Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Diode chart
PLC Survey
The PLC consists of a basis module and 4 extension modules.

K90 K110 K150 K190 K230

No. Type In- and outputs Address El-chat


K90 Basis module page 4
K110 Input - Output 16 digital inputs K110 I.0 – I.15 page 5
module 8 digital outputs K110 Q.0 – Q.7 page 6
K150 Input - Output 16 digital inputs K150 I.0 – I.15 page 7
module 8 digital outputs K150 Q.0 – Q.7 page 8
K190 Input - Output 16 digital inputs K190 I.0 – I.15 page 9
module 8 digital outputs K190 Q.0 – Q.7 page 10
K230 Output module 4 analogue outputs QW0 – QW3 page 11

A number of LED’s are mounted on every module indicating whether the individual in- and
outputs on the modules are active. The LED on the module equipped with analogue outputs,
however, only indicate that the module is on.

1155, 1167-1186, 1198-1209 Diode chart.doc Page 1 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

In- and output survey


Inputs
Adr. Function Default position Signal from
K110:I.0 Safety stop, Rollertrack On in standard operation Sensor B608 and B610
K110:I.1 Revolutions, chain drive motor Varies according to motor position Sensor B602
K110:I.2 Loading switch, head in cargo hold On when switch is activated Switch S362 and S364
K110:I.3 Unloading switch, head in cargo hold On when switch is activated Switch S362 and S364
K110:I.4 Loading switch, rear belt boom On when switch is activated Switch S372 and S374
K110:I.5 Unloading switch, rear belt boom On when switch is activated Switch S372 and S374
K110:I.6 Counting pulse B, extraction length Varies according to motor position Sensor B604
K110:I.7 Counting pulse A, extraction length Varies according to motor position Sensor B602
K110:I.8 Reset, extraction length On when Rollertrack is right out of cargo hold Sensor B606
K110:I.9 Thermal fuse, chain drive motor On in standard operation Sensor in motor M647
K110:I.10 Handle, Rollertrack into cargo hold On when handle is activated Sensor B626 and B638
K110:I.11 Handle, Rollertrack out of cargo hold On when handle is activated Sensor B624 and B636
K150:I.0 Luggage counter On when no items are in front of the counter Sensor B722
K150:I.1 Level control, belt raising On for raising the belt Sensor B682
K150:I.2 Level control, belt lowering On for lowering the belt Sensor B684
K150:I.3 Flex ramp rests on aircraft On when the flex ramp rests on the fender Sensor B686
K150:I.4 Emergency stop circuit On in standard operation Relay K10,K72 and K74
K150:I.5 Not in use
K150:I.6 Not in use

1155, 1167-1186, 1198-1209 Diode chart.doc Page 2 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Adr. Function Default position Signal from


K150:I.7 Belt boom down On when belt boom is down Sensor B803
K150:I.8 Not in use
K150:I.9 Handbrake applied On when Handbrake is applied Sensor B954
K150:I.10 Not in use
K150:I.11 Safety stop, hydraulic belt On in standard operation Sensor B376 and B378
K150:I.12 Voltage control 24V On when voltage is OK Relay Q12
K150:I.13 Not in use
K150:I.14 Control of logic in handles Flashes when logic is OK Circuit board K50
K150:I.15 Service Mode On when in service mode Switch S730
K190:I.0 Retraction error Varies according to track position Sensor B612
K190:I.1 Ignition key on When the ignition is switched on Relay K10
K190:I.2 Gearlever not in neutral On when in driving mode Relay K943
K190:I.3 Not in use
K190:I.4 Not in use
K190:I.5 Not in use
K190:I.6 Front cylinder raise On when raising front cylinder Relay K705
K190:I.7 Front cylinder lower On when lower front cylinder Relay K706
K190:I.8 Rear cylinder raise On when raising rear cylinder Relay K707
K190:I.9 Rear cylinder lower On when lowering rear cylinder Relay K708
K190:I.10 Sensor rear lifting boom On when it is allowed to lift the rear cyl. When Sensor B867
flex ramp rests on plane
K190:I.11 Sensor slow down conveyor On when boom is in slow down area Sensor B702

1155, 1167-1186, 1198-1209 Diode chart.doc Page 3 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Adr. Function Default position Signal from


K190:I.12 Not in use
K190:I.13 Not in use
K190:I.14 Not in use
K190:I.15 Not in use

