ATEX compliance:
PDEL-1067 G
www.nov.com
Document number PDEL-1067
Revision G
Page 2 of 6
REVISION HISTORY
CHANGE DESCRIPTION
www.nov.com
Document number PDEL-1067
Revision G
Page 3 of 6
www.nov.com
Document number PDEL-1067
Revision G
Page 4 of 6
www.nov.com
Document number PDEL-1067
Revision G
Page 5 of 6
www.nov.com
Document number PDEL-1067
Revision G
Page 6 of 6
501/ 453/ Baseefa 06 ATEX These glands are suitable for use within an
83444-(-) Hawke Operating temperature: -20 ºC to + 40ºC
UNIV/ 0057X operating temperature range of -60ºC to + 80ºC.
When the gland is used for increased safety or dust
protection, the entry thread shall be suitably sealed All glands sealed by NOV P/N-59000424(-) washer to
to maintain the ingress protection rating of the maintain IP Rating of minimal IP56.
associated enclosure.
Glands for use with braided cables are only
Braided cable NOV P/N-56625-(-) used, cabling to be
suitable for fixed installations, the cable for which
considered fixed, additional cable support is used where
must be effectively clamped to prevent pulling and
required.
twisting.
Right angle
The components shall be installed with suitable O-
979978- adapter M20 SIRA 00 ATEX
Raxton ring seal fitted against the shoulder at the base of Sealed by NOV P/N-59000424(-) washer
M20-BR female -> 1073U
the thread.
M20 male
These components shall only be used where
temperature, at the point of mounting, is in the Operating temperature: -20 ºC to + 40ºC
range -20 ºC to + 60ºC
These components shall not be used for
Mounting on static panel away from floor, not rated high
applications where there is a high risk of
impact
mechanical damage.
When the cylindrical inductive sensors, types NC
and NJ are used in a temperature range between -
Pepperl & PTB OO ATEX
93939-1 NJ4-12GK-N 60 ºC and -20 ºC, they shall be protected against N/A, Operating temperature: -20 ºC to + 40ºC
Fuchs inc. 2048X
impact stress by installation into an additional
housing.
The connections facilities of the cylindrical
inductive sensors, types NC and NJ shall be
installed as such that he degree of protection IP20 Connected to JB NOV P/N-980040-2 having IP66.
according to EIC-Publikation 60529:1989 is met as
a minimum.
Special condition #3 and #4 not applicable. (other
type)
www.nov.com
Physikalisch-Technische Bundesanstalt
Braunschweig and Berlin
Dr.-Ing. U. Engel
Regierungsdirektor
Page 1/2
EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated
only without alteration. Extracts or alterations are subject to approval by the Physikalisch-Technische Bundesanstalt.
In case of dispute, the German text shall prevail.
Physikalisch-Technische Bundesanstalt Ÿ Bundesallee 100 Ÿ D-38116 Braunschweig
Physikalisch-Technische Bundesanstalt
Braunschweig and Berlin
(13) SCHEDULE
(14) EC-Type Examination Certificate PTB 99 ATEX 3103
Technical data
Rated voltage: max. 1100 V
(depending on the operating voltage range
of the terminals used)
Rated current, number of conductors and conductor cross section are determined in the
associated additional sheets.
Ambient temperature range, max.: -50 °C ≤ T ≤ +55 °C
Contact, foreign particles and water protection min. IP 54 to EN 60 529: 1991
Note
The degree of protection - at least IP 54 - is achieved only when the tested gaskets, cable
glands and stopping plugs are used properly.
Instruction of the manufacturer "Clean only with wet cloth" is to be followed.
The suitability for low ambient temperatures is visible by special marking. Only such separately
certified sealing gaskets and built-in and built-on components, which are suitable for these
temperatures, are used. Additional instructions of the manufacturer are to be followed.
(16) Test report PTB Ex 99-30041 (consisting of 6 pages, description and 2 drawings)
EC-type-examination Certificates without signature and official stamp shall not be valid. The certificates may be circulated
only without alteration. Extracts or alterations are subject to approval by the Physikalisch-Technische Bundesanstalt.
In case of dispute, the German text shall prevail.
Physikalisch-Technische Bundesanstalt Ÿ Bundesallee 100 Ÿ D-38116 Braunschweig
Supplementary Sheet 1
Note
1) Every entered conductor and every internal connection wire counts as conductor.
Bridges and earth conductors are not counted.
Note
1) Every entered conductor and every internal connection wire counts as conductor.
Bridges and earth conductors are not counted.
number of
loaded permissible rated current in A at conductor size
terminals 1,5 mm² 2,5 mm² 4 mm² 6 mm² 10 mm²
7 13 17 24 32 44
6 14 18 33 46
5 25 49
≤4 16 20 35 50
Note
1) Every entered conductor and every internal connection wire counts as conductor.
Bridges and earth conductors are not counted.