensor/Tilt & Shock sensor
Monitoring: EMS,KVM Switches, Smart PDU Complied
Harsh environment(Waterproof): Rain hood and high-grade
Complied
polyurethane door joint strip for waterproof features
Cable access : Pre-cutting cable opening holes, with cable grommet
Complied
or gland options
Electrical grounding: The front door is grounded to the frame of
Complied
the enclosure.
4.26 25 MM DIA 16 SWG MS CONDUIT (ISI MARKED) Complied
25mm diameter Good quality industry standard 25 MM MS
Complied
Conduit 16 SWG Industrial Grade
4.27 OFC OUTDOOR CABLE (6 CORE SMF 9/125 µm Complied
General features: Complied
All OFC, Ethernet cables and associated accessories shall be
supplied, installed, tested and commissioned by the bidder.
Category-6 UTP cable and associated accessories such Information Complied
Outlet, Patch Cords, Patch Panel, Terminations, Cable Management
Panel, etc. shall be used for provision of LAN.
All Terminating connectors, line units and accessories for OFC cable
Complied
shall be supplied and installed as per site requirements.
All cable incoming and outgoing from any Rack/device shall be
Complied
appropriately numbered and marked for easy identification.
Networking accessories such as Jack/ Patch panel, mounting rack,
face plate, mounting cord & connecting cables, Information
outlets, modules and connectors etc. as required for the complete Complied
network design shall be supplied and installed by the bidder within
the quoted cost.
Technical Specification Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


The fiber is optimized for operation at 1310 nm and at 1550 nm. Complied
The Fiber should be Armoured 6 core unitube 9/125 µm SM fiber
with central loose tube jelly compound, Glass Yarns in between Complied
Steel Tape & Loose Tube.
Armour Tape : Corrugated steel Tape Armoured Complied
Jacket material : HDPE Complied
Outer diameter : 9 ± 0.3 mm Complied
Thickness of the Jacket: 1.8 + 0.2 mm Complied
Pulling Tension: Short Term 2000N, Long term 1000N Complied
Crush Load: 3000N/100mm Complied
The Fiber Operating Temperature should be – 20 deg C to +60 deg
Complied
C and
The Fiber Max Attenuation ± 0.36 (db / km) @ Operational
Wavelength 1310 nm and, ± 0.22 (db / km) @ Operational Complied
Wavelength 1550 nm .
The Fiber - type should be 9/125 / G.652D & Refractive Index
Complied
should be 1.4670/1.4675
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


The value for Mode-filed/Cladding Diameter (um) 9.2 ± 0.4 and
Complied
125 ± 0.7
The Dispersion value <=3.5 <=18 (ps/(nm-km) and PMD value
Complied
<=0.2 (ps/km) and Cable Cut-off wavelength <=1260 (nm)
The Fiber should follow Standards: ISO 11801, IEC 60793-1/60794-
Complied
1-2 and ITU-T-REC G.652D
Testing methods are in accordance with the following standards:
Complied
ITUT G.652.D, IEC 793-1 and Telecordia : GR-20 Core,ISO : 11801
OEM Should be International certification for the ISO 45001 Health
and Safety Management System, ISO 9001 Quality Management
Complied
System, ISO 14001 Environmental Management System, and ISO
14064-1 Greenhouse Gas Inventory Standards.
OFC Connectors Complied
It shall be single mode SC/LC type with push-pull mechanism, fully
in compliance, with latest industry standards. It shall be possible Complied
for selection of wide range of ferrule hole diameter selection.
OFC Adaptors Complied
It shall be suitable for single mode SC/LC type fibre cable
connectors which shall be fully in compliance with latest industry Complied
standard. It shall be with snap/latch mechanism.
OFC Patch Cords Complied
It shall be suitable for single mode SC type fibre cable connectors
with plastic moulded plug type connectors. Standard ceramic Complied
ferrules shall be used. It shall be compact and easy to connect.
Patch Cords Complied
Push & pull design with latch and Shall be wired straight through. Complied
Bend relief compliant boots to ensure proper Cat 6 performance. Complied
Patch Panel
Complied
Conform to EIA standards, UL rated.
Have port identification numbers on both front and rear of the
Complied
panel.
Media Converter Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Appropriate media converters shall be used along with requisite
L3/L2 switches to meet and maintain Gigabit Ethernet Complied
communications.
4.28 40 MM DIA HPDE PIPIE PN6 Complied
HDPE (High Density polyethylene)
Optical Fibre Cable ducts. Smooth inside & outside surface free
from blisters, shrink, hole, scratches & roughness
Outer diameter: 50 + 0.4 / - 0.0 mm
Wall Thickness: 3.5 +/- 0.2 mm
Crush Resistance: deflection shall be less than 10% with 50 kg load Complied
for 1 minute and recovery for 5 minutes shall be less than 2%
Impact Strength: There Should be no crack or split when 10 kg load
dropped from 1.5 mtr height after conditioning at 0 deg
Accessories: Coupler, End Plug, Endcap shall be included 27.8
Suitable for direct burial applications
4.29 CAT-6 UTP DATA CABLE Complied
All cables used for the project shall be supplied as under: Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


