COLUMN DESIGN CALCULATIONS


Project Name : a
Client Name : a
Engineer Name : a
Design File : C:\Users\Acer\Desktop\Projects\Structural Analysis -
Copy\Structure1-Column-1.rcdx
Analysis File : C:\Users\Acer\Desktop\Projects\Structural Analysis -
Copy\Structure1.STD
Analysis Last Modified : 01/03/2024 11:52:35 pm

Definitions Of Terms:
All forces in units kN and m
All reinforcement details like area, spacing in mm
Neutral axis angle for resultant design moment is with respect to local major axis.
Ratio to account for reduction of stiffness of columns
1 βdns =
due to sustained axial loads
Moment magnification factor for frames not braced
2 δns =
against sidesway
First-order relative deflection between the top and
3 Δo =
bottom of the story due to Vu in mm
4 ∑Pu = Total factored vertical load in kN. (Clause 10.10.5.2)
5 δu = Design displacement in mm
Modification factor reflecting the reduced mechanical
6 λ =
properties of concrete
Coefficient defining the relative contribution of
7 ac =
concrete strength to nominal wall shear strength
Cross-sectional area of a structural member measured
8 Ach = to the outside edges of transverse reinforcement in
sqmm
Gross area of concrete section bounded by web
9 Acv = thickness and length of section in the direction of
shear force considered in sqmm
Effective cross-sectional area within a joint in a plane
10 Aj = parallel to plane of reinforcement generating shear in
the joint in sqmm
Area of non-prestressed longitudinal tension
11 As =
reinforcement in sqmm
Minimum area of shear reinforcement within spacing
12 Avmin =
's' in sqmm
13 B = Width of column/ wall in mm
Cross-sectional dimension of member core measured
14 bc = to the outside edges of the transverse reinforcement
composing area Ash in mm
Distance from extreme compression fiber to neutral
15 c =
axis in mm
16 Cc = Clear cover to longitudinal reinforcement in mm
Factor relating actual moment diagram to an

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 2 of 227

17 Cm = equivalent uniform moment diagram


18 D = Depth / diameter of column in mm
Distance from extreme compression fiber to centroid
19 d =
of longitudinal tension reinforcement in mm
Distance from extreme compression fiber to centroid
20 d' =
of longitudinal compression reinforcement,mm
21 Ec = Modulus of elasticity of concrete in N/sqmm
22 EI = Flexural stiffness of compression member in N-sqmm
Specified compressive strength of concrete cylinder in
23 f'c =
N/sqmm
24 fy = Specified yield strength of reinforcement in N/sqmm
Specified yield strength fy of transverse
25 fyt =
reinforcement in N/sqmm
Height of entire wall from base to top of wall segment
26 hw =
considered in mm
27 Icr = Moment of Inertia of concrete crack section
28 k = Effective length factor for compression member
Length of compression member in a frame, measured
29 lc =
center-to-center of the joints in the frame in mm
Moment of inertia of gross concrete section about
30 lg =
centroidal axis neglecting reinforcement in mm4
31 lw = Length of entire wall in mm
Un-supported length for compression member along
32 lux =
D in mm
Un-supported length for compression member along
33 luy =
B in mm
Moment capacity of section for a given NA angle at
34 MCap =
design Pu in kNm
35 Mcr = Cracking Moment
Resultant design moment at a given load angle to
36 MRes =
local major axis in kNm
Factored moment amplified for the effects of member
37 Mc = curvature used for design of compression member in
kNm
Factored moment modified to account for effect of
38 Mm =
axial compression in kNm
Factored moment acting on a section along D in kNm
39 Mux =
(From Analysis)
Factored moment acting on a section along B in kNm
40 Muy =
(From Analysis)
Smaller factored end moment on a compression
41 M1 =
member in kNm
Factored end moment on a compression member at
42 M1ns = the end at which M1 acts, due to loads that cause no
appreciable sidesway in kNm
Factored end moment on compression member at the
43 M1s = end at which M1 acts, due to loads that cause
appreciable sidesway in kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 3 of 227

Smaller factored end moment on a compression


44 M1sldr =
member due to slenderness effect in kNm
Larger factored end moment on compression member
45 M2 =
in kNm
Minimum value of moment M2 as per minimum
46 M2min =
eccentricity of column
Factored end moment on compression member at the
47 M2ns = end at which M2 acts, due to loads that cause no
appreciable sidesway in kNm
Factored end moment on compression member at the
48 M2s = end at which M2 acts, due to loads that cause
appreciable sidesway in kNm
Largest factored end moment on a compression
49 M2sldr =
member due to slenderness effect in kNm
50 Mnb = Flexure Capacity for Beam
51 Mnc = Flexure Capacity for Column
Nominal Flexure strength of column at top along
52 Mnty =
depth in kNm
Nominal Flexure strength of column at bottom along
53 Mnby =
depth in kNm
Nominal Flexure strength of column at top along
54 Mntx =
width in kNm
Nominal Flexure strength of column at bottom along
55 Mnbx =
width in kNm
Factored axial force normal to cross section occurring
56 Nu =
simultaneously with Vu in kN
57 Pc = Critical buckling load in kN
Ratio of area of distributed transverse reinforcement
58 pt = to gross concrete area perpendicular to that
reinforcement
59 Pω = Ratio of As to B x d
60 Q = Stability index for storey
Radius of gyration of cross section of a compression
61 r =
member in mm
62 Vc = Nominal shear strength provided by concrete in kN
63 Vj = Shear Force acting at the joint in kN
64 Vn = Nominal shear strength in kN
65 Vn' = Nominal shear strength at joint in kN
66 Vus = Factored horizontal shear in a storey in kN
Factored shear at section along D in kN (From
67 Vux =
Analysis)
Shear induced due to column flexural capacity along
68 Vux1 =
width, kN
Shear due to enhanced earthquake factor along
69 Vux2 =
width, kN
Factored shear at section along B in kN (From
70 Vuy =
Analysis)
Shear induced due to column flexural capacity along

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 4 of 227

71 Vuy1 = depth, kN
Shear due to enhanced earthquake factor along depth,
72 Vuy2 =
kN
73 y = Neutral axis depth.
It is a Neutral Axis angle corresponding to load angle
74 β =
to find out MCap

Code References:
ACI 318M - 2011
Sr.No Element Clause / table
Minimum area of longitudinal reinforcement
1 : 21.6.3
for column
Maximum area of longitudinal
2 : 21.6.3
reinforcement for column
Minimum longitudinal and transverse
3 : 21.9.2.1
reinforcement for wall
4 Minimum diameter of transverse ties : 7.10.5
5 Minimum spacing of transverse ties : 7.10.5
Maximum spacing of longitudinal and
6 : 21.9.2.1
transverse reinforcement for wall
7 Applicability of boundary element : 21.9.6
Area and spacing of special confining
8 : 21.6.4
reinforcement
9 Slenderness Moments : 10.10
Shear Strength provided by concrete for
10 : 11.2
column
11 Design of shear for non-ductile wall : 11.9
12 Design of shear for ductile wall : 21.9.4
13 Minimum Flexural Strength of Columns : 21.6.2.2
14 Shear Check at Column Joint : 21.7.4.1
15 Shear Strength of Column : 21.3.3 & 21.5.4
16 fs,perm : 10.6.4
17 fc,perm : 10.2.7.1
18 Wcr : Eq 4.2(a)

Sway Calculation (Stability Index)


For Global-X Direction
Level Load Story Gravity Relative Story Stability Sway
Combination Height Load P Displacements Shear (kN) Index (Q) Condition
Analysis (m) (kN) (mm)
B x C / (A x
A B C D
D)
0m to 3m 216 3 7085.959 2.578 678.37 0.009 Non Sway

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 5 of 227

3m to
216 2.8 2873.471 2.758 396.298 0.007 Non Sway
5.8m
5.8m to
216 2.8 119.534 1.702 28.583 0.003 Non Sway
8.6m

For Global-Y Direction


Level Load Story Gravity Relative Story Stability Sway
Combination Height Load P Displacements Shear (kN) Index (Q) Condition
Analysis (m) (kN) (mm)
B x C / (A x
A B C D
D)
0m to 3m 220 3 7085.959 2.552 678.37 0.009 Non Sway
3m to
220 2.8 2873.471 2.524 396.298 0.007 Non Sway
5.8m
5.8m to
220 2.8 119.534 1.697 28.583 0.003 Non Sway
8.6m

General Data
Column No. : C1
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1102
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 291.72 kN
Muxt = -53.59 kNm
Muyt = 4.73 kNm
Vuxt = 6.6 kN
Vuyt = 43.01 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 6 of 227

Pub = 305.55 kN
Muxb = 75.4 kNm
Muyb = -15.06 kNm
Vuxb = 6.6 kN
Vuyb = 43.01 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
2000 x 300 x
Top 71.111 No Beam 80 - 1.841
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4994 x 300 x 2786 x 300 x
Top 71.111 32.038 57.43 1.646
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 7 of 227

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = -53.59 kNm
M2 = 75.4 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = 4.73 kNm
M2 = -15.06 kNm
Min (40, 34 - 12 x (M1/M2)) = 37.77
19.59 < 37.77, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -53.59 - -53.59
Major Axis Mux (bottom) 75.4 - 75.4
Minor Axis Muy (top) 4.73 - 4.73
Minor Axis Muy (bottom) -15.06 - -15.06

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 305.55 kN
Mux = 75.4 kNm
Muy = -15.06 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 8 of 227

[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD


Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN
Pu = 622.49 kN
Mux = -70.06 kNm
Muy = 26.18 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Pu = 622.49 kN
φ Pn = 622.49 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 11.29 deg
MRes = 76.89 kNm
( φ ) MCap = 156.07 kNm
Capacity Ratio = MRes/ MCap
= 0.493 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 305.55 kN
Muy = 75.4 kNm
Vuy = 43.009 kN
λ = 1
φ = 0.75
deff = 340.5 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 9 of 227

ρw (50% of As provided) = 0.014


Mm = 27.3 kNm
φVcy = 94.99 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 116
[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 353.51 kN
Mux = 60.3 kNm
Vux = 27.5815 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 4.64 kNm
φVcx = 131.76 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 10 of 227

General Data
Column No. : C1
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2102
Critical Analysis Load Combination : 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 8: EQ -Z -E)
Critical Location = Top Joint
Put = 139.18 kN
Muxt = 31.61 kNm
Muyt = 45.78 kNm
Vuxt = 35.51 kN
Vuyt = -14.78 kN
Pub = 157.25 kN
Muxb = -9.76 kNm
Muyb = -53.61 kNm
Vuxb = 35.51 kN
Vuyb = -14.78 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
2000 x 300 x
Bottom 76.19 No Beam 80 - 1.841
400
Top 76.19 2975 x 300 x No Beam 36.029 - 2.116

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 11 of 227

350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4994 x 300 x 2786 x 300 x
Bottom 76.19 32.038 57.43 1.646
400 400
4994 x 300 x 250 x 300 x
Top 76.19 21.463 428.75 0.169
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.74
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = -9.76 kNm
M2 = 31.61 kNm
Min (40, 34 - 12 x (M1/M2)) = 37.71
21.22 < 37.71, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.74
r = 115.47 mm
Klux /r = 15.7

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 12 of 227

M1 = 45.78 kNm
M2 = -53.61 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
15.7 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 31.61 - 31.61
Major Axis Mux (bottom) -9.76 - -9.76
Minor Axis Muy (top) 45.78 - 45.78
Minor Axis Muy (bottom) -53.61 - -53.61

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 139.18 kN
Mux = 31.61 kNm
Muy = 45.78 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 274.26 kN
Mux = -15.26 kNm
Muy = 37.27 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 274.26 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 13 of 227

φ Pn = 274.26 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 55.37 deg
MRes = 55.64 kNm
( φ ) MCap = 132.61 kNm
Capacity Ratio = MRes/ MCap
= 0.42 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 209.98 kN
Muy = 60.92 kNm
Vuy = -34.304 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 27.86 kNm
φVcy = 92.09 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 116
[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 97.51 kN
Mux = 51.49 kNm
Vux = 34.3542 kN
λ = 1
φ = 0.75
deff = 340.5 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 14 of 227

ρw (50% of As provided) = 0.014


Mm = 36.14 kNm
φVcx = 89.73 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C2
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 15 of 227

Load Data
Analysis Reference No. = 1110
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 470.18 kN
Muxt = -69.62 kNm
Muyt = -2.72 kNm
Vuxt = -0.66 kN
Vuyt = 50.93 kN
Pub = 484.01 kN
Muxb = 83.13 kNm
Muyb = -0.73 kNm
Vuxb = -0.66 kN
Vuyb = 50.93 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3400 x 300 x 3100 x 300 x
Top 71.111 47.059 51.613 1.492
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4994 x 300 x 450 x 300 x
Top 71.111 32.038 238.194 0.545
400 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.73
axis

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 16 of 227

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = -69.62 kNm
M2 = 83.13 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.73
r = 115.47 mm
Klux /r = 16.75
M1 = -0.73 kNm
M2 = -2.72 kNm
Min (40, 34 - 12 x (M1/M2)) = 30.76
16.75 < 30.76, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -69.62 - -69.62
Major Axis Mux (bottom) 83.13 - 83.13
Minor Axis Muy (top) -2.72 - -2.72
Minor Axis Muy (bottom) -0.73 - -0.73

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 17 of 227

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 484.01 kN
Mux = 83.13 kNm
Muy = -0.73 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint kN
Pu = 650.05 kN
Mux = 85.03 kNm
Muy = -0.86 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Pu = 650.05 kN
φ Pn = 650.05 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 0.5 deg
MRes = 83.13 kNm
( φ ) MCap = 178.68 kNm
Capacity Ratio = MRes/ MCap
= 0.465 < 1