Outputs digital
No. Function Default position Signal to
K110:Q.0 Rollertrack into cargo hold On when Rollertrack drives into cargo hold Curtis control K650.12
K110:Q.1 Rollertrack out of cargo hold On, when Rollertrack extracts from cargo hold Curtis control K650.11
K110:Q.2 Bypass valve, hydraulic pressure On when building up hydraulic pressure Relay K128
K110:Q.3 Rear cylinder raise On when raising rear cylinder Relay K129
K110:Q.4 Rear cylinder lower On when lowering rear cylinder Relay K130
K110:Q.5 Enable signal On when hydraulic belt and rollers are rotating K290, K310,K325 & K450
K110:Q.6 Not in use
K110:Q.7 Light in lamp, emergency stop On when emergency stop is activated Lamp P58
activated
K150:Q.0 Rollertrack section 2 activated On when rollers in section 2 must run Relay K490
K150:Q.1 Rollertrack section 3 activated On when rollers in section 3 must run Relay K530
K150:Q.2 Rollertrack section 4 activated On when rollers in section 4 must run Relay K570
K150:Q.3 Not in use
K150:Q.4 Not in use
K150:Q.5 Not in use
K150:Q.6 Not in use

1155, 1167-1186, 1198-1209 Diode chart.doc Page 4 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

No. Function Default position Signal to


K150:Q.7 Not in use
K190:Q.0 Warning lamp in dashboard Flashing when driving is prevented Lamp P614
K190:Q.1 Driving allowed On when driving is allowed Relay K952
K190:Q.2 Not in use
K190:Q.3 Not in use
K190:Q.4 Not in use
K190:Q.5 Accustic alarm at start Sounding when the output is on P368, P369
K190:Q.6 Belt loading On when belt is loading Relay K213
K190:Q.7 Belt Unloading On when belt is unloading Relay K214

Outputs analogue
No. Function Default setting Signal to
K230:QW0 Speed and direction rollers 2,5V when rollers and belt have been stopped Curtis control K290.1
1,3V – 0,5V when loading (min. – max. speed ) Curtis control K310.1
3,8V – 4,5V when unloading (min. – max.
speed)
K230:QW1 Speed, Rollertrack in and out of cargo 1,0V – 4,5V Curtis control K650.6
hold

K230:QW3 Speed front cylinder 0V when cylinder is stopped PR Box K690.5


6V to 9V when cylinder raising max speed
-6V to -9V when cylinder lowering max speed
2V to 5V when cylinder raising level mode
-2V to -5V when cylinder lowering level mode

1155, 1167-1186, 1198-1209 Diode chart.doc Page 5 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Function survey
Starting Rollertrack and hydraulic belt in loading direction
Condition (inputs) Action (outputs)
Belt has stopped
K110:I.2 On < 0,5 s. K230:QW0 1,3V – 0,5V
or K110:I.4 On < 0,5 s. and K110:Q.2 On
and K150:I.4 On and K110:Q.5 On
and K150:I.9 On and K190:Q.5 Flashes slowly
and K150:I.11 On and K190:Q.6 On
and K150:I.12 On and K230:QW3 0V
and K190:I.2 Off
and K190:I.6 Off
and K190:I.7 Off
and K190:I.8 Off
and K190:I.9 Off

Starting Rollertrack and hydraulic belt in unloading direction


Condition (inputs) Action (Outputs)
Belt has stopped
and K110:I.3 or K110:I.5 On < 0,5 s. K230:QW0 3,8V – 4,5V
and K150:I.4 On and K110:Q.2 On
and K150:I.9 On and K110:Q.5 On
and K150:I.11 On and K190:Q.5 Flashes quick
and K150:I.12 On and K190:Q.7 On
and K190:I.2 Off and K230:QW3 0V
and K190:I.6 Off
and K190:I.7 Off
and K190:I.8 Off
and K190:I.9 Off

1155, 1167-1186, 1198-1209 Diode chart.doc Page 6 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Stopping Rollertrack and hydraulic belt


Condition (inputs) Action (Outputs)
Belt is running
and K110:I.2 On < 0,5 sec. K230:QW0 2,5V
or K110:I.3 On < 0,5 sec. or K110:Q.2 Off
or K110:I.4 On < 0,5 sec. or K110:Q.5 Off
or K110:I.5 On < 0,5 sec. or K230:QW3 6,0V – 9,0V
or K150:I.0 On > 1 min. or K230:QW3 -6,0V - -9,0V
or K150:I.4 Off
or K150:I.9 Off
or K150:I.11 Off
or K150:I.12 Off > 3sek.
or K190:I.2 On
or K190:I.6 On
or K190:I.7 On
or K190:I.8 On
or K190:I.9 On

Front Cylinder Raising


Condition (inputs) Actions (Outputs)
K190:I.6 On K230:QW3 6,0V – 9,0V

Front Cylinder Lowering


Condition (inputs) Actions (Outputs)
K150:I.3 On K230:QW3 -6,0V – -9,0V
and K190:I.7 On

Rear Cylinder Raising


Condition (inputs) Actions (Outputs)
K150:I.3 On K110:Q.3 On
and K190:I.8 On

Rear Cylinder Lowering


Condition (inputs) Actions (Outputs)
K150:I.3 On K110:Q.4 On

1155, 1167-1186, 1198-1209 Diode chart.doc Page 7 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

and K190:I.9 On

Driving with Chassis prevented


Condition (inputs) Actions (Outputs)
K150:I.4 On K190:Q.1 On
and K150:I.9 Off
or K110:I.8 Off
or K150:I.3 Off
The prevention of the ability to drive with the chassis can be overridden with the warning
light switch:
• when reversing the switch must be pressed all the time (dead man function)
• when the driving direction switch is set in forward the warning light switch must be
pressed once to activate a self hold, so that the driver can keep both hand on the
steering wheel when driving.
• Press the button and hold it down before direction switch are being activated, the
button can be relief when direction switch are in forward.