ISO certified cables of reputed make & model. Complied
Confirm to ISI/ISO/IEC/BIS or better standards. All cables for this
Complied
work must be used as ISI standard and fire retarded.
Ensure high bandwidth, low attenuation and low losses in signal
Complied
quality.
Technical Specification Complied
Category 6 Unshielded Twisted Pair 4 pair 100W cable shall be
Complied
compliant with ANSI/TIA/EIA-568-C.2
Category 6 UTP cables shall extend between the work area location
and its associated telecommunications closet and consist of 4 pair, Complied
23 AWG, UTP
The 4 pair Unshielded Twisted Pair cable shall be UL/ETL Complied
Category 6 should operate on bandwidth up to 250MHz as per
Complied
standard.
4 twisted pairs separated by internal X shaped, 4 channel, full
Complied
separator. Half shall not be accepted.
Conductor Should be 23 AWG Solid bare copper Complied
Conductor Insulation material should be High Density Polyethylene
& Sheath: FR PVC, PVC GREY- Single sheath, Insulation Thickness Complied
0.2 mm Nominal
Pairs two insulated conductors Twisted Together Complied
Each meter printed with sequential Length Counter Complied
Pulling Force: 11.5Kg, Complied
Temperature Rating -20° to +70°C Complied
Storage Temperature Rating 0° to +50°C Complied
Filler Required, RIP cord Complied
PACKING : Reels of 305m Length with spool. Complied
Conductor Resistance (DC) 9.38 OHMS/100 MTR Complied
Rsistance Unbalance 5%MAX Complied
Mutual Capacitance 5.6 nF/100 mtrs Max. Complied
Capacitance Unbalance 330PF/100M MAX Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Nominal Velocity of Propagation 69% Complied
Charcteristics Impendance 100±15%OHMS Complied
Worst Case cable skew 45ns/100m Complied
Generally confirming to EIA/TIA 568-C.2 and IEC/ISO 11801 Complied
OEM Should be International certification for the ISO 45001 Health
and Safety Management System, ISO 9001 Quality Management
Complied
System, ISO 14001 Environmental Management System, and ISO
14064-1 Greenhouse Gas Inventory Standards
4.30 ARMOURED 3 CORE POWER CABLE Complied
Armoured 3 core 1.5 sq mm multi-strand insulated PVC sheathed
Complied
copper conductor power cable
High Performance 3 Core 1.5 Sq mm multistrand copper cable in
existing conduit /pipe on surface /recess /concealed with Complied
connectors and termination.
Insulation: Polyethylene Complied
4.31 OUTDOOR JUNCTION BOX Complied
Rated voltage: up to 1000V
Complied
Material: ABS
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Waterproof junction boxes IP65
Attractive space-efficient design.
• Enclosures available in Thermo Plastic / DB / Polycarbonate as
per requirement.
• A variety of different push button and control switch designs; as
per the site requirement
• Illuminated push buttons are also available.
• All systems are equipped with rubber gaskets for weather
protection.
• Front openable covers can also be available with hinges, to
ensure easy maintenance.
4.32 RJ-45 IO FACEPLATE with Gang box/ Back box Complied
Technical Specification Complied
Face plate should be single port with Back box. Complied
Face Plate should have shutter to protect from dust. Complied
It should have write on labels in transparent plastic window -
Complied
supplied with plate.
Face plate material: ABS with white color. Complied
Screw should be supplied with face plate. Complied
OEM for the cable Box and all copper Accessories should be from
Complied
same OEM.
4.33 LIGHT GUARD INTER CONNECT UNIT(LIU) with 6 port/12 port/24
Complied
port
Rack Mount Type LIU with 6 port/12 port/24 port of reputed
standard make/model, fully populated with required modules,
connectors and all accessories, etc. shall be supplied and installed
as required. It shall be installed for terminating the OFC cables. It
shall provide minimum bending radius and the splice trays shall
function as a splice cover for pigtail splicing. It shall be of complete Complied
aluminum fully powder coated. Cable glands shall be provided for
secure anchoring the incoming cables. Rubber grommets shall be
provided at the cable entry point for tight sealing. The splice tray