Design Of Shear

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 18 of 227

Design for shear along D


Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 381.07 kN
Muy = 73.17 kNm
Vuy = -43.8757 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 13.17 kNm
φVcy = 109.78 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 381.03 kN
Mux = 18.69 kNm
Vux = -22.243 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -41.3 kNm
φVcx = 192.59 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 19 of 227

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C2
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2109
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Top Joint
Put = 263.26 kN
Muxt = -66.63 kNm
Muyt = 30.68 kNm
Vuxt = 19.64 kN
Vuyt = 45.62 kN
Pub = 281.33 kN
Muxb = 61.07 kNm
Muyb = -24.29 kNm
Vuxb = 19.64 kN
Vuyb = 45.62 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 20 of 227

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
3400 x 300 x 3100 x 300 x
Bottom 76.19 47.059 51.613 1.492
400 400
3400 x 300 x 2125 x 300 x
Top 76.19 31.526 50.441 0.929
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4994 x 300 x 450 x 300 x
Bottom 76.19 32.038 238.194 0.545
400 350
4994 x 300 x 300 x 200 x
Top 76.19 21.463 150 0.444
350 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.68
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 21 of 227

r = 115.47 mm
Kluy /r = 18.25
M1 = 61.07 kNm
M2 = -66.63 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
18.25 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.68
r = 115.47 mm
Klux /r = 14.72
M1 = -24.29 kNm
M2 = 30.68 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
14.72 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -66.63 - -66.63
Major Axis Mux (bottom) 61.07 - 61.07
Minor Axis Muy (top) 30.68 - 30.68
Minor Axis Muy (bottom) -24.29 - -24.29

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 263.26 kN
Mux = -66.63 kNm
Muy = 30.68 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint kN
Pu = 281.33 kN
Mux = 61.07 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 22 of 227

Muy = -24.29 kNm


Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Pu = 281.33 kN
φ Pn = 281.33 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 24.73 deg
MRes = 73.36 kNm
( φ ) MCap = 144.32 kNm
Capacity Ratio = MRes/ MCap
= 0.508 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 225
[53] : 1.38 (LOAD 9: DL) +(LOAD 2:
Critical Load Combination = kN
EQ +X -E)
Nu = 210.53 kN
Muy = 62.99 kNm
Vuy = 42.9381 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 29.84 kNm
φVcy = 93.84 kN
Vuy < φVcy
Link For Shear Design Along D are not required

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 23 of 227

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 252.37 kN
Mux = 58.13 kNm
Vux = 38.9005 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 18.4 kNm
φVcx = 99.53 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C3
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 24 of 227

Grade Of Steel (fy) = Fy420 N/sqmm


Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1115
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 222.36 kN
Muxt = -71.12 kNm
Muyt = 4.58 kNm
Vuxt = 0.64 kN
Vuyt = 51.67 kN
Pub = 236.19 kN
Muxb = 83.85 kNm
Muyb = 2.67 kNm
Vuxb = 0.64 kN
Vuyb = 51.67 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 3400 x 300 x
Top 71.111 106.667 47.059 0.958
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 25 of 227

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4994 x 300 x 450 x 300 x
Top 71.111 32.038 238.194 0.545
400 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.73
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 115.47 mm
Kluy /r = 17.34
M1 = -71.12 kNm
M2 = 83.85 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
17.34 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.73
r = 115.47 mm
Klux /r = 16.75
M1 = 2.67 kNm
M2 = 4.58 kNm
Min (40, 34 - 12 x (M1/M2)) = 27.01
16.75 < 27.01, Column not slender along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 26 of 227

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -71.12 - -71.12
Major Axis Mux (bottom) 83.85 - 83.85
Minor Axis Muy (top) 4.58 - 4.58
Minor Axis Muy (bottom) 2.67 - 2.67

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 236.19 kN
Mux = 83.85 kNm
Muy = 2.67 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN
Pu = 548.46 kN
Mux = -70.88 kNm
Muy = -19.7 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Pu = 548.46 kN
φ Pn = 548.46 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 27 of 227

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 1.82 deg
MRes = 83.89 kNm
( φ ) MCap = 148.91 kNm
Capacity Ratio = MRes/ MCap
= 0.563 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 236.19 kN
Muy = 83.85 kNm
Vuy = 51.6692 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 46.66 kNm
φVcy = 91.05 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 116
[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 317.36 kN
Mux = 28.99 kNm
Vux = 26.6405 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -20.97 kNm
φVcx = 185.9 kN
Vux < φVcx
Link For Shear Design Along B are not required

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 28 of 227

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C3
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2113
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Top Joint

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 29 of 227

Put = 127.49 kN
Muxt = -70.32 kNm
Muyt = 46.47 kNm
Vuxt = 33.33 kN
Vuyt = 48.13 kN
Pub = 145.56 kN
Muxb = 64.42 kNm
Muyb = -46.81 kNm
Vuxb = 33.33 kN
Vuyb = 48.13 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x 3400 x 300 x
Bottom 76.19 106.667 47.059 0.958
400 400
1500 x 300 x 3400 x 300 x
Top 76.19 71.458 31.526 0.74
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.75
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4994 x 300 x 450 x 300 x
Bottom 76.19 32.038 238.194 0.545
400 350
4994 x 300 x 300 x 200 x
Top 76.19 21.463 150 0.444
350 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.68
axis

Check For Stability Index


Along D
Q = 0.007

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 30 of 227

0.007< 0.05, Column shall be designed as non-sway frame


(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.75
r = 115.47 mm
Kluy /r = 15.91
M1 = 64.42 kNm
M2 = -70.32 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
15.91 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.68
r = 115.47 mm
Klux /r = 14.72
M1 = 46.47 kNm
M2 = -46.81 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
14.72 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -70.32 - -70.32
Major Axis Mux (bottom) 64.42 - 64.42
Minor Axis Muy (top) 46.47 - 46.47
Minor Axis Muy (bottom) -46.81 - -46.81

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 31 of 227

Pu = 127.49 kN
Mux = -70.32 kNm
Muy = 46.47 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN
Pu = 202.72 kN
Mux = -16.18 kNm
Muy = -41.47 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Pu = 202.72 kN
φ Pn = 202.72 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 33.46 deg
MRes = 84.29 kNm
( φ ) MCap = 132.19 kNm
Capacity Ratio = MRes/ MCap
= 0.638 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 217
Critical Load Combination = [45] : 1.68 (LOAD 9: DL) +0.5 (LOAD kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 32 of 227

10: LL) +(LOAD 2: EQ +X -E)


Nu = 127.49 kN
Muy = 70.32 kNm
Vuy = 48.1341 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 50.24 kNm
φVcy = 89.79 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 159.97 kN
Mux = 71.42 kNm
Vux = 50.5099 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 46.24 kNm
φVcx = 90.92 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 33 of 227

Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C4
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1120
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint
Put = 50 kN
Muxt = 52.72 kNm
Muyt = 19.97 kNm
Vuxt = 13.48 kN
Vuyt = -41.06 kN
Pub = 63.83 kN
Muxb = -70.41 kNm
Muyb = -20.47 kNm
Vuxb = 13.48 kN
Vuyb = -41.06 kN

Effective Length Calculation


Calculation Along Major Axis Of Column

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 34 of 227

Joint Column Beam Sizes Beam Stiffness ψ


Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x
Top 71.111 No Beam - 106.667 1.38
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4994 x 300 x 2265 x 300 x
Top 71.111 32.038 47.323 1.859
400 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = 52.72 kNm
M2 = -70.41 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 35 of 227

Column Is Braced Along B


Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.97
M1 = 19.97 kNm
M2 = -20.47 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.97 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 52.72 - 52.72
Major Axis Mux (bottom) -70.41 - -70.41
Minor Axis Muy (top) 19.97 - 19.97
Minor Axis Muy (bottom) -20.47 - -20.47

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 63.83 kN
Mux = -70.41 kNm
Muy = -20.47 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint kN
Pu = 399.04 kN
Mux = 80.96 kNm
Muy = 11.82 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 36 of 227

Minimum Ast Calculation


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Pu = 399.04 kN
φ Pn = 399.04 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 16.21 deg
MRes = 73.33 kNm
( φ ) MCap = 126.74 kNm
Capacity Ratio = MRes/ MCap
= 0.579 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 63.83 kN
Muy = 70.41 kNm
Vuy = -41.0556 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 60.37 kNm
φVcy = 87.45 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 115
[15] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 190.67 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 37 of 227

Mux = 54.03 kNm


Vux = 28.52 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 24.01 kNm
φVcx = 91.73 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C4
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 38 of 227

Clear Floor Height @ luy = 2450 mm


No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2117
Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 7: EQ -Z +E)
Critical Location = Top Joint
Put = 88.04 kN
Muxt = -22.03 kNm
Muyt = 67.23 kNm
Vuxt = 47.2 kN
Vuyt = 15.29 kN
Pub = 106.11 kN
Muxb = 20.77 kNm
Muyb = -64.9 kNm
Vuxb = 47.2 kN
Vuyb = 15.29 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x
Bottom 76.19 No Beam - 106.667 1.38
400
1500 x 300 x
Top 76.19 No Beam - 71.458 1.066
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 39 of 227

4994 x 300 x 2265 x 300 x


Bottom 76.19 32.038 47.323 1.859
400 350
4994 x 300 x 300 x 200 x
Top 76.19 21.463 150 0.444
350 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.8
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = 20.77 kNm
M2 = -22.03 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.8
r = 115.47 mm
Klux /r = 17.32
M1 = -64.9 kNm
M2 = 67.23 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
17.32 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -22.03 - -22.03
Major Axis Mux (bottom) 20.77 - 20.77

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 40 of 227

Minor Axis Muy (top) 67.23 - 67.23


Minor Axis Muy (bottom) -64.9 - -64.9

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 88.04 kN
Mux = -22.03 kNm
Muy = 67.23 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint kN
Pu = 156.21 kN
Mux = 48.34 kNm
Muy = -27.55 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 2: EQ +X -E)
Pu = 156.21 kN
φ Pn = 156.21 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 41 of 227

= 71.86 deg
MRes = 70.75 kNm
( φ ) MCap = 129.49 kNm
Capacity Ratio = MRes/ MCap
= 0.546 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 138.14 kN
Muy = 54.55 kNm
Vuy = 36.7546 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 32.8 kNm
φVcy = 91.16 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 88.04 kN
Mux = 67.23 kNm
Vux = 47.2013 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 53.37 kNm
φVcx = 89.17 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 42 of 227

> Max. longitudinal bar dia / 4


= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C5
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1103
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 247.3 kN
Muxt = -43.57 kNm
Muyt = 12.93 kNm
Vuxt = 10.65 kN
Vuyt = 34.79 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 43 of 227

Pub = 261.13 kN
Muxb = 60.76 kNm
Muyb = -19.01 kNm
Vuxb = 10.65 kN
Vuyb = 34.79 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
2000 x 300 x
Top 71.111 No Beam 80 - 1.841
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4800 x 300 x 4994 x 300 x
Top 71.111 33.333 32.038 2.257
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 44 of 227

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = -43.57 kNm
M2 = 60.76 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = 12.93 kNm
M2 = -19.01 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -43.57 - -43.57
Major Axis Mux (bottom) 60.76 - 60.76
Minor Axis Muy (top) 12.93 - 12.93
Minor Axis Muy (bottom) -19.01 - -19.01

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 261.13 kN
Mux = 60.76 kNm
Muy = -19.01 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 219

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 45 of 227

[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD


Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Critical Location = Bottom Joint kN
Pu = 494.99 kN
Mux = -51.75 kNm
Muy = 7.34 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Pu = 494.99 kN
φ Pn = 494.99 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 17.37 deg
MRes = 63.66 kNm
( φ ) MCap = 148.28 kNm
Capacity Ratio = MRes/ MCap
= 0.429 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 261.13 kN
Muy = 60.76 kNm
Vuy = 34.7874 kN
λ = 1
φ = 0.75
deff = 340.5 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 46 of 227

ρw (50% of As provided) = 0.014


Mm = 19.65 kNm
φVcy = 96.63 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 311.33 kN
Mux = 65.76 kNm
Vux = -35.3783 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 16.74 kNm
φVcx = 99.52 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 47 of 227

General Data
Column No. : C5
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2103
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Top Joint
Put = 282.62 kN
Muxt = 28.07 kNm
Muyt = -67.96 kNm
Vuxt = -39.44 kN
Vuyt = -14.11 kN
Pub = 300.69 kN
Muxb = -11.43 kNm
Muyb = 42.43 kNm
Vuxb = -39.44 kN
Vuyb = -14.11 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
2000 x 300 x
Bottom 76.19 No Beam 80 - 1.841
400
Top 76.19 2975 x 300 x No Beam 36.029 - 2.786

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 48 of 227

350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4800 x 300 x 4994 x 300 x
Bottom 76.19 33.333 32.038 2.257
400 400
4800 x 300 x 4994 x 300 x
Top 76.19 22.331 21.463 2.293
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = -11.43 kNm
M2 = 28.07 kNm
Min (40, 34 - 12 x (M1/M2)) = 38.89
21.22 < 38.89, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 49 of 227

M1 = 42.43 kNm
M2 = -67.96 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 28.07 - 28.07
Major Axis Mux (bottom) -11.43 - -11.43
Minor Axis Muy (top) -67.96 - -67.96
Minor Axis Muy (bottom) 42.43 - 42.43