Counter
Condition (inputs) Actions (Outputs)
K230:QW1 <> 2,5V Display adds or subtracts depending on
and K150:I.0 Off > 150mm chosen direction

1155, 1167-1186, 1198-1209 Diode chart.doc Page 8 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Rollertrack into the cargo hold


Condition (inputs) Actions (Outputs)
K110:I.9 On K230:QW1 1,0V – 4,5V
and K110:I.10 On and K110:Q.0 On
and K150:I.4 On
and K150:I.9 On
and K150:I.12 On
and K190:I.2 Off

Rollertrack out of the cargo hold


Condition (inputs) Actions (Outputs)
K110:I.0 On K230:QW1 1,0V – 4,5V
and K110:I.8 Off and K110:Q.1 On
and K110:I.11 On
and K150:I.4 On
and K150:I.9 On
and K190:I.2 Off

Rollertrack automatically right in place


Condition (inputs) Actions (Outputs)
K110:I.0 On K230:QW1 1,0V – 4,5V
and K110:I.8 Off and K110:Q.1 On < 10 sec.
and K110:I.10 Off
and K110:I.11 Off
and K150:I.3 On
and K150:I.4 On
and K150:I.15 Off

Starting Rollertrack section 2


Condition (inputs) Actions (Outputs)
Length of Rollertrack > 1,9 m K150:Q.0 On

Starting Rollertrack section 3


Condition (inputs) Actions (Outputs)
Length of Rollertrack > 4,0 m K150:Q.1 On

1155, 1167-1186, 1198-1209 Diode chart.doc Page 9 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Starting Rollertrack section 4


Condition (inputs) Actions (Outputs)
Length of Rollertrack > 6,0 m K150:Q.2 On

Level adjustment of flexramp to horizontal, Conveyor lowering


Condition (inputs) Actions (Outputs)
K150:I.2 On K110:Q.2 On
and K150:I.3 Off and K230:QW3 -2,0V – -5,0V
and K150:I.4 On
and K150:I.9 On
and K190:I.2 Off
and K190:I.6 Off

Level adjustment of flexramp to horizontal, Conveyor raising


Condition (inputs) Actions (Outputs)
K150:I.1 On K110:Q.2 On
and K150:I.3 Off and K230:QW3 2,0V – 5,0V
and K150:I.4 On
and K150:I.9 On
and K190:I.2 Off
and K190:I.6 Off

pLight in warning lamp in the dashboard


Condition (inputs) Actions (Outputs)
K110:I.8 Off K190:Q.0 Flashing
or K150:I.3 Off
and K150:I.4 On
and K150:I.9 Off

or K150:I.15 On K190:Q.0 Constantly on

Light in emergency stop


Condition (inputs) Actions (Outputs)
K150:I.4 Off K110:Q.7 On

1155, 1167-1186, 1198-1209 Diode chart.doc Page 10 of 11


Power Stow A/S Diode chart 1155, 1167-1186, 1198-1209 SouthWest Airlines

Set enable signal


Condition (inputs) Actions (Outputs)
Belt running K110:Q.5 On
K150:I.11 On
and K90.2 On < 0,5 sec.
or K90.3 On < 0,5 sec.
or K90.4 On < 0,5 sec.
or K90.5 On < 0,5 sec.
or K210.15 On

Control of logic in handles


Condition (inputs) Actions (Outputs)
K150:I.14 Flashing Display Normal
or K150:I.14 On > 2 sek Display warning Error in handle
or K150:I.14 Off > 2 sek Display warning Broken wire

Permission to lift the rear cyl. when flexramp rests on aircraft


Condition (inputs) Actions (Outputs)
K150:I.3 Off K110:Q.2 On
and K150:I.4 On and K110:Q.3 On
and K190:I.8 On
and K190:I.10 On

Permission to lower the rear cyl. when flexramp rests on aircraft


Condition (inputs) Actions (Outputs)
K150:I.3 Off K110:Q.2 On
and K150:I.4 On and K110:Q.4 On
and K190:I.9 On
and K190:I.10 On

1155, 1167-1186, 1198-1209 Diode chart.doc Page 11 of 11