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


shall also be of aluminum powder coated with splice holder. Cable
and spools shall be of flame-retardant type.
4.34 SC-LC PATCH CORD Complied
It shall be suitable for single mode LC type fibre cable connectors
with plastic moulded plug type connectors. Standard ceramic Complied
ferrules shall be used. It shall be compact and easy to connect.
4.35 GI PLOE FOR MOUNTING OF CAMERA Complied
GI Pole of 3" dia, up to 6 Mtrs, Standard ISI Make. height from
ground level with accessories shall be supplied and installed for Complied
mounting of camera.
The pole shall be grouted with MS base plate of size 300 mm x 300
mm x 6 mm under the ground embedded in concrete complete as
per site requirement. The pole shall have Weather proof junction
Complied
box where all the cables shall be terminated. The supply and
Installation of pole also covers civil and mechanical works including
painting.
4.36 20 KVA ONLINE UPS

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


GENERAL Complied
20 KVA Online UPS in Parallel redundant configuration (1+1) (Qty.:
2 nos.) with SMF batteries for minimum 30 minutes of battery Complied
backup:
20 KVA Floor Mounted On-Line UPS 1+1 (Three Phase AC Input &
Complied
Three-Phase AC Output) with input/output Isolation Transformer
(There shall be nothing common between input & output
connections/leads) and Individual SMF Battery Bank to provide
minimum 30 minutes Battery back-up for each UPS, RS 232 Serial Complied
Port or RJ45 with Software for Computer Interface and Redundant
Configuration
UPS operation shall be configured in such a way that the failure of
one UPS shall result in total load to be automatically transferred to Complied
other UPS of the cluster.
Vendors shall replace batteries every two years after the
installation during the entire period of Three years warranty & Complied
Three years CAMC.
TECHNICAL SPECIFICATIONS: Complied
UPS shall be free from workmanship defects. The Equipment shall
be complete with all parts and all parts shall be functional.
i. UPS shall supply output power and charging current at the same
time. Complied
ii. Switching device shall be IGBT or equivalent. iv. Digital Signal
Processors (DSP) shall be used for all monitoring and control
electronics of UPS.
Input: 350V-450V , 50 Hz ± 3% Three Phase AC. Complied
Output: 350V-450V, 50 Hz ± 3% Three Phase AC and, 230V ± 1%
(with alternative setting for 220V ± 1%) 50 ± 0.5Hz Single phase AC.
Voltage regulation from no load to full load shall be within ± 1% in
Complied
both the cases. UPS shall also have facility for operation in
synchronous mode in which output frequency shall be same as
that of mains frequency.

