Professional Documents
Culture Documents
To the 1
pass shell enters 6800 kg/h of water at 95 ºC The overall heat transfer coefficient is Ui=1400
W/m2·ºC. The average rate of water in the tubes (internal diameter ¾”) is 0.36 m/s. Due to space
limitations, the exchanger cannot be longer than 2.43 m (8 ft). According to this restriction,
calculate the number of tube passes, the number of tubes, and the length of these tubes.
Energy balance:
Fluid Water hot Water cold
shell tubes q = m(c)*cp(c)*(Tc,out‐Tc,in)
Tin 95 40 q = 3.78kg/s *4180J/kg.K *(55‐40)K = 236.87 kW
Tout 65 55 Th,out = Th,in – q/[m(h)*cp(h)]
m 6800 kg/h 13600 kg/h Th,out =95‐236.87e3/(1.89*4180) = 65ºC
(kg/s) 1.89 kg/s 3.78 kg/s Th,av=(95+65)/2=80ºC ‐> cp(h) = 4199 J/kg.K
Tav 47.5ºC Th,out recalc = 65 ºC
Th,in
LMTD(counter) = (95‐55)‐(65‐40)/ln(95‐55)/(65‐40))
LMTD(counter) = 31.97K
Tc,out Th,out
Ai Nt / p ·Np ··Di ·L
1.‐ Across = m(c)/(*u) = 3.78kg/s/(989kg/m3*0.36m/s) = 0.0106m2
Nt/p = Across(total)/Across(1tube) = 37.2 tubes/pass
Across,1tube=Pi*D^2/4
2.‐ L < 2.43m
1 pass in shell
Let’s consider Np = 2
2 pass in tubes
Fluid Water hot Water cold
shell tubes
Tin 95 40
Tout 65 55
m 6800 kg/h 13600 kg/h
(kg/s) 1.89 kg/s 3.78 kg/s
Tav 80 ºC 47.5ºC
R = (95‐65)/(55‐40) = 2
P = (55‐40)/(95‐40) = 0.273
1 S
R 2
1 ln
1 R S
F = 0.920
2 S R 1 R 2
1
R 1 l n
2 S R 1
R 2
1
Ai Nt / p ·N p ··Di ·L
L = 5.38m2/(37*1**0.019m) = 2.39 m