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 282.62 kN
Mux = 28.07 kNm
Muy = -67.96 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Critical Location = Bottom Joint kN
Pu = 321.58 kN
Mux = -43.39 kNm
Muy = -19.84 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Pu = 321.58 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 50 of 227

φ Pn = 321.58 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 67.56 deg
MRes = 73.53 kNm
( φ ) MCap = 146.81 kNm
Capacity Ratio = MRes/ MCap
= 0.501 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 112
[12] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 222.29 kN
Muy = 48.61 kNm
Vuy = -31.3604 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 13.61 kNm
φVcy = 101.13 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 201.39 kN
Mux = 64.29 kNm
Vux = -39.4043 kN
λ = 1
φ = 0.75
deff = 340.5 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 51 of 227

ρw (50% of As provided) = 0.014


Mm = 32.59 kNm
φVcx = 91.91 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C5
Level : 5.8m To 8.6m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 52 of 227

Load Data
Analysis Reference No. = 3101
Critical Analysis Load Combination : 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 8: EQ -Z -E)
Critical Location = Top Joint
Put = 23.44 kN
Muxt = 10.67 kNm
Muyt = 20.63 kNm
Vuxt = 10.03 kN
Vuyt = -7.62 kN
Pub = 33.6 kN
Muxb = -10.66 kNm
Muyb = -7.46 kNm
Vuxb = 10.03 kN
Vuyb = -7.62 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 2.786
5600 x 200 x
Top 24.107 No Beam 8.036 - 3.013
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 2.293
4900 x 200 x
Top 24.107 No Beam 9.184 - 2.606
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 53 of 227

Check For Stability Index


Along D
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 86.6 mm
Kluy /r = 28.87
M1 = -10.66 kNm
M2 = 10.67 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 86.6 mm
Klux /r = 28.87
M1 = -7.46 kNm
M2 = 20.63 kNm
Min (40, 34 - 12 x (M1/M2)) = 38.34
28.87 < 38.34, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 10.67 - 10.67
Major Axis Mux (bottom) -10.66 - -10.66
Minor Axis Muy (top) 20.63 - 20.63
Minor Axis Muy (bottom) -7.46 - -7.46

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 54 of 227

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 23.44 kN
Mux = 10.67 kNm
Muy = 20.63 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 33.6 kN
Mux = -10.66 kNm
Muy = -7.46 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 33.6 kN
φ Pn = 33.6 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 62.65 deg
MRes = 23.22 kNm
( φ ) MCap = 53.62 kNm
Capacity Ratio = MRes/ MCap
= 0.433 < 1

Design Of Shear

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 55 of 227

Design for shear along D


Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 21.32 kN
Muy = 14.61 kNm
Vuy = -10.3443 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 12.05 kNm
φVcy = 46.31 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 211
[39] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 14: WL -Z)
Nu = 18.34 kN
Mux = 18.9 kNm
Vux = 12.0073 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 16.7 kNm
φVcx = 45.82 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 56 of 227

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C6
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1111
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 457.82 kN
Muxt = -52.32 kNm
Muyt = -0.3 kNm
Vuxt = 0.53 kN
Vuyt = 39.11 kN
Pub = 471.65 kN
Muxb = 64.97 kNm
Muyb = -1.9 kNm
Vuxb = 0.53 kN
Vuyb = 39.11 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 57 of 227

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3400 x 300 x 3100 x 300 x
Top 71.111 47.059 51.613 1.492
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4800 x 300 x 4994 x 300 x
Top 71.111 33.333 32.038 2.257
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 58 of 227

M1 = -52.32 kNm
M2 = 64.97 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = -0.3 kNm
M2 = -1.9 kNm
Min (40, 34 - 12 x (M1/M2)) = 32.11
19.59 < 32.11, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -52.32 - -52.32
Major Axis Mux (bottom) 64.97 - 64.97
Minor Axis Muy (top) -0.3 - -0.3
Minor Axis Muy (bottom) -1.9 - -1.9

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 471.65 kN
Mux = 64.97 kNm
Muy = -1.9 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 639.83 kN
Mux = 64.44 kNm
Muy = -1.5 kNm
Pt Calculated = 1.21

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 59 of 227

φ Pn, Max = 2170.33 kN


Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 639.83 kN
φ Pn = 639.83 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 1.67 deg
MRes = 65 kNm
( φ ) MCap = 177.08 kNm
Capacity Ratio = MRes/ MCap
= 0.367 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 401.74 kN
Muy = 42.98 kNm
Vuy = -33.0722 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -20.27 kNm
φVcy = 194.71 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 60 of 227

Critical Analysis Load Combination : 116


[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 426.9 kN
Mux = 30.01 kNm
Vux = 28.7825 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -37.2 kNm
φVcx = 197.27 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C6
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 61 of 227

Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2110
Critical Analysis Load Combination : 230
Load Combination = [58] : 1.38 (LOAD 9: DL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint
Put = 229.59 kN
Muxt = -0.43 kNm
Muyt = 48.55 kNm
Vuxt = 37.31 kN
Vuyt = 0.6 kN
Pub = 244.43 kN
Muxb = 1.24 kNm
Muyb = -55.88 kNm
Vuxb = 37.31 kN
Vuyb = 0.6 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
3400 x 300 x 3100 x 300 x
Bottom 76.19 47.059 51.613 1.492
400 400
3400 x 300 x 2125 x 300 x
Top 76.19 31.526 50.441 1.223
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 62 of 227

Stiffness Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4800 x 300 x 4994 x 300 x
Bottom 76.19 33.333 32.038 2.257
400 400
4800 x 300 x 4994 x 300 x
Top 76.19 22.331 21.463 2.293
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = -0.43 kNm
M2 = 1.24 kNm
Min (40, 34 - 12 x (M1/M2)) = 38.15
21.22 < 38.15, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22
M1 = 48.55 kNm
M2 = -55.88 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along B

Calculation of Design Moment

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 63 of 227

Direction Manalysis Msldr or Mc Mdesign-final


A B C
Major Axis Mux (top) -0.43 - -0.43
Major Axis Mux (bottom) 1.24 - 1.24
Minor Axis Muy (top) 48.55 - 48.55
Minor Axis Muy (bottom) -55.88 - -55.88

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 244.43 kN
Mux = 1.24 kNm
Muy = -55.88 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 319.88 kN
Mux = 45.07 kNm
Muy = -14.64 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 319.88 kN
φ Pn = 319.88 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 64 of 227

Moment Capacity Check


Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 88.73 deg
MRes = 55.89 kNm
( φ ) MCap = 149.99 kNm
Capacity Ratio = MRes/ MCap
= 0.373 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 112
[12] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 194.92 kN
Muy = 41.62 kNm
Vuy = -28.3782 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 10.94 kNm
φVcy = 103.58 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 115
[15] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 225.98 kN
Mux = 54.4 kNm
Vux = 36.0384 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 18.82 kNm
φVcx = 97.85 kN
Vux < φVcx
Link For Shear Design Along B are not required

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 65 of 227

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C6
Level : 5.8m To 8.6m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 3103
Critical Analysis Load Combination : 108
[8] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +(LOAD
Load Combination =
14: WL -Z)
Critical Location = Bottom Joint
Put = 26.04 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 66 of 227

Muxt = -4.75 kNm


Muyt = 24.48 kNm
Vuxt = 17.94 kN
Vuyt = 2.79 kN
Pub = 33.3 kN
Muxb = 3.05 kNm
Muyb = -25.74 kNm
Vuxb = 17.94 kN
Vuyb = 2.79 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1.223
3500 x 200 x 5600 x 200 x
Top 24.107 12.857 8.036 1.148
300 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 2.293
4900 x 200 x
Top 24.107 No Beam 9.184 - 2.606
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 67 of 227

Along B
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 86.6 mm
Kluy /r = 28.87
M1 = 3.05 kNm
M2 = -4.75 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 86.6 mm
Klux /r = 28.87
M1 = 24.48 kNm
M2 = -25.74 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -4.75 - -4.75
Major Axis Mux (bottom) 3.05 - 3.05
Minor Axis Muy (top) 24.48 - 24.48
Minor Axis Muy (bottom) -25.74 - -25.74

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 33.3 kN
Mux = 3.05 kNm
Muy = -25.74 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 68 of 227

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 42.86 kN
Mux = 3.98 kNm
Muy = -15.9 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 42.86 kN
φ Pn = 42.86 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 83.25 deg
MRes = 25.92 kNm
( φ ) MCap = 52.11 kNm
Capacity Ratio = MRes/ MCap
= 0.497 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 26.82 kN
Muy = 16.49 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 69 of 227

Vuy = 10.6009 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 13.28 kNm
φVcy = 46.1 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 211
[39] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 14: WL -Z)
Nu = 33.3 kN
Mux = 25.74 kNm
Vux = 17.942 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 21.75 kNm
φVcx = 46.19 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 70 of 227

Spacing 300 --- --- 300 ---

General Data
Column No. : C7
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1116
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 316.5 kN
Muxt = -58.34 kNm
Muyt = -8.11 kNm
Vuxt = -5.63 kN
Vuyt = 42.08 kN
Pub = 330.33 kN
Muxb = 67.88 kNm
Muyb = 8.78 kNm
Vuxb = -5.63 kN
Vuyb = 42.08 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 71 of 227

Width x Depth) Width x Depth)


N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 3400 x 300 x
Top 71.111 106.667 47.059 0.958
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4800 x 300 x 4994 x 300 x
Top 71.111 33.333 32.038 2.257
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 115.47 mm
Kluy /r = 17.34
M1 = -58.34 kNm
M2 = 67.88 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
17.34 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 72 of 227

K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = -8.11 kNm
M2 = 8.78 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -58.34 - -58.34
Major Axis Mux (bottom) 67.88 - 67.88
Minor Axis Muy (top) -8.11 - -8.11
Minor Axis Muy (bottom) 8.78 - 8.78

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 330.33 kN
Mux = 67.88 kNm
Muy = 8.78 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Critical Location = Bottom Joint kN
Pu = 635.41 kN
Mux = -50.43 kNm
Muy = -6.24 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 219

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 73 of 227

[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD


Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Pu = 635.41 kN
φ Pn = 635.41 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 7.37 deg
MRes = 68.44 kNm
( φ ) MCap = 159.47 kNm
Capacity Ratio = MRes/ MCap
= 0.429 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 330.33 kN
Muy = 67.88 kNm
Vuy = 42.0844 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 15.87 kNm
φVcy = 104.06 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 115
[15] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 391.71 kN
Mux = 29.72 kNm
Vux = 27.94 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 74 of 227

λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -31.95 kNm
φVcx = 193.69 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C7
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 75 of 227

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2114
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 1: EQ +X +E)
Critical Location = Top Joint
Put = 193.56 kN
Muxt = -63.18 kNm
Muyt = 2.98 kNm
Vuxt = 5.89 kN
Vuyt = 43.84 kN
Pub = 211.63 kN
Muxb = 59.54 kNm
Muyb = -13.5 kNm
Vuxb = 5.89 kN
Vuyb = 43.84 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x 3400 x 300 x
Bottom 76.19 106.667 47.059 0.958
400 400
1500 x 300 x 3400 x 300 x
Top 76.19 71.458 31.526 0.974
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4800 x 300 x 4994 x 300 x
Bottom 76.19 33.333 32.038 2.257
400 400
4800 x 300 x 4994 x 300 x

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 76 of 227

Top 76.19 350 350 22.331 21.463 2.293


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 115.47 mm
Kluy /r = 16.34
M1 = 59.54 kNm
M2 = -63.18 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.34 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22
M1 = 2.98 kNm
M2 = -13.5 kNm
Min (40, 34 - 12 x (M1/M2)) = 36.65
21.22 < 36.65, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -63.18 - -63.18
Major Axis Mux (bottom) 59.54 - 59.54
Minor Axis Muy (top) 2.98 - 2.98
Minor Axis Muy (bottom) -13.5 - -13.5

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 77 of 227

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 193.56 kN
Mux = -63.18 kNm
Muy = 2.98 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Critical Location = Bottom Joint kN
Pu = 257.72 kN
Mux = -25.31 kNm
Muy = -1.97 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 4: EQ -X -E)
Pu = 257.72 kN
φ Pn = 257.72 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 2.7 deg
MRes = 63.25 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 78 of 227

( φ ) MCap = 143.34 kNm


Capacity Ratio = MRes/ MCap
= 0.441 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 193.56 kN
Muy = 63.18 kNm
Vuy = 43.8411 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 32.71 kNm
φVcy = 93.01 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 115
[15] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 175.37 kN
Mux = 49.1 kNm
Vux = 32.3044 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 21.49 kNm
φVcx = 94.38 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 79 of 227

Criterion for spacing of normal links


Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C7
Level : 5.8m To 8.6m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 3105
Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 7: EQ -Z +E)
Critical Location = Top Joint
Put = 17.05 kN
Muxt = -4.5 kNm
Muyt = 17.68 kNm
Vuxt = 10.11 kN
Vuyt = 4.03 kN
Pub = 27.21 kN
Muxb = 6.79 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 80 of 227

Muyb = -10.63 kNm


Vuxb = 10.11 kN
Vuyb = 4.03 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 0.974
3500 x 200 x
Top 24.107 No Beam - 12.857 1.891
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 2.293
4900 x 200 x
Top 24.107 No Beam 9.184 - 2.606
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 81 of 227

Column Is Braced Along D


Slenderness Check along D
K = 0.87
r = 86.6 mm
Kluy /r = 25.11
M1 = -4.5 kNm
M2 = 6.79 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
25.11 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 86.6 mm
Klux /r = 28.87
M1 = -10.63 kNm
M2 = 17.68 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -4.5 - -4.5
Major Axis Mux (bottom) 6.79 - 6.79
Minor Axis Muy (top) 17.68 - 17.68
Minor Axis Muy (bottom) -10.63 - -10.63