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Efficiency (at rated output voltage and frequency): Overall
Complied
efficiency (minimum): 90%
UPS power factor at rated load: better than 0.8 lagging or better. Complied
Over load: UPS shall withstand 20% overload for 1 minute and 50%
Complied
over load for 30 seconds
Protections: Following protection shall be provided in UPS: Complied
a. Over voltage, short circuit, and overload at UPS output terminal. Complied
b. Under voltage at battery terminal. Complied
c. Overshoot and undershoot shall not be greater than 4% of rated
Complied
voltage for duration of 40m sec. (maximum)
Indicators and meters: Complied
a. Following indicators shall be provided: Complied
(i) Mains presence. Complied
(ii) Battery charging and discharging Complied
(iii) Output overload Complied
(iv) Low battery voltage. Complied
b. Digital Panel meter shall be provided for monitoring the Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


following parameters in UPS:
(i) Input AC voltage. Complied
(ii) Output AC Voltage, current and frequency Complied
(iii) Battery voltage and current Complied
Battery bank: Complied
UPS shall be supplied with SMF VRLA battery only. Complied
Bidders shall declare battery AH capacity, battery voltage, number
of batteries of each rating, make and model of batteries offered Complied
with each item of UPS.
Batteries for UPS shall be one of the following makes: EXIDE/
Complied
Rocket /PANASONIC /AMRON or equivalent.
The UPS shall be complete with rack for battery bank and the firm
Complied
shall connect the batteries with UPS and commission the same.
Minimum AH rating of battery bank with suitable rack for the
Complied
duration of back up time shall be as detailed below:
UPS rating in KVA: 20 KVA; Min. 30 minutes back up: Batteries 12Vx
Complied
65 AH or higher
Manufacturers Authorization Form (MAF) from OEM shall be
Complied
provided.
4.37 ACCESS CONTROL DEVICE Complied
FINGER+CARD BIOMETRIC READER CUM CONTROLLER Complied
4.37.1 Access Control Reader Complied
Biometric: Fingerprint with Fake Detection Inbuilt Complied
RF Option: Must support 125kHz EM & 13.56MHz MIFARE, iClass
Complied
MIFARE Plus, DESFire, FeliCa
CPU:
Complied
1 GHz Quad Core or better
Memory : 16GB Flash + 1GB RAM or better Complied
LCD Type : Minimum 4” IPS color LCD Complied
LCD Resolution: 400 x 800 pixels or better Complied
Configurable mode : Only Finger, Only card, PIN Code, Card +

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Complied
Finger, PIN+Finger, All in one device.
IP Rating : IP65 or better Complied
Certificates : BIS, CE, FCC, RoHS, Complied
Resolution : 500 dpi or better Complied
Template : ISO19794-2, ANSI-378 Complied
Extractor / Matcher : MINEX certified and compliant Complied
Live Fingerprint Detection : Must support Complied
Must support : 50000 or better Complied
Max. Text Log: 5000000 or better Complied
Ethernet : 10/100 Mbps, auto MDI/MDIX Complied
RS-485 : Must support Complied
Wiegand & OSDP : Must support Complied
TTL Input : 2ch Inputs or better Complied
Relay : 1 Relay or better Complied
USB : USB 2.0 or better Complied
Tamper : Supported Complied
4.37.2 Access Control Software Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


A. System Architecture Complied
1. A web-based security platform, capable of managing access
Complied
control system with Ethernet network connectivity.
1. Access Control Complied
1) User management Complied
2) Device management Complied
3) Door management Complied
4) Elevator management Complied
5) Zone management (Anti-pass back, Fire Alarm, Schedule Lock,
Complied
Schedule Unlock, Intrusion Alarm, Interlock, and Muster)
6) Access group management Complied
7) Monitoring (Event log, Real-time log, Device status, Door
status, Floor status, Zone status, Image log, Alert history and Complied
Graphic Map)
8) Alarm management Complied
9) RFID card management Complied
10) Audit trail Complied
2. Standard Transmission Control Protocol (TCP/IP)
networking communication protocol between server, Complied
clients, and devices.
3. Support Dynamic Host Configuration Protocol (DHCP) or
Complied
Static IP address.
4. Support network configuration. Complied
5. Support Network Time Protocol (NTP). Complied
6. Support HTTPS communication protected by Secure
Socket Layer (SSL) between the client (Web browser) and Complied
platform.
7. Support AES-256 for User Name, Fingerprint Template,
Complied
and Face Template.
8. Support AES-256 for Fingerprint Template and Face
Complied
Template (Optional).

