Professional Documents
Culture Documents
MV - Diplo Manual & Limitations
MV - Diplo Manual & Limitations
- Air Condition compressors locations are limited to the locations shown in this manual for each type. And it is
not allowed to install Air Condition compressors anywhere else.
-All A.C units must have an internal drainage to the nearest floor drain
-it is not allowed at all to make any external drainage (on elevations).
06- DOORS & WINDOWS GLASS:
- Frameless Security glass doors & windows are only allowed at side or back elevations.
- The only design permitted of main doors is as following with ester paint.
- Terraces drainage is to be floor drain connected to the nearest bath as following samples.
Type chalet terrace floor drain
- Garden Pergolas must be at least 2m away from the side fence along building and can be attached with the fence
along back yard (as per the attached sketch ).
- Garden pergolas maximum area must be 25 % from back yard area with minimum area 15 m² if needed.
- The material used must be the same as the compound pergolas wood with (Brown color)
- Garden Pergolas design must be as per the attached design .
- Maximum height of pergola must be 3.00 m from finish floor .
- Softscape in back & side yards is allowed except (Fence arboreal) that allowed only beside fences .
05- HARDSCAPE
- Garden hardscape is allowed in back yards unless it blocks sea view or breeze of neighbors.
- Maximum height allowed for all hardscape elements is 0.90 m along 7.5 m distance from back fence .
-Garden Lighting fixtures with dim lighting (up lights, spikes , polars) are allowed with maximum height
-Back Fences should be only Soft scape (Fence arboreal) behind existing stone fence with maximum
Height 0.90 m .
-Side fences can be soft scape or builder with height 0.90 along 7.50 m from back fence and it increased
Gradually to 2.00 m .
- Side and back Fences are allowed to be covered by shrubs or bushes without
- Water features are not allowed in front yard, or in narrow side yards.
-The required documents should be presented by client to approve water features design :
2- longitude section for pool contain pool depth and foundation levels for (villa,pool and fences)
3-In case of conflicting between foundation levels for both of villa and pool client should present a signed
Structural drawings from union consultant shows retaining soil under villa foundations.
5- signed undertake from client ensures his responsibility about construction and building safety.
All previous documents & drawings should be presented as a hard copy attached with auto cad files if possible.
06- SHOWERS:
- Showers are allowed only in side – yards attached with the building 6 meters away from
front elevation (fixed shower without any cabinets ,walls or sheets around it)
-Built in seats should be finished by cement plaster and painted with the same color tone of the villa
- No constructions are allowed in the gardens including light constructions (wooden, steel…ect.).
- Roof separators are allowed for attached and simi-attached units that have roof access with one of the
Option 1 :
- roof separator can be fence arboreal beside builder separator with maximum height 2.2 meters .
roof separator location
Option 2 :
- Wooden Separator as per the following design with maximum height 2.00 meters .
03- ROOF LIGHTING:
- It is allowed to use lighting posts, ground spot lights, up lights or indirect light in the parapet wall.
04- ROOF BUILT-IN FEATURES ( SEATS , FLOWER BOXES , COUNTERS , BARBEQUE ,…….…):
- All roof built in features maximum height must be same as parapet height .
- All roof built in features should be made of light weight bricks, filled with light materials and painted with
- Roof water tank location is allowed only nearest to slab beams and columns .
- Roof water must be covered with wooden frame (brown color) as per the following design .
- Roof water tank must be beside a solid part of roof parapet so it cannot be seen from the street or the valley.
- Maximum volume of Roof water tank must be 1.00 meter cube with Horizontal shape and maximum height
should be same as parapet
-In chalet type it is recommended to install water tank at the shown location in the following drawing .
- Roof Jacuzzi is allowed only After Mountain View approval to study its location ,load ,…ect.
- must be fixed only inside the allowed limitations (4 meters away from front elevations and 2 meters away from
back & side elevations as shown in the following drawing.
`