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 17.05 kN
Mux = -4.5 kNm
Muy = 17.68 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 82 of 227

Critical Location = Bottom Joint kN


Pu = 28.07 kN
Mux = 14.34 kNm
Muy = -4.61 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 28.07 kN
φ Pn = 28.07 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 75.72 deg
MRes = 18.24 kNm
( φ ) MCap = 51.41 kNm
Capacity Ratio = MRes/ MCap
= 0.355 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 28.07 kN
Muy = 14.34 kNm
Vuy = 9.373 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 10.97 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 83 of 227

φVcy = 46.29 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 17.05 kN
Mux = 17.68 kNm
Vux = 10.1146 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 15.64 kNm
φVcx = 45.56 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C8

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 84 of 227

Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1121
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint
Put = 66.57 kN
Muxt = 37.4 kNm
Muyt = 14.44 kNm
Vuxt = 10.75 kN
Vuyt = -30.32 kN
Pub = 80.4 kN
Muxb = -53.53 kNm
Muyb = -17.8 kNm
Vuxb = 10.75 kN
Vuyb = -30.32 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x
Top 71.111 No Beam - 106.667 1.38
400
Sway Condition (as per Stability
= Non Sway
Index)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 85 of 227

Effective Length Factor along Major


= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4800 x 300 x 4994 x 300 x
Top 71.111 33.333 32.038 2.257
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = 37.4 kNm
M2 = -53.53 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = 14.44 kNm
M2 = -17.8 kNm
Min (40, 34 - 12 x (M1/M2)) = 40

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 86 of 227

19.59 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 37.4 - 37.4
Major Axis Mux (bottom) -53.53 - -53.53
Minor Axis Muy (top) 14.44 - 14.44
Minor Axis Muy (bottom) -17.8 - -17.8

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 80.4 kN
Mux = -53.53 kNm
Muy = -17.8 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 361.76 kN
Mux = 63.83 kNm
Muy = 4.39 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 361.76 kN
φ Pn = 361.76 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 87 of 227

Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 18.4 deg
MRes = 56.41 kNm
( φ ) MCap = 128.59 kNm
Capacity Ratio = MRes/ MCap
= 0.439 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 80.4 kN
Muy = 53.53 kNm
Vuy = -30.3158 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 40.87 kNm
φVcy = 87.97 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 115
[15] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 170.47 kN
Mux = 54.45 kNm
Vux = 28.9533 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 27.62 kNm
φVcx = 90.55 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 88 of 227

Vux < φVcx


Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C8
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2118
Critical Analysis Load Combination : 221

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 89 of 227

[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +


Load Combination =
(LOAD 6: EQ +Z -E)
Critical Location = Top Joint
Put = 84.85 kN
Muxt = -15.04 kNm
Muyt = -62.43 kNm
Vuxt = -38.55 kN
Vuyt = 10.01 kN
Pub = 102.92 kN
Muxb = 12.97 kNm
Muyb = 45.49 kNm
Vuxb = -38.55 kN
Vuyb = 10.01 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x
Bottom 76.19 No Beam - 106.667 1.38
400
1500 x 300 x
Top 76.19 No Beam - 71.458 1.066
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
4800 x 300 x 4994 x 300 x
Bottom 76.19 33.333 32.038 2.257
400 400
4994 x 300 x
Top 76.19 No Beam - 21.463 3.544
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 90 of 227

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = 12.97 kNm
M2 = -15.04 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22
M1 = 45.49 kNm
M2 = -62.43 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -15.04 - -15.04
Major Axis Mux (bottom) 12.97 - 12.97
Minor Axis Muy (top) -62.43 - -62.43
Minor Axis Muy (bottom) 45.49 - 45.49

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 91 of 227

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 84.85 kN
Mux = -15.04 kNm
Muy = -62.43 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 127.93 kN
Mux = 47.03 kNm
Muy = -1.43 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 127.93 kN
φ Pn = 127.93 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 76.45 deg
MRes = 64.22 kNm
( φ ) MCap = 129.73 kNm
Capacity Ratio = MRes/ MCap
= 0.495 < 1

Design Of Shear
Design for shear along D

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 92 of 227

Critical Analysis Load Combination : 216


[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 109.86 kN
Muy = 52.45 kNm
Vuy = 35.536 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 35.15 kNm
φVcy = 90.24 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 84.85 kN
Mux = 62.43 kNm
Vux = -38.5527 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 49.07 kNm
φVcx = 88.34 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 93 of 227

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1104
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Top Joint
Put = 338.94 kN
Muxt = 56.76 kNm
Muyt = -72.11 kNm
Vuxt = -50.83 kN
Vuyt = -25.33 kN
Pub = 358.3 kN
Muxb = -19.2 kNm
Muyb = 80.34 kNm
Vuxb = -50.83 kN
Vuyb = -25.33 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 94 of 227

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
5500 x 300 x
Top 71.111 No Beam 29.091 - 5.079
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 4800 x 300 x
Top 71.111 106.667 33.333 1.052
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = -19.2 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 95 of 227

M2 = 56.76 kNm
Min (40, 34 - 12 x (M1/M2)) = 38.06
19.59 < 38.06, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = -72.11 kNm
M2 = 80.34 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 56.76 - 56.76
Major Axis Mux (bottom) -19.2 - -19.2
Minor Axis Muy (top) -72.11 - -72.11
Minor Axis Muy (bottom) 80.34 - 80.34

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 338.94 kN
Mux = 56.76 kNm
Muy = -72.11 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 459.33 kN
Mux = -31.24 kNm
Muy = -72.46 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 96 of 227

Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 459.33 kN
φ Pn = 459.33 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 51.8 deg
MRes = 91.77 kNm
( φ ) MCap = 141.6 kNm
Capacity Ratio = MRes/ MCap
= 0.648 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 411.03 kN
Muy = 86.34 kNm
Vuy = -52.7736 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 21.63 kNm
φVcy = 102.27 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 97 of 227

[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD


Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 243.93 kN
Mux = 79.38 kNm
Vux = -49.3402 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 40.97 kNm
φVcx = 91.86 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 98 of 227

Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2104
Critical Analysis Load Combination : 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint
Put = 132.26 kN
Muxt = 72.65 kNm
Muyt = 18.8 kNm
Vuxt = 29.77 kN
Vuyt = -60.41 kN
Pub = 150.33 kN
Muxb = -96.46 kNm
Muyb = -64.54 kNm
Vuxb = 29.77 kN
Vuyb = -60.41 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
5500 x 300 x
Bottom 76.19 No Beam 29.091 - 5.079
400
5500 x 300 x
Top 76.19 No Beam 19.489 - 5.143
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 99 of 227

Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x 4800 x 300 x
Bottom 76.19 106.667 33.333 1.052
400 400
4800 x 300 x
Top 76.19 No Beam - 22.331 4.508
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = 72.65 kNm
M2 = -96.46 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22
M1 = 18.8 kNm
M2 = -64.54 kNm
Min (40, 34 - 12 x (M1/M2)) = 37.5
21.22 < 37.5, Column not slender along B

Calculation of Design Moment

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 100 of 227

Direction Manalysis Msldr or Mc Mdesign-final


A B C
Major Axis Mux (top) 72.65 - 72.65
Major Axis Mux (bottom) -96.46 - -96.46
Minor Axis Muy (top) 18.8 - 18.8
Minor Axis Muy (bottom) -64.54 - -64.54

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 150.33 kN
Mux = -96.46 kNm
Muy = -64.54 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 181.84 kN
Mux = -78.59 kNm
Muy = 67.05 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 181.84 kN
φ Pn = 181.84 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 101 of 227

Moment Capacity Check


Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 33.79 deg
MRes = 116.06 kNm
( φ ) MCap = 133.66 kNm
Capacity Ratio = MRes/ MCap
= 0.868 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 173.13 kN
Muy = 114.76 kNm
Vuy = -71.8094 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 87.5 kNm
φVcy = 88.63 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 163.77 kN
Mux = 66.26 kNm
Vux = -47.6261 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 40.48 kNm
φVcx = 91.63 kN
Vux < φVcx
Link For Shear Design Along B are not required

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 102 of 227

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C9
Level : 5.8m To 8.6m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 3102
Critical Analysis Load Combination : 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 4: EQ -X -E)
Critical Location = Top Joint
Put = 18.8 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 103 of 227

Muxt = 16.46 kNm


Muyt = -4.18 kNm
Vuxt = -4.36 kN
Vuyt = -10.79 kN
Pub = 28.96 kN
Muxb = -13.73 kNm
Muyb = 8.04 kNm
Vuxb = -4.36 kN
Vuyb = -10.79 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 5.143
5600 x 200 x
Top 24.107 No Beam 8.036 - 3.013
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 4.508
4900 x 200 x
Top 24.107 No Beam - 9.184 2.606
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 104 of 227

Along B
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 86.6 mm
Kluy /r = 28.87
M1 = -13.73 kNm
M2 = 16.46 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 86.6 mm
Klux /r = 28.87
M1 = -4.18 kNm
M2 = 8.04 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 16.46 - 16.46
Major Axis Mux (bottom) -13.73 - -13.73
Minor Axis Muy (top) -4.18 - -4.18
Minor Axis Muy (bottom) 8.04 - 8.04

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 18.8 kN
Mux = 16.46 kNm
Muy = -4.18 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 105 of 227

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 30.7 kN
Mux = -12.45 kNm
Muy = 8.91 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 30.7 kN
φ Pn = 30.7 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 14.25 deg
MRes = 16.98 kNm
( φ ) MCap = 51.57 kNm
Capacity Ratio = MRes/ MCap
= 0.329 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 18.84 kN
Muy = 16.13 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 106 of 227

Vuy = -11.0293 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 13.87 kNm
φVcy = 46.08 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 20.53 kN
Mux = 12.87 kNm
Vux = -7.7805 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 10.41 kNm
φVcx = 45.92 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 107 of 227

Spacing 300 --- --- 300 ---

General Data
Column No. : C10
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1112
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Top Joint
Put = 456.92 kN
Muxt = -30.35 kNm
Muyt = -64.75 kNm
Vuxt = -44.79 kN
Vuyt = 17.71 kN
Pub = 476.28 kN
Muxb = 22.78 kNm
Muyb = 69.59 kNm
Vuxb = -44.79 kN
Vuyb = 17.71 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 108 of 227

Width x Depth) Width x Depth)


N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3400 x 300 x 5500 x 300 x
Top 71.111 47.059 29.091 1.932
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 4800 x 300 x
Top 71.111 106.667 33.333 1.052
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = 22.78 kNm
M2 = -30.35 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 109 of 227

K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = -64.75 kNm
M2 = 69.59 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -30.35 - -30.35
Major Axis Mux (bottom) 22.78 - 22.78
Minor Axis Muy (top) -64.75 - -64.75
Minor Axis Muy (bottom) 69.59 - 69.59

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 456.92 kN
Mux = -30.35 kNm
Muy = -64.75 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 556.78 kN
Mux = 7.14 kNm
Muy = -59.31 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 110 of 227

[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD


Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 556.78 kN
φ Pn = 556.78 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 64.89 deg
MRes = 71.51 kNm
( φ ) MCap = 152.34 kNm
Capacity Ratio = MRes/ MCap
= 0.469 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 109
[9] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10:
Critical Load Combination = kN
LL) +(LOAD 1: EQ +X +E)
Nu = 362.88 kN
Muy = 61.79 kNm
Vuy = 39.1348 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 4.66 kNm
φVcy = 152.47 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 333.97 kN
Mux = 68.32 kNm
Vux = -43.0481 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 111 of 227

λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 15.74 kNm
φVcx = 104.76 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C10
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 112 of 227

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2111
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint
Put = 231.32 kN
Muxt = -32.61 kNm
Muyt = -70.48 kNm
Vuxt = -50.56 kN
Vuyt = 24.58 kN
Pub = 249.39 kN
Muxb = 36.2 kNm
Muyb = 71.04 kNm
Vuxb = -50.56 kN
Vuyb = 24.58 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
3400 x 300 x 5500 x 300 x
Bottom 76.19 47.059 29.091 1.932
400 400
3400 x 300 x 5500 x 300 x
Top 76.19 31.526 19.489 1.967
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x 4800 x 300 x
Bottom 76.19 106.667 33.333 1.052
400 400
4800 x 300 x

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 113 of 227

Top 76.19 No Beam 350 - 22.331 4.508


Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 115.47 mm
Kluy /r = 21.22
M1 = -32.61 kNm
M2 = 36.2 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22
M1 = -70.48 kNm
M2 = 71.04 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -32.61 - -32.61
Major Axis Mux (bottom) 36.2 - 36.2
Minor Axis Muy (top) -70.48 - -70.48
Minor Axis Muy (bottom) 71.04 - 71.04

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 114 of 227

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 249.39 kN
Mux = 36.2 kNm
Muy = 71.04 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Critical Location = Bottom Joint kN
Pu = 251.34 kN
Mux = 26.74 kNm
Muy = 71.25 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Pu = 251.34 kN
φ Pn = 251.34 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 63 deg
MRes = 79.73 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 115 of 227

( φ ) MCap = 142.85 kNm


Capacity Ratio = MRes/ MCap
= 0.558 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 224.05 kN
Muy = 64.15 kNm
Vuy = 43.6137 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 28.88 kNm
φVcy = 94.44 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 231.32 kN
Mux = 70.48 kNm
Vux = -50.5579 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 34.06 kNm
φVcx = 94.22 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 116 of 227