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


9. Support SHA-256 for PIN and Password. Complied
10. Support export to CSV or PDF for list items. Complied
B. Interface
1. Use a Web-based client user interface for configuration, Complied
administration, management, and monitoring.
C. User Complied
1. User ID:
a. Support numeric user ID. Complied
b. Support alphanumeric user ID (Optional).
2. Support expiration dates (Period) for user. Complied
3. Operator levels:
Complied
a. Provide for a maximum of 6 pre-defined levels.
b. Provide for a maximum of 6 pre-defined levels. Complied
c. Provide for an unlimited number of custom operator levels. Complied
d. Each level shall have a set of permissions and shall be able to be
Complied
configured for different operator levels.
4. Custom Field: Provide 3 types of custom user field.
Complied
Support the Text Input Box, Number Input Box, and Combo
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Box.
Provide for a maximum of 20 custom fields.
5. Fingerprint : Support up to 10 fingers (20 templates) per
Complied
user.
D. Device Complied
1. Support auto search and manual search for a device. Complied
2. Allow the user to change the device settings and perform the
action include:
a. Firmware upgrade
b. Factory reset
c. Lock/Unlock
d. Time zone
Complied
e. Time synchronization
f. Network configuration
g. Serial (RS-485) configuration
h. Authentication settings
i. Card format settings
o. Auto synchronization with server
E. Door Complied
1. Supported door configuration include:
a. Two devices (entry device and exit device) for one door.
Complied
b. Entry device for one door with exit button.
c. Entry device for one door without exit button.
2. Support two types of relay setting for the exit button and door
sensor. Complied
a. Normally open and normally closed
3. Allow the user to configure the door settings include:
a. Entry device selection
b. Relay selection for a door lock
c. TTL input port for an exit button
d. TTL input port for a door sensor
Complied
e. Relay release time for door lock

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


f. Dual authentication settings
g. Held open time and alarm
h. Forced open alarm
i. Anti-pass back alarm
H. Zone Complied
1. Anti-pass back Complied
a. User shall be able to define the areas and assign the entry
Complied
devices and exit devices to configure an anti-pass back zone.
b. Support the global APB zone which can be set with all devices
Complied
enrolled in Software.
c. Support the local APB zone which can be set with the entry
Complied
devices and exit device connected with RS-485.
d. Allow the user to configure an anti-pass back zone include: Complied
1) APB zone mode (Global or Local) Complied
2) Active or inactive temporarily Complied
3) APB type (Hard APB or Soft APB) Complied
4) Auto reset time Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


5) Entry device and exit devices selection for the APB zone Complied
6) Network failure action Complied
7) Customizable signal output for alarm Complied
8) Bypass user group configuration Complied
2. Fire Alarm Complied
a. User shall be able to define the areas and assign the doors
Complied
and/or elevators to configure a fire alarm zone.
b. Support the global fire alarm zone which can be set with all
Complied
devices enrolled in Software
c. Support the local fire alarm zone which can be set with the
Complied
entry devices and exit device connected with RS-485.
d. Allow the user to configure a fire alarm zone include:
1) Fire alarm zone mode (Global or Local).
2) Active or inactive temporarily. Complied
3) Door and/or elevator selection for the fire alarm zone.
4) Customizable signal output for alarm.
3. Scheduled Lock Complied
a. User shall be able to define the areas and assign the doors and
Complied
schedule to configure a scheduled lock zone.
b. Allow the user to configure a scheduled lock zone include:
1) Active or inactive temporarily
2) Door lock method selection
Complied
3) Door and schedule selection for the scheduled lock zone
4) Customizable signal output for alarm
5) Bypass user group configuration
4. Scheduled Unlock Complied
a. User shall be able to define the areas and assign the doors and
Complied
schedule to configure a scheduled unlock zone.
b. Allow the user to configure a scheduled unlock zone include:
1) Active or inactive temporarily
2) Started by user authentication option
Complied
3) Door and schedule selection for the scheduled unlock zone

