You are on page 1of 3

Technical Data Sheets for Mechanical Works

Abu Dhabi Sewerage Services Company


(ADSSC)

Project Reference: ODOUR CONTROL M10/15080


Project Title SYSTEMS
Project Location Date
Manufacturer Supplier
Submittal Status: + Preliminary + Detailed Engineering + Approval + Final + AS BUILT

TECHNICAL SPECIFICATIONS
1.0 Reference Standards
Specification Standard 1.01 BS EN
1.02 Utilisation Category
1.03 CE - Marking (Y/N)
2.0 Test Certificates
Certificate Nos. and 2.01 Works test
Date of Issue 2.02 Site test
2.03 Other
3.0 Mechanical Data
General
3.01 Odour Control system location
3.02 Odour control system reference
3.03 Mandatory supportive literature included (Y/N)
3.04 Type of Odour Control
3.05 Removal efficiency for Hydrogen Sulphide %
3.06 Sulphide Odour threshold at 20m from unit ppm
3.07 Material of construction
3.08 Material of fittings (stainless steel 316L)
3.09 Type of Hydrogen sulphide monitoring
3.10 Design temperature (55°C) °C
3.11 Corrosion protection data sheet included.
Mandatory compliance with General Specification
Clauses - Group C
Carbon Deodorisers
3.12 Pre-filter to Chemical scrubber Y/N
3.13 Main Filter unit Y/N
3.14 Removal efficiency of Hydrogen sulphide gas (99.9%)
3.15 Type of activated Carbon
3.16 Grade of activated carbon
3.17 Pipework material
3.18 Fan type
3.19 Details of fans - provided on ventilation technical data
sheet (Y/N)
3.20 Differential pressure gauge type
Biofilter Unit
3.21 Pre-filter to Chemical scrubber Y/N

ADSSC/TDS Mechanical M10/15080 Odour Control Systems Rev: 02 Jan. 2011 Page 1 of 3
Technical Data Sheets for Mechanical Works
Abu Dhabi Sewerage Services Company
(ADSSC)

3.22 Main Filter unit Y/N


3.23 Type of Media
3.24 Grade of Media
3.25 Pipework material
3.26 Media support deck material
3.27 Details of motors - to be provided on motor technical
data sheet (Y/N)
3.28 Type of bulking material used
Chemical Absorption Units
3.29 Type
3.30 Number of stages
st
3.31 1 Stage chemical
nd
3.32 2 Stage chemical
rd
3.33 3 Stage chemical
3.34 Removal efficiency for Hydrogen sulphide gas %
3.35 Removal efficiency of Amines %
3.36 Pressure drop per scrubber stage mm Wg
3.37 Minimum face velocity m/s
3.38 Removal efficiency for aerosol droplets above 15
microns (99%)
3.39 Dosing pump type
3.40 Details of liquid recirculation system - to be provided
on pumpset, pipework, valves and actuator technical
data sheets (Y/N)
3.41 pH measuring device type
3.42 Liquid level measuring device type
3.43 Redox probe (if fitted) Type
3.44 Details of pH measuring probe, and liquid level probe,
and Redox probe - to be provided on instrumentation
technical data sheets (Y/N)
3.45 Material of corrosion resistant liner
st
3.46 Height of 1 stage scrubber mm
nd
3.47 Height of 2 stage scrubber mm
rd
3.48 Height of 3 stage scrubber mm
3.49 Material of scrubber corrosion resistant liner
3.50 Material of scrubber outer structure
3.51 Water Softener Type
3.52 Rating for water softener between replenishment Days
3.53 Chemical storage tank type
3.54 Material of construction for Sodium Hydroxide
3.55 Material of construction for Sodium Hypochlorite
3.56 Material of construction for Sulphuric Acid
3.57 Material of construction for Make up Water
3
3.58 Working volume of tank for Sodium Hydroxide M
3
3.59 Working volume of tank for Sodium Hypochlorite M
3
3.60 Working volume of tank for Sulphuric Acid M
3
3.61 Working volume of tank for Make up Water M

ADSSC/TDS Mechanical M10/15080 Odour Control Systems Rev: 02 Jan. 2011 Page 2 of 3
Technical Data Sheets for Mechanical Works
Abu Dhabi Sewerage Services Company
(ADSSC)

3
3.62 Working volume of tank for Other M

3.63 Mandatory supportive literature included for drench


shower (Y/N)

ADSSC/TDS Mechanical M10/15080 Odour Control Systems Rev: 02 Jan. 2011 Page 3 of 3

You might also like