The Ultimate Moment of Resistance of the Section is determined by using the strain compatibility method by an
iterative approach. The strains in the tension and compression reinforcement are determined assuming a linear
strain distribution. The depth to the neutral axis is adjusted until the total compressive forces equal the
total tensile forces. The Moment of Resistance is then obtained by taking moments of the forces about the neutral
axis. The following results are obtained:
Compression Tension
Force(kN) La Force(kN) La Force(kN) La
Section1 4480 95.861 Layer1 1748.3 1239.9
Layer2 2731.7 1339.9
Ductility Check
Area of Reinforcement in Tension Zone = 10304 mm2
Depth to Centroid of Reinforcement in Tension Zone = 1465 mm
Strain at Centroid of Tension Reinforcement = 0.0277 Strain at Yield = 0.0022