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


4) Access group where the user belongs who can start a
scheduled unlock
5. Intrusion Alarm Complied
a. User shall be able to define the areas and assign the doors to
Complied
configure an intrusion alarm zone.
b. Support the global intrusion alarm zone which can be set with
Complied
all devices enrolled in Access Control Software.
c. Support the local intrusion alarm zone which can be set with
Complied
the entry devices and exit device connected with RS-485.
d. Allow the user to configure an intrusion alarm zone include:
1) Intrusion alarm zone mode (Global or Local)
2) Active or inactive temporarily Complied
3) Door selection for detecting intrusion
4) Arm and/or disarm settings
e. Support the synchronizing user data stored in Microsoft
Complied
Windows Active Directory to ACS Software
4.37.1 Exit door push button Complied

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


Technical Features Complied
Operating Power: 12 or 24 VDC
Holding Force: 600 Lbs or equivalent.
Mounting type: Surface/Door
Complied
Monitoring Option: Lock Status Sensor (LSS), LED indicator
Certifications and standards: BIS
Guarantee/Warranty: 03 Years
4.37.2 SINGLE DOOR EM LOCK 600 LBS WITH ALL ACCESSORIES Complied
600 lbs EM Lock with Feedback are Suitable for access controlled &
secure areas within buildings. It has Green/red LED indication for
lock status, Design with no Mechanical Bolt.
1. Magnet (L X W X H): 250 X 42 X 26 mm or better.
2. Armature Plate (L X W X H): 180 X 38 X 11 mm Complied
3. Current: 400 mA
4. Power: 12V
5. Holding Force: 600lbs
6. Holding Capacity: 200 kg or better
4.37.3 12 V 5 Amp POWER SUPPLY Complied
4.29 EXCAVATION IN SOFT/HARD SOIL & ROAD CUTTING Complied
4.38.1 Excavation in Soft/ Hard Soil with the required depth up to 75 cm
Complied
& Backfilling, as per specifications
4.38.2 The contractor is required to dig the earth up to 75 cm. for
underground laying of cables wherever required. The contractor
shall resurface the road/earth same as earlier, as per industry
standards with sand cushioning and Brick protection. Road Cutting Complied
with the required depth up to 75 cm & Backfilling shall be done as
per industry standards and making good as per finish with cement
& concrete.
4.39 2 PORT SFP ,2 PORT COPPER MEDIA CONVERTER Complied
Technical Features Complied
1. Should be Single Mode

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


2. Fiber wavelength Should be 1300nm
3. Max. Distance Should be 10Km
4. Should be compliant with 802.3u & 802.3x.
5. Should have One RJ - 45 and dual Fiber port (SC type connector)
6. Forwarding mode: Store and Forward
7. Packet Buffer Memory: 1Mbit
8. Power Consumption Max at 240 V: 1.5W
9. Power Consumption Standby at 240 V: 1.3W
Complied
10. MTBF - hours 10,0000 hours
11. Auto MDI/MDIX
12. Auto-Negotiation
13. Status LED’s for information
14. Operating Temperature 0° C to 50° C, Storage Temperature -20°
C to 70° C
15. Operating Humidity 5% to 90% non - condensing 31.16
Operating Voltage AC 240V or DC +5V 31.17 Emission EMI and
Safety Certifications CE, FCC
4.40 POWER DISTRIBUTION PANEL (PDP) Complied
RRG Engineering Technologies Pvt. Ltd.
Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


