Contents

1. Operator Panel Main Screen .................................................................... 3


2. Operator Panel LOG-ON Screen ............................................................... 4
3. Operator Panel Machine Setting Screen .................................................. 5
4. Operator Panel Generator Setting Screen. .............................................. 6
5. Operator Panel Status Screen .................................................................. 7
6. Operator Panel Alarm Screen .................................................................. 8
7. Operator Panel Trouble shooting Screen ................................................. 9
8. Operator Panel Help Screen................................................................... 10
9. Operator Panel Emergency Stop Screen ................................................ 11

Page 2
M-32091-SIA FoamTEC GB - HMI Panel Edition 1

1. Operator Panel Main Screen


To set up treatment and machine parameters:

10

1 8

2
7
3

Button Function
1 Watt/Voltage actual read out
2 Watt/Voltage Set read out
3 Alarm read out
4 LOG IN admin button
5 LOG OUT admin button.
6 Stop machine button
7 Start machine button
8 Door status
9 Open / close machine button
10 Machine status read out.

Page 3
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
2. Operator Panel LOG-ON Screen

Button Function
1 User ID = admin
2 Password 6640

Important note :
Before entering “Setting menu”, User ID and password must be entered, and push
“ok” button.

Page 4
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
3. Operator Panel Machine Setting Screen

Button Function
1 Navigate button
2 Trouble shooting button
3 Status of the machine

Page 5
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
4. Operator Panel Generator Setting Screen.

1 2

Button Function
1 Go to Generator setting menu screen
2 Go to Machine menu screen

NOTE: For further information please refer to the generator manual.

Page 6
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
5. Operator Panel Status Screen

Button Function
1 Reset machine running hours button
2 Reset machine treatment running hours
generator.

Page 7
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
6. Operator Panel Alarm Screen

ALARMS: DESCRIPTION: ACTION:

Arc Alarm Generator G1 Electrodesystem have a short circuit Read Generator Manual for Troubleshoot

Power Alarm Generator G1 Power Alarm Read Generator Manual for Troubleshoot

Voltage Alarm Generator G1 Voltage Alarm Read Generator Manual for Troubleshoot

Current Alarm G1 Current Alarm Read Generator Manual for Troubleshoot

ArcStopAlarm G1 Electrodesystem have a short circuit Read Generator Manual for Troubleshoot

Arc + Arc Stop Alarm G1 Electrodesystem have a short circuit Read Generator Manual for Troubleshoot
Alarm Air Pressure Air pressure to machine is low. Check Air Pressure min 6 Bar
Check Blower, and if still occur, check
Ozon Alarm Low Top Flow in Exhaust system is low filters
Check Exhaust Output, and if still occur
Ozon Alarm High Top Flow in Exhaust system is blocked check filters
Roller not rotate, when treatment is Check Roller Rotation, before start
Alarm Rotation Top started in manual. treatment manual.

Page 8
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
7. Operator Panel Trouble shooting Screen

Button Function
1 Turn the Blower top on and off manually
2 Turn the generator top on and off manually
3 Navigate buttons

Page 9
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
8. Operator Panel Help Screen

Page 10
M-32091-SIA FoamTEC GB - HMI Panel Edition 1
9. Operator Panel Emergency Stop Screen

If any of the two Emergency Stop switches or the door interlock is activated, the
Emergency Stop screen is present.