Criterion for spacing of normal links


Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C10
Level : 5.8m To 8.6m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 3104
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 24.75 kN
Muxt = -16.47 kNm
Muyt = -8.62 kNm
Vuxt = -7.24 kN
Vuyt = 11.41 kN
Pub = 34.91 kN
Muxb = 15.46 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 117 of 227

Muyb = 11.66 kNm


Vuxb = -7.24 kN
Vuyb = 11.41 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1.967
3500 x 200 x 5600 x 200 x
Top 24.107 12.857 8.036 1.148
300 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 4.508
4900 x 200 x
Top 24.107 No Beam - 9.184 2.606
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 118 of 227

Column Is Braced Along D


Slenderness Check along D
K = 1
r = 86.6 mm
Kluy /r = 28.87
M1 = 15.46 kNm
M2 = -16.47 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 86.6 mm
Klux /r = 28.87
M1 = -8.62 kNm
M2 = 11.66 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -16.47 - -16.47
Major Axis Mux (bottom) 15.46 - 15.46
Minor Axis Muy (top) -8.62 - -8.62
Minor Axis Muy (bottom) 11.66 - 11.66

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 34.91 kN
Mux = 15.46 kNm
Muy = 11.66 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 119 of 227

Critical Location = Bottom Joint kN


Pu = 40.25 kN
Mux = 7.1 kNm
Muy = 15.68 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Pu = 40.25 kN
φ Pn = 40.25 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 37.03 deg
MRes = 19.36 kNm
( φ ) MCap = 52.9 kNm
Capacity Ratio = MRes/ MCap
= 0.366 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 24.6 kN
Muy = 17.32 kNm
Vuy = 11.6646 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 14.37 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 120 of 227

φVcy = 46.14 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 30.08 kN
Mux = 17.57 kNm
Vux = -11.879 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 13.96 kNm
φVcx = 46.28 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C11

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 121 of 227

Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1117
Critical Analysis Load Combination : 114
[14] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 6: EQ +Z -E)
Critical Location = Bottom Joint
Put = 202.36 kN
Muxt = -11.57 kNm
Muyt = -62.14 kNm
Vuxt = -43.09 kN
Vuyt = 7.03 kN
Pub = 216.19 kN
Muxb = 9.52 kNm
Muyb = 67.09 kNm
Vuxb = -43.09 kN
Vuyb = 7.03 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 3400 x 300 x
Top 71.111 106.667 47.059 0.958
400 400
Sway Condition (as per Stability
= Non Sway
Index)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 122 of 227

Effective Length Factor along Major


= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 4800 x 300 x
Top 71.111 106.667 33.333 1.052
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 115.47 mm
Kluy /r = 17.34
M1 = 9.52 kNm
M2 = -11.57 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
17.34 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = -62.14 kNm
M2 = 67.09 kNm
Min (40, 34 - 12 x (M1/M2)) = 40

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 123 of 227

19.59 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -11.57 - -11.57
Major Axis Mux (bottom) 9.52 - 9.52
Minor Axis Muy (top) -62.14 - -62.14
Minor Axis Muy (bottom) 67.09 - 67.09

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 216.19 kN
Mux = 9.52 kNm
Muy = 67.09 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint kN
Pu = 400.49 kN
Mux = 5.89 kNm
Muy = -52.94 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Pu = 400.49 kN
φ Pn = 400.49 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 124 of 227

Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 81.92 deg
MRes = 67.76 kNm
( φ ) MCap = 146.29 kNm
Capacity Ratio = MRes/ MCap
= 0.463 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 109
[9] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10:
Critical Load Combination = kN
LL) +(LOAD 1: EQ +X +E)
Nu = 235.77 kN
Muy = 60.12 kNm
Vuy = 37.4185 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 23 kNm
φVcy = 95.43 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 114
[14] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 216.19 kN
Mux = 67.09 kNm
Vux = -43.0865 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 33.05 kNm
φVcx = 92.7 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 125 of 227

Vux < φVcx


Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C11
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2115
Critical Analysis Load Combination : 221

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 126 of 227

[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +


Load Combination =
(LOAD 6: EQ +Z -E)
Critical Location = Bottom Joint
Put = 125.73 kN
Muxt = -17.52 kNm
Muyt = -68.7 kNm
Vuxt = -52.54 kN
Vuyt = 10.95 kN
Pub = 143.8 kN
Muxb = 13.14 kNm
Muyb = 78.38 kNm
Vuxb = -52.54 kN
Vuyb = 10.95 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x 3400 x 300 x
Bottom 76.19 106.667 47.059 0.958
400 400
3400 x 300 x
Top 76.19 No Beam - 31.526 3.184
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.86
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
1500 x 300 x 4800 x 300 x
Bottom 76.19 106.667 33.333 1.052
400 400
4800 x 300 x
Top 76.19 No Beam - 22.331 4.508
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 127 of 227

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.86
r = 115.47 mm
Kluy /r = 18.25
M1 = 13.14 kNm
M2 = -17.52 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
18.25 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 115.47 mm
Klux /r = 21.22
M1 = -68.7 kNm
M2 = 78.38 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.22 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -17.52 - -17.52
Major Axis Mux (bottom) 13.14 - 13.14
Minor Axis Muy (top) -68.7 - -68.7
Minor Axis Muy (bottom) 78.38 - 78.38

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 128 of 227

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 143.8 kN
Mux = 13.14 kNm
Muy = 78.38 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 147.01 kN
Mux = 52.97 kNm
Muy = 19.2 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 147.01 kN
φ Pn = 147.01 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 80.48 deg
MRes = 79.47 kNm
( φ ) MCap = 136.89 kNm
Capacity Ratio = MRes/ MCap
= 0.581 < 1

Design Of Shear
Design for shear along D

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 129 of 227

Critical Analysis Load Combination : 216


[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 147.01 kN
Muy = 52.97 kNm
Vuy = 35.5137 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 29.82 kNm
φVcy = 91.75 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 143.8 kN
Mux = 78.38 kNm
Vux = -52.5424 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 55.74 kNm
φVcx = 89.66 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 130 of 227

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C11
Level : 5.8m To 8.6m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 3106
Critical Analysis Load Combination : 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 6: EQ +Z -E)
Critical Location = Top Joint
Put = 15.35 kN
Muxt = -3.98 kNm
Muyt = -13.38 kNm
Vuxt = -8.23 kN
Vuyt = 3.5 kN
Pub = 25.51 kN
Muxb = 5.81 kNm
Muyb = 9.65 kNm
Vuxb = -8.23 kN
Vuyb = 3.5 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 131 of 227

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 3.184
3500 x 200 x
Top 24.107 No Beam - 12.857 1.891
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 1
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 4.508
4900 x 200 x
Top 24.107 No Beam - 9.184 2.606
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 1
axis

Check For Stability Index


Along D
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.003
0.003< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 1
r = 86.6 mm
Kluy /r = 28.87
M1 = -3.98 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 132 of 227

M2 = 5.81 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 1
r = 86.6 mm
Klux /r = 28.87
M1 = 9.65 kNm
M2 = -13.38 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
28.87 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -3.98 - -3.98
Major Axis Mux (bottom) 5.81 - 5.81
Minor Axis Muy (top) -13.38 - -13.38
Minor Axis Muy (bottom) 9.65 - 9.65

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 15.35 kN
Mux = -3.98 kNm
Muy = -13.38 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 26.05 kN
Mux = 10.53 kNm
Muy = 8.57 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 133 of 227

Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 26.05 kN
φ Pn = 26.05 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 73.42 deg
MRes = 13.96 kNm
( φ ) MCap = 51.53 kNm
Capacity Ratio = MRes/ MCap
= 0.271 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 15.89 kN
Muy = 11.19 kNm
Vuy = 7.7589 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 9.28 kNm
φVcy = 46.23 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 221

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 134 of 227

[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD


Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 15.35 kN
Mux = 13.38 kNm
Vux = -8.2262 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 11.53 kNm
φVcx = 45.8 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C12
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 135 of 227

Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2650 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1101
Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 3: EQ -X +E)
Critical Location = Top Joint
Put = 93.91 kN
Muxt = 35.33 kNm
Muyt = 1.08 kNm
Vuxt = -0.4 kN
Vuyt = -22.81 kN
Pub = 104.8 kN
Muxb = -33.08 kNm
Muyb = 2.29 kNm
Vuxb = -0.4 kN
Vuyb = -22.81 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
5909.85 x 300
Top 22.5 No Beam 18.137 - 0.402
x 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.71
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 136 of 227

(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
2786 x 300 x
Top 22.5 No Beam 57.43 - 1.139
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.71
r = 86.6 mm
Kluy /r = 21.73
M1 = -33.08 kNm
M2 = 35.33 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.73 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 86.6 mm
Klux /r = 26.12
M1 = 1.08 kNm
M2 = 2.29 kNm
Min (40, 34 - 12 x (M1/M2)) = 28.31
26.12 < 28.31, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 137 of 227

Major Axis Mux (top) 35.33 - 35.33


Major Axis Mux (bottom) -33.08 - -33.08
Minor Axis Muy (top) 1.08 - 1.08
Minor Axis Muy (bottom) 2.29 - 2.29

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 93.91 kN
Mux = 35.33 kNm
Muy = 1.08 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 153.49 kN
Mux = -1.23 kNm
Muy = -32.16 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 153.49 kN
φ Pn = 153.49 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 138 of 227

Reinforcement Provided = 4-#19


Load Angle = Tan-1(Muy/Mux)
= 1.76 deg
MRes = 35.35 kNm
( φ ) MCap = 57.65 kNm
Capacity Ratio = MRes/ MCap
= 0.613 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 93.91 kN
Muy = 35.33 kNm
Vuy = -22.8108 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 24.07 kNm
φVcy = 46.62 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 142.6 kN
Mux = 33.04 kNm
Vux = 21.7405 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 15.94 kNm
φVcx = 48.08 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 139 of 227

Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C13
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 3000 mm
Clear Floor Height @ luy = 2650 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1109
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Bottom Joint
Put = 76.98 kN
Muxt = -24.31 kNm
Muyt = -0.33 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 140 of 227

Vuxt = 0.05 kN
Vuyt = 17.87 kN
Pub = 84.76 kN
Muxb = 29.29 kNm
Muyb = -0.49 kNm
Vuxb = 0.05 kN
Vuyb = 17.87 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
5709.54 x 300 5909.85 x 300
Top 22.5 18.773 18.137 0.608
x 350 x 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.74
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
Top 22.5 No Beam No Beam - - 1
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.78
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 141 of 227

0.009< 0.05, Column shall be designed as non-sway frame


(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.74
r = 86.6 mm
Kluy /r = 22.64
M1 = -24.31 kNm
M2 = 29.29 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
22.64 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.78
r = 86.6 mm
Klux /r = 27.02
M1 = -0.33 kNm
M2 = -0.49 kNm
Min (40, 34 - 12 x (M1/M2)) = 25.97
27.02 > 25.97, Column slender along B
Moment Magnification:
For Non-sway frame:
Along B
βdns = 0.6
Ec = 23500 N/sqmm
9 = 0.675 mm^4
Ig ( x 10 )
EI ( x 10 6) = 4579107.188 N-sqmm
M2min = 2.03 kNm
Cm = 1
Pc = 8253.7 kN
δns = 1.01
Mc1 = -2.06 kNm
1.4 MuyB = -0.68 kNm
Mc1 = Min (-2.06, -0.68) kNm
= -0.68 kNm
Mc2 = -2.06 kNm
1.4 MuyT = -0.46 kNm
Mc2 = Min (-2.06, -0.46) kNm
= -0.46 kNm

Calculation of Design Moment

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 142 of 227

Direction Manalysis Msldr or Mc Mdesign-final


A B C
Major Axis Mux (top) -24.31 - -24.31
Major Axis Mux (bottom) 29.29 - 29.29
Minor Axis Muy (top) -0.33 -0.46 -0.46
Minor Axis Muy (bottom) -0.49 -0.68 -0.68

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 84.76 kN
Mux = 29.29 kNm
Muy = -0.68 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN
Pu = 119.14 kN
Mux = -25.57 kNm
Muy = -1.35 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Pu = 119.14 kN
φ Pn = 119.14 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 143 of 227

Moment Capacity Check


Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 1.34 deg
MRes = 29.3 kNm
( φ ) MCap = 56.8 kNm
Capacity Ratio = MRes/ MCap
= 0.516 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 84.76 kN
Muy = 29.29 kNm
Vuy = 17.8709 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 19.13 kNm
φVcy = 46.57 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 115
[15] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 85.08 kN
Mux = 15.94 kNm
Vux = 7.1636 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 5.74 kNm
φVcx = 47.68 kN
Vux < φVcx
Link For Shear Design Along B are not required

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 144 of 227

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C14
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2650 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1119
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Top Joint
Put = 67.21 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 145 of 227

Muxt = -36.66 kNm


Muyt = -0.78 kNm
Vuxt = -1.21 kN
Vuyt = 24.04 kN
Pub = 78.1 kN
Muxb = 35.44 kNm
Muyb = 2.85 kNm
Vuxb = -1.21 kN
Vuyb = 24.04 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
5709.54 x 300
Top 22.5 No Beam - 18.773 0.489
x 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.72
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
2265 x 300 x
Top 22.5 No Beam 47.323 - 1.125
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 146 of 227

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.72
r = 86.6 mm
Kluy /r = 22.03
M1 = 35.44 kNm
M2 = -36.66 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
22.03 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 86.6 mm
Klux /r = 26.62
M1 = -0.78 kNm
M2 = 2.85 kNm
Min (40, 34 - 12 x (M1/M2)) = 37.26
26.62 < 37.26, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -36.66 - -36.66
Major Axis Mux (bottom) 35.44 - 35.44
Minor Axis Muy (top) -0.78 - -0.78
Minor Axis Muy (bottom) 2.85 - 2.85