4.40.1 The power distribution panels shall be provided with MCB (As per
Complied
load) to meet the system requirement along with UPS.
4.40.2 The power distribution panel shall provide MCB's with proper
ratings for all equipment including field equipment like Network Complied
Switches, Cameras, Workstations, Displays etc.
4.40.3 Sufficient number of loops are required to be made to avoid high
current passing in single loop one MCB for each loop and mains Complied
control switch.
4.41 TRAINING & DOCUMENTATION Complied
The bidder firm along with OEM partner firm shall provide
Complied
following types of training as detailed below:
4.41.1 Operation, Maintenance and System Administration Training. Complied
1. On the Job operation, maintenance and system
administration training of minimum THREE trainees
nominated by AAI, for five working days at site. The
Complied
training shall be designed and structured so that on
successful completion of the training the participants shall
be able to perform basics of SCCTV System.
2. Configuration, optimization and alignment of the system
with the help of the documents and software supplied Complied
along with the equipment /system.
3. Breakdown maintenance of the system Complied
4. Fault isolation up to Module level using diagnostic tools
Complied
and general-purpose test equipment.
5. Preventive maintenance of the system. Complied
6. The vendor shall provide training material and documents
Complied
during Training.
4.41.2 On the Job Operators Training Complied
1. One batch consisting of around EIGHT-TEN Operators for
Complied
three days at site.
2. The bidder firm shall provide appropriate training to

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


familiarize the operators with
3. Basics of SCCTV systems
Complied
4. Present system setup and configuration offered.
5. Optimization and alignment of the system with software
supply and the equipment.
6. the operational features of the equipment so as to make
Complied
optimum use of the facility.
7. This training shall include all topics essential for operations
Complied
including user defined.
8. configurations and controls. Complied
9. The bidder and OEM firm shall identify the prerequisite for
the trainees for each of the training program. Appropriate
Complied
training documentation shall be provided to each trainee
as reference and guidance material.
4.41.3 Documentation Complied
1. THREE (03 nos.) SETS EACH OF SOFT COPY AND HARD
Complied
COPY of Operations, Technical and Maintenance manual,

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com


etc. shall be supplied.
2. All manuals and documents shall be in English language
and in such a way that a qualified engineer/technician is
Complied
able to fully understand and do the preventive as well as
breakdown maintenance with the help of these manuals.
3. The Technical and Maintenance manual will cover: Complied
a. General technical description and theory of operation
b. Block diagram (layout diagram of cables/OFC/power
cables) of complete system.
c. Servicing/ Maintenance instructions including preventive
maintenance schedule.
d. Fault analysis and repair procedures.
Complied
e. installation procedures for software, configuration
recovery, reloading of software modules of application
software.
f. Technical & operational manuals.
g. Maintenance manuals.
h. Maintenance and System Administrative procedures.
4.42 EARTHING Complied
4.42.1 The system shall be configured to be grounded electrically to a
common ground point to prevent interference to the system from
external and internal sources and to protect equipment and
Complied
personnel.
Earthing of the System: The contractor firm shall provide the
Earthing to the system.
4.42.2 Standard Chemical Earthing in order to maintain the earth
Complied
resistance at the pit < 2 ohms .
4.42.3 The Earth Resistance of Chemical Earthing should be less than 1
Ohm, which ensures a low-impedance path for electrical currents
Complied
to flow to the earth. Chemical Mixture The Chemical mixture used
in Chemical Earthing consists of Bentonite, Salt, and Charcoal.
4.43 INSTALLATIONS Complied

An ISO 9001-2015 |ISO27001-2013|ISO45001-2018 Certified Company


Installation of cctv system with comprehensive support, Testing,
Commissioning of the complete system with required accessories,
of all CCTV equipment including networking, cabling etc., Complied
configuration of individual equipment as per specifications,
training & documentation at the site

RRG Engineering Technologies Pvt. Ltd.


Regd. Address: 08, Prajay Meadows, Rd. No. 12, Banjara Hills, Hyderabad – 500034. Telangana, India
Phone: +91 – 40 – 3517 2698,35172699,35172701 | info@rrgengineering.com

CIN: U29219TG2008PTC058777 | GST: 36AAECR0362B1ZV Website: www.rrgengineering.com

You might also like