Diode chart
PLC Survey
The PLC consists of a basis module and 4 extension modules.
A number of LED’s are mounted on every module indicating whether the individual in- and
outputs on the modules are active. The LED on the module equipped with analogue outputs,
however, only indicate that the module is on.
Outputs digital
No. Function Default position Signal to
K110:Q.0 Rollertrack into cargo hold On when Rollertrack drives into cargo hold Curtis control K650.12
K110:Q.1 Rollertrack out of cargo hold On, when Rollertrack extracts from cargo hold Curtis control K650.11
K110:Q.2 Bypass valve, hydraulic pressure On when building up hydraulic pressure Relay K128
K110:Q.3 Rear cylinder raise On when raising rear cylinder Relay K129
K110:Q.4 Rear cylinder lower On when lowering rear cylinder Relay K130
K110:Q.5 Enable signal On when hydraulic belt and rollers are rotating K290, K310,K325 & K450
K110:Q.6 Not in use
K110:Q.7 Light in lamp, emergency stop On when emergency stop is activated Lamp P58
activated
K150:Q.0 Rollertrack section 2 activated On when rollers in section 2 must run Relay K490
K150:Q.1 Rollertrack section 3 activated On when rollers in section 3 must run Relay K530
K150:Q.2 Rollertrack section 4 activated On when rollers in section 4 must run Relay K570
K150:Q.3 Not in use
K150:Q.4 Not in use
K150:Q.5 Not in use
K150:Q.6 Not in use
Outputs analogue
No. Function Default setting Signal to
K230:QW0 Speed and direction rollers 2,5V when rollers and belt have been stopped Curtis control K290.1
1,3V – 0,5V when loading (min. – max. speed ) Curtis control K310.1
3,8V – 4,5V when unloading (min. – max.
speed)
K230:QW1 Speed, Rollertrack in and out of cargo 1,0V – 4,5V Curtis control K650.6
hold
Function survey
Starting Rollertrack and hydraulic belt in loading direction
Condition (inputs) Action (outputs)
Belt has stopped
K110:I.2 On < 0,5 s. K230:QW0 1,3V – 0,5V
or K110:I.4 On < 0,5 s. and K110:Q.2 On
and K150:I.4 On and K110:Q.5 On
and K150:I.9 On and K190:Q.5 Flashes slowly
and K150:I.11 On and K190:Q.6 On
and K150:I.12 On and K230:QW3 0V
and K190:I.2 Off
and K190:I.6 Off
and K190:I.7 Off
and K190:I.8 Off
and K190:I.9 Off
and K190:I.9 On
Counter
Condition (inputs) Actions (Outputs)
K230:QW1 <> 2,5V Display adds or subtracts depending on
and K150:I.0 Off > 150mm chosen direction