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 67.21 kN
Mux = -36.66 kNm
Muy = -0.78 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 147 of 227

Φ Pn, Max Check


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint kN
Pu = 114.61 kN
Mux = 11.74 kNm
Muy = -26.01 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Pu = 114.61 kN
φ Pn = 114.61 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 1.21 deg
MRes = 36.67 kNm
( φ ) MCap = 55.16 kNm
Capacity Ratio = MRes/ MCap
= 0.665 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 67.21 kN
Muy = 36.66 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 148 of 227

Vuy = 24.0401 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 28.6 kNm
φVcy = 46.24 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 230
[58] : 1.38 (LOAD 9: DL) +(LOAD 7:
Critical Load Combination = kN
EQ -Z +E)
Nu = 92.62 kN
Mux = 27.07 kNm
Vux = 17.6015 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 15.96 kNm
φVcx = 47.16 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 149 of 227

Spacing 300 --- --- 300 ---

General Data
Column No. : C15
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1107
Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 3: EQ -X +E)
Critical Location = Top Joint
Put = 671.99 kN
Muxt = 109.59 kNm
Muyt = -6.13 kNm
Vuxt = -4.59 kN
Vuyt = -68.86 kN
Pub = 691.35 kN
Muxb = -96.94 kNm
Muyb = 7.63 kNm
Vuxb = -4.59 kN
Vuyb = -68.86 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 150 of 227

Width x Depth) Width x Depth)


N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3100 x 300 x 2000 x 300 x
Top 71.111 51.613 80 0.541
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.73
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
4994 x 300 x 450 x 300 x
Top 71.111 32.038 238.194 0.263
400 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.69
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.73
r = 115.47 mm
Kluy /r = 16.44
M1 = -96.94 kNm
M2 = 109.59 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.44 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 151 of 227

K = 0.69
r = 115.47 mm
Klux /r = 15.84
M1 = -6.13 kNm
M2 = 7.63 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
15.84 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 109.59 - 109.59
Major Axis Mux (bottom) -96.94 - -96.94
Minor Axis Muy (top) -6.13 - -6.13
Minor Axis Muy (bottom) 7.63 - 7.63

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 671.99 kN
Mux = 109.59 kNm
Muy = -6.13 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint kN
Pu = 704.8 kN
Mux = -10.74 kNm
Muy = -58.72 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 222

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 152 of 227

[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD


Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Pu = 704.8 kN
φ Pn = 704.8 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 3.2 deg
MRes = 109.76 kNm
( φ ) MCap = 180.97 kNm
Capacity Ratio = MRes/ MCap
= 0.607 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 486.84 kN
Muy = 98.99 kNm
Vuy = -63.9214 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 22.35 kNm
φVcy = 105.82 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 458.07 kN
Mux = 24.29 kNm
Vux = -26.4527 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 153 of 227

λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -47.83 kNm
φVcx = 200.38 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C16
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 154 of 227

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1108
Critical Analysis Load Combination : 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 4: EQ -X -E)
Critical Location = Top Joint
Put = 562.24 kN
Muxt = 85.51 kNm
Muyt = 12.6 kNm
Vuxt = 6.08 kN
Vuyt = -53.48 kN
Pub = 581.6 kN
Muxb = -74.89 kNm
Muyb = -5.63 kNm
Vuxb = 6.08 kN
Vuyb = -53.48 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3100 x 300 x 2000 x 300 x
Top 71.111 51.613 80 0.541
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.73
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
5000 x 300 x 4994 x 300 x
Top 71.111 32 32.038 1.111
400 400

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 155 of 227

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.73
r = 115.47 mm
Kluy /r = 16.44
M1 = -74.89 kNm
M2 = 85.51 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.44 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 19.59
M1 = -5.63 kNm
M2 = 12.6 kNm
Min (40, 34 - 12 x (M1/M2)) = 39.36
19.59 < 39.36, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 85.51 - 85.51
Major Axis Mux (bottom) -74.89 - -74.89
Minor Axis Muy (top) 12.6 - 12.6
Minor Axis Muy (bottom) -5.63 - -5.63

Where

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 156 of 227

A = Moments from analysis


B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 562.24 kN
Mux = 85.51 kNm
Muy = 12.6 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 594.93 kN
Mux = -14.45 kNm
Muy = 55.81 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 594.93 kN
φ Pn = 594.93 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 8.38 deg
MRes = 86.44 kNm
( φ ) MCap = 172.3 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 157 of 227

Capacity Ratio = MRes/ MCap


= 0.502 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 111
[11] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 408.45 kN
Muy = 79.07 kNm
Vuy = -50.9081 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 14.77 kNm
φVcy = 110.76 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 116
[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 404.15 kN
Mux = 74.25 kNm
Vux = 44.0307 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 10.62 kNm
φVcx = 116.64 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 158 of 227

Min. Longitudinal Bar dia X 16 = 256 mm


48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C17
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1122
Critical Analysis Load Combination : 114
[14] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 6: EQ +Z -E)
Critical Location = Bottom Joint
Put = 35.18 kN
Muxt = -10.19 kNm
Muyt = -62.29 kNm
Vuxt = -42.89 kN
Vuyt = 6.35 kN
Pub = 49.01 kN
Muxb = 8.86 kNm
Muyb = 66.35 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 159 of 227

Vuxb = -42.89 kN
Vuyb = 6.35 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x
Top 71.111 No Beam - 106.667 0.666
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.74
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 4800 x 300 x
Top 71.111 106.667 33.333 0.508
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.72
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 160 of 227

Slenderness Check along D


K = 0.74
r = 115.47 mm
Kluy /r = 16.66
M1 = 8.86 kNm
M2 = -10.19 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.66 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.72
r = 115.47 mm
Klux /r = 16.21
M1 = -62.29 kNm
M2 = 66.35 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.21 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -10.19 - -10.19
Major Axis Mux (bottom) 8.86 - 8.86
Minor Axis Muy (top) -62.29 - -62.29
Minor Axis Muy (bottom) 66.35 - 66.35

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 49.01 kN
Mux = 8.86 kNm
Muy = 66.35 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 161 of 227

Pu = 168.24 kN
Mux = 63.13 kNm
Muy = 9.01 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 168.24 kN
φ Pn = 168.24 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 82.4 deg
MRes = 66.94 kNm
( φ ) MCap = 124.27 kNm
Capacity Ratio = MRes/ MCap
= 0.539 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 168.24 kN
Muy = 63.13 kNm
Vuy = 40.0092 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 36.64 kNm
φVcy = 90.92 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 162 of 227

Vuy < φVcy


Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 62.22 kN
Mux = 64.67 kNm
Vux = -43.8857 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 54.87 kNm
φVcx = 88.46 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C18
Level : 0m To 3m

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 163 of 227

Design Code = ACI 318M - 2011


Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1105
Critical Analysis Load Combination : 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 8: EQ -Z -E)
Critical Location = Top Joint
Put = 80.83 kN
Muxt = 57.05 kNm
Muyt = 75.28 kNm
Vuxt = 53.94 kN
Vuyt = -29.94 kN
Pub = 100.19 kN
Muxb = -32.74 kNm
Muyb = -86.51 kNm
Vuxb = 53.94 kN
Vuyb = -29.94 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
5500 x 300 x
Top 71.111 No Beam 29.091 - 2.452
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 164 of 227

Axis = 0.87

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3900 x 300 x 1500 x 300 x
Top 71.111 27.484 106.667 0.53
350 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.73
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 19.59
M1 = -32.74 kNm
M2 = 57.05 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.59 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.73
r = 115.47 mm
Klux /r = 16.75
M1 = 75.28 kNm
M2 = -86.51 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.75 < 40, Column not slender along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 165 of 227

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 57.05 - 57.05
Major Axis Mux (bottom) -32.74 - -32.74
Minor Axis Muy (top) 75.28 - 75.28
Minor Axis Muy (bottom) -86.51 - -86.51

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 80.83 kN
Mux = 57.05 kNm
Muy = 75.28 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 238.75 kN
Mux = -10.38 kNm
Muy = 78.09 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 238.75 kN
φ Pn = 238.75 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 166 of 227

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 52.84 deg
MRes = 94.45 kNm
( φ ) MCap = 128.37 kNm
Capacity Ratio = MRes/ MCap
= 0.736 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 163.07 kN
Muy = 84.42 kNm
Vuy = -51.4137 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 58.74 kNm
φVcy = 89.09 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 231
[59] : 1.38 (LOAD 9: DL) +(LOAD 8:
Critical Load Combination = kN
EQ -Z -E)
Nu = 65.27 kN
Mux = 86.08 kNm
Vux = 53.6539 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 75.8 kNm
φVcx = 87.68 kN
Vux < φVcx

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 167 of 227

Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C19
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1113
Critical Analysis Load Combination : 116
[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 168 of 227

Load Combination = (LOAD 8: EQ -Z -E)


Critical Location = Bottom Joint
Put = 97.92 kN
Muxt = 0.22 kNm
Muyt = 63.06 kNm
Vuxt = 45.12 kN
Vuyt = -2.09 kN
Pub = 111.75 kN
Muxb = -6.04 kNm
Muyb = -72.25 kNm
Vuxb = 45.12 kN
Vuyb = -2.09 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3400 x 300 x 5500 x 300 x
Top 71.111 47.059 29.091 0.933
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.77
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
3900 x 300 x 1500 x 300 x
Top 71.111 27.484 106.667 0.53
350 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.73
axis

Check For Stability Index


Along D

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 169 of 227

Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.77
r = 115.47 mm
Kluy /r = 17.34
M1 = 0.22 kNm
M2 = -6.04 kNm
Min (40, 34 - 12 x (M1/M2)) = 34.44
17.34 < 34.44, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.73
r = 115.47 mm
Klux /r = 16.75
M1 = 63.06 kNm
M2 = -72.25 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.75 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 0.22 - 0.22
Major Axis Mux (bottom) -6.04 - -6.04
Minor Axis Muy (top) 63.06 - 63.06
Minor Axis Muy (bottom) -72.25 - -72.25

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 170 of 227

Critical Case - Axial Load & BiAxial Bending


Pu = 111.75 kN
Mux = -6.04 kNm
Muy = -72.25 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 298.18 kN
Mux = 23.77 kNm
Muy = 65.37 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 298.18 kN
φ Pn = 298.18 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 85.22 deg
MRes = 72.5 kNm
( φ ) MCap = 132.45 kNm
Capacity Ratio = MRes/ MCap
= 0.547 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 224

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 171 of 227

[52] : 1.38 (LOAD 9: DL) +(LOAD 1:


Critical Load Combination = kN
EQ +X +E)
Nu = 183.53 kN
Muy = 61.61 kNm
Vuy = 39.855 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 32.72 kNm
φVcy = 91.98 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 231
[59] : 1.38 (LOAD 9: DL) +(LOAD 8:
Critical Load Combination = kN
EQ -Z -E)
Nu = 121.19 kN
Mux = 72.75 kNm
Vux = 45.3441 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 53.67 kNm
φVcx = 88.84 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 172 of 227

Note: Ductile Design of Links is Applicable Only For Boundary Elements


Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C20
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2600 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1118
Critical Analysis Load Combination : 230
Load Combination = [58] : 1.38 (LOAD 9: DL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint
Put = -9.21 kN
Muxt = -4.07 kNm
Muyt = 51.84 kNm
Vuxt = 38.99 kN
Vuyt = 1.73 kN
Pub = 6.69 kN
Muxb = 1.12 kNm
Muyb = -65.1 kNm
Vuxb = 38.99 kN
Vuyb = 1.73 kN

Effective Length Calculation

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 173 of 227

Calculation Along Major Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x 3400 x 300 x
Top 71.111 106.667 47.059 0.463
400 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.72
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x
Top 71.111 No Beam - 106.667 0.666
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.74
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.72
r = 115.47 mm
Kluy /r = 16.21
M1 = 0 kNm
M2 = 0 kNm
Min (40, 34 - 12 x (M1/M2)) = 0

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 174 of 227

16.21 > 0,Column slender along D


Column Is Braced Along B
Slenderness Check along B
K = 0.74
r = 115.47 mm
Klux /r = 16.66
M1 = 0 kNm
M2 = 0 kNm
Min (40, 34 - 12 x (M1/M2)) = 0
16.66 > 0, Column slender along B
Moment Magnification:

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -4.07 - -4.07
Major Axis Mux (bottom) 1.12 - 1.12
Minor Axis Muy (top) 51.84 - 51.84
Minor Axis Muy (bottom) -65.1 - -65.1

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 6.69 kN
Mux = 1.12 kNm
Muy = -65.1 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Critical Location = Bottom Joint kN
Pu = 158.33 kN
Mux = 13.34 kNm
Muy = 64.33 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 175 of 227

Minimum Ast Calculation


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Pu = 158.33 kN
φ Pn = 158.33 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 89.02 deg
MRes = 65.11 kNm
( φ ) MCap = 117.37 kNm
Capacity Ratio = MRes/ MCap
= 0.555 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 64.13 kN
Muy = 63.26 kNm
Vuy = 41.105 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 53.16 kNm
φVcy = 88.23 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 230
[58] : 1.38 (LOAD 9: DL) +(LOAD 7:

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 176 of 227

Critical Load Combination = EQ -Z +E) kN


Nu = 6.69 kN
Mux = 65.1 kNm
Vux = 38.9888 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 64.04 kNm
φVcx = 86.85 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C21
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 177 of 227

Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2600 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1123
Critical Analysis Load Combination : 230
Load Combination = [58] : 1.38 (LOAD 9: DL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint
Put = 4.9 kN
Muxt = -0.72 kNm
Muyt = 61.87 kNm
Vuxt = 43.63 kN
Vuyt = 0.07 kN
Pub = 20.8 kN
Muxb = -0.5 kNm
Muyb = -68.99 kNm
Vuxb = 43.63 kN
Vuyb = 0.07 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 71.111 No Beam No Beam - - 1
1500 x 300 x
Top 71.111 No Beam - 106.667 0.666
400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.74
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 178 of 227

Bottom 71.111 No Beam No Beam - - 1


3900 x 300 x 1500 x 300 x
Top 71.111 27.484 106.667 0.53
350 400
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.73
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.74
r = 115.47 mm
Kluy /r = 16.66
M1 = -0.5 kNm
M2 = -0.72 kNm
Min (40, 34 - 12 x (M1/M2)) = 25.67
16.66 < 25.67, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.73
r = 115.47 mm
Klux /r = 16.75
M1 = 61.87 kNm
M2 = -68.99 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.75 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -0.72 - -0.72
Major Axis Mux (bottom) -0.5 - -0.5
Minor Axis Muy (top) 61.87 - 61.87

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 179 of 227

Minor Axis Muy (bottom) -68.99 - -68.99

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 20.8 kN
Mux = -0.5 kNm
Muy = -68.99 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 131.85 kN
Mux = 19.37 kNm
Muy = 51.42 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 131.85 kN
φ Pn = 131.85 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 180 of 227

= 89.59 deg
MRes = 68.99 kNm
( φ ) MCap = 119.34 kNm
Capacity Ratio = MRes/ MCap
= 0.578 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 129.99 kN
Muy = 59.2 kNm
Vuy = 36.9421 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 38.73 kNm
φVcy = 89.75 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 38.86 kN
Mux = 70.01 kNm
Vux = 44.5227 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 63.89 kNm
φVcx = 87.59 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 181 of 227

> Max. longitudinal bar dia / 4


= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C22
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 3000 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1106
Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint
Put = 31.68 kN
Muxt = 0.74 kNm
Muyt = -26.31 kNm
Vuxt = -17.98 kN
Vuyt = 1.2 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 182 of 227

Pub = 39.46 kN
Muxb = 4.34 kNm
Muyb = 27.62 kNm
Vuxb = -17.98 kN
Vuyb = 1.2 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
Top 22.5 No Beam No Beam - - 1
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.78
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
3900 x 300 x
Top 22.5 No Beam - 27.484 0.818
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.76
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 183 of 227

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.78
r = 86.6 mm
Kluy /r = 27.02
M1 = 0.74 kNm
M2 = 4.34 kNm
Min (40, 34 - 12 x (M1/M2)) = 31.96
27.02 < 31.96, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.76
r = 86.6 mm
Klux /r = 23.26
M1 = -26.31 kNm
M2 = 27.62 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
23.26 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 0.74 - 0.74
Major Axis Mux (bottom) 4.34 - 4.34
Minor Axis Muy (top) -26.31 - -26.31
Minor Axis Muy (bottom) 27.62 - 27.62

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 39.46 kN
Mux = 4.34 kNm
Muy = 27.62 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
Load Combination = [48] : 1.68 (LOAD 9: DL) +0.5 (LOAD

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 184 of 227

10: LL) +(LOAD 5: EQ +Z +E)


Critical Location = Bottom Joint kN
Pu = 51.51 kN
Mux = 4.22 kNm
Muy = 27.98 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 51.51 kN
φ Pn = 51.51 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 81.06 deg
MRes = 27.96 kNm
( φ ) MCap = 52.95 kNm
Capacity Ratio = MRes/ MCap
= 0.528 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 112
[12] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 31.18 kN
Muy = 10.39 kNm
Vuy = -4.6699 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 185 of 227

Mm = 6.65 kNm
φVcy = 45.76 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 40.62 kN
Mux = 27.52 kNm
Vux = -18.5059 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 22.65 kNm
φVcx = 46.16 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 186 of 227

General Data
Column No. : C23
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2650 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 1114
Critical Analysis Load Combination : 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 6: EQ +Z -E)
Critical Location = Top Joint
Put = 84.67 kN
Muxt = 16.54 kNm
Muyt = -23.73 kNm
Vuxt = -15.83 kN
Vuyt = -7.47 kN
Pub = 95.56 kN
Muxb = -5.85 kNm
Muyb = 23.75 kNm
Vuxb = -15.83 kN
Vuyb = -7.47 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
5400 x 300 x
Top 22.5 No Beam 19.85 - 1.139
350

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 187 of 227

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
3900 x 300 x
Top 22.5 No Beam - 27.484 0.818
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.76
axis

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 86.6 mm
Kluy /r = 26.62
M1 = -5.85 kNm
M2 = 16.54 kNm
Min (40, 34 - 12 x (M1/M2)) = 38.24
26.62 < 38.24, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.76
r = 86.6 mm
Klux /r = 23.26
M1 = -23.73 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 188 of 227

M2 = 23.75 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
23.26 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 16.54 - 16.54
Major Axis Mux (bottom) -5.85 - -5.85
Minor Axis Muy (top) -23.73 - -23.73
Minor Axis Muy (bottom) 23.75 - 23.75

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 84.67 kN
Mux = 16.54 kNm
Muy = -23.73 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Critical Location = Bottom Joint kN
Pu = 95.56 kN
Mux = -5.85 kNm
Muy = 23.75 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 221
[49] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 6: EQ +Z -E)
Pu = 95.56 kN
φ Pn = 95.56 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 189 of 227

Pt min for φ Pn = 0.5 %


Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 55.12 deg
MRes = 28.93 kNm
( φ ) MCap = 54.57 kNm
Capacity Ratio = MRes/ MCap
= 0.53 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 219
[47] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 81.33 kN
Muy = 29.12 kNm
Vuy = -17.2714 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 19.36 kNm
φVcy = 46.43 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 113
[13] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 63.73 kN
Mux = 22.81 kNm
Vux = -15.4701 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 190 of 227

Mm = 15.17 kNm
φVcx = 46.87 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C24
Level : 0m To 3m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2650 mm
Clear Floor Height @ luy = 2650 mm
No Of Floors = 1
No Of Columns In Group = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 191 of 227

Load Data
Analysis Reference No. = 1124
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Top Joint
Put = 94.75 kN
Muxt = -24.41 kNm
Muyt = -21.92 kNm
Vuxt = -14.22 kN
Vuyt = 13.76 kN
Pub = 105.64 kN
Muxb = 16.86 kNm
Muyb = 20.73 kNm
Vuxb = -14.22 kN
Vuyb = 13.76 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
5400 x 300 x
Top 22.5 No Beam - 19.85 1.139
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 22.5 No Beam No Beam - - 1
3900 x 300 x
Top 22.5 No Beam - 27.484 0.818
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.76
axis

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 192 of 227

Check For Stability Index


Along D
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.009
0.009< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 86.6 mm
Kluy /r = 26.62
M1 = 16.86 kNm
M2 = -24.41 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
26.62 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.76
r = 86.6 mm
Klux /r = 23.26
M1 = 20.73 kNm
M2 = -21.92 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
23.26 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -24.41 - -24.41
Major Axis Mux (bottom) 16.86 - 16.86
Minor Axis Muy (top) -21.92 - -21.92
Minor Axis Muy (bottom) 20.73 - 20.73

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 193 of 227

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 94.75 kN
Mux = -24.41 kNm
Muy = -21.92 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Critical Location = Bottom Joint kN
Pu = 105.64 kN
Mux = 16.86 kNm
Muy = 20.73 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 5: EQ +Z +E)
Pu = 105.64 kN
φ Pn = 105.64 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 41.93 deg
MRes = 32.81 kNm
( φ ) MCap = 53.87 kNm
Capacity Ratio = MRes/ MCap
= 0.609 < 1

Design Of Shear

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 194 of 227

Design for shear along D


Critical Analysis Load Combination : 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 1: EQ +X +E)
Nu = 91.24 kN
Muy = 30.32 kNm
Vuy = 18.3853 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 19.37 kNm
φVcy = 46.62 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 114
[14] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 6: EQ +Z -E)
Nu = 71.74 kN
Mux = 22.47 kNm
Vux = -15.0141 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 13.87 kNm
φVcx = 47.1 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 195 of 227

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C25
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2101
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Top Joint
Put = 162.59 kN
Muxt = 42.3 kNm
Muyt = -63.6 kNm
Vuxt = -42.75 kN
Vuyt = -22.77 kN
Pub = 180.66 kN
Muxb = -21.44 kNm
Muyb = 56.07 kNm
Vuxb = -42.75 kN
Vuyb = -22.77 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 196 of 227

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
2975 x 300 x
Top 76.19 No Beam 36.029 - 2.116
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
250 x 300 x 1871 x 300 x
Top 76.19 428.75 57.289 0.157
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.66
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 18.46

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 197 of 227

M1 = -21.44 kNm
M2 = 42.3 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
18.46 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.66
r = 115.47 mm
Klux /r = 14
M1 = 56.07 kNm
M2 = -63.6 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
14 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) 42.3 - 42.3
Major Axis Mux (bottom) -21.44 - -21.44
Minor Axis Muy (top) -63.6 - -63.6
Minor Axis Muy (bottom) 56.07 - 56.07

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 162.59 kN
Mux = 42.3 kNm
Muy = -63.6 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 316.01 kN
Mux = -14.64 kNm
Muy = -48.8 kNm
Pt Calculated = 1.21

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 198 of 227

φ Pn, Max = 2170.33 kN


Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 316.01 kN
φ Pn = 316.01 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 56.37 deg
MRes = 76.39 kNm
( φ ) MCap = 134.57 kNm
Capacity Ratio = MRes/ MCap
= 0.568 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 3: EQ -X +E)
Nu = 242.75 kN
Muy = 62.56 kNm
Vuy = -35.4543 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 24.35 kNm
φVcy = 93.99 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 199 of 227

Critical Analysis Load Combination : 228


[56] : 1.38 (LOAD 9: DL) +(LOAD 5:
Critical Load Combination = kN
EQ +Z +E)
Nu = 122.36 kN
Mux = 60.35 kNm
Vux = -41.4678 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 41.08 kNm
φVcx = 90.22 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C26
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 200 of 227

Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2105
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Top Joint
Put = 139.19 kN
Muxt = -58.16 kNm
Muyt = -28.27 kNm
Vuxt = -9.59 kN
Vuyt = 29.94 kN
Pub = 157.26 kN
Muxb = 25.64 kNm
Muyb = -1.42 kNm
Vuxb = -9.59 kN
Vuyb = 29.94 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
2175 x 200 x 2975 x 300 x
Top 76.19 20.69 36.029 1.343
300 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.87
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 201 of 227

Stiffness Beam 1 Beam 2 Beam 1 Beam 2


(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
250 x 300 x 1871 x 300 x
Top 76.19 428.75 57.289 0.157
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.66
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.87
r = 115.47 mm
Kluy /r = 18.84
M1 = 25.64 kNm
M2 = -58.16 kNm
Min (40, 34 - 12 x (M1/M2)) = 39.29
18.84 < 39.29, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.66
r = 115.47 mm
Klux /r = 14
M1 = -1.42 kNm
M2 = -28.27 kNm
Min (40, 34 - 12 x (M1/M2)) = 33.4
14 < 33.4, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 202 of 227

A B C
Major Axis Mux (top) -58.16 - -58.16
Major Axis Mux (bottom) 25.64 - 25.64
Minor Axis Muy (top) -28.27 - -28.27
Minor Axis Muy (bottom) -1.42 - -1.42

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 139.19 kN
Mux = -58.16 kNm
Muy = -28.27 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Critical Location = Bottom Joint kN
Pu = 166.46 kN
Mux = -9.52 kNm
Muy = -10.13 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 223
[51] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 8: EQ -Z -E)
Pu = 166.46 kN
φ Pn = 166.46 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 203 of 227

Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 25.92 deg
MRes = 64.66 kNm
( φ ) MCap = 135.08 kNm
Capacity Ratio = MRes/ MCap
= 0.479 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 225
[53] : 1.38 (LOAD 9: DL) +(LOAD 2:
Critical Load Combination = kN
EQ +X -E)
Nu = 112.66 kN
Muy = 55.14 kNm
Vuy = 29.9941 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 37.4 kNm
φVcy = 88.48 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 228
[56] : 1.38 (LOAD 9: DL) +(LOAD 5:
Critical Load Combination = kN
EQ +Z +E)
Nu = 108.33 kN
Mux = 40.58 kNm
Vux = -17.1758 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 23.52 kNm
φVcx = 87.87 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 204 of 227

Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C27
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2108
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Top Joint
Put = 0.4 kN
Muxt = -25.3 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 205 of 227

Muyt = 5.25 kNm


Vuxt = 3.75 kN
Vuyt = 18.12 kN
Pub = 10.56 kN
Muxb = 25.42 kNm
Muyb = -5.25 kNm
Vuxb = 3.75 kN
Vuyb = 18.12 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1
3500 x 200 x 2175 x 200 x
Top 24.107 12.857 20.69 0.72
300 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.75
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1
300 x 200 x
Top 24.107 No Beam 150 - 0.161
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.67
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 206 of 227

Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.75
r = 86.6 mm
Kluy /r = 21.65
M1 = -25.3 kNm
M2 = 25.42 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.65 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.67
r = 86.6 mm
Klux /r = 19.34
M1 = 5.25 kNm
M2 = -5.25 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.34 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -25.3 - -25.3
Major Axis Mux (bottom) 25.42 - 25.42
Minor Axis Muy (top) 5.25 - 5.25
Minor Axis Muy (bottom) -5.25 - -5.25

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 0.4 kN
Mux = -25.3 kNm
Muy = 5.25 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 207 of 227

Φ Pn, Max Check


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Critical Location = Bottom Joint kN
Pu = 10.66 kN
Mux = 22.43 kNm
Muy = -5.49 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 216
[44] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 1: EQ +X +E)
Pu = 10.66 kN
φ Pn = 10.66 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 11.72 deg
MRes = 25.84 kNm
( φ ) MCap = 49.47 kNm
Capacity Ratio = MRes/ MCap
= 0.522 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 0.4 kN
Muy = 25.3 kNm
Vuy = 18.1203 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 208 of 227

λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 25.25 kNm
φVcy = 45.81 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 0.9 kN
Mux = 12.69 kNm
Vux = 8.9226 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 12.59 kNm
φVcx = 45.78 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 209 of 227

General Data
Column No. : C28
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2112
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 2: EQ +X -E)
Critical Location = Top Joint
Put = 15.77 kN
Muxt = -25.98 kNm
Muyt = 11.2 kNm
Vuxt = 8.21 kN
Vuyt = 18.06 kN
Pub = 25.94 kN
Muxb = 24.57 kNm
Muyb = -11.79 kNm
Vuxb = 8.21 kN
Vuyb = 18.06 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 210 of 227

N-M mm mm N-M N-M


Bottom 24.107 No Beam No Beam - - 1
1600 x 200 x 3500 x 200 x
Top 24.107 28.125 12.857 0.588
300 300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.74
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1
300 x 200 x
Top 24.107 No Beam 150 - 0.161
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.67
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.74
r = 86.6 mm
Kluy /r = 21.36
M1 = 24.57 kNm
M2 = -25.98 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.36 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.67

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 211 of 227

r = 86.6 mm
Klux /r = 19.34
M1 = 11.2 kNm
M2 = -11.79 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.34 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -25.98 - -25.98
Major Axis Mux (bottom) 24.57 - 24.57
Minor Axis Muy (top) 11.2 - 11.2
Minor Axis Muy (bottom) -11.79 - -11.79

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 15.77 kN
Mux = -25.98 kNm
Muy = 11.2 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN
Pu = 30.01 kN
Mux = -5.05 kNm
Muy = -10.28 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218

[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 212 of 227

Load Combination = 10: LL) +(LOAD 3: EQ -X +E)


Pu = 30.01 kN
φ Pn = 30.01 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 23.32 deg
MRes = 28.3 kNm
( φ ) MCap = 52.66 kNm
Capacity Ratio = MRes/ MCap
= 0.537 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 15.77 kN
Muy = 25.98 kNm
Vuy = 18.0612 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 24.09 kNm
φVcy = 45.92 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 19.5 kN
Mux = 17.99 kNm
Vux = 12.9841 kN
λ = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 213 of 227

φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 15.65 kNm
φVcx = 46.2 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 304 mm
48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C29
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 300 mm
Column D = 300 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2500 mm
Clear Floor Height @ luy = 2500 mm
No Of Floors = 1

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 214 of 227

No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2116
Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint
Put = 29.38 kN
Muxt = -9.25 kNm
Muyt = 19.85 kNm
Vuxt = 14.64 kN
Vuyt = 6.43 kN
Pub = 39.54 kN
Muxb = 8.75 kNm
Muyb = -21.13 kNm
Vuxb = 14.64 kN
Vuyb = 6.43 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1
1600 x 200 x
Top 24.107 No Beam - 28.125 0.853
300
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.76
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 24.107 No Beam No Beam - - 1
300 x 200 x
Top 24.107 No Beam 150 - 0.161
300

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 215 of 227

Sway Condition (as per Stability


= Non Sway
Index)
Effective Length Factor along Minor
= 0.67
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.76
r = 86.6 mm
Kluy /r = 21.94
M1 = 8.75 kNm
M2 = -9.25 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
21.94 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.67
r = 86.6 mm
Klux /r = 19.34
M1 = 19.85 kNm
M2 = -21.13 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
19.34 < 40, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -9.25 - -9.25
Major Axis Mux (bottom) 8.75 - 8.75
Minor Axis Muy (top) 19.85 - 19.85
Minor Axis Muy (bottom) -21.13 - -21.13

Where

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 216 of 227

A = Moments from analysis


B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 39.54 kN
Mux = 8.75 kNm
Muy = -21.13 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Critical Location = Bottom Joint kN
Pu = 39.54 kN
Mux = 8.75 kNm
Muy = -21.13 kNm
Pt Calculated = 1.27
φ Pn, Max = 1232.14 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 7: EQ -Z +E)
Pu = 39.54 kN
φ Pn = 39.54 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.27
Reinforcement Provided = 4-#19
Load Angle = Tan-1(Muy/Mux)
= 67.5 deg
MRes = 22.87 kNm
( φ ) MCap = 54.68 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 217 of 227

Capacity Ratio = MRes/ MCap


= 0.418 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 217
[45] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 6.26 kN
Muy = 19.44 kNm
Vuy = 13.1061 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 18.69 kNm
φVcy = 45.75 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 222
[50] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 7: EQ -Z +E)
Nu = 39.54 kN
Mux = 21.13 kNm
Vux = 14.6397 kN
λ = 1
φ = 0.75
deff = 240.5 mm
ρw (50% of As provided) = 0.016
Mm = 16.39 kNm
φVcx = 46.43 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 218 of 227

Min. Longitudinal Bar dia X 16 = 304 mm


48 x diameter of links = 480 mm
Provided spacing = 300 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 300 --- --- 300 ---

General Data
Column No. : C30
Level : 3m To 5.8m
Design Code = ACI 318M - 2011
Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2106
Critical Analysis Load Combination : 225
Load Combination = [53] : 1.38 (LOAD 9: DL) +(LOAD 2: EQ +X -E)
Critical Location = Top Joint
Put = 196.76 kN
Muxt = -59.31 kNm
Muyt = -4.66 kNm
Vuxt = 0.53 kN
Vuyt = 34.04 kN
Pub = 211.61 kN
Muxb = 35.97 kNm
Muyb = -6.16 kNm

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 219 of 227

Vuxb = 0.53 kN
Vuyb = 34.04 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
2125 x 300 x 2975 x 300 x
Top 76.19 50.441 36.029 0.881
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major
= 0.76
Axis

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
4994 x 300 x 250 x 300 x
Top 76.19 21.463 428.75 0.169
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.67
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 220 of 227

Slenderness Check along D


K = 0.76
r = 115.47 mm
Kluy /r = 16.13
M1 = 35.97 kNm
M2 = -59.31 kNm
Min (40, 34 - 12 x (M1/M2)) = 40
16.13 < 40, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.67
r = 115.47 mm
Klux /r = 14.22
M1 = -4.66 kNm
M2 = -6.16 kNm
Min (40, 34 - 12 x (M1/M2)) = 24.91
14.22 < 24.91, Column not slender along B

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -59.31 - -59.31
Major Axis Mux (bottom) 35.97 - 35.97
Minor Axis Muy (top) -4.66 - -4.66
Minor Axis Muy (bottom) -6.16 - -6.16

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 196.76 kN
Mux = -59.31 kNm
Muy = -4.66 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 221 of 227

Pu = 284.94 kN
Mux = -62.49 kNm
Muy = -9.63 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Pu = 284.94 kN
φ Pn = 284.94 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 4.49 deg
MRes = 59.49 kNm
( φ ) MCap = 143.93 kNm
Capacity Ratio = MRes/ MCap
= 0.413 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 110
[10] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 2: EQ +X -E)
Nu = 175.99 kN
Muy = 57.48 kNm
Vuy = 33.6451 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 29.77 kNm
φVcy = 91.24 kN

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 222 of 227

Vuy < φVcy


Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 116
[16] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 8: EQ -Z -E)
Nu = 186.52 kN
Mux = 20.89 kNm
Vux = 14.8355 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = -8.47 kNm
φVcx = 171.34 kN
Vux < φVcx
Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---

General Data
Column No. : C31
Level : 3m To 5.8m

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 223 of 227

Design Code = ACI 318M - 2011


Grade Of Concrete (f'c) = C25 N/sqmm
Grade Of Steel (fy) = Fy420 N/sqmm
Consider Ductile = No
Column B = 400 mm
Column D = 400 mm
Clear Cover, Cc = 50 mm
Clear Floor Height @ lux = 2450 mm
Clear Floor Height @ luy = 2450 mm
No Of Floors = 1
No Of Columns In Group = 1

Load Data
Analysis Reference No. = 2107
Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD 10: LL) +
Load Combination =
(LOAD 5: EQ +Z +E)
Critical Location = Top Joint
Put = 199.09 kN
Muxt = -10.69 kNm
Muyt = -104.74 kNm
Vuxt = -46.71 kN
Vuyt = -2.21 kN
Pub = 217.17 kN
Muxb = -16.87 kNm
Muyb = 26.01 kNm
Vuxb = -46.71 kN
Vuyb = -2.21 kN

Effective Length Calculation


Calculation Along Major Axis Of Column
Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
2125 x 300 x 2975 x 300 x
Top 76.19 50.441 36.029 0.881
350 350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Major

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 224 of 227

Axis = 0.76

Calculation Along Minor Axis Of Column


Joint Column Beam Sizes Beam Stiffness ψ
Stiffness Beam 1 Beam 2 Beam 1 Beam 2
(Length x (Length x
Width x Depth) Width x Depth)
N-M mm mm N-M N-M
Bottom 76.19 No Beam No Beam - - 1
4994 x 300 x
Top 76.19 No Beam - 21.463 3.544
350
Sway Condition (as per Stability
= Non Sway
Index)
Effective Length Factor along Minor
= 0.87
axis

Check For Stability Index


Along D
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Along B
Q = 0.007
0.007< 0.05, Column shall be designed as non-sway frame
(Braced)

Slenderness Check
Column Is Braced Along D
Slenderness Check along D
K = 0.76
r = 115.47 mm
Kluy /r = 16.13
M1 = -10.69 kNm
M2 = -16.87 kNm
Min (40, 34 - 12 x (M1/M2)) = 26.39
16.13 < 26.39, Column not slender along D
Column Is Braced Along B
Slenderness Check along B
K = 0.87
r = 115.47 mm
Klux /r = 18.46
M1 = 26.01 kNm
M2 = -104.74 kNm
Min (40, 34 - 12 x (M1/M2)) = 36.98
18.46 < 36.98, Column not slender along B

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 225 of 227

Calculation of Design Moment


Direction Manalysis Msldr or Mc Mdesign-final
A B C
Major Axis Mux (top) -10.69 - -10.69
Major Axis Mux (bottom) -16.87 - -16.87
Minor Axis Muy (top) -104.74 - -104.74
Minor Axis Muy (bottom) 26.01 - 26.01

Where
A = Moments from analysis
B = Moment due to slenderness effect
C = Final design Moment = Maximum of (Manalysis, Maximum of (Msldr or Mc))

Final Critical Design Forces


Critical Case - Axial Load & BiAxial Bending
Pu = 199.09 kN
Mux = -10.69 kNm
Muy = -104.74 kNm

Φ Pn, Max Check


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Critical Location = Bottom Joint kN
Pu = 220.95 kN
Mux = -67.54 kNm
Muy = 3.01 kNm
Pt Calculated = 1.21
φ Pn, Max = 2170.33 kN
Pu < φ Pn, Max Hence, OK

Minimum Ast Calculation


Critical Analysis Load Combination = 218
[46] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Load Combination =
10: LL) +(LOAD 3: EQ -X +E)
Pu = 220.95 kN
φ Pn = 220.95 kN
Pt min for φ Pn = 0.5 %
Pt min (User Defined) = 1 %
Final Pt = 1 %

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 226 of 227

Resultant Moment (Combined Action)


Moment Capacity Check
Pt Calculated = 1.21
Reinforcement Provided = 4-#19 + 4-#16
Load Angle = Tan-1(Muy/Mux)
= 84.17 deg
MRes = 105.29 kNm
( φ ) MCap = 144.41 kNm
Capacity Ratio = MRes/ MCap
= 0.729 < 1

Design Of Shear
Design for shear along D
Critical Analysis Load Combination : 112
[12] : 1.2 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 4: EQ -X -E)
Nu = 162.99 kN
Muy = 65.38 kNm
Vuy = -39.0206 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 39.72 kNm
φVcy = 90 kN
Vuy < φVcy
Link For Shear Design Along D are not required

Design for shear along B


Critical Analysis Load Combination : 220
[48] : 1.68 (LOAD 9: DL) +0.5 (LOAD
Critical Load Combination = kN
10: LL) +(LOAD 5: EQ +Z +E)
Nu = 199.09 kN
Mux = 104.74 kNm
Vux = -46.7109 kN
λ = 1
φ = 0.75
deff = 340.5 mm
ρw (50% of As provided) = 0.014
Mm = 73.4 kNm
φVcx = 87.08 kN
Vux < φVcx

file:///C:/Users/Acer/AppData/Local/Temp/tmp4214.tmp 02/03/2024
Column Design: Design Calculations Page 227 of 227

Link For Shear Design Along B are not required

Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link = 10 mm
> Max. longitudinal bar dia / 4
= 4.75 mm
Criterion for spacing of normal links
Min. Longitudinal Bar dia X 16 = 256 mm
48 x diameter of links = 480 mm
Provided spacing = 250 mm

Table For Links


Note: Ductile Design of Links is Applicable Only For Boundary Elements
Required Provided
Normal Design Shear Design Ductile Design Normal Zone Ductile Zone
Link Dia. 10 --- --- 10 ---
Spacing 250 --- --